Executive Engineer Works Division Nanded,ZP Nanded
At Tuppa Tq Nanded Dist.Nanded Primary Healath Center Making Moduklar Labour Room (Modular labour Room with Positive Pressure System,Roof and Wall Panel P.P.G.1 Scientific Door Pve Vinyl Flooring.BMW troly,Scrun Area,Electric Work ) Other Works.
2026_NANDE_1290040_13
ZPN/WD/NED/E.TEN15/Open/25-26
Open Tender
Civil Works - Others
Percentage
180 days
At Tuppa Tq Nanded Dist.Nanded
Please Refer Tender Document
5 documents required · 5 mandatory
₹590
₹15,000
16 Jul 2026
8 Jul 2026
14 Jul 2026
8 Jul 2026
13 Jul 2026
8 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and Erecting Pre Fabricated Steel Puff panel: Wall panel should be Steel PUF Panel should have two independent steel surfaces, freestanding structure, constructed from composite, free standing insulated steel Wall panels shall be made of GI 120GSM material having thickness not less than 0.6mm front and back PPGI steel 0.5mm thick. The core should consist of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3 and Thickness of panel for wall 50mm | 1 | Sq.m | - | - |
| 2 | Supply and Erecting Pre Fabricated Steel Puff panel: Celing panel should be Steel PUF Panel should have two independent steel surfaces, freestanding structure, constructed from composite, free standing insulated steel Wall panels shall be made of GI 120GSM material having thickness not less than 0.6mm front and back PPGI steel 0.5mm thick. The core should consist of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40kg/m3 and
Thickness of panel for wall 50mm | 1 | Sq.m | - | - |
| 3 | Providing and Applying Coating: Filling of all Joints and cavities with Esdee Polyster putty for metal surface and Sanded Flush to provide a jointless finish primer with metal primer to give a bonding of paint and then sprayed with a water based liquid plastic aseptic and self sterilizing wall coating system , which protects against the growth of micro-organism, such as mould,funbgi, yeast and bacteria on its surface, Equivalent to a minimum dry film thickness of 300 micron. | 1 | Sq.m | - | - |
| 4 | Supply & Erection of Vinyl Flooring 2mm thick antistatic with thermal welding of joints to provide seamless Antisatict flooring system, with perfectly curved flush covings, all joints welded properly with same material .(Roll) | 1 | Sq.m. | - | - |
| 5 | SITC OF :Hermatically Sealed
Double Swing Door MOC : SS 304 Door Size : 1500mm x2100mm: MOC - SS 304 / 0.8 mm Sheet for Door Leaf Sheet MOC - SS 304 / 1.2mm thick for Door Frame Doors are designed to fit flush into the wall panel system on both sides and are supplied in different dimensions. Doors are fabricated from GI P. Coated Shutter has sheet thickness of 0.8mm and the frame of 1.2mm. Standard 50 mm panel has frame width of 50 mm and shutter width of 45mm. Doors are available in various sizes as per the requirement of the client. The following accessories are a part of the door: Shutter Thickness: 45 mm thick Stainless steel hinges Stainless Steel 'D' type of handles on pull side Stainless steel push plates on push side. Standard arm door closure (TS-68) View panel along with self adhesive tape and silicon sealant Both side key operated locking arrangement Automatic | - | Nos | 0.29 | - |
| 6 | SITC OF :Peripheral Lights / OT Luminaries : LED Type: Technical specifications:
1. Recess mounted IP54 Protocol
2. Non-hygroscopic peripheral lights.
3.Size : 2ft x 2ft 4 . Sitable watts for required proper Illumination for Operation | - | Nos | - | - |
| 7 | SITC OF : LAF- SYSTEM CONTROL INTERFACE (3 Panel System):Theater Control Interface(TCI)With inside MOT controlling: Designed to have maximum controls within the theatre, will be located on a membrane type control panel mounted in the theatre wall. It compromises
1. Digital Real time clock
2.Digital Laps timer
3.Set of Temperature controller, Humidity controller
4.OT Light control
5.Medical Gas Alarm
6.Hands free telephone
7.HEPA pressure monitor (Analog &/Or Digital) The panel will incorporate all the necessary controls for the correct operation and monitoring of the equipment and services with following feature -( One Pressure monitoring required out side every OT) | - | Nos | 0.29 | - |
| 8 | SITC OF : Surgical Scrub Automatic type MOC: SS 304 Size 1500*1000*600 mm:
1. Capacity - Two (2) Bay Scrub Sink
2.Configuration - floor mounted
3.Operations - Manual / Mechanical through Floor switch &/Or Elbow action
4. Automatic sensor based operations.
5. Hardware - Mixture valve (1 No.) and Solenoid valves (2 Nos.)
6.The scrub sink is provided with front access panel for ease of maintenance & repair
7. Automatic Operation Specifications: - Infrared Photo sensor Digital Timer with user defined time interval of 1,3,5, & 10 min
8.MOC : Stainless Steel Grade 304, Anti-splash metal body construction polished finish
9. Mixer arrangement for hot and cold water, Hot water source at Client end | - | Nos | 0.29 | - |
| 9 | Providing Factory fabricated cut- out in Wall & Ceiling panels for Electrical fittings & accessories. | - | Nos | - | - |
| 10 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel
formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper
conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in
provided trench/ pipe as per specification no. CB-LT/CU | - | RMT | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.28 MB
BOQ_2256206.xls
BOQ • 0.27 MB
DETAIL_TENDER_NOTICE_Nanded.pdf
Tender Documents • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .