REPAIR/MAINT E/M SERVICES AND ALLIED WORK OF OFFICER AND JCO MD ACCN UNDER GE (W) JABALPUR
2026_MES_790521_1
9082/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹80,000
22 Sept 2026
22 Sept 2026
20 Oct 2026
23 Sept 2026
13 Oct 2026
6 Oct 2026
23 Sept 2026 - 1 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge. | 1,385 | Per Point | - | - |
| - | Taking down carefully main switches / distribution boards complete of any size and refixing after repair and MCBs SP /SPN or Cut out of any size all as required and directed at site | 120 | Each | - | - |
| - | Repair to point wiring with taking out the fault removing the u/s / brunt wire and repair with repalacemnt of wire jointing properly with connector and making the point serviceable (replacemnt of wire not more then 1.5 mtrs, junction box cover / connection of point is included in type cost of repair) and making the point serviceable all as required and directed at site | 530 | Each | - | - |
| - | M& L for comprehensive maintenance and repair to point wirring with taking out fault in the wiring and repair to the point wring and making the point wiring serviceable including following works (a) Checking proper working of wiring light or fan point (b) Checking of socket point/switch /holder point including replacement of unseviceable part (c) Replacement of unserviceable batten holder/ tube light/lamps/ ballast/bipin holder /fittings (d) Cleaning of tube light fitting ( e) Note : 1.Contractor has to depute two electricians including one helper with each electrician daily who will report to JE E/M in mes YARD under AGE E/M E/S. 2 Unserviceable parts to be measured & paid seperately under relevant item of Sch A. All Tools & Plants and ladder provided to electrician at site by The contractor. | 500 | Each job | - | - |
| - | Taking down the old unsv sub main wiring of any size all as required and directed at site | 650 | RM | - | - |
| - | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 20mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 450 | RM | - | - |
| - | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 6 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 150 | RM | - | - |
| - | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm drawn in and including rigid PVC conduit medium grade ISI marked not less than 25mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing finish complete all as specified & directed.
Notes:-
(i) Finished sub main wiring with two runs of 10.0 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit and its accessories shall be measured and paid as one unit length.
(ii) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles.
(iii) Colour coding for wiring/ bus bar/ main connection shall be followed . | 50 | RM | - | - |
| - | Supply & fixing in replacement of 25 mm dia non mettalic Rigid PVC conduit, ISI Marked conforming to IS : 9537 medium grade Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed. | 250 | RM | - | - |
| - | Supply & fixing in replacement of 20 mm non mettalic Rigid PVC casing caping conduit, ISI Marked Including all fittings like bends, elbow reducer, junction boxes, tee bell mouth fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including fixing on wall and making good the disturbed surface with cement mortar 1:3 and treated with distemper or colour wash to match with existing surfaces complete all as specified & directed. | 150 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
9082GP.pdf
Tender Documents • 0.41 MB
Tender9082SPPS.pdf
Tender Documents • 1.29 MB
BOQ_886202.xls
BOQ • 0.37 MB
SCH9082.pdf
Additional Documents • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .