Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.9 L+₹6.1 L (26.6%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Nov 2023, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF STREET LIGHT, SIGN BOARDS AND PERIODICAL SERVICES OF CERTAIN BLDGS IN THE AREA OF AGE E/M EXT (ELECT) UNDER GE E/M LUCKNOW
2023_MES_623275_1
GE/EM/LKO/EXT(ELECT)/T-50 OF 2023-2024
Open Tender
Civil Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹70,000
Yes
30 Dec 2023
14 Oct 2023
21 Nov 2023
14 Oct 2023
14 Nov 2023
28 Oct 2023
Amount
Excavating in post holes (or similar holes) in soft / lose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed by Engineer -in- Charge
Dismantling sign board of any shape, type, sections including taking out embedded portion in PCC / natural ground and making good complete all as specified and directed. Note:- Unit quoted rate includes the cost of dismantling the concrete blocks holding the sign board and filling the post hole with earth.
M&L for cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundaton, filling, mass concrete etc. complete all as specified and directed.
S&F stainless steel round pipe, ornamental design, 65 mm nominal bore (Grade-304), minimum wall thickness 1.58 mm (16 gauge), as in frame / post of sign boards, including cut to size bending in shape, welding, jointing, fixed on groung / column / wall complete all as specified and directed.
S&F stainless steel round pipe, ornamental design, 50 mm nominal bore (Grade-304), minimum wall thickness 1.58 mm (16 gauge), as in frame / post of sign boards, including cut to size bending in shape, welding, jointing, fixed on groung / column / wall complete all as specified and directed.
S&F stainless steel round pipe, ornamental design, 40 mm nominal bore (Grade-304), minimum wall thickness 1.58 mm (16 gauge), as in frame / post of sign boards, including cut to size bending in shape, welding, jointing, fixed on groung / column / wall complete all as specified and directed.
S&F stainless steel round pipe, ornamental design,25 mm nominal bore (Grade-304), minimum wall thickness 1.58 mm (16 gauge), as in frame / post of sign boards, including cut to size bending in shape, welding, jointing, fixed on groung / column / wall complete all as specified and directed.
S&F Aluminium composite panel 2 mm thick in non metallic colour of approved shades consisting of 1 mm thick mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on exposed face and polymer (Service) coating on other face, with degreasing treatment & fine grinding on front side for proper pasting of sheet, fixed in as sign board, over SS frame including all fixing arrangement complete all per manufacturer instruction & as directed.
S&F High Intensity Prismatic retro-Reflective Sheeting of approved colour / shade fixed on ACP sheet fully covered including lattered, writing information / logo with same sheeting by computerised cutting in white colour / shade. The letters approximately covering upto 60% area of the board complete all as specified and directed. Note:- (i) ACP sheet shall be measured and paid for separately. (ii) Cost of letter writing with retro-Reflective Sheeting is includied in unit rate.
Cleaning of surrounding area of E&M & WS installation around the bldg, transformer, GOD LT panel by grass cutting manually or mechanically (Bush cutter) as per requirement basis and trimming as directed by Engr-in-Charge, including taking out all shrubs, saplings with bushes and any type of vegetation and removing from site, complete all as specified and directed.
M&L preparation of old painted surface of walls and applying one coat exterior emulsion weather coat paint of Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) complete all as specified and directed.
M&L for preparation old treated surface of wall and applying one coat of cement base paint with roller complete all as specified and directed.
M&L for Preparation of old decorated surfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds , moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of oil bound distemper, applied with roller, after removal of nails & filling nail hole with putty complete all as specified and directed by Engineer-in-charge.
M&L for prepration of old decorated surface of wall and applying one coat of white wash complete all as specified and directed.
M&L for prepration of old decorated surface of ceiling and applying one coat of white wash complete all as specified and directed.
M&L for prepration of old treated steel surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old treated wood or wood based surface of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted plastered wall surfaces of any description and applying two coats of synthetic enamel paint without showing signs of brushes mark complete all as specified and directed.
M&L for rewriting letters or figures (Block, Roman Italic or Indian) n exc 30 cm high with a thick coat of synthetic enamel paint without showing signs of brushes mark complete all as specified and directed.
M&L for rewriting stops.commas, short lines, dashes, hyphens, brackets etc with a thick coat of synthetic enamel paint without showing signs of brushes mark complete all as specified and directed.
M&L for cleaning of grass from roof of the bldgs and OHT including cleaning away all grass, vegetation sapling shubs bush weed, undergrouth, roots of small tree and removing rubbish etc. to a distance exc 1.00 Km but n. exc 1.50 KM from the starting point and applying 15 mm thick screed plaster in CM 1:4 including finishing the surface even and smooth with using extra cement and mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Rate included for necessary scaffolding and arrangments for working upto 25 m height and working on any type of roof like with necessary safety measures and labour wastage due to working in restricted areas. (ii) WPC will be measured and paid seperately.
Demolition of brick work or stone / boulder masonry built in cement mortar or cement lime mortar including all quions, arches, pillars etc but excluding ashlar facings, dressed stone work and pre cast concrete articles complete all as specified and directed.
M&L for Brick work with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, using bricks of size 230 mm x 110 mm x 70 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
M&L for Brick work in half brick thick wall with Fly ash brick designation 100 Kg / Sqcm, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4, using bricks of size 230 mm x 110 mm x 70 mm confirming to IS 12894, complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and paving n. exc 15 cm thickness (below or above ground level) and removal of debries to a distance exe 2.5 Km but n. exe 5 Km complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping, padding and bed block, wall through and the like including weathering slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
M&L for providing cement concrete type B-1, 1:2:4 ( 20 mm graded aggregate ) as in roof kerbs / padding or similar work or mud stops rounded or chamferred on edges, complete all as specified and directed.
M&L for 75 mm thick PCC type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster on brick wall, racking out joints hacking for key scrubbing down with water and removal of debries to a distance exe 2.5 Km but n. exe 5 Km complete all as specified and directed.
M&L for rendering 10 mm thick on brick work/ concrete surfaces in cement mortar 1:6 on fair faces, finished fair & even complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coat of oil bound distemper over one coat of primer all as specified on walls surface including 2 mm thick cement base wall care putty complete all as specified and directed.
M&L for Rendering 15 mm thick in cement and sand mortar 1:4 on brick work or cement concrete surfaces of walls including finishing the surface even and smooth with using extra cement and mixing only integral water proofing compound as per manufacturer instruction complete all as specified and as directed by Engineer-in-Charge. Note:- WPC will be measured and paid seperately.
Supply only integral water proofing compound.
M&L applying two coats exterior emulsion weather coat paint of Apex (Asian Paint) / Weather coat (Berger) / Excel Top Guard (Nerolac) over newly plastered surface including preparation of wall surface over and including 1 mm thick cement base wall care putty & primer complete all as specified and directed.
M&L for 15mm thick rendering on brick work or concrete surfaces in CM 1:4 finished fair & even without extra cement, cement mortar complete all as specified and directed.
Material & labour for taking down, chipping and removing the loose, spailt, damaged cement concrete, cement mortor surfaces of RCC columns, beams, walls, chajjah etc and exposing the reinforced cement , wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface wash the re-bar with clean water for removing all rusts from the old re-bar surfaces, fixing new reinforcement for strengthening the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified bond coat on affected concrete surfaces and finally covering with Microconcrete and finally finishing the surface including necessary scaffolding and form work all as specified and directed. Make :- Dr. Fixit/Sunanda/Chemestik/Fosrok as aprooved. Note:- (i) Working up to 25 meters height from GL and all safety measures of worker shall be carried out. (ii) New reinforcement and MS Sections will be measured and paid separately.
S&F welded steel wire fabric, cut to length, fixed to steel members/ reinforcement steel, weigh per Sqm n exc. 4 Kg complete all as specified.
Taking down chowkats or frame, (wooden/aluminium/steel) not exceeding 1.5 sqm in each shutters (without taking off shutter from the frame) complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frame, (wooden/aluminium/steel) exceeding 1.5 but n exc 4 Sqm in each shutters (without taking off shutter from the frame) complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description not exc 1 Sqm each complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed by Engineer-in-Charge
S&F well seasoned 2nd class hard wood plan, solid, straight chowkat and frames, wrought framed, rebate on the solid rounded or chamfered, put together with glue pinned at joint complete all as specified and directed by Engineer-in-Charge
S&F for Mild steel work Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 as in small articles like angle iron framing work for manhole, rungs/steps in man hole all as specified.
M&L for plain cement concrete 1:3:6, type C-1 (using 20 mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary formwork complete all as specified and directed by Engineer-in-Charge
M&L for preparing new surfaces of wood and woodbased marterial, steel and iron works of any description and girth treating ends of post back of chowkats etc, area tarred exc 0.1 sqm but n exc 0.5 sqm each with tar or coal tar black paint complete all as specified and directed by Engineer-in-Charge
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified.
S&F 30 mm thick second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc , divided in to square with plain chamferef or rounded mitred and rebate sash bars, any numbers edges of framing plain, chamfered or rounded, size / section of members of shutters shall be as specified in SSR Part I section 8 clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge
S&F 30 mm thick second class hardwood glazed shutters as in windows/vertilators open rebateed and prepared to received mitred aand secured sash bars any numbers edges of fsdraming plain chamfered of rounded in SSR Part I Section 8 caluse 8.24 (b).complete all as specified and directed by Engineer-in-Charge
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise desceribed over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded , complete all as specified and directed.
M&L for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded , complete all as specified and directed.
S&F for anodised aluminium frame for doors, windows, ventilators, partition section with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F for anodised aluminium work for doors, windows any type sliding or fixed, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. complete all as specified.
S&F in repairs aluminium anodized grill weight of 3.13 Kg per Sqm (min) with suitable aluminium anodized frame of F/H section of 0.297 Kg per Meter (min) with suitable fixing screws / attachment etc complete all as specified and directed.
S&F for PVC door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with MS square tube, suppling & fixing in opening as per specn & drg
S&F for factory made solid PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm with stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified.
S&F 75 mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge
S&F 100 mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed by Engineer-in-Charge
S&F 100 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge
S&F 150 mm size Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge
S&F 150 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F 100 mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge
S&F Aluminium anodised sliding door bolt 300m long, with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, 300 mm long, mild steel, rat tail rod pattern springs including roller and roller plates complete all as specified and directed by Engineer-in-Charge
S&F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm in steel window clips and wooden beading in wooden joinery complete all as specified and directed.
Hacking out old broken glass (any thickness size, quality or description) from wooden frames or stone, concrete or bricks round, glazed with putty or fixed with bedds complete all as specified and directed by Engineer-in-Charge
S&F 3 mm thick sheet glass , ordinary quality and glzing with oil putty/timber bedds in square n. exc. 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge
S&F 3 mm thick sheet figured glass, ordinary quality and glzing with oil putty/timber bedds in square n. exc. 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge
S&F 4.8 mm thick sheet glass ordinary quality and glazing fixed to aluminium joinery with and including neoprene beading area of each pane exc 0.5 Sqm to 1 sqm
Demolition stone slab and tiles of any description or and thickness in floors, aprons etc including cement mortar bedding laid bedded and pointed in any mortar complete all as specified and directed.
M&L for granite (of any type) work (table rubbed and polished) 20 mm thick as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 20 mm thick screed bed in cm 1:4, complete. (Note : Screed bed will not be measured and paid separatel
M&L for 75 mm thick cement concrete 1:4:8, type D-2,(using 40 mm graded stone aggregate) as in Sub base for path / flooring complete all as specified and as directed.
M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
M&L for Chequered cement concrete coloured tiles 30 cm x 30cm x 20 mm thick with gray cement and pigment, set, jointed and pointed in neat cement slurry laid over and including 20 mm thick screed bed in CM 1:4 as in floors complete all as specified and directed. (Note : Screed bed will not be measured and paid separately)
M&L for exterior grade outdoor coloured floor tiles (heavy duty) of tactile series of size 600 x 600 x 15 to 16mm laid over and including 20 mm thick screed bed in CM 1:6 and jointed in cement mortar to match the colour of floor complete all as specified and directed.
Dismantling post or struts (wood/steel or RCC) any section incl taking out embedded portion and making good distrubed on normal ground in concrete, brick works masonary complete all as specified and directed.
S&F mild steel section as in posts and struts / fillets in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets ( for securing ire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified and directed.
S&F mild steel work as framed works such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes,framed guard bars barred iron doors ladders, framed balusters walk ways railing, framed work of water tanks, framed and hung as gates including pintle hinges, stops, hand made sliding sliding bolts etc complete all as specified and directed.
S&F Mild steel screw bolts (machine made) of 10mm dia of sank with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
M&L for dismantling fencing wire mesh any type complete all as specified and directed.
Fixing only chain link fencing of description fixed to steel post with mild steel flat & nut bolt etc. Note: (i) Supply only fencing, will be measured and paid separately. (ii) Supply and fix mild steel nut bolt, line wire and flat will be measured and paid separately.
Supply only chain link fencing made of galvanized steel wire apature of size as directed, made up into mattresses or cages lapped wired conforming to IS 2721 all as specified & directed. Note:- Fixing only fencing will be measured and paid separately.
M&L for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down mild steel barbed wire of any descreption from post etc complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Note :- Each line wire to be measured)
Restraining / resecuring including making good staples galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossings with and provn of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed. (Note: Each line wire to be measured.)
Dismentling and taking out existing unserviceable street light fittings / flood lights of any type from pole / bldgs incl brackets and electric connections complete
Supply & fix RGB / RGBW surface mounted Narrow / Medium (10/30°) beam Linear Flood luminaire which suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high / mid power LEDs, should consists of antiaging and antiUV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 50W+ 10% at steady state full intensity, Luminaire luminous flux range of 4400- 4600 Lumen. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v / 48V power supply with suitable integral / non- integral power supply unit. Luminaire should be compatible to DM X 512 control protocol. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply & fix RGB/RGBW surface mounted Narrow / Medium (10/30°) beam Linear Flood luminaire which suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 100W+ 10% at steady state full intensity, Luminaire luminous flux range of 9000- 10000 Lumen. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
Supply & fix RGB / RGBW surface mounted Narrow / Medium (10/30°) beam Linear Flood luminaire which suitable for outdoor applications of Facade Lighting, depending on Client and site requirement. Luminaires should be enabled with high/mid power LEDs, should consists of anti-aging and anti-UV high optical efficiency temperature resistant lenses, suitable for architectural lighting as per site requirement. Power consumption should be 120W+ 10% at steady state full intensity, Luminaire luminous flux range of 10,000.00 - 12,000.00 Lumen. Power factor of complete luminaire 0.90, at full intensity. Luminaire should be compatible for DC24v/48V power supply with suitable integral/non- integral power supply unit. Luminaire should be compatible to DMX512 control protocol. The luminaire should have powder coating extruded aluminium housing. Ingress Protection IP 66 and above. Impact resistance level IK 07. Operating Temperature: -10°C to +50°C, Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. Manufacturer should submit >> Design Simulation, Technical Data Sheets , LM79, LM80 Reports , Fixture IP Testing Report as Separate , Should have its Inhouse NABL Accredited Testing Lab with in its own Manufacturing Unit, all technical Parameters should comply IS 10332 Standards Note :-The contractor should take approval of techincal specification of luminaries and driver from department before procurement .
S&F cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paints complte all as specified and directed.
Supply, installing, testing and commissioning in replacement factory made, tested, CPRI approved powder coated Timer panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm), cubical compartmentalized , out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet , 40 x 40 x 6 mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50 x 50 x 6 mm, overall powder coated, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01No (v) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole , Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos Note - Plateform of panel fixed with PCC 1:4:8 type D-2 with 40mm graded crused stone ,15 cm thick in foundation,brick work in CM 1:6 with sub class B old size bricks ,rendring 15 mm thick in CM 1:6 on exposed surface and 100 mm thick PCC padding 1:3:6,type C-1 using 20mm graded crushed stone aggregate on Top and grouting bolts etc for panel.The plate form shall be such that it is of a height 45 cm above the nearest road level. All out going feeder shall be connected by cable through suitable size gland plate/glands. All MCCB with adjustable protection for over load and short circuit protection and confirming to IEC60947-II/IS 13947 -II (Latest Version). The MCCBs shall have spreader links and barriers as standard feature of manufacture.
M&L for Preparation of old painted surfaces of LT steel tubular pole 9/11 mtrs long and applying one coat aluminium paint from bottom to top including re writing pole numbering in 8 cm height with one coat synthetic enamel paint complete all as specified & directed by Engineer –in-Charge.
Supply and laying or fixing street light connection, 1100 volts grade heavy duty cable with PVC solid insulated aluminium conductor served with an inner sheathing PVC tape and over all PVC sheathed 6 Sqmm 2 core nominal cross section complete all as specified and directed.
S&F rigid PVC line spacer, suitable for 5 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
S&F rigid PVC line spacer, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300 mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
m/s pal associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .