Tender Value
Refer Docs
EMD Value
₹21,000
Closing Date
4 Dec 2020, 3:00 pmClosed
Executive Engineer
Electrical Division PWD BnR Rohtak
Construction of building of Govt. College Jassia (Rohtak) (Pdg. Fire Alarm System only)
2020_HRY_151162_1
PWD/Electrical/171262
Open Tender
Electrical Works
Item-rate/Agreement basic
60 days
Rohtak
Please refer to tender documents
3 documents required · 3 mandatory
₹1,000
₹21,000
Yes
6 Aug 2021
20 Nov 2020
7 Dec 2020
20 Nov 2020
4 Dec 2020
20 Nov 2020
Amount
SITC of Micro Processor based two wire fault tolerent,networkable type fire alarm/detectoin control panel having numbers of two loops to suit minimum 20% extra over the numbers of fire detector. The panel shall be able to give location of all fire/fault condition of addressable units via the address codes. further the panel must be able to automatically switch ON/OFF respect to control module whenever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character LCD unit/5.7" TFT to indicate fire/ fault signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respect. The panel shall be sheet steel power coated, sheild to IP30. The panel shall have 20 zones with individual LED indicators, expendable to 80LED indicators. The panel shall have 3 Serial ports.The panel shall have a built inpower supply and battery charger along with maintainance free 24 AH 2x12 volts SMF lead acid battery capable of running for a minimum of 24 hour with battery charger complete as required and confirming to BS 5839 standards and duly approved by EN 54/UL/VDS as per specifications to complete job in all repect upto the entire satisfaction of Engineer -in- charge of work. Makes : Bosch FPA 1000 Series, Cerberus by Siemens, Edwards EST3, Honeywell Morley Zxe Series
SITC of Auto Dialer (Wired) to dial various numbers in the case of triggering of siren to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. 39/9/20201 Make: DSC/BENTEL FALCON
SITC OF Public Adress System in Rack: consisting of the following complete in all respect
240W Amplifier to suitable size (BOSCH/HONEYWELL/EDWARD/SIEMENS) - 01 No
Interface unit for integration of main fire alarm pnel with public address system = 01 No.
SITC of Public Adressable speakers wall / Surface Mounted 6 watts complete in all respect. Make: BOSCH/HONEYWELL/ATEIS
SITC of addressable multisensor detector with a combination of optical and thermal including mounting base, auto addressing feature as required. Detector should have 2 as per NFPA 72style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availabilitry of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG aggrement EFSG /F/97/005. Detector should monitor electro magnetic interference and report to the panel - current and average value. EMC safety for detector shall be 50V/m. Shall be EN54/ VDs/UL certification. ( Detectors without inbuil isolator may be considered with an additional isolator module after 20 devices to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. Makes: Bosch FAP-440-T-FAA-440, Siemens, Cerberus oh921+DB-11, Honeywell Morley MI-PTSE-B501, Edwards SIGA PHD + SIGA
SITC of addressable heat detector with fixed and rate of raise feature including mounting base with LED etc. complete as required.Each Detector should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005. Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/VDs/UL certification. (Detectors without inbuilt isolators may be considered with an addtitional isolator Module after 15 devices to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. Make: Bosch FAH-440+FAA-440, Siemens Cerberus HI921 + DB-11, Honeywell Morley MI-RHSE+B501, Edwards SIGA PHD + SIGA
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with Back Box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch FMC-210-DM-G-R/Morley IAS MI-MCPFLEXI/
SITC of Addressable Loop powered hooter with strobe complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch/ Siemens, Cerberus, Morley/Edwards.
SITC of addressable Control Relay Module with flixible network structur4es with a mamimum switching current of 1 A @ 30V DC shall be EN54/UL/VDS Certification with all labour and material required to complete the labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work. Makes: Bosch / Siemens Cerberus / Morley / Edwards/GST-I9301.
SITC of Intelligent Analog Addressable Monitor Modules for monitoring of a line with EOL resistor/Potential free contact voltage monitoring shall be EN54/UL/VDS approved .(In case of 2 monitoring feature in one module (points) each point shall be considered separetely for payment to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. Makes: BoschFLM-325-214, Siemens, Cerberus HTR1-M, Morley MI-DMMI, Edwards EST 3
SITC of Analog Addressable type Active Repeater fire alarm panel with Backlit LCD Display, having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54/UN54/VDS with all labour and material to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of the work. Make: Bosch FMR 1000 - RCMD, Cerberus by Siemens, Morley ZXRA, Edwards, 3- LCD ANN
Supply and Erection of FIRE EXTINGUISHERS duly hang on wall with necessary hook in all respect upto the entire satisfaction of Engineer-in-Charge . Make: Safex, Minimax, Ceasefire
i) ABC dry Powder extinguisher 6 Kg Cap
ii) Water CO2 9 Ltr. Cap
iii) CO2 4.5 Kg Cap
Supply and erection of PVC pipe (20mm dia) ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc.to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. (Based on HSR) Make: Diplast/AKG/Kalinga
Providing & Fixing PVC FRLS single core x 1.5 mm2 copper conductor flexible multistranded wire to complete the job in all respect up to the entire satisfaction of Engineer - in - Charge. (Based on HSR) Make: Finolex/Polycab/Havells
providing & fixing NOVEC 1230 tube trace based panel flooding system to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. Makes: ANSHUL/ Siemens/ROTAREX/FYREMAX/MINIMAX
SITC of minimum 1000 mtr. Range Kheraj / National make SIRON Generator Provided at the roof of the building with separate power SITC relay to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work
SITC of Glow Type EXIT Sign Board photo luminescent of size 30 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3 mm acylic sheet on both side showing marking (running man, Arrow and Exit ) and hanged with the ceiling with vchain and fastener to complete the job complete in all repect upto the entire satisfaction of Engineer -in- charge of work. Make: GLOLITE/PES/OMEX
SITC of 2KVA online UPS with external SMF batteries 12V of suitable AH battery for minimum 2 hour backup complete in all respect. Make: Microtek/Luminious/APC Libert
S/E of PA cable 2 core complete in all respect up to the entire satisfaction of Engineer-in-Charge. Make: Finolex/Polycab/Havells
Protection Engineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .