| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.8 L+₹1.0 L (2.83%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹38.7 L+₹2.0 L (5.37%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹40.3 L+₹3.6 L (9.76%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹40.7 L+₹4.0 L (10.8%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹81,400
Closing Date
9 Jun 2021, 6:00 pmClosed
CWE Patiala
HQ CWE, Bldg No 26, New Lal Bagh, Patiala - 147001
SPECIAL REPAIRS TO BLDG PERIODICAL SERVICES REPAIRS TO ROAD AND MISC BR AND EM WORKS FOR KV DAPPAR UNDER GE PROJECT DAPPAR
2021_MES_434887_4
8321/PAT/T-74/E8
Open Tender
Civil Works
Lump-sum
180 days
Dappar
As per cover 1
7 documents required · 7 mandatory
₹500
Yes
GE Project Dappar
₹81,400
Yes
3 Jul 2021
13 May 2021
11 Jun 2021
13 May 2021
9 Jun 2021
27 May 2021
13 May 2021 - 20 May 2021
Amount
Schedule 'A'Section-I B/R Works
Total amount of Sch 'A' Sec I (B/R Works)
Schedule 'A'Section-II (INTERNAL ELECTRIFICATION WORKS)
Total amount of Sch 'A' Sec II (Internal Electrification Works)
Schedule 'A'Section-III (Road Path work)
Total amount of Sch 'A' Sec III (Road Path Works)
Schedule 'A'Section-IV (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion and primer complete all as specified and directed.
Applying 02 coats of interior emulsion paint (white shade) @ 10 sq.m/litre/2 coats to ceiling surfaces over & including a coat of interior primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using emulsion and primer complete all as specified and directed.
M&L for wall tiles 300 x 200x6-7 mm thick self adhesive peel and stick for anti collision, waterproofing moist proof and sound insulated. Easy cleaning and maintenance with wet moist cloth economical wall covering designer material complete all as specified and directed by Engineer in Charge. NOTE : The contractor will removethe plaster where directed by Engineer in Charge and make even and smooth before apply of wall tiles.
Supply and fix ceramic laboratary sink of size 600x450x200mm fitted with existing slab and connected to existing duct complete all as specified and directed by Engineer - in Charge
M&L for approved earth obtained from outside MOD land, from distance beyond 5KM but not exe 10 KM and depositing ,levelling,rolling and compacting all as specified. earth filling
M&L for APP based pollymeric membren minimum weiging 3.6Kg/SqM and minimum 3mm thick reinforced with polyster non wove fabric(wt not less than 150gms/SqM) laid on primed surface including priming surface of roof by appling bituminous primer not less than 0.40Ltr/SqM by the same membrance manufacturer of density 0.87 to0.89 Kg/Ltr at 250 degree Celcius temp and vescosity 70-16 cps laid by the authorised agent of the manufaturer duly approved in writing before executing the treatment complete and preparation of surfaces complete all as specified and directed by Engineer-in Charge
Supply and fix CP laboratary cock swan neck one way,fancy type chromium plated cast copper alloy screwed down, high pressure ,screwed one end for 15mm bore of iron pipe or for fixed union and fixed in position all as specified and directed by Engineer-in -Charge
M &L for 2.5mm thick road marking thermo plastic reflective paint to be carried out mecanically with hot application of material appling @5Kg/SQMand glass beads@250gm/SqM confirming to CI No.803.4 of MoRTH in strips of 100/150mmwidth on road surfaces complete all as specified and directed by Engineer-in-Charge
S&F factory made ,unreinforced precast cement tiles of size 250mmx250mmx22mm,machine pressed as on roof surface confirming to IS 1237-1980 laid over and including 15mm thick screed bed in CM1:4 incl mixed with WPCcompound ,set jointed and pointed with grey cement slurry complete all as specified
Dehydration/centrifuging of transformer oil of 11KV/0.433KV transformer by means centrifuging machine electrically operated at site of installation of transformer in running condition of transformer including testing of transformer oil before and after centrifuging from top and bottom of transformer to achieve the BDV value 45KV, replacement of worn out porcelain bushing for 11KV HT/LT side complete all as specified and directed by engineer in charge.
Supply and topping up of transformer oil of dielectric strength not less than 60 BDV complete all as specified and directed by engineer in charge.
Material and labour for replacement of worn out silica gel breather with fresh Blue coloured silica gel suitable for 125 KVA-200 KVA capacity of transformers complete all as specified and directed by engineer in charge.
S&F in replacement of Double door vertical three phase prewired distribution board 8 way made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 400 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and including MCCB 4 pole 250 Amp rating repturing capacity 25 KA with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quote rate.
S&F in replacement of MCB single pole of 6 to 32 Amp capacity, 'C' curve,10KA, 240 volt complete all as specified and directed.
Preparation of old surface of transformer for painting externally including fins/radiators removal of all rust/oil/grease and unwanted material and then two coats of synthetic enamel metallic paint by means of spray gun at site of installation of transformers.
S&F Transparent Body, Poly Carbonate, Meter Box with Hing Type Locking, Arrangement suitable for Three, Phase Multi Function Energy Meter complete all as specified and as directed by Engr-in-Charge
M/s DATAAR BUILDERS
Supreet Associates
KG BUILDERS
Swami Engineers
SS BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .