| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-Finance 215 UNIT NO 215 VARDHMAN GRAND PLAZA SECTOR 3 ROHINI NORTH WEST DELHI 110085 | NORTH WEST | DELHI | 110085 | L1 | Accepted-Finance ok | |
| 2 | L2₹11.9 L+₹2.3 L (23.6%)Accepted-Finance | L2 | Accepted-Finance ok |
Tender Value
₹10.3 L
EMD Value
₹20,500
Closing Date
29 May 2026, 3:00 pmClosed
Executive Engineer (E)
Executive Engineer (E) North West, Elect. Divn., PWD ISBT, Kashmere Gate, Delhi-110006
Additional / Alteration of Air Conditioning System installed at Nav Kiran Building at Nav Kiran, Halfway/Longstay Home, Sector-03, Rohini, Delhi.
2026_PWD_291772_1
10/EE(E)/NWED/PWD/2026-27
Open Tender
Electrical Works
Works
90 days
Rohini
Please refer Tender documents.
18 documents required · 18 mandatory
₹0
₹20,500
Yes
1 Jun 2026
21 May 2026
29 May 2026
21 May 2026
29 May 2026
21 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature)
a) Inverter Type, 1.5 TR with Inverter 5 Star BEE rating | 2 | Nos. | 40,074 | ₹80,148 |
| 2 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, stand, wireless Remote control and all other relevant accessories suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature).
a) Inverter Type - Cooling only, 1.5 TR with 5 Star BEE Rating | 3 | Nos. | 43,539 | ₹1,30,617 |
| 2.1 | b) 2.0 TR with 5 Star BEE Rating | 7 | Nos. | 57,396 | ₹4,01,772 |
| 3 | Supplying &Fixing of 4 KVA capacity automatic voltage stabilizer with time delay relay and high/low\ voltage trip facility input voltage 150V to 290V and output voltage 220+10% with copper flexible cable connection etc. as required at site. (For 1.5 Ton Ac) | 5 | Nos. | 2,088 | ₹10,440 |
| 4 | Supplying & Fixing of 5 KVA capacity automatic voltage stablizer with time delay relay and high/low voltage trip facility having voltage range 150 V to 280 V +10% with copper flexible cable connection i/c mounting of stabilizer unit with cutting of existing board frame & mounting arrangement etc. as required at site. (For 2 TR AC) | 7 | Nos. | 3,974 | ₹27,818 |
| 5 | Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 5/8"and 3/8" suitable for 1.5/2 TR STAC duly insulated by nitrile rubber, covered with MS pipe for safety of the pipe along with necessary support, clamps, brackets as required as per site requirement. | 150 | Meters | 682 | ₹1,02,300 |
| 6 | Supplying & Fixing of hard drawn copper suction and discharge refrigeration pipe of size 1/2"and 1/4" suitable for 1.5/2 TR STAC duly insulated by nitrile rubber, covererd with MS pipe for safety of the pipe along with necessary support,clamps,brackets as required as per site requirement. | 150 | Meters | 492 | ₹73,800 |
| 7 | Supplying of following accessories for the existing 1.5 TR/ 2 TR. capacity WTAC / STAC unit, using existing man power for replacement on day to day maintenance work:
a) 15 Amp 3 Pin plug Top (ISI Marked) | 15 | Nos. | 38 | ₹570 |
| 7.1 | b) 3 core PVC insulated PVC sheathed copper wire 2.5 Sq.mm copper flexible | 150 | Meters | 211 | ₹31,650 |
| 8 | Pdg. & Fixing of following heavy duty PVC drain pipe for draining of condensate to a safer disposal point in recess/ surface i/c cutting the chase in the wall and making good the same with cement work etc. complete as required. (a) 25 mm dia | 80 | Meters | 76 | ₹6,080 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.37 MB
BOQ_387253.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .