CWE (AF) TUGHLAKABAD
Headquarters CWE AF Tughlakabad, Air Force Station, Tughlakabad, PO Sangam Vihar, New Delhi 110 080
SPECIAL REPAIR TO CERTAIN ELECTRICAL EQPT, AC DUCT AND REWIRING IN CERTAIN BUILDING AT 54 ASP UNDER GE (AF) GURGAON NO 1
2026_MES_776453_1
CWE/TKD/GUR/TOKEN-88 OF 2025-26
Open Tender
Electrical and Maintenance Works
270 days
GURGAON
As per NIT.
7 documents required · 7 mandatory
₹1,000
GE (AF) GURGAON NO. 1
₹1.4 L
Yes
4 Jul 2026
4 Jul 2026
3 Aug 2026
4 Jul 2026
1 Aug 2026
25 Jul 2026
6 Jul 2026 - 13 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, install, testing and commissioning of Eco friendly Generating Set Diesel Engine driven of capacity 75 KVA/ 60 KW at 0.8 PF or nearest higher size 415 volts AC, 3 phase, 50 Hz 4 wire, directly coupled alternator and engine, water cooled common base platform with inbuilt fuel tank and including all excavation, PCC foundation, anti vibration pads/dampers as per manufacturer instructions and as directed by manufacturer. The DG set shall work at ambient conditions of Gurgaon and produce specified out put.The derating factors, if any, shall be taken in to consideration while arriving the capacity to give specified out put. The DG set shall be factory assembled by the OEM of the engine manufacturer and all components shall be accommodated in enclosure and other accessories comprising of the following:-
(A) Engine : Eco friendly emmision limits for diesel engines as per CQAM Direction No. 76 letter folio No. A-11018/01/ 2021-CQAM/ 15322-15331 Dated: 29.09.2O23 government of India and noise level (CPCB - IV norms compliances) diesel Engine confirming to BS/IS standard, confirming to BS:5514/DN-6271 / IS 10002/ISO-3046, of suitable BHP as per the standard design of OEM to run the DG set in full load / 110% overload with out any change of out put parameters, (not less than 608 BHP),1500 RPM, water cooled complete under NTP condition, with a provision for 10% over load for one hour on 12 hours continuous running.
(B) Alternator : Synchronous alternator 75 KVA, 1500 RPM, 415 Volts, 50 Hz, 3 phase system self excited, self regulated, self ventilated in brushless design provided with suitable automatic voltage regulator with ± 1% all load between no load to full load and power factor 0.8 to unity with 10% overload capacity for one hour in any 12 hours of operation without exceeding temp rise limit, Confirming to BS:5000/IS 4722 with standard design with IP 23 protection and class of "H" insulation & having surge separator for protection of alternator for reverse supply.
(C) Acoustic enclosure : Acoustic enclosure drip proof & screen protected meeting stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions with air inlet louvers powder coated.
(D) AMF panel : Supply, install, testing and commissioning of AMF panel indoor type suitable for 75 KVA DG set, totally enclosed with sheet metal enclosure with sheet (CRCA) duly powder coated, dust & vermin proof made out of min 2.0 mm thick sheet | 2 | Each | - | - |
| 2 | Supply, install, testing and commissioning of Eco friendly Generating Set Diesel Engine driven of capacity 20 KVA/ 16 KW at 0.8 PF or nearest higher size 415 volts AC, 3 phase, 50 Hz 4 wire, directly coupled alternator and engine, water cooled common base platform with inbuilt fuel tank and including all excavation, PCC foundation, anti vibration pads/dampers as per manufacturer instructions and as directed by manufacturer. The DG set shall work at ambient conditions of Gurgaon and produce specified out put.The derating factors, if any, shall be taken in to consideration while arriving the capacity to give specified out put. The DG set shall be factory assembled by the OEM of the engine manufacturer and all components shall be accommodated in enclosure and other accessories comprising of the following:-
(A) Engine : Eco friendly emmision limits for diesel engines as per CQAM Direction No. 76 letter folio No. A-11018/01/ 2021-CQAM/ 15322-15331 Dated: 29.09.2O23 government of India and noise level (CPCB - IV norms compliances) diesel Engine confirming to BS/IS standard, confirming to BS:5514/DN-6271 / IS 10002/ISO-3046, of suitable BHP as per the standard design of OEM to run the DG set in full load / 110% overload with out any change of out put parameters, (not less than 608 BHP),1500 RPM, water cooled complete under NTP condition, with a provision for 10% over load for one hour on 12 hours continuous running.
(B) Alternator : Synchronous alternator 20 KVA, 1500 RPM, 415 Volts, 50 Hz, 3 phase system self excited, self regulated, self ventilated in brushless design provided with suitable automatic voltage regulator with ± 1% all load between no load to full load and power factor 0.8 to unity with 10% overload capacity for one hour in any 12 hours of operation without exceeding temp rise limit, Confirming to BS:5000/IS 4722 with standard design with IP 23 protection and class of "H" insulation & having surge separator for protection of alternator for reverse supply.
(C) Acoustic enclosure : Acoustic enclosure drip proof & screen protected meeting stringent MOEF/CPCB norms of 75 dBA @ 1 mtr at 75% load under free field conditions with air inlet louvers powder coated.
(D) AMF panel : Supply, install, testing and commissioning of AMF panel indoor type suitable for 20 KVA DG set, totally enclosed with sheet metal enclosure with sheet (CRCA) duly powder coated, dust & vermin proof made out of min 2.0 mm thick sheet | 1 | Each | - | - |
| 3 | Supply installation testing and commissioning of Voltage stablizer for automatic operation three phase naturally oil cooled (ONAN) outdoor type & designed for input variation between 300 V to 480 V with out put voltage stablized at 415V with accuracy of ± 1% and speed correction 8 Volts per second and capacity of 200 KVA as per IS 9815/IS 2026. Class `H' insulation with digital temperature/ voltage /current display overload for 100% unbalance etc all as specified and directed including short circuit , high voltage trips protection single phase preventor, low voltage trip auto visual alarm and surge spike suppress and porcelain bushing (conforming to IS 3347) along with cable junction boxes with top or side entry and independent phase contropl etc complete with first fill of transformer oil all as specified and as directed. | 1 | Each | - | - |
| 4 | All as per item No - 3.00 here in before but of capacity 300 KVA. | 1 | Each | - | - |
| 5 | All as per item No - 3.00 here in before but of capacity 400 KVA. | 1 | Each | - | - |
| 6 | All as per item No - 3.00 here in before but of capacity 50 KVA. | 1 | Each | - | - |
| 7 | All as per item No - 3.00 here in before but of capacity 75 KVA. | 1 | Each | - | - |
| 8 | Supplying, installing, testing and commissioning of submersible pumping set suitable for 200/250mm bore well with submersible motor 3 phase 415 volts, 2.24 KW ( 3.0 HP) coupled with pump 5-79 meter head, discharge 70 - 300 LPM suitable for 200 mm boring complete all as specified and directed.
Note: (i) The length of submersible cable connected alongwith motor supplied by manufacturer shall not be measured and paid for separately.
Make :- Kirloskar (b) KSB (c) Wilo Mather (d) M/s Jyoti or techno-commercially equivalent as per list of make in PS. | 2 | Each | - | - |
| 9 | Supplying, installing, testing and commissioning of submersible pumping set suitable for 200/250mm bore well with submersible motor 3 phase 415 volts, 5.6 KW ( 7.5 HP) coupled with pump 55-140 meter head, discharge 150-330 LPM suitable for 200 mm boring complete all as specified and directed.
Note: (i) The length of submersible cable connected alongwith motor supplied by manufacturer shall not be measured and paid for separately.
Make :- Kirloskar (b) KSB (c) Wilo Mather (d) M/s Jyoti or techno-commercially equivalent as per list of make in PS | 1 | Each | - | - |
| 10 | Supplying, installing, testing and commissioning of submersible pumping set suitable for 200/250mm bore well with submersible motor 3 phase 415 volts, 7.46 KW (10 HP) coupled with pump 65-170 meter head, discharge 150-330 LPM suitable for 200 mm boring complete all as specified and directed.
Note: (i) The length of submersible cable connected alongwith motor supplied by manufacturer shall not be measured and paid for separately.
Make :- Kirloskar (b) KSB (c) Wilo Mather (d) M/s Jyoti or techno-commercially equivalent as per list of make in PS | 2 | Each | - | - |