Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹26.3 L+₹3.5 L (15.2%)Rejected-Finance | L2 | Rejected-Finance Being not the lowest | |
| 3 | L3₹27.3 L+₹4.4 L (19.5%)Rejected-Finance B 33 171 PATEL NAGAR GURDASPUR ROAD PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being not the lowest | |
| 4 | L4₹27.7 L+₹4.9 L (21.5%)Rejected-Finance | L4 | Rejected-Finance Being not the lowest | |
| 5 | L5₹30.1 L+₹7.3 L (31.8%)Rejected-Finance | L5 | Rejected-Finance Being not the lowest |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
16 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / MAINT OF ELECTRICAL JUNCTION BOX DBs AND OTHER ELECTRICAL MISC WORKS AT MD / OTM ACCN AREA UNDER GE MINNIEBAY, PORT BLAIR
2021_MES_488732_1
8101/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹52,000
Yes
5 Feb 2022
17 Nov 2021
24 Dec 2021
17 Nov 2021
16 Dec 2021
3 Dec 2021
60 days
Amount
M& L for preparation to internal and external old steel surface of LT Feeder Pillar Box/ Panel Boards of various size and completely removal of existing treatment by scraping or chemical and surface painted with DUCO paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed
M& L for repair of LT Feeder Pillar Box/ Panel Boards made out of 2.00 mm thick mild steel sheet fixed to existing frame and painted with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing warn out shutter frame and fixed with minimum two hinges to existing frame complete all as specified and directed.
S&F in repairs aluminium tower bolts, 300mm long bright bolt including connected accessories fixed on front and rear side of the doors for locking LT FP Boxes complete all as specified and as directed
S&F in repairs doors hinges suitable for LT feeder pillar/Panel box complete including welding complete all as specified and as directed
Taking down of PCC any grade complete all as specified and as directed
M&L for cement concrete in foundations filling and mass concrete of B1grade with using 20 mm aggregate (1:2:4) complete all as directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded broken stone aggregate as in coping/collar of poles including necessary form work complete all as specified
S&F in replacement MCCB 400 Amps,TPN 4 pole, 415 volt, breaking capacity 35 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in replacement MCCB 250Amps,TPN 4 pole, 415 volt, breaking capacity 25 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in replacement MCCB 200Amps,TPN 4 pole, 415 volt, breaking capacity 25 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in replacement MCCB 160 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in replacement MCCB 100 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in replacement MCCB 63 Amps, TPN/4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S & F in replacement on load change over switch 4 pole 400 Amps in sheet metal enclosure complete all as specified and as directed
S&F in replacement of aluminium cable lugs for fixing of armoured cables in panels complete all as specified and as directed for the following sizes of cables :
S&F in replacement Copper cable lugs for fixing of armoured cables in panels complete all as specified and as directed for the following sizes of cables :-
S&F in replacement of Cable gland of LT UG cables in panels complete all as specified and as directed for the following sizes of LT UG cables :-
Supply, installation, testing and commissioning LT Feeder pillar box CPRI approved of Size 800x600X450mm suitable for 3 phase 415 Volts out door type made out 3.15mm thick CRCA sheet for outside and 2.00mm thick inner sider with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 400Amp and including PCC foundation as per site requirement to accommodated to the following. INCOMING (a) MCCB 4 pole 100 Amp 25 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING (a) Through Bus Bar 1. MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in replacement digital Ammeter 0-650 Amps rating including necessary fabrication required and painting the effected area with existing paint complete all as specified and as directed
S&F in replacement of digital Voltmeter 0-750 Volts rating including necessary fabrication required and painting the effected area with existing paint complete all as specified and as directed
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade including taking down old unsv cable complete all as specified and as directed for the following size :- Note: The rates should be inclusive in cable lugs, Cable Gland and joint kit
4 Core 6 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
Taking down and relaying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 25 Sq mm complete all as specified and as directed
S & laying in replacement of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
Taking down and relaying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
S&F in replacement of GI pipe of medium grade 40 mm dia including all fitting / fixture for fixing on wall and road crossing etc. complete all as specified and as directed
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqm on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed
Removing excavated surplus soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed
M&L for road cutting, removing of material , returning filling and PCC 1:2:4 using 20mm graded stone aggregate for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed
M&L for fault finding of LT UG cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed Note:- LT UG Cable, Straight through joint kit and DWC (Double Wall corrugated) HDPE pipe measured and paid separately
S & F in replacement cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 25 Sqmm 3.5 core complete all as specified and as directed
M&L for re-routing the serviceable power cable on wall /cable duct of size 10 to 25 Sqmm with shaddleing with aluminium pati with required size of screw inside cable duct complete all as directed.
M&L for re-routing the serviceable power cable on wall /cable duct of size 70 to 185 Sqmm with shaddleing with aluminium pati with required size of screw inside cable duct complete all as specified and as directed
S&F in replacement IP 66/67 thermoplastic polycarbonate cable junction box of size 205X255X92 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of size 25X3 mm ,one no of MCB SP 6 Amp and four way 32 Amp connector complete all as specified and as directed
S&F in replacement IP 66/ 67 thermoplastic polycarbonate cable junction box of size 130X180X77 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of size 25X3 mm ,one no of MCB SP 6 Amp and four way 32 Amp connector complete all as specified and as directed
M&L for earthing complete with copper earth plate electrode 60 cm x 60 cm x 3 mm thick, buried directly in ground earth pit not less than 2.25 metre below normal ground level with top edge of the plate not less than 1.5 mtr below ground level, connected to and including copper earth strip 25 x 3.00 mm by means of copper brazing and steel bolts, nuts, check nuts and washers protected with 40mm bore GI pipe light grade and 15 mm dia GI pipe for watering and earth pit surrounded by picked layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board and testing on completion including PCC (1:3:6) type C-2, using 20mm graded stone aggregate as in earthing pit with RCC cover and framing including necessary earth work etc, including taking down old earthing complete all as specified and as directed Note: (i) Cost of Copper earth Strip and GI protection pipe up to 7.5mtr length shall be deemed to be included in the rate quoted for this item (ii) The unit rate shall also includes for Wire mesh, funnel, excavation.returninng & filling. PCC chamber pit,RCC cover & test point (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required , as specified and as directed by Engineer in charge as per (v) Copper Material should be molecularly 99.99%
Taking down UG Cable Route indicator and S&F PCC Route indicator of size 600X150X 300 MM writing of " MES LT/HT Cable" in white ink over red coloured with danger notice fixing above UG Cable below ground 200mm including PCC and earth work complete all as specified and as directed
M&L in replacement of earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Square Bar embedded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 30X30X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black with white background complete all as specified and as directed
M&L in replacement of PCC earthing pit of outer size 450X450 X300 MM and RCC pit cover of required size including necessary earth work complete all as specified and as directed
M&L for painting to Steel tubular / RCC poles 9 m long with one coat of Synthetic enamel paint black/yellow combination with zebra marking up to 1 M from ground level / copping remaining Job portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc. Complete all as specified and as directed
Dismantling the existing old rusted /unserviceable Steel / RCC poles of any type including all fitting fixture complete all as specified and as directed
M&L for GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws, with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9M including necessary Earth work,PCC foundation copping etc and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed
S&F of 2.5 Sq.mm (nominal area) PVC unsheathed multi stranded copper conductor PVC insulated 1100 volt FR grade twin core cable drawn through CPVC Pipe not less than 20 mm dia for connecting the street light fittings complete all as specified and as directed
S&F GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.5 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed
S&F in replacement energy efficient street light luminaire LED type 90 watts,IP66 ,230volts, 50 Hz , in deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed
S&F in replacement energy efficient solar street light all in one with lithium battery LED type of 30 watts,IP-65 in built motion sensor colour temp 6500 complete all as specified and as directed
S&F in replacement energy efficient street light luminaire LED type 72 watts,IP-66 ,230 volts, 50 Hz , in deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts,and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed
S&F in replacement service wire Al Conductor Weather Proof 6 Sqmm 2 core complete all as specified and as directed
S&F in replacement service wire Al Conductor Weather Proof 10 Sqmm 2 core complete all as specified and as directed
S&F in repairs rubber insulation tape 25 cm width 2.5 Mtr long fixing of connection make water proof outside the Electrical equipment's and also fixing the underground cable where crack arises outside complete all as specified and as directed
S&F in replacement LED 35 watt Post top energy saving environmental friendly ,design with symmetrical light distribution, spun aluminium landscape luminaire made in cast aluminium spigot housing and IP 65 Protection all as directed
S&F in replacement LED 10 Watt Bollard light made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete all as specified and as directed
S&F in replacement LED 40 watt Post top energy saving environmental friendly ,design with symmetrical light distribution, clear landscape luminaire (CDL) made in cast aluminium spigot housing and IP 65 protection all as directed
M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.
M & L un replacement of danger notice board of PVC sheet , printed with letters, figures ( English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with GI. clamps, bolts and nuts of approved size complete all as specified and as directed
M&L for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete including taking down all as specified and as directed NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL (ii) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible.
S&F in replacement of GI earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32 mm x 6mm thick, Galvanised using porcelain clit/post insulators, complete all as specified and as directed
S&F in replacement of Aluminium earth continuity conductor or main earthing lead fixed to wall above 11 mtr or rooftop of 3 rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, aluminium using porcelain clit/post insulators, complete all as specified and as directed
M&L for sheet metal board complete with locking arrangement, fabricated out of 2.00 mm thick MS sheet of size 0.90x0.60X0.20 Mtr flushed in wall including mounting arrangements for energy meters and one MCB TPN DB /MCCB TPN DB 4 way, front opening, painting with two coats of synthetic enamel paint over a coat of red oxide primer on internal and external surfaces and making good damaged surface complete including taking down old unserviceable rusted sheet metal enclosure, from the building and all as specified and directed by Engineer-in-charge. Note:- 1. Dismantle all energy Meter (7/9 Nos) and MCCB TPN/MCB TPN DBs(1/2 Nos) and kept in safe courstoudy and refixing the same day after fixing the metal board. 2.Concealed the DBs on wall all including make in good and matching with existing surface
S&F in replacement of vertical type MCCB DB TPN 4 way IP-43 made of sheet steel phis practised, powder painted with bus bar, neutral link, earth bar and Din rail ,415 Volts with double door complete all as specified and as directed
S&F in replacement MCCB 125 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed Note : MCCB should be ICU = 100 % ICS 3. MCCB should be adjustable O/L0.8-1 and S/C - 5-10 ln
S&F in repairs MCB SP 32- 40 Amps including necessary connection and testing complete all as specified and as directed
S&F in repairs MCB SP 63 Amps including necessary connection and testing complete all as specified and as directed
Taking down of unserviceable MCB blank plate from mcb DBs and supply and fixing of MCB blank plate from MCB DBs complete all as specified and as directed.
Taking down old unserviceable aluminium sub main wiring any size complete with PVC conduit/ casing capping and removing materials from site and making good disturbed surfaces of walls, etc complete as specified and directed.
M&L for sub main wiring with 2 runs of 10 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 10 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed. (Note : (i) PVC casing capping/ Conduit and its accessories measured and paid separately (ii) Two runs of cables and one run of earth wire shall be measured as one unit length )
M&L for sub main wiring with 2 runs of 6 Sqmm single core, PVC insulated, unsheathed 1100 Volts grade, multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on, walls, ceiling etc. as required including 6 Sqmm PVC insulated, unsheathed, multistranded, copper conductor, single core cable as earth continuity wire complete as specified and directed. (Note : (i) PVC casing capping/ Conduit and its accessories measured and paid separately (ii) Two runs of cables and one run of earth wire shall be measured as one run length )
S&F in replacement of meter box for single phase KWH meter complete all as specified and as directed
Taking down and refixing for Aluminium earth continuity conductor or main earthing lead fixed to wall above 11 mtr or rooftop of 3 rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, aluminium using porcelain clit/post insulators, complete all as specified and as directed
S&F in replacement of LED 100 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed
S&F in replacement of LED 150 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 66 Protection complete all as specified and as directed
S&F in replacement of MCB 63 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KA complete all as specified and as directed
S&F in replacement of MCB 100 Amps, TPN 4 pole, 415 volt, breaking capacity 16 KA complete all as specified and as directed
S&F in repairs LED 8 watt under water light energy saving environmental friendly ,design with symmetrical light distribution and IP 66 Protection complete all as directed
S&F in repairs LED 6 watt under water light energy saving environmental friendly ,design with symmetrical light distribution and IP 66 Protection complete all as directed
Cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance n.exc 60 Mtr complete all as specified and directed
S&F in repairs LED 100 watt highbay light indoor type energy saving environmental friendly ,design with symmetrical light distribution, luminaire efficiency of 125 lumen/watt and IP 54 Protection complete all as specified and as directed
S&F in repairs Aluminium Bus Bar of existing Size in the existing panel board on site on required shape post insulators, complete all as specified and as directed
S&F in repairs LED Indicating lamp (R-Y-B) complete all as specified and as directed
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and as directed
M&L for welding of two MS/GI Sheet / Pipes on site including grinding the welded portion and made smooth surface complete all as specified and as directed
SHUSHANT ASSOCIATES
KAPOOR AUTOMOBILES
NAVJEEVAN ENTERPRISES
bansal construction
M/s Pooja Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .