Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹48.7 L+₹34,561 (0.71%)Rejected-Finance NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹50.0 L+₹1.6 L (3.33%)Rejected-Finance 121004 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹50.4 L+₹2.1 L (4.27%)Rejected-Finance NO 12 25 26 KATHIRAVAN NAGAR MAHALINGAPURAM PO POLLACHI COIMBATORE 642 002 | COIMBATORE | TAMIL NADU | 642002 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹50.6 L+₹2.2 L (4.61%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
27 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT OF CONDUIT DUCT FOR ELECTRICAL COMMUNICATION MEDIA CABLES MEDIUM HIGH BAY HANGER FITTINGS DAY LIGHT HARVESTING AIRFIELD LIGHTING AND CERTAIN MISC EM WORKS AT AF STN SULUR
2020_MES_384346_1
8364/E8
Open Tender
Miscellaneous Works
Item Rate
240 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
9 Nov 2020
7 Oct 2020
28 Oct 2020
7 Oct 2020
27 Oct 2020
21 Oct 2020
7 Oct 2020 - 20 Oct 2020
60 days
Amount
SCHEDULE A BOQ
Taking down existing AF Net cable /Electrical cable /Communication cable from wall / ceiling / floor for relaying .
Rigid cover of width 65 mm for DLP trunk of size 150 x 50 mm two compartment type cat no 2x011110 of Legrand or equivalent of L&T or Siemens
Rigid cover of width 130 mm for DLP trunk of size 150 x 50 mm cat no 011112 of Legrand or equivalent of L&T or Siemens
DLP aluminium trunk of size 150 x 50 mm cat no 011102 of Legrand or equivalent of L&T or Siemens
Dividers separation partition for DLP trunk of size 150 x 50 mm Two compartment type cat no 011106 of Legrand or equivalent of L&T or Siemens
Earth link for DLP trunk of size 150 x 50 mm cat no 011188 of Legrand or equivalent of L&T or Siemens
End cap for DLP trunk of size 105 x 50 mm cat no 011158 of Legrand or equivalent of L&T or Siemens
Supports for arteor 2 modules for cover 65 mm width cat no 011202 of Legrand or equivalent of L&T or Siemens
Clip for DLP aluminium trunk of size 105 x 50 mm cat no 010682 of Legrand or equivalent of L&T or Siemens
Cover joint for DLP trunk of size 105 x 50 mm cat no 011163 of Legrand or equivalent of L&T or Siemens
Flat angles for DLP trunk of size 150 x 50 mm cat no 011245 of Legrand or equivalent of L&T or Siemens
External angles for DLP trunk of size 150 x 50 mm cat no 011234 of Legrand or equivalent of L&T or Siemens
Supports for arteor 4 modules for cover 65 mm width cat no 011204 of Legrand or equivalent of L&T or Siemens
Cover joint for DLP trunk of size 150 x 50 mm cat no 011164 of Legrand or equivalent of L&T or Siemens
End cap for DLP trunk of size 150 x 50 mm cat no 011160 of Legrand or equivalent of L&T or Siemens
Rigid cover of width 85 mm for DLP trunk of size 105 x 50 mm cat no 011111 of Legrand or equivalent of L&T or Siemens
Trunking base joint for DLP trunk of size 105 x 50 mm cat no 011166 of Legrand or equivalent of L&T or Siemens
Clip-on partition for DLP trunk of size 150 x 50 mm Two compartment type cat no 011106 of Legrand or equivalent of L&T or Siemens
Flat angles for DLP trunk of size 105 x 50 mm cat no 011243 of Legrand or equivalent of L&T or Siemens
Earth link for DLP trunk of size 105 x 50 mm cat no 011188 of Legrand or equivalent of L&T or Siemens
Excavation in trenches not exceeding 1.5m depth and not exceeding 1.5 mtr in wide in hard/dense soil and getting out.
Removing of excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side land as directed by the Engineer-in-Charge. The rate is deemed to be included.
Fly ash cable protection cover of size 23x11.5 x7.5cm including taking down existing bricks of any size.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed.
Note :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unite rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road , excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 25 sqmm to 35 sqmm Make : Reychems, Densons, M Seal
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). Make of Cable : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No. 39 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 43 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 43 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 43 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 or equivalent in Siemens/ Schnieder.
Rigid, non-metallic, PVC conduit pipe, ISI marked, 40 mm bore, including bends, saddles, accessories complete all as specified and as directed.
PVC casing capping/ trunking of size 50mm x 50mm complete all as specified and directed.
Supply, installation and commissioning of advanced day lighting system of 750 mm Light Pipe with Dome + Diffuser + Flashing Plate with the following accessories of 1.2 Mtrs Length . (a) Sunlight capture system-Sunlight collector cover:- Sun light collector dome should be transparent, clear dome allows light to be collected across the sky from all direction shape should moulded, single piece, dome shaped, clear, transparent polycarbonate material and thickness not less than 3mm thick clear polycarbonate sheet. UV coating thickness for RAW material sheet should 80 microns for high UV resistance, UV block upto 99% (UV A&B), impact strength 600-800 J/M (ASTM D256), flame retardancy limiting oxygen index LOI-25 (ISO 4589 ASTMD 2863), light transmission is 83% test standard, heat resistance temperature should 45º - 150º celsius (DIN 53460) (VICAT VST/B) and thermal conductivity should be 0.21/m°c(DIN 52612) (b) Light Management system:- light deflection panels should be transparent, clear, PMMA with light deflecting angles more than light incidence angles, light transmission should be not less than 90%, panles fastening mechanical polymer push buttons system.
(c) Light transfer system:-Extension pipes:- diameter 400 mm,shape should be cylindrical, aluminium material, total reflectivity for LPR 400 mm-98%, material thickness not less than 0.4mm, protection film PE foil not UV resistant. (d) External Cladding:- If the light pipe are exposed to atmosphere external cladding is provided by galvanised iron sheet (GI) cladding enclsoing the reflective pipes inside with holding wall clamps. The pipes should be crimped circumfernctially to slip one into another and along the vertical lenght for overlap jointing of not less than 25mm. Pipes to be joined with aluminum reviting and closed with aluminium tape of 50mm width and 5 microns thickness. (e) Light diffuser:- Shape should be moulded, single piece flat/Dome shape, polycarbonate clear bright prismatic bright or pigmented opal white (soft white), thickness not less than 2mm thick material, light transmission not less than 80% with diffuser ring injection moulded ABS plastic ring -white color , double glazed and second glazing diffuser double glazed with 1.0mm thick clear polycarbonate with 90% light transmission it should be locking button provision of pipe into the diffuser ring with silicon seal.
(f) Roof Kerb:- Factory made of two piece metal roof kerb entire roof kerb made of 0.5 mm bare galvalume sheet of 240 MPA, top cover should be galvalume sheet. It holds the lightpipe and light collector, bottom kerb also gavalum sheet. It fits on to roof with complete water proof arrangement, colour coated surface finished, kerb top side pointed arrow design with breaker arrangement, water proofing method is two seal system, primary seal, butyl rubber sealant and secondary seal-dow corning 789 high coefficient expansion silicon sealant, roof crest blocking caps should be factory made bare galvalume sheet metal cap. (g) Lumen Out put:- Lumen out put should be not less than 8000 lumen. light outputs test to be done with 1.0m x1.0m x1.0m light box as per standard test procedure in lab Make:-Sky shade Cat Part No.: SKYLP750R12 or equivelant as approved by GE. Note :- The contractor shall submit product warranty certificate from manufacturer for 5 years and installation warranty certificate for 5 years against any leakage and seepage.
LED aviation obstruction light with IP 66 protection water clear poly carbonate UV stabilized dome neoprene rubber with bind spike with 302 Nos LED bulbs including necessary electric connections including 2.5 sqmm, 2 core, PVC copper cables fixed on wall with 20mm dia PVC conduit from DB to light fitting fixed in and including GI pipe 25mm dia 1 mtr long grouted with PCC complete/ binding with existing angle frame etc complete all as directed at site. Make : Bajaj Cat No - 110731 or equivalent in Wipro/ CG.
60W LED inverter Flood light with inbuilt real time clock (RTC) for auto ON/ OFF feature, emergency light output, shall have maximum 1.5 – 2 hours battery back up with Li-ion battery at inverter load in case of power failure, system lumen not less than 100 lumen, initial lumen at battery mode will reduce to 15-20%. Housing made up of pressure dicast aluminium body with Top maintainable and front cover clear toughened glass, with IP 66 and IK05 protection, open and short circuit protection, reverse polarity protection, high voltage cut off at 300V + 10V and 5 KV internal surge protection, PF > 0.95, THD < 10% and Driver Efficiency > or = 85%. CRI > or = 70. Make :- Halonix Model No - HLFLD-ML30-60-CWL-INV-RTC-DIMM or equivalent of Philips/ Bajaj.
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
IP 66 Pole Mounted street lighting Junction Box 160x240x120 mm made of Polycarbonate, supplied with 1 No. 6A 10KA SP MCB, 1 No. 63A 4P FR Polyamide color coded RYBN Terminals Block, 1 No. each of Earth & Neutral Terminal mounted on 35mm DIN channel and fitted inside Enclosure alongwith Pole Mounting bracket, pole clamp & hardware made of Stainless Steel 304. The Junction Box enclosure Cover should have inbuilt 2 nos Polycarbonate Hinges with SS 304 Hinge pin, for Cover not to detach from Base on opening and should be properly tightened to base with Polycarbonate screws having sealing gaskets of extruded silicon rubber. The Polycarbonate enclosure should have properties Flame Retardant UL94V0, UV, Glow Wire test 960 Deg C, Impact IK08, Halogen free & RoHS compliant, Glow Wire Test for 960⁰ C. Type test reports from NABL lab in India along with Polycarbonate manufacturer batch test certificate should be submitted. Make of junction box shall be as per make mentioned in list of makes in PS.
Supply and fixing 45 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-45-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 50 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
External angles for DLP trunk of size 105 x 50 mm cat no 011232 of Legrand or equivalent of L&T or Siemens
Supports for arteor 2 modules for cover 85 mm width cat no 011212 of Legrand or equivalent of L&T or Siemens
Dividers separation partition for DLP trunk of size 150 x 50 mm cat no 011108 of Legrand or equivalent of L&T or Siemens
Supports for arteor 3 modules for cover 65 mm width cat no 011203 of Legrand or equivalent of L&T or Siemens
Clip for DLP aluminium trunk of size 150 x 50 mm cat no 010682 of Legrand or equivalent of L&T or Siemens
Dividers separation partition for DLP trunk of size 105 x 50 mm cat no 011108 of Legrand or equivalent of L&T or Siemens
Trunking base joint for DLP trunk of size 150 x 50 mm cat no 011166 of Legrand or equivalent of L&T or Siemens
Flat junction for DLP trunk of size 150 x 50 mm cat no 011251 of Legrand or equivalent of L&T or Siemens
4 feet surface mounted batten type 20W LED luminaire with emergency light output, shall be maximum 4 hours battery backup in case of power failure with Li battery, luminaire efficacy 100 lm/w with an operating voltage range from 140V - 270V, initial lumen at battery mode will reduce to 35 - 50%, charging time appox 8 - 12 hours. The luminaire shall have aluminium extruded main housing, PC LED front cover. The luminaire shall have a CCT of 6500K, CRI >80, Power factor >0.95, THD <30%, driver efficiency > 85%, electronic control gear, CC driver and 50,000 burning hours as per L70 B50 criteria. The luminaire shall be EMI/ EMC complaint and shall have open and short circuit protection, reverse polarity protection, internal surge protection of 3.0 KV, IP 20 ingress protection. Make :- Halonix Model No : HLB-08-20-CW-INV or equivalent of Philips/ Bajaj
Note :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid, Seoul semiconductor. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Rigid, non-metallic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed.
XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 70 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 50 sqmm to 70 sqmm Make : Reychems, Densons, M Seal
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Wire : Plaza/ Polycab/ Havells Make of Casing Capping : Polycab/Modi/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 74 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 74 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 74 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Avon Plast/ Supreme/ Diplast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No 79 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 79 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 79 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Shuttered socket outlet 3 pin 5 amps, flush type
Shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Supply only modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix bell push, flush type
Supply and Fix bell push, modular type, 1 way
Supply and Fix ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked.
Supply and Fixing lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
LED batten luminaire surface mounted 4 feet system wattage of 38 Watts and not less than 4100lm with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature> 5700K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, SDCM<5, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level ≥ 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. (Make-Philips of Catalogue No. BN108C LED 40S PSU CDL WH or eqvt of Bajaj/ Wipro
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation. Make : Model HTSP 317 of safeTrode or equivalent in OBO Betterman/ FURSE/ERICO.
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 04 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor before commencement of work.
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH valve should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm should be fixed on proper post insulator at the instrument end ( The rate of earthing strip up to 7.5 Mtrs is included in the quoted rate).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concern.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintened duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall given a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is mainained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing per each earthing shall be retained from payment due to the contractor for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) The contractor shall submit CPRI India certified document for copper bonded rod to ensure genuity of material.
(xviii) Sign board of mild steel 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing should be fixed near the earth pit after completion as directed by engr -in- charge.
(xix) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 9.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm dia for each electrode pit complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE/ Electrogrip Model/ EGTEK3LC of ISG Global or equivalent in OBO Betterman/ ERICO. Note :- The contractor shall submit load bearing capacity certificate from the manufacturer.
Supply and fixing of LED midbay symmetric beam luminaire with housing made of die-cast aluminium of system wattage not more than 70W. The luminaire shall be with dedicated optics to provide precise light distribution of 120 degree beam angle. The luminaire shall be designed to meet its specifications on performance & lifetime at a design ambient temperature of -10°C to 45°C (Ta 45°C). A specially designed heat management system to ensure luminous efficacy >=105 lm/ W for the system and ensure lumen depreciation upto 30% over 50k burning hours. The luminaire is designed to meet IP66/ IK08 classification and is complaint with relevant immunity, safety and performance and EMI standards. The system lumens shall not be less than 7500 lumens with 6500K CCT. The CRI shall be > 70. THe luminaire shall be able operate from 140-270V AC, 50 Hz with > 0.95 PF & THD <=10%. The LEDs shall be SMD type (not COB type) and each LED shall with peanut optics. The driver shall be of potted type. Make :- Philips BY150P LED76S CW PSU HE SY120 FG GR or equivalent in Bajaj or Wipro. The luminaire and driver shall be BIS approved and shall carry "R" number.
Supply and fixing 30 watt LED Inverter RTC Street Light with inbuilt RTC (Real Time Clock) for AUTO ON/ AUTO OFF and must have DIMMING facility from 10 to 100% of Rated wattage as per user defined timeline. Housing made of Pressure Die Cast Aluminium, TOP MAINTAINABLE and with clear heat resistant toughened glass, should have secondary lens for better optics, should have Constant current RTC enabled electronic driver with 5 KV SPD, IP66. Street light shall have inbuilt Li-ion battery of 5200 mAH and shall have >1.5 hrs battery backup at inverter load in case of power failure, Efficacy > 100 LPW, CRI > 70, THD <10%, PF >0.95, Cut off Voltage at 300 Volt + 10% and suitable for 50mm mounting pipe. Make :- Halonix Model No : HLSLD-ML04-30-CWL-INV-RTC-DIMM or equivalent in Philips/ Bajaj
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
PVC casing capping/ trunking of size 100 x 50mm complete all as specified and directed.
PVC casing capping/ trunking of 75mm x 50mm complete all as specified and directed.
LED Highbay Light, 200 Watts with housing –IP65 and IK07, circular high pressure die cast aluminum housing and manufacture logo embossed on the housing and High transmittance tempered glass cover, Optics-Lens with lens plate having NB & WB Optics, system efficacy->115 lumens/watt, Xitanium driver – IP66 complying to IEC- 61347 – 2- 13 Certification like CE, ENEC, ROHS, with rated life of 50000Hrs for driver at TC-80 deg C along with all safety features –Thermal protection, voltage range is 90 - 295 Volt,surge protection 4 KV, protection against input over voltage<320 VAC for 48 Hrs, Driver failure rate<0.2% per 1 Khr @ TC 70-80 Deg C, driver efficiency -93% at Max Load, internal wiring –Teflon, SDCM<5, CCT-5700, CRI>80, THD<20 at Max load , Third harmonics <20%, PF>.95 fixed complete all as directed at site.(Make: Philips cat No:415P LED145S CW NB FG PSU GR S2 or eqvt LT/ Schreder
Notes:- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
Supply, installation and commissioning of advanced day lighting system of 530 mm Light Pipe with Dome + Diffuser + Flashing Plate with the following accessories of 2.4 Mtrs Length . (a) Sunlight capture system-Sunlight collector cover:- Sun light collector dome should be transparent, clear dome allows light to be collected across the sky from all direction shape should moulded, single piece, dome shaped clear, transparent polycarbonate material and thickness not less than 3mm thick clear polycarbonate sheet. UV coating thickness for RAW material sheet should 80 microns for high UV resistance, UV block upto 99% (UV A&B), impact strength 600-800 J/M (ASTM D256), flame retardancy limiting oxygen index LOI-25 (ISO 4589 ASTMD 2863), light transmission is 83% test standard, heat resistance temperature should 45º - 150º celsius (DIN 53460) (VICAT VST/B) and thermal conductivity should be 0.21/m°c(DIN 52612) (b) Light Management system:- light deflection panels should be transparent, clear, PMMA with light deflecting angles more than light incidence angles, light transmission should be not less than 90%, panles fastening mechanical polymer push buttons system.
(c) Light transfer system:-Extension pipes:- diameter 400 mm,shape should be cylindrical, aluminium material, total reflectivity for LPR 400 mm-98%, material thickness not less than 0.4mm, protection film PE foil not UV resistant. (d) External Cladding:- If the light pipe are exposed to atmosphere external cladding is provided by galvanised iron sheet (GI) cladding enclsoing the reflective pipes inside with holding wall clamps. The pipes should be crimped circumfernctially to slip one into another and along the vertical lenght for overlap jointing of not less than 25mm. Pipes to be joined with aluminum reviting and closed with aluminium tape of 50mm width and 5 microns thickness. (e) Light diffuser:- Shape should be moulded, single piece flat/Dome shape, polycarbonate clear bright prismatic bright or pigmented opal white (soft white), thickness not less than 2mm thick material, light transmission not less than 80% with diffuser ring injection moulded ABS plastic ring -white color , double glazed and second glazing diffuser double glazed with 1.0mm thick clear polycarbonate with 90% light transmission it should be locking button provision of pipe into the diffuser ring with silicon seal.
(f) Roof Kerb:- Factory made of two piece metal roof kerb entire roof kerb made of 0.5 mm bare galvalume sheet of 240 MPA, top cover should be galvalume sheet. It holds the lightpipe and light collector, bottom kerb also gavalum sheet. It fits on to roof with complete water proof arrangement, colour coated surface finished, kerb top side pointed arrow design with breaker arrangement, water proofing method is two seal system, primary seal, butyl rubber sealant and secondary seal-dow corning 789 high coefficient expansion silicon sealant, roof crest blocking caps should be factory made bare galvalume sheet metal cap. (g) Lumen Out put:- Lumen out put should be not less than 8000 lumen. light outputs test to be done with 1.0m x1.0m x1.0m light box as per standard test procedure in lab Make:-Sky shade Cat Part No.: SKYLP750R12 or equivelant as approved by GE. Note :- The contractor shall submit product warranty certificate from manufacturer for 5 years and installation warranty certificate for 5 years against any leakage and seepage.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Modi/ Presto Plast/ Polycab Make of Wire : Plaza/ Polycab/ Havells Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely).
One light point/fan/bell point controlled by one switch
All as per item No. 129 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 129 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 129 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted; Test Certificate to be submitted; Certification : LM 79 for luminaire & LM 80 for LED source. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Note :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) The rate of earthing strip upto 7.5 mtrs shall be included in the quoted rate and beyond 7.5 mtrs shall be measured and paid separately.
(c) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned.
(d) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(e) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Galvanised Earth Strip of size 25x6mm as earthing lead fixed to wall/roofs etc all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
PVC casing capping/ trunking of 100mm x 75mm complete all as specified and directed.
PVC casing capping/ trunking of 100mm x 100mm complete all as specified and directed.
Clip for DLP aluminium trunk of size 150 x 50 mm two compartment type cat no 010682 of Legrand or equivalent of L&T or Siemens
Cover joint for DLP trunk of size 150 x 50 mm Two compartment type cat no 011162 of Legrand or equivalent of L&T or Siemens
Supports for arteor 4 modules for cover 85 mm width cat no 011214 of Legrand or equivalent of L&T or Siemens
Flat junction for DLP trunk of size 105 x 50 mm cat no 011251 of Legrand or equivalent of L&T or Siemens
Supports for arteor 3 modules for cover 85 mm width cat no 011213 of Legrand or equivalent of L&T or Siemens
LAKSHMI ELECTRICAL ENTERPRISES
Neptune Engineers and Builders
Rajapriyaconstruction
SENTOOR BUILDERSS
NAVEEN ENTERPRISES
T C KARUNANITHI
SUPER COOL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .