Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹22.6 L
EMD Value
₹45,300
Closing Date
6 Jul 2020, 4:00 pmClosed
Executive Engineer JDA, Division No. I Rail Head C
Executive Engineer JDA, Division No. I Rail Head Complex, Jammu
Construction of Tube Well/ Pump Room Building for Water Supply Scheme JDA Housing Colony, Birpur.
2020_HAUDD_98662_1
JDA-I/2020-21/e-NIT/29 Dated 20.06.202
Open Tender
Civil Works
Item Rate
90 days
RHC
As per SBD
3 documents required · 3 mandatory
₹1,000
Vice Chairman, Jammu Development Authority, Jammu
₹45,300
Yes
8 Jul 2020
20 Jun 2020
7 Jul 2020
20 Jun 2020
6 Jul 2020
20 Jun 2020
Amount
Earth work in excavation by manual means over areas (Exceeding 30 em and upto 1.5 mtr in depth, 1.5 mtr in width as well as 10 sqm. on plan) including disposal of excavated earth upto 1 mtr from cutting edge, disposed earth to be levelled and neatly dressed in : All kinds of Soil
Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (Not exceeding 1.5 mtr in width) and for shafts, wells, cesspits and the like not exceeding 1 Osqm on plan, depth upto 1.5mtr. including disposal of excavated earth upto 1 mtr from cutting edge, disposed earth is to be levelled and neatly dressed in: All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 20mm nominal size) Crushed
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level. 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) Crushed
Providing and laying Reinforced Cement Concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) in suspended floors, balconies, landings and staircase having upto 15° slope. excluding cost of centering and shuttering , all work upto floor V level
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand 4 graded stone aggregate 20mm nominal size. Crushed
Brick work with common burnt clay F.P.S.(non-modualar) bricks of class designation 75 in foundation and plinth in. Cement mortar 1 :6 ( 1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level upto floor V level. (By manual means)
Providing and fixing 1 mm thick M.S. steel door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6mm for diagonal braces
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
Centring and shuttermg including strutting, propping etc. and removal of form for· Foundations: footings, bases of columns etc. for mass concrete. (Complete Job)
Centring and shuttermg including strutting, propping etc. and removal of form for· Suspended floors, roofs, landings, balconies and access platform. (Complete Job)
Centring and shuttering including strutting, propping etc and removal of form work for. Lintels, beams, plinth beams, girders, bressumers and centilevers.
Centring and shuttering including strutting, propping etc and removal of form work for. Edges of slabs and breaks in floors and walls above 20 cm wide
Centring and shuttering including strutting, propping etc and removal of form work for. Weather shade chajjas corbels etc. Including edges.
Centring and shuttering including strutting, propping etc and removal of form work for. Arches, domes valuts upto 6m span
12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand)
Painting top of roofs with bitumen of approved quality at 17 kg per 10 sqm impregnated with a cost of coarse sand at 60 cudm per 10 sqm including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete. With residualtype petroleum bitumen of penetration 80/100
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa at 35kg per cum of earth and gobri leaping with bhusa at 35kg per cum of earth and gobri leaping with mix 1:1 ( 1 clay: 1 cow dung) and covered with flat tile bricks of class designation 1 00 grouted with cement mortar 1:3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finishing neat. With Hand moulded F.P.S brick tiles.
Providing gala 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design : In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diameter
Cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand . : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 50 mmthick with 20mm nominal size stone aggregate. Crushed.
Providing and fixing glass strips in joints of terrazo I cement concrete floor. 40 mm wide and 4 mm thick
Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggreagate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. Crushed.
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade
Finishing walls with water proofing cement paint of required shade New work (two or more coats) applied @3.84 kg/ 10 sqm
Applying priming coat: with ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work.
Painting with ready mixed synthetic enamel paint of approved brand and manufacture in all shades to give an even shade New steel work (two or more coats)
Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, ,watering, rolling each layer with half tonne roller or wooden oo steel rammers, and rolling every third and top -most layer with power roller of minimun 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions lead upto 50 mtr and lift upto 1. 5 mtr. in : All kinds of soil:
Centring and shuttermg including strutting, propping etc. and removal of form for: Extra for shuttering in circular work (20% o f respective centring and shuttering items)
Extra for plastering on circular work not exceeding 6m in radius: In one coat
Providing and fixing on wall face unplasticised- PVC moulded fittings/accessories for unplasticised- Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 1 0 mm gap for thermal expansion. 110 mm bend
Extra for providing and mixing water proof material in proportion recommended by the manufactures: 12mm cement plaster 1:4 (1 cement:4 sand)
Providing corrugated G. S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G. I limpet washers or with G. I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whereever required. 0.63 mm thick with zinc coating not less than 350gm/m2
Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.
Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : 150 mm dia. pipe
Filling available excavated earth (excluding rock) in traenches plinth, sides of foundation etc. Layers not exceeding 20 cm in depth. Consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutmen"ts, posts ans sturts, etc. upto floor five level excluding cost of centring, shuttering, fmishing and reinforcement. (1 cement : 1.5 coarse sand : 3 graded crushed stone aggregate 20mm nominal size)
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Single pole
Single pole and neutral 32 AMP
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
3 pin 5/6 amp socket outlet
15/16 amp switch
6 pin 15/16 amp socket out let.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/ Isolator) 2 + 4 way/ 6 way , Double door
Supplying and fixing Approved Brand Material:- Fan Box
Bulk Head with 9 watt Bulb
L.E.D. 20 watt tube light fitting 4 feet long complete
LED Bulbs with Holder 12 Watt.
Ceiling Fan 1200mm Sweep
Service Aluminium cable 10mm 2 core with suport wire.
RATTAN CHAND GOVT CONTRACTOR
Abdul Rehman
RANDEEP SINGH MANHAS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .