Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.4 LAccepted-AOC 2 65 GORWA UDAYPARK SOCIETY REFINERY ROAD VILLAGE TOWN VADODARA CITY VADODARA VADODARA GUJARAT 390016 INDIA | VADODARA | GUJARAT | 390016 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹69.8 L+₹1.4 L (2.07%)Rejected-Finance 1ST 2ND FLOOR PLOT NO 13 C 13 3 RAMA ROAD SIDE INDUSTRIAL AREA NAJAFGARH ROAD DELHI 110015 INDIA | WEST | DELHI | 110015 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | Techno Electricals L1 | vardhman Airport solutions pvt. Ltd. L2 |
|---|---|---|---|---|---|
| 1.00 | Supply of 1 core 16 sq mm size 5 KV grade XLPE insulated & Poly Ethylene outer Sheathed Anti Termite & Anti Rodent treated Unarmoured unshielded Underground Cable for airfield lighting Primary Circuit, confirming to technical specifications . | 9,000 | Meter | 212 ₹19,08,000 Lowest | 213 ₹19,17,000 |
| 2.00 | Supply of 1 core 6 sq mm size 5 KV grade XLPE insulated & Poly Ethylene outer Sheathed Anti Termite & Anti Rodent treated Unarmoured unshielded Underground Cable for airfield lighting Primary Circuit, confirming technical specifications . | 1,000 | Meter | 100 ₹1,00,000 | 92 ₹92,000 Lowest |
| 3.00 | Supply of following sizes 5 KV grade dry type plug and receptacle primary connector kit with field attachment and suitable for 5 KV grade single core copper conductor, XLPE insulated PE outer sheathed unshielded cable,. complete as required and confirming to the technical specification.
a) 16 sq. mm. | 150 | Each | 450 ₹67,500 | 404 ₹60,600 Lowest |
| 4.00 | Supply of following sizes 5 KV grade dry type plug and receptacle primary connector kit with field attachment and suitable for 5 KV grade single core copper conductor, XLPE insulated PE outer sheathed unshielded cable,. complete as required and confirming to the technical specification.
(a) 6 sq mm | 20 | Each | 450 ₹9,000 | 404 ₹8,080 Lowest |
| 5.00 | Supply of 2 x 2.5 Sq. mm Two Pin Secondary Plug Assembly (20 Mtr long) Suitable for existing system. | 30 | Each | 750 ₹22,500 Lowest | 3,259 ₹97,770 |
| 6.00 | Supply of following size Anti Rodent Fire Retardant Permanantly lubricated HDPE (High density polyethylene) pipe alongwith necessary accessories l and with pulling rope fitted inside complete as required and as per the technical specifications etc. complete as required.
OD 63 mm | 7,500 | Meter | 115 ₹8,62,500 Lowest | 168 ₹12,60,000 |
| 7.00Supply of following rating 5000V, 50 Hz series Isolating Transformers encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections conforming to specification as required. | |||||
| 7.01 | 200 Watt, 20A/6.6Amps | 40 | Each | 4,775 ₹1,91,000 | 4,441 ₹1,77,640 Lowest |
| 7.02 | 45 Watts 20/6/6 Amps | 30 | Each | 4,150 ₹1,24,500 | 3,172 ₹95,160 Lowest |
| 7.03 | 300 watts 6.6/6.6 Amps | 15 | Each | 6,600 ₹99,000 | 4,903 ₹73,545 Lowest |
Tender Value
₹71.5 L
EMD Value
₹1.4 L
Closing Date
24 Sept 2024, 6:00 pmClosed
SM (E-E)
AAI, Lilabari Airport
Upgradation of old Airfield Lighting circuits of Runway (Ckt-B) at Lilabari Airport (Phase-II)
2024_AAI_206641_1
AAI/LBE/EE/CKT-B/CW-01/24-25
Open Tender
Electrical Works
Works
150 days
AAI, Lilabari Airport
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
₹1.4 L
22 Sept 2025
2 Sept 2024
26 Sept 2024
3 Sept 2024
24 Sept 2024
3 Sept 2024
3 Sept 2024 - 10 Sept 2024
Amount
Supply of 1 core 16 sq mm size 5 KV grade XLPE insulated & Poly Ethylene outer Sheathed Anti Termite & Anti Rodent treated Unarmoured unshielded Underground Cable for airfield lighting Primary Circuit, confirming to technical specifications .
Supply of 1 core 6 sq mm size 5 KV grade XLPE insulated & Poly Ethylene outer Sheathed Anti Termite & Anti Rodent treated Unarmoured unshielded Underground Cable for airfield lighting Primary Circuit, confirming technical specifications .
Supply of following sizes 5 KV grade dry type plug and receptacle primary connector kit with field attachment and suitable for 5 KV grade single core copper conductor, XLPE insulated PE outer sheathed unshielded cable,. complete as required and confirming to the technical specification. a) 16 sq. mm.
Supply of following sizes 5 KV grade dry type plug and receptacle primary connector kit with field attachment and suitable for 5 KV grade single core copper conductor, XLPE insulated PE outer sheathed unshielded cable,. complete as required and confirming to the technical specification. (a) 6 sq mm
Supply of 2 x 2.5 Sq. mm Two Pin Secondary Plug Assembly (20 Mtr long) Suitable for existing system.
Supply of following size Anti Rodent Fire Retardant Permanantly lubricated HDPE (High density polyethylene) pipe alongwith necessary accessories l and with pulling rope fitted inside complete as required and as per the technical specifications etc. complete as required. OD 63 mm
Supply of following rating 5000V, 50 Hz series Isolating Transformers encapsulated in polyester resin, finally moulded in neoprene type rubber and with primary and secondary connections conforming to specification as required.
200 Watt, 20A/6.6Amps
45 Watts 20/6/6 Amps
300 watts 6.6/6.6 Amps
Supply, Installation, Testing and Commissioning of indoor type cooled Constant Current Regulator of thyristor control Microprocessor type suitable for use in 240/415 VAC; 50/S0Hz input system with below mentioned output power with 5 step variation of current output suitable for local and remote operation with 24/48 VDC control supply complete with digital meters for output current, over current, over voltage and having earth fault protection including (i) end termination of incoming, outgoing & control cables, (ii) P/F of suitable size multi core control cable from CCR to junction box (up to 10 meters) (iii) P/F earthing strip of suitable size from nearest earth bus (up to 5 meters) etc. as required confirming to the specified particular specification as required.
7.5 KW CCR at 6.6 Amp, supply voltage 230 V
4KW CCR at 6.6 Amp, supply voltage 230 V
Supply of Spare Card suitable for 4 KW to 30 KW CCR having 6.6 A/6.6 A or 20/6.6A current rating having the following cards. (a) Microprocessor Main Control Card, (b) Power Supply + Driver Card, (c) IM Card (PCB)
Supply of 200W, 6.6A, 5KV, 50Hz Halogen Type lamp ( existing Osram make lamp cat no. 64386 ) suitable for existing AMA make HIRL Runway Fitting.
Supply of 200W, 6.6A Bi-Pin Halogen Lamp Holder suitable for existing AMA make Runway/Papi/Taxi Light Fitting
Supply of Lamp 105W, 6.6Amp ,5KV, 50Hz Halogen type lamp suitable for existing thorn make CAT no. INL-RNS+2x105W R+SC Inset type fitting (existing Osram make lamp Cat No. 64339 B 105-10 )
Supply of 360° Green Filter suitable for existing AMA make HIRL Runway Fitting.
Supply of 360° Red Filter suitable for existing AMA make HIRL Runway Fitting.
Supply of Obstruction light with all its accessories etc. complete as required.
Supply of C.I. housing box water tight round type metal container of outside diameter 330 mm and 200 mm height made of 10 mm thick all around except on top surface which is 15mm. thick to receive a light fitting base plate on the top and U.G. housing associated with power cable and having a clear holes at the side surface center 75 mm above bottom surface suitable to receive 1 No. 50 mm dia. and 1 No. 15 mm. dia G.I. pipe and checknut and having earthbolt of M-10 x 40 mm SS welded inside near the hole (100 mm away from the hole center) and having drain hole at the bottom suitably taped to receive 15 mm G.I. pipe and having clear opening of 220 mm dia. at the top and 6 Nos. M-10 taped holes at hole center of 260 mm to receive fittings base plate and bolts including supply of 1 no. neoprene gaskets, 6 nos. M10, 30 mm long stainless steel bolts with washers etc. complete as required as per specifications.
Making/cutting holes in each of the existing C.I. housing box of thickness upto 10 mm ) as per site requirement and instruction of EIC. (Location - shoulder area of runway made of Bitumin for entry/ exit of HDPE pipe of 63 mm Outer Dia) etc. as required.
Laying of following dia high density polyethylene (HDPE ) pipe, complete with accessories. in the soil for GLF work upto 750 mm deep connecting both/one end to existing chamber/CC collar, including excavation ,using protective covering and back filling & making good the same as per site requirement . OD 63 mm
Laying of high density polyethylene HDPE pipe of OD 63 mm complete with accessories. in the shoulder/runway/taxiway of Concrete/bitumin surface i/c machine cutting of runway/taxiway/shoulder surface of width upto 110 mm and upto 200 mm deep, and taking the excavated material out of the area within a lead upto 2 kms and refilling & making good the same by Cement Concrete ( 1:3:6 ) as per the site requirement.
Laying of HDPE Pipe of upto 63 mm OD complete with accessories in the existing cable duct / masonary trench etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess or along with cable for loop earthing etc. as required.
Making connection of 5 KV grade single core copper conductor, XLPE insulated PE outer sheathed unshielded cable with dry type plug & receptacle of i/c crimping & fixing, applying HT tape , etc as well as checking continuty with the existing ckts etc. complete as required as per EIC
Laying of one number PVC insulated & PVC sheathed armoured / unarmoured aluminium / copper conductor AFL / power cable of voltage grade upto 5 KV of size not exceeding 25 sq. mm. in the existing cable duct / masonary trench / RCC / HUME / METAL / GI / HDPE/DWC pipes etc. as required.
Identifying and Dismantling of old cable laid in existing masonary trench/ Duct of size up to 25 Sq mm, upto 5 KV grade and returning to AAI store
Providing and laying in position cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as required.
Supply, Installation, Testing & Commissioning of Three Phase Surge Protection Device (SPD) having 100KA 10/350 micro seconds neutral to earth, 50 KA 10/350 micro sec line to neutral, with limiting voltage less than 1.5 KV. To be installed in parrellel at the input of the UPS System & shall be of modular type including copper wire 16 sq. mm 12 mtrs for connecting surge protection device in parallel to the busbar of the main electrical panel, 63 Amp 3 phase MCB 4 pole with enclosure alongwith all accessories as required for installing SPD. Make: Magnus, Model: DSS BT P BCM 50 RM/3+N or equivalent as per standard practice and appoved by Engg-in- Charge.
Supply, installation,testing and commissioning of Digital Grounding Device 240 kA 3 phase 4 wire Portable type with built in Low Impedance equipment Grounding & bonding system. Provides 100% protection against Lightning Surges, static charge, Noises, ESD, EPR and eliminates abnormal electrical disturbances which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V having a digital 6 digit lightening surge counter, self-health visual status indicator with facilty to monitor ONLINE input voltages & Earth to Neutral Voltages Pre- wired pulverulent body painted metal enclosure to be connected in parallel to the power supply circuit, tested & Certified from CPRI, MIL STD810G, IEC61000- 6-1, IEC 61000-6-3,IEC 61643-11-2011 & confirming to ISO 9000 & ISO 14001-2015 & CE. Make in India, MakeMagnus, Model: DSS-MII-3P4-240 to be installed at the output of the UPS system
Supply of Elevated type unidirectional Approach light fitting suitable for use with 200W, 6.6 A halogen lamp complete with breakable coupling, gaskets, base plate with 6 nos. M 10 stainless steel bolts, 2 pin secondary lead and other accessories etc. conforming to relevant ICAO specifications and DGCA CAR requirements etc. complete as required
Supply of 3 x 105 W Inset type Uni -directional High Intensity Approach fitting, complete with prism assembly, optical assembly, 'O' ring seal, pressure relief test plug, 6.6 A halogen lamps, filters (Clear), shallow base, die cast aluminium inner body & outer cover and other accessories etc. meeting ICAO specifications and DGCA CAR standards complete as required
Supply of Inset type Bi -directional High Intensity Runway fitting (White/Yellow or White/White), complete with prism assembly, optical assembly, 'O' ring seal, pressure relief test plug, 6.6 A halogen lamps, filters (Clear), shallow base, die cast aluminium inner body & outer cover and other accessories etc. meeting ICAO specifications and DGCA CAR standards complete as required
Supply of Inset type Uni directional high intensity THRESHOLD (THD) (Green), complete with prism assembly, optical assembly, 'O' ring seal, pressure relief test plug, 6.6 A halogen lamps, filters (Clear), shallow base, die cast aluminium inner body & outer cover and other accessories etc. meeting ICAO specifications and DGCA CAR standards complete as required
vardhman Airport solutions pvt. Ltd. (BID ID -748349)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .