| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 6 O YASHODA NAGAR KANPUR UP 208011 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208011 | ₹1.3 Cr | L1 | Accepted-AOC BEING LOWEST BIDDER |
| 2 | L2₹1.4 Cr+₹3.5 L (2.67%)Rejected-Finance | ₹1.4 Cr+₹3.5 L (2.67%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.6 Cr+₹27.4 L (20.7%)Rejected-Finance NO 403 BENGALI COLONY RANJHI JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | ₹1.6 Cr+₹27.4 L (20.7%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | Rejected-Technical 403 NARSINGH NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | JABALPUR | MP | 482005 | - | - | Rejected-Technical BEING TWO CLASS BELOW THE ELIGIBLE CLASS |
| 5 | Rejected-Technical 28 PRAGATISHEEL COLONY NARMADA ROAD JABALPUR 482001 M P | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | - | - | Rejected-Technical NOT ENLISTED IN BOTH a(i) and b(i) CATEGORY AS PER NIT |
Tender Value
₹1.2 Cr
EMD Value
₹1.9 L
Closing Date
31 Jul 2023, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
SPECIAL REPAIR TO MAG NO. 02 AND 12 OF AMN SUB DEPOT, COD JABALPUR UNDER GE (East) JABALPUR
2023_MES_602849_1
82625/E8
Open Tender
Civil Works
Item Rate
270 days
JABALPUR
AS PER NIT
8 documents required · 8 mandatory
₹1,000
Yes
GE EAST JABALPUR
₹1.9 L
Yes
12 Jan 2024
12 Jun 2023
1 Aug 2023
12 Jun 2023
31 Jul 2023
26 Jun 2023
23 Jun 2023 - 24 Jun 2023
Amount
Demolition of cement concrete of any description (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) including removal of debris to out side MD land complete all as specified & directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete including removal of debris to out side MD land complete all as specified & directed.
Hard core of stone (granite/ basalt/ trap) boulders or broken stone of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete all as specified and directed. Note:- Reinforcement shall be measured & paid for separately under respective item of BOQ.
S & F for cement concrete tiles with grey cement and no pigments (250mm x 250mm x22-25mm thick) machine pressed, set, jointed and pointed the joint with polymer based cement grout in roof & cut & polished over 15 mm thick screed in cement mortar 1:4 complete all as specified & directed
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection finished even and smooth without using extra cement forming joints to full depth at every 3M intervals and at every change of direction and filing with bitumen sand mixture 1:3 by weight complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base finished even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling, mass concrete and sub base of floors, path/ paving etc complete all as specified & directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate in roof padding, roof kerbs or mud stops, rounded or chamfered on edge including necessary form work if required complete all as specified and directed.
Removing of surplus soil over the roof in the nearby low lying area complete all as specified and directed.
M&L for granolithic concrete 1:1:2 floor topping 30mm thick; laid over cement concrete subfloors etc. and finished to an even and fair surface complete all as specified and as directed.
M&L for 20 mm thick Wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardener) complete all as specified and directed. ( Note : (a) Wearproof topping shall be laid while the granolithic concrete is still green. (b) Metallic hardener shall be measured and paid for separately as "Supply only".)
Supply only metallic floor hardener of approved Make(as approved by GE)complete all as specified and directed.
Dismantling brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/ loose soil complete all as specified and directed.
Excavation over areas, n exc 1.5m deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation over areas, exc 1.5m deep but n.exc 3.0 m and getting out in soft/ loose soil complete all as specified and directed.
Excavation over areas, exc 3.0 m deep but n.exc 4.5 m and getting out in soft/ loose soil complete all as specified and directed.
M&L for moorum / red bajri filling in, floor or pavings, laid in layers not exceeding 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m but n. exc. 100 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L rendering 15mm thick in cement plaster 1:6 on surfaces fair faces of brick work and surface finished even and fair without using extra cement all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of AC (corrugated or semi corrugated etc.) sheets including ridges in roof coverings complete all as specified & directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering and ridge complete all as specified and as directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc. Fixed with L-type or screws J-type or cranked hook bolts complete all as specified and directed.
M&L for Asbestos cement one piece plain angular ridge 6mm thick Fixed with L-type or Jtype or cranked hook boltscomplete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in lintels upto 1.50M clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60cm in height, copings, kneelers, apex stones, bed plates etc and the like including weathering slightly rounded/ chamfered angles with & including necessary use and waste of form work for fair faces of concrete, complete all as specified and directed.
M&L for RCC (design mix) M-25 (using 20mm graded crushed stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles, raft etc and mass concrete complete all as specified and directed.
M&L for RCC (design mix) M-25 (20mm graded crushed stone aggregates) as in walls, retaining wall, basement wall etc. complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified & directed.
M&L for formwork to sides of walls, abutments, retaining walls, parapets, and staircase or similar work including attached pilasters and buttressesetc. for fair finished square, rectangular or polygonal surfaces of concrete complete all as specified & directed.
M&L for mild steel work conforming to Fe-290 Gde -165 as in hand rail, half round or other steel section or core for wooden hand rail strait portion, drilled and countersunk for balusters running bars for doors, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete all as specified and directed.
M&L for mild steel TMT bars 8mm dia as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia, and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Supply and fix rolled mild steel sections conforming to Fe- 410-W (Gde E-250) quality-A as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates etc complete all as specified & directed.
M&L for mild steel conforming to Fe.290.Gde-E-165 in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings and similar work complete all as specified & directed.
S&F of expanded metal not exceeding 4 Kg per Sqm in weight, cut to length, bent to shape required and tying with & including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples to brick wall/ stone block or slab wall complete all as specified & directed.
S&F rolled mild steel section for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W(Gde-E-250) quality-A complete all as specified and as directed. Note : 1. The rates quoted allow for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete. 2. Truss design shall be got done by the contractor duly wetting by Government Engineering College/NIT and expansion including in quoted rates.
Supply and fix pre-painted galvalume aluminium zinc coating GI based 0.50 mm thick (AZ-150) corrugated steel sheet of any colour having minimum tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws/ L or J type or cranked hook/ bolts as complete all as specified & directed. Make: Tata Blue Scope Steel Ltd or M/S Cril Colour Roof India Ltd. or Everest Industries Ltd or equivalent brand of other Make as approved by GE from list of make attached with tender documents.
Dismantling timber scantling 40 Sqcm and over in section in any position as in framed work complete all as specified and directed.
M&L for preparation of new surfaces of iron/ steel of any description over 10 cm width or girth and applying two coat of synthetic enamel paint of colour as approved by GE over and including a coat of red-oxide primer complete all as specified & directed.
M&L for preparation of new surfaces of iron/ steel of any description n.exc 10 cm width or girth and applying two coat of synthetic enamel paint of colour as approved by GE over and including a coat of red-oxide primer complete all as specified & directed.
M&L for preparing newly plastered surfaces of walls and applying three coats of colour wash complete all as specified and directed.
Removal of existing deteriorated decayed tarfelt or any other treatment including PCC padding, loose surface and removing to debris to a distance n.exc. 50 mtr depositing where directed complete all as specified.
M&L for 10mm thick rendering over roof surfaces in CM 1:4 with using liquid water proofing compound @ 2% by wt of cement or as per manufacturer's instructions, finished even and smooth without using extra cement complete all as specified & directed. Note: WPC shall be measured and paid separately as "Supply Only" under respective item of BOQ.
M&L for applying evenly tack coat of hot blown bitumen 85/25 grade conforming to IS-702 @ 1.20 kg/sqm after cleaning the surfaces over & including a coat of bitumen primer @ 0.30 litre/ sqm consisting of 3/4 part bitumen of grade 85/25 and 1/4 part of kerosene oil on the top of prepared roof surfaces complete all as specified & directed.
M&L for unrolled over the bitumen coated surface, 3mm thick spun bonded non-woven polyester reinforced APP modified water proofing membrane weighing not less than 3.0 Kg/Sqm with minimum over lap of 100mm and over lap shall be sealed by flame as per manufacturer's instructions complete all as specified & directed. Note:- Suitable embedment of APP modified water proofing membrane shall be ensured into walls/parapet walls, special care shall be taken in laying APP modified water proofing membrane in situations such as drain/ expansion joints etc.
Taking down cement plaster etc on brick walls/ concrete (ceiling) surfaces of any descriptions including racking out joints, hacking for keys, scrubbing down with water and disposal of unserviceable materials to out side of MD land complete all as specified & directed.
M&L for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed.
M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed.
Supply only water proofing compound (liquid) ISI marked of make as approved by GE complete all as specified & directed.
Taking down Chowkhats or frame with shutter without taking off shutter from the frame) area exc 1.50 sqm but n.exc 4 sqm each and removal complete all as specified & directed.
M&L for IInd class (Indian Sal, Bijasal, Hollock or Benteak) hardwood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints complete all as specified & directed.
Supplying and fixing 40mm thick flush shutters of make as approved by GE, solid core construction, with block board core and plywood face panels, both face covered with decorative face veneers with lipping/frame to match complete all as specified & directed.
M&L 2 mm thick copper sheet fixed to flush shutter on both faces (inner and outer) with all fitting arrangements complete all as specified and directed.
S&F 300 mm long brass sliding door bolt with sand or die cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
S&F 150 mm long brass handles, cast type, plolished bright complete all as specified and directed.
Supplying & fixing 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
M&L for preparation of new surfaces of any description wood,steel , Iron, concrete, brick , stone etc materials of over 10 cm width or girth and applying two coat fire resistant paint as approved by GE complete all as specified & directed.
M&L for preparation of old surfaces of any description wood,steel , Iron, concrete, brick , stone etc materials of over 10 cm width or girth and applying one coat of fire resistant paint as approved by GE complete all as specified & directed.
Supply and fix in repair 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floor with & including necessary clamps of requird size etc complete all as specifed & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 15mm bore of pipe complete all as specified and as directed.
Supply & fix 15mm bore medium grade galvanised steel tubes with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified & directed.
Refixing old steel water tubing 15mm dia with and including new GI fittings and connected to new or old positions of walls, ceilings, floors etc complete all as specified and directed. Note: Old GI pipe obtained from taking up or down here-in-before shall be re-used after necessary cleaning.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 20mm bore of pipe complete all as specified and as directed.
Supply & laying of 20mm bore medium grade galvanised steel pipe with all fittings and fixed complete complete all as specified & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 25mm bore of pipe complete all as specified and as directed.
Supply & laying of 25 mm bore medium grade galvanised steel pipe with all fittings and fixed complete complete all as specified & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 40mm bore of pipe complete all as specified and as directed.
Supply & laying of 40 mm bore medium grade galvanised steel pipe with all fittings and fixed complete complete all as specified & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 50mm bore of pipe complete all as specified and as directed.
Supply & laying of 50 mm bore medium grade galvanised steel pipe with all fittings and fixed complete complete all as specified & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 63mm bore of pipe complete all as specified and as directed.
Supply & laying of 63 mm bore medium grade galvanised steel pipe with all fittings and fixed complete complete all as specified & directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 80mm bore of pipe complete all as specified and as directed.
Supply & laying of 80 mm bore medium grade galvanised steel pipe with all fittings and fixed complete complete all as specified & directed.
Supply & fix in repairs, 20mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Supply & fix in repairs, 25mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Supply & fix in repairs, 50mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
Dismantling of water tank of any description of capacity exc. 250 litres but not exc. 500 litres, removing to store or from the site complete all as specified and as directed.
Supply and fix 500 ltrs capacity rotational moulded polyethylene water storage tank double layered (cylindrical vertical with closed top) hoisted and fixed in position including dismantling of old unserviceable water tank and removing to store complete all as specified & directed.
Supply & fix, 15 mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high dencity plastic ball, screwed for iron pipe or brass ferrule complete all as specified & directed. (Note-Min weight should not be less than 210 gms)
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 50 sqmm, 3.5 core including jointing materials such as cable glands & lugs etc after taking out the old unserviceable cable and testing on completion complete all as directed.
Supply and spreading clean and dry fine sand free from sharp materials (unwashed) laying in trenches around the cable for cushioning in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness complete all as specified and as directed. ( Note : Punned thickness shall be considered for payment purpose.)
Supplying and laying Fly ash sub class "B" bricks locally available laid flat with width equal to the length of brick, in trenches over sand cushioining for cable protection complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in surface channel and drain including saucer drain and toe wall etc complete all as specified and directed.
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, sockets, light fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc as per existing complete all as specified & directed.
M&L for flame proof point wiring concealed type with 1.50 sqmm size FRLSH , single core, multistranded copper conductor unsheathed PVC insulated 1100 V grade cable drawn into and including ERW in stove enamelled steel conduit of 20 mm dia sleeves and caps of adequate width and length with accessories and fitting like bend, elbows, crosses, wall crossing, Flame Proof junction boxes, steel flexible conduit for Flame Proof ceiling rose/junction boxes to light point etc for one light point/fan point controlled by one switch and with continuous earth wire green colour as one number cable 1.5 sqmm copper conductor PVC insulated unsheathed connected to earth dolly, one flame proof light/fan/bell point controlled by one way switch including making chases for concealed wiring and making good the disturbed surfaces to match with the existing specifications complete all as specified & directed.
M&L for flame proof point wiring concealed type with 2.50 sqmm size FRLSH , single core, multistranded copper conductor unsheathed PVC insulated 1100 V grade cable drawn into and including ERW in stove enamelled steel conduit of 20 mm dia sleeves and caps of adequate width and length with accessories and fittings like bend, elbows, crosses, wall crossing for one light point/fan point controlled by one switch and with continuous earth wire green colour as one number cable 2.5 sqmm copper conductor PVC insulated unsheathed connected to earth dolly and to be connected to flame proof one 5 pin, 5/15 Amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch including making good the disturbed surfaces to match with the existing specifications complete all as specified & directed.
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including ERW rigid heavy duty steel conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith steel conduit and its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including ERW rigid heavy duty steel conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith steel conduit and its accessories shall be measured and paid as one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
M&L for provision of sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6 sqmm drawn in and including ERW rigid heavy duty steel conduit steel conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed. Notes:- (i) Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith steel conduit and its accessories shall be measured and paid one unit length. (ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/ copper thimbles. (iii) Colour coding for wiring/ bus bar/ main connection shall be followed .
Supply & fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified & directed. (Note:- Two light point controlled by one Flame Proof switch)
Supply & fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified & directed.
Supply and fixing LED light fitting 1X20 Watt flame proof, CMRI certified and recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass, with LED tube light fixtures, driver, holders, connector etc. with hook mounting and wire mesh complete with all accessories, prewired and including connecting up with three core flexible copper conductor cable with suitable size conduit complete all as specified & directed.
Supply and fixing flame proof aluminium well glass LED light fitting 100 Watt , including connecting up with three core flexible copper conductor cable with suitable size go through flexible 20 mm steel conduit complete all as specified & directed.
Supply and fixing LED light fitting 2X20 Watt flame proof, CMRI certified and recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. with hook mounting and wire mesh Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size conduit complete all as specified & directed.
Supply and fix in repairs, 150 watt Next generation, energy saving, environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting with system efficacy upto 150 lm/W & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Supply and fix in repairs, 45 watt new generation energy saving and environmental friendly long life LED security light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP65 protection and impact resistance of IK07 on bldg wall with and including pipe bracket made out of G.I tubing 32/40 mm dia bore medium grade ISI marked 1.20m long bent to shape & providing clamps 2 Nos made out of 50 x 6mm Flat iron/ MS clamps & 12mm dia bolts, nuts & washers etcand two coat painting of approved colour on brackets completely with and including synthetic enamel paint and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Supply and fix Distribution Board of MCCB made out of CRCA sheet, powder load line coated, vertical type, double door, 4 way including taking down old unserviceable any type MCCB DB, after cutting chases and making good the surface by necessary patch work and surface finish including making connections complete all as specified and directed.
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts complete all as specified & directed.
Supply & fix in replacement, double pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB DP of capacity 20 Amps 240 volts complete all as specified & directed.
Supply & fix in replacement, tripple pole and neutral sheet metal enclosure (AC box) with a three pin & earth plug and socket with one no. MCB TP of capacity 63 Amps 415 volts complete all as specified & directed.
Supply and fix TPN DB 8 way sheet metal enclosure, IP 43-IK 09 with metal door, 240/ 415 volts with copper bus bar of 100A and neutral bar, earth bar and cable ties for cable management all enclosed on standard steel sheet flush or surface mouting type factory fabricated complete all as specified and directed.
Supply and fix MCB DB SPN 8 way sheet metal enclosure, IP 43-IK 09 with metal door, 240/ 415 volts with copper bus bar of 100A and neutral bar, earth bar and cable ties for cable management all enclosed on standard steel sheet flush or surface mouting type factory fabricated complete all as specified and directed.
Supply & fix MCB SPN, 40 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed.
Supply & fix MCB SP, 6 to 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed.
Supply & fix MCB TPN, 63 Amps, 'C' series, 240 volts, 50Hz, 16kA complete all as specified & directed.
Supply & fix MCB TPN, 100 Amps, 'C' series, 240 volts, 50Hz, 16kA complete all as specified & directed.
S&F MCCB 4 pole, 415 V ,with thermal magnetic release, adjustable type 100 Amp with breaking capacity 16 KA including taking down old unserviceable MCCB of any type and capacity complete all as specified and as directed.
S&F in repair MCCB 4 pole, 415 V ,with thermal magnetic release, adjustable type 160 Amp with breaking capacity 36 KA including taking down old unserviceable MCCB of any type and capacity complete all as specified and as directed.
S&F in repair MCCB 4 pole, 415 V ,with thermal magnetic release, adjustable type 200 Amp with breaking capacity 36 KA including taking down old unserviceable MCCB of any type and capacity complete all as specified and as directed.
S&F in repair MCCB 4 pole, 415 V ,with thermal magnetic release, adjustable type 250 Amp with breaking capacity 36 KA including taking down old unserviceable MCCB of any type and capacity complete all as specified and as directed.
S&F in repair MCCB 4 pole, 415 V ,with thermal magnetic release, adjustable type 400 Amp with breaking capacity 36 KA including taking down old unserviceable MCCB of any type and capacity complete all as specified and as directed.
Cutting chases in brick walls, pinning in brick wall/ stone concrete block or slab walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc and making good as per existing, cutting not exceeding 10cm girth complete all as specified and directed.
S&F single pointed air termination aluminium rod 12 mm dia, 300 mm long with necessary fixing arrangements as per site requirements complete all as specified and directed.
S&F aluminium strip 25 mm x 3.15 mm complete with saddles and fixing screws as roof conductor complete all as specified and as directed.
S&F GI strip 32 mm x 6 mm buried in ground complete all as specified and as directed.
M&L Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. , 8mm dia. , 25 mm long hex. head screw complete all as specified and as directed.
M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI strip and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
M&L for earthing complete with galvansided steel earth plate electrode 600x600x6.0mm thick directly burried in the ground (earth pit not less than 2.25M deep below ground level) with top edge of earth plate not less than 1.50M deep below normal ground level, connected to galvanised iron wire 4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, 15mm bore GI pipe medium grade including necessary fittings for protection of earthing wire, watering pipe 20mm bore GI medium grade, concrete chamber in PCC (1:4:8) type D-2 using 40 mm grade aggregate, coping shall be in PCC (1:3:6) type C-1 using 20 mm grade aggregate and internal surfaces of concrete chamber shall be given 12mm thick plaster in CM (1:4), funnel with wire gauge of 22 gauge (0.63 mm) 8 mesh per linear including 50mm thick cover of RCC (1:2:4) type B-1 using 20mm grade stone aggregate reinforced with 8mm MS deformed bar @ 75 mm C/C both ways, char coal dust and common salt all as shown in electrical plate No. 3 of SSR Part-I (2009) including all necessary excavation & earth work and removal of surplus soil to a distance n. exc 50M and providing connection points with MS/ GI bolts & washers as required and connection from earth test point to earth electrode with same GI earth wire alongwith protection pipe and testing on completion complete all as specified and directed. Note:- GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
Schedule of credit amount of Rs. 3,06,898.00 to be deducted during AOC
M/s R.V. Constructions
J.P ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .