Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Aug 2026, 6:00 pmClosed
GE I R AND D GIRINAGAR PUNE
GE I R AND D GIRINAGAR PUNE
REPAIRS TO ROOF TREATMENT AND RECTIFICATION OF SEEPAGE LEAKAGE AND CERTAIN ALLIED WORKS IN CERTAIN BUILDINGS AT R AND DE E DIGHI PUNE 15
2026_MES_777962_1
GE I R AND D GNR TOKEN 18 OF 2026-27(8001)
Open Tender
Civil Works
Item Rate
180 days
GE I R AND D GIRINAGAR PUNE
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE I R AND D GIRINAGAR PUNE
₹50,000
16 Jul 2026
11 Jul 2026
3 Aug 2026
11 Jul 2026
1 Aug 2026
25 Jul 2026
11 Jul 2026 - 18 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling G.S. Sheet plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof covering any type pattern in roofing including ridges, hips, valleys and gutters etc.,if required dismantling iron work included and stacking the material within 50 metres lead
Note : Work will be executed at a height of upto 5m. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 106 | SQM | - | - |
| 2 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Note : Work will be executed at a height of upto 5m. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 100 | SQM | - | - |
| 3 | Providing and fixing precoated galvanised steel sheet in Ridges plain (500 - 600mm) roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete all as specified by E-in-C
Note : Work will be executed at a height of upto 5m. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor. | 10 | RM | - | - |
| 4 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. | 151 | KG | - | - |
| 5 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture | 50 | SQM | - | - |
| 6 | Removing old APP membrane of any thickness and description carefully without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed. | 720 | SQM | - | - |
| 7 | Demolishing cement concrete manually/ by mechanical means as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) without damaging the mother slab from roof and disposing off out side MD Land complete all as specified and directed. | 41 | CUM | - | - |
| 8 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 5 | CUM | - | - |
| 9 | Supplying and applying waterproofing treatment to sound, moisture free concrete surface. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised or equivelent expandive grout admixture supplied in 225 gm pouch, treatment of construction joints using polymer modified mortar prepared by using Nitobond SBR Latex or equivalent , application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP2 - Non-shrink cementitious grout or equivalent. any undulated surface and pot holes shall be filled with Epoxy mortar to obtain sound/levelled surface. Application of epoxy primer Nitoproof WB Primer or equivalent on sound mother slab surface. Followed by application of two coats of Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating supplied in 25 kg drum coverage of min @ 2.3 kg/m2 to achieve 1.5 mm dry film thickness in two coats placing glass fibric reinforcemnt min 225 gsm between 1st coat and second coats complete including all tools and tackles as per manufacturer’s specifications. Coating shall be having crack bridging of 2 mm, Elongation (ASTMD 412) > Min 500 %, Tensile Strength (ASTM D412) – 2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, Min 80% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 50, Water vapour transmission not more than 1g/m2/hr, Water Permeability (DIN 1048) – Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C HSE Guidelines: It is recommended to provide adequate general and local exhaust ventilation, provide protection to eye, face, hand and other skin by wearing appropriate gloves, goggles, face shields, respiratory protection etc. as directed in SDS of the product. : Note : work should be executed only through authorised company applicator and company as well as contractor should give written gurantee for 5 years for roof treatment to the department and if any leakage or seepage during gurantee period. contractor as well as company are responsible for the same and rectified without no extra cost. | 720 | SQM | - | - |
| 10 | Supplying and laying seperation & protection layer- Geotextile membrane 200 gsm prior to protection screed | 720 | SQM | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.18 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.70 MB
BOQ_871330.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .