| 1 | L1₹2.1 CrAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹2.1 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.5 Cr+₹33.2 L (15.5%)Rejected-Finance | ₹2.5 Cr+₹33.2 L (15.5%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹2.6 Cr+₹45.4 L (21.2%)Rejected-Finance NAKARI BORIGAON SIDING JORHAT 785001 ASSAM | JORHAT | JORHAT | ASSAM | 785001 | ₹2.6 Cr+₹45.4 L (21.2%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹2.7 Cr+₹52.1 L (24.3%)Rejected-Finance H NO 6 1ST FLOOR P B ROAD SUHAGPUR REBARARI GUWAHATI 08 | GUWAHATI | ₹2.7 Cr+₹52.1 L (24.3%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹3.3 Cr+₹1.2 Cr (54.8%)Rejected-Finance | ₹3.3 Cr+₹1.2 Cr (54.8%) | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | HVAC Engineering Co L2 | Parksons Engineering Company Pvt Ltd L5 | RS COOLING APPLIANCES L4 | Flint India L1 | HEMONTA DAS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing & commissioning of Air cooled floor mounted package air conditioners unit of Capacity- 11 TR - 03 Nos (2 Working + 1 Standby) to operate from 415 ±10% volt, 50 Hz, 3 Phase power supply and consisting of hermitically sealed fixed speed scroll compressor complatible of R 410A as refrigerant. The indoor unit will consist of evaporator coil, expansion valve capillary, fixed speed scroll compressor and in outdoor unit will consist of condenser fan and condenser copper coil complete in respect. Both the indoor & outdoor unit will be connected using refrigerant piping and control cabling.
(a) Indoor & outdoor unit installation, testing by nitrogen & commissioning of capacity 11 TR - 03 Nos
(b) canvas connection - 03 Nos
(c) Hard/soft copper pipe between indoor & outdoor 15 mtr each of 3/8" & 7/8" dia - 45 RM each
(d) PVC Drain piping with 6 mm Nitrile rubber insulation 25 mm - 30 RM
(e) Communication cable between indoor & outdoor 3 coreX1.5 Sqmm CU communication cable - 50 RM
(f) GI ducting 24 Gauge rectangular site fabricated - 200 Sqm
(g) GI ducting 22 Gauge rectangular site fabricated - 50 Sqm
(h) Duct accoustic insulation with 15 mm thick rigid board + tissue paper + perforated sheet - 50 Sqm
(j) Duct thermal insulation with 13 mm thick closed cell O class Nitrile rubber - 200 Sqm
(k) GI back draft dampers - 03 Nos
(l) AI powder coated Grilles/Diffusers with VCD - 4 Sqm
(m) AI powder coated Grilles/Diffusers with out VCD - 5 Sqm
(n) SITC of Duct Heater 7.5 KW X 2 with necessary control device thermostat, humidstat and airstat for controlling RH.
(o) Refrigerant gas charging R 410A - 45 KG
(p) Controal panel for heater with humidstat, thermostat and airstat - 01 Nos.
NOTE:- (i) The air conditioning system must maintain Temperature range: 21+ 4 °C & Relative Humidity range: 55 +10%.
(ii) Angel iron for supporitng ducts and units deemend to be included in the quoted rates. | 2 | Each Job | 25,00,000 ₹50,00,000 Lowest | 55,30,000 ₹1,10,60,000 | 45,00,000 ₹90,00,000 | 25,50,000 ₹51,00,000 | 46,00,000 ₹92,00,000 |
| 2.00 | Supply, installation, testing and commissioning of Air cooled condensing type air conditioner of capacity
8.5 TR - 03 Nos (02 Working +01 Stand by), comprising of an outdoor unit consisting of compressor, air cooled condenser, condenser fans connected with AHU through copper pipes, control cables, control panel, wiring, installation and with full charge of refrigerant gas.
(a) Installation, Testing and commissioning of Air handling unit of 6400 CFM/17 TR/6 Row Deep coil/ with Pre Filter Floor mpounted AHU/ 32mm Double Skin AHU - 01 Nos
(b) Installation, testing and commissioning of Expansion valve, Dryers, Looking glass - 03 Nos
(c) Supply, Installation, testing & commissioning of volume control damper - 02 Nos
(d) Refrigerant R -410 A for top up in VRF system - 24 Kg
(e) SITC of refrigerant piping with 19/13 mm thick nitril rubber insulation for suction line & liquid line - 90RM
(f) HDPE drain piping 32 mm with insulation - 25 RM
(g) Supply & installation of GI ducting, site fabricated rectangular ducts, complete with silicon sealant joints with necessary supports using thread roads and anchor bolts of size 24 SWG - 265 SQM
(h) Accoustic Insulation with open cell nitril rubber with 15 mm thick - 55 SQM
(j) Thermal insulation of the duct with 13mm thick nitril rubber- 250 SQM
(k) Supply & fixing of Al extruted powder coated supply Air Grill/Diffuser with volume control damper & necessary supporting arrangrment - 7.5 SQMT
(l) Supply & fixing of AI extruted powder coated return air grill/diffuser without volume control damper & necessary supporting arrangement - 7.5 SQMT
(m) Strip heater duct mounted for AHUs with necessary control device thermostat, Humidistat and Airstat for controlling RH - 01 Nos
(n) Control panel for AHU with IDU controller - 01 Nos
(o) Control Panel for heater with thermostat, humidistat and airstat - 01 Nos
(p) Control communication cable 6CX1.5 Sqmm copper for ductable IDU unit- 50 RM
(q) Supply & installation of fusible link fire damprer - 01 Nos
NOTE:- (i) The air conditioning system must maintain Temperature range:23+ 5 °C & Relative Humidity range: 60+ 5%.
(ii) Angel iron for supporitng ducts and units deemend to be included in the quoted rates. | 1 | Each Job | 26,00,000 ₹26,00,000 Lowest | 35,50,000 ₹35,50,000 | 30,00,000 ₹30,00,000 | 35,41,000 ₹35,41,000 | 33,00,000 ₹33,00,000 |
| 3.00 | Supply, install, testing & commissioning inverter type split type Air Conditioner of 1.5 TR capacity with remote control unit, anti dust filter and features like turbo cool, humidity control, anti rust coating, self diagnosis, sleep mode, adjustable cooling for better indoor air quality with minimum 5 Star rating and ISEER above 3.5, complete all as specified & as directed. | 33 | Each | 68,000 ₹22,44,000 | 76,000 ₹25,08,000 | 65,000 ₹21,45,000 | 47,800 ₹15,77,400 Lowest | 65,000 ₹21,45,000 |
| 4.00 | Supply, install, testing & commissioning inverter type split type Air Conditioner of 2 TR capacity with remote control unit, anti dust filter and features like turbo cool, humidity control, anti rust coating, self diagnosis, sleep mode, adjustable cooling for better indoor air quality with minimum 5 Star rating and ISEER above 3.5, complete all as specified & as directed. | 24 | Each | 92,000 ₹22,08,000 | 85,000 ₹20,40,000 | 70,000 ₹16,80,000 | 66,500 ₹15,96,000 Lowest | 98,000 ₹23,52,000 |
| 5.00 | Supply, install, testing & commissioning inverter type window type Air Conditioner of 1.5 TR capacity with remote control unit, anti dust filter and features like turbo cool, humidity control, anti rust coating, self diagnosis, sleep mode, adjustable cooling for better indoor air quality with minimum 5 Star rating and ISEER above 3.5, complete all as specified & as directed. | 11 | Each | 58,000 ₹6,38,000 | 58,000 ₹6,38,000 | 40,000 ₹4,40,000 Lowest | 43,000 ₹4,73,000 | 60,000 ₹6,60,000 |
| 6.00 | Supply & install, testing & compressioning refrigeration type dehumidifier of capacity 24000 BTU, air flow rate 1700 CFM, moisture removal 65 ltrs/day using R-134A gas, complete all as specified & as directed. | 8 | Each | 1,00,000 ₹8,00,000 | 3,73,000 ₹29,84,000 | 28,500 ₹2,28,000 Lowest | 1,85,000 ₹14,80,000 | 1,50,000 ₹12,00,000 |
| 7.00 | Supply and fixing water cooler electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour, complete all as specified & as directed. | 13 | Each | 78,000 ₹10,14,000 | 76,000 ₹9,88,000 | 58,000 ₹7,54,000 | 54,600 ₹7,09,800 | 50,000 ₹6,50,000 Lowest |
| 8.00 | Supply and fixing water cooler electric driven (single phase), having approx storage capacity of 150 litres and nominal cooling capacity of 150 Litres per hour, complete all as specified & as directed. | 7 | Each | 1,00,000 ₹7,00,000 | 85,000 ₹5,95,000 | 61,000 ₹4,27,000 Lowest | 81,900 ₹5,73,300 | 65,000 ₹4,55,000 |
| 9.00 | Supply and fixing water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour, complete all as specified & as directed. | 12 | Each | 66,000 ₹7,92,000 | 67,000 ₹8,04,000 | 62,000 ₹7,44,000 | 44,200 ₹5,30,400 Lowest | 45,000 ₹5,40,000 |
| 10.00 | Supply and fixing refrigerator, electric driven (single phase), capacity upto 185 ltrs single door with base stand drawer, smart inverter compressor, smart connect, toughened glass shelves with 5 star rating, complete all as specified and as directed. | 9 | Each | 30,000 ₹2,70,000 | 58,000 ₹5,22,000 | 30,000 ₹2,70,000 | 22,700 ₹2,04,300 Lowest | 25,000 ₹2,25,000 |
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
28 Oct 2025, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
SPECIAL REPAIR/ REPLACEMENT OF BER COOLING APPLIANCES AT VARIOUS LOCATIONS AT AFS JORHAT
2025_MES_730762_1
88686/JOR/E8
Open Tender
Civil Works
Item Rate
365 days
Jorhat
As per Tender documents
8 documents required · 8 mandatory
₹2,000
GE (AF) JORHAT
₹3.5 L
Yes
28 Jan 2026
13 Sept 2025
30 Oct 2025
13 Sept 2025
28 Oct 2025
21 Oct 2025
Amount
Supply, installation, testing & commissioning of Air cooled floor mounted package air conditioners unit of Capacity- 11 TR - 03 Nos (2 Working + 1 Standby) to operate from 415 ±10% volt, 50 Hz, 3 Phase power supply and consisting of hermitically sealed fixed speed scroll compressor complatible of R 410A as refrigerant. The indoor unit will consist of evaporator coil, expansion valve capillary, fixed speed scroll compressor and in outdoor unit will consist of condenser fan and condenser copper coil complete in respect. Both the indoor & outdoor unit will be connected using refrigerant piping and control cabling. (a) Indoor & outdoor unit installation, testing by nitrogen & commissioning of capacity 11 TR - 03 Nos (b) canvas connection - 03 Nos (c) Hard/soft copper pipe between indoor & outdoor 15 mtr each of 3/8" & 7/8" dia - 45 RM each (d) PVC Drain piping with 6 mm Nitrile rubber insulation 25 mm - 30 RM (e) Communication cable between indoor & outdoor 3 coreX1.5 Sqmm CU communication cable - 50 RM (f) GI ducting 24 Gauge rectangular site fabricated - 200 Sqm (g) GI ducting 22 Gauge rectangular site fabricated - 50 Sqm (h) Duct accoustic insulation with 15 mm thick rigid board + tissue paper + perforated sheet - 50 Sqm (j) Duct thermal insulation with 13 mm thick closed cell O class Nitrile rubber - 200 Sqm (k) GI back draft dampers - 03 Nos (l) AI powder coated Grilles/Diffusers with VCD - 4 Sqm (m) AI powder coated Grilles/Diffusers with out VCD - 5 Sqm (n) SITC of Duct Heater 7.5 KW X 2 with necessary control device thermostat, humidstat and airstat for controlling RH. (o) Refrigerant gas charging R 410A - 45 KG (p) Controal panel for heater with humidstat, thermostat and airstat - 01 Nos. NOTE:- (i) The air conditioning system must maintain Temperature range: 21+ 4 °C & Relative Humidity range: 55 +10%. (ii) Angel iron for supporitng ducts and units deemend to be included in the quoted rates.
Supply, installation, testing and commissioning of Air cooled condensing type air conditioner of capacity 8.5 TR - 03 Nos (02 Working +01 Stand by), comprising of an outdoor unit consisting of compressor, air cooled condenser, condenser fans connected with AHU through copper pipes, control cables, control panel, wiring, installation and with full charge of refrigerant gas. (a) Installation, Testing and commissioning of Air handling unit of 6400 CFM/17 TR/6 Row Deep coil/ with Pre Filter Floor mpounted AHU/ 32mm Double Skin AHU - 01 Nos (b) Installation, testing and commissioning of Expansion valve, Dryers, Looking glass - 03 Nos (c) Supply, Installation, testing & commissioning of volume control damper - 02 Nos (d) Refrigerant R -410 A for top up in VRF system - 24 Kg (e) SITC of refrigerant piping with 19/13 mm thick nitril rubber insulation for suction line & liquid line - 90RM (f) HDPE drain piping 32 mm with insulation - 25 RM (g) Supply & installation of GI ducting, site fabricated rectangular ducts, complete with silicon sealant joints with necessary supports using thread roads and anchor bolts of size 24 SWG - 265 SQM (h) Accoustic Insulation with open cell nitril rubber with 15 mm thick - 55 SQM (j) Thermal insulation of the duct with 13mm thick nitril rubber- 250 SQM (k) Supply & fixing of Al extruted powder coated supply Air Grill/Diffuser with volume control damper & necessary supporting arrangrment - 7.5 SQMT (l) Supply & fixing of AI extruted powder coated return air grill/diffuser without volume control damper & necessary supporting arrangement - 7.5 SQMT (m) Strip heater duct mounted for AHUs with necessary control device thermostat, Humidistat and Airstat for controlling RH - 01 Nos (n) Control panel for AHU with IDU controller - 01 Nos (o) Control Panel for heater with thermostat, humidistat and airstat - 01 Nos (p) Control communication cable 6CX1.5 Sqmm copper for ductable IDU unit- 50 RM (q) Supply & installation of fusible link fire damprer - 01 Nos NOTE:- (i) The air conditioning system must maintain Temperature range:23+ 5 °C & Relative Humidity range: 60+ 5%. (ii) Angel iron for supporitng ducts and units deemend to be included in the quoted rates.
Supply, install, testing & commissioning inverter type split type Air Conditioner of 1.5 TR capacity with remote control unit, anti dust filter and features like turbo cool, humidity control, anti rust coating, self diagnosis, sleep mode, adjustable cooling for better indoor air quality with minimum 5 Star rating and ISEER above 3.5, complete all as specified & as directed.
Supply, install, testing & commissioning inverter type split type Air Conditioner of 2 TR capacity with remote control unit, anti dust filter and features like turbo cool, humidity control, anti rust coating, self diagnosis, sleep mode, adjustable cooling for better indoor air quality with minimum 5 Star rating and ISEER above 3.5, complete all as specified & as directed.
Supply, install, testing & commissioning inverter type window type Air Conditioner of 1.5 TR capacity with remote control unit, anti dust filter and features like turbo cool, humidity control, anti rust coating, self diagnosis, sleep mode, adjustable cooling for better indoor air quality with minimum 5 Star rating and ISEER above 3.5, complete all as specified & as directed.
Supply & install, testing & compressioning refrigeration type dehumidifier of capacity 24000 BTU, air flow rate 1700 CFM, moisture removal 65 ltrs/day using R-134A gas, complete all as specified & as directed.
Supply and fixing water cooler electric driven (single phase), having approx storage capacity of 120 litre and nominal cooling capacity of 60 Litres per hour, complete all as specified & as directed.
Supply and fixing water cooler electric driven (single phase), having approx storage capacity of 150 litres and nominal cooling capacity of 150 Litres per hour, complete all as specified & as directed.
Supply and fixing water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour, complete all as specified & as directed.
Supply and fixing refrigerator, electric driven (single phase), capacity upto 185 ltrs single door with base stand drawer, smart inverter compressor, smart connect, toughened glass shelves with 5 star rating, complete all as specified and as directed.
Supply and fixing refrigerator, electric driven (single phase), capacity upto 270 ltrs double door with key features including smart diagnosis, smart connect, convertible, multi air flow, smart inverter compressor with 3 star rating, complete all as specified and as directed.
Supply and fixing refrigerator, electric driven (single phase), capacity upto 320 ltrs double door with key features including smart diagnosis, door cooling, Wi Fi convertible, multi air flow, smart inverter compressor with 3 star rating, complete all as specified and as directed.
Supply and fixing refrigerator, electric driven (single phase), capacity upto 380 ltrs double door with key features including smart diagnosis, door cooling, Wi Fi convertible, multi air flow, Smart inverter compressor with 3 star rating, complete all as specified and as directed.
Supply and fixing deep freezer hard top 320 litre capacity having double door, temperature range +8°C to -26°C environment friendly refrigerant gas, antibacterial gasket, 5 star rating, complete all as specified & as directed.
Supply and fixing voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 150V to 285 V with output voltage stabilzed at 230 V with accuracy of ± 2.5 % and suitable for one air conditioner up to 2 Ton or 24000 BTU/Hour, complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 150V to 285 V with output voltage stabilzed at 230 V with accuracy of ± 2.5 % and suitable for one air conditioner up to 1.5 Ton or 18000 BTU/Hour, complete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation,single phase naturally air cooled indoor type & designed for input variation between 130V to 290 V with output voltage stabilzed at 230 V with accuracy of ± 2.5 % and suitable for one refrigerator or deep freezer upto 600 ltrs capacity, complete all as specified and directed.
Supply & fixing GI pipe medium grade of 15 mm bore laid in walls and ceilings or laid in floor including necessary fittings/fixture like Tee, Bend, Sicket, Union, Nipple etc. & necessary connections, complete all as specified and directed.
Supply and fixing Stop valves of 15 mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified & directed.
Dismantling of 15 TR (2 X 7.5 TR working & 1X 7.5 TR as stand by) central AC plant at DB 6 and transporting back to MES store, complete all as specified & directed.
Dismantling of 22 TR (2X 11 TR working & 1X 11 TR as stand by) central AC plant at different locations and transporting back to MES store, complete all as specified & directed.
Supply & fixing RO based water purifier of capacity 14 ltrs per hour, complete all as specified & directed.
Taking down old unserviceable Split / Window AC/ dehumidifier along with Voltage stabilzer and transporting back to MES store, complete all as specified and directed.
Taking down old unserviceable water cooler , refrigerator , RO and deep freezer along with voltage stabilizer and transporting back to MES store of any capacity, complete all as specified and directed.
Taking down old unserviceable GI Pipe of 15mm dia. including accessories, stope valve of any capacity, complete all as specified and directed.
Taking down carefully point wiring for light fan, socket complete including battens and fittings such as switch , ceiling rose, light fittings, regulators, socket, etc. and making good of disturbe surface of walls/ floors, complete all as specified and directed.
Taking down carefully single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V AC and making good of disturbe surface of walls/ floors, complete all as specified and directed.
Taking down carefully submain wiring including PVC casing caping, 4 Sqmm cable PVC insulated copper conductor multi-stranded or FRLS cable and making good of disturbe surface of walls/ floors, complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 V AC, complete all as specified and directed.
M&L for submain wiring including PVC casing caping 2 run 4 Sqmm cable PVC insulated copper conductor multi-stranded or FRLS cable drawn through PVC casing caping with all accessories including 4 Sqmm multi strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly, complete all as specified and directed.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 2.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694-1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 2.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for One independent 15 Amp socket point controlled by one 15 Amps switch one way, complete all as specified and directed.
Supply and fixing in repair/replacement of switch socket combination multipurpose, 2 in 1, 6 pin, 5 /15 Amp flush type, complete all as specified and directed.
Taking down old unserviceable LT panels, complete all as specified and directed.
Taking down old unserviceable LT UG cable of any size with bricks etc., complete all as specified and directed.
Taking down old unserviceable earthing of any type, complete all as specified and directed
Taking down old unserviceable voltage stabilizer any capacity and depositing the same to MES store, complete all as specified and directed
Design, supply, erection, testing and commissioning KIOSK outdoor type LT feeder pillar box, platform mounted, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Copper bus bar for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
(Srl Item No. 37.00 Contd...) BUS BARS AND INTERNAL CONNECTIONS : The bus bars shall be made of Copper,200 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP/SMC/DMC material. All phase bars and as well as the neutral bars also shall be of size 25mm x 5mm For all internal connections from main bus bars to switch gears shall be carried out with 1100 Volts grade FRLS PVC insulated copper wire of suitable size but not less than 1.5 times current carrying capacity of individual switch gears. The extended bars from switch gears to cable alley (for terminating the LT UG aluminium cables) shall be made of aluminium bars having suitable cross sectional area but not less than 1.5 times current carrying capacity of individual switch gears, they shall be duly insulated with 1100 volts grade standard colour coded PVC sleeves, 2 Nos earthing terminating points shall be provided in the side wall as per standard practice
(Srl Item No. 37.00 Contd...) PROVISION FOR CABLE ENTRY:- The provision for cable entry/exit shall be provided in the bottom for both incoming and outgoing cables. CONTROL WIRING : All control wirings shall have to be carried out with 1100 Volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50 Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. INCOMING : 4 pole MCCB having breaking capacity 36 KA of rating 80 Amps. - 01 No OUTGOINGS : (a ) 4 pole MCCB having breaking capacity 25 KA of rating 40 Amps. - 04 No INSTRUMENTATION SYSTEM :- (a) Digital multi function panel meter with measuring parrameters VLL, VLN, A, Hz, PF, Var, Harmonics (b) Current Transformer (CT) having ratio 100 / 5, indoor, tape wound, ring type with rated burden 5.0 VA. - 03 Nos (c) LED Pilot Lamp (for Incomers) suitable for 230/240 Volts AC supply complete with integral circuit & cluster LED of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (d) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 No
Design, supply, erection, testing and commissioning KIOSK outdoor type LT feeder pillar box, platform mounted, suitable for 3 phase 4 wire, 500 volts AC supply and having 4 Nos Copper bus bar for distribution system and type tested at CPRI, fabricated in factory having modern fabrication and testing facility which includes seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate duly compartmentalized for each control gear and bus-bar, front door (02 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings:-
(Srl Item No. 40.00 Contd...) BUS BARS AND INTERNAL CONNECTIONS : The bus bars shall be made of Copper,400 Amps rated, duly insulated with 1100 Volts grade standard colour coded PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP/SMC/DMC material. All phase bars and as well as the neutral bars also shall be of size 25mm x 5mm For all internal connections from main bus bars to switch gears shall be carried out with 1100 Volts grade FRLS PVC insulated copper wire of suitable size but not less than 1.5 times current carrying capacity of individual switch gears. The extended bars from switch gears to cable alley (for terminating the LT UG aluminium cables) shall be made of aluminium bars having suitable cross sectional area but not less than 1.5 times current carrying capacity of individual switch gears, they shall be duly insulated with 1100 volts grade standard colour coded PVC sleeves, 2 Nos Earthing terminating points shall be provided in the side wall as per standard practice.
(Srl Item No. 40.00 Contd...) PROVISION FOR CABLE ENTRY :- The provision for cable entry/exit shall be provided in the bottom for both incoming and outgoing cables. CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. INCOMING : 4 pole MCCB having breaking capacity 36 KA of rating 100 Amps. - 01 No OUTGOINGS : (a ) 4 pole MCCB having breaking capacity 25 KA of rating 40 Amps. - 5 No INSTRUMENTATION SYSTEM :- (a) Digital multi function panel meter with measuring parrameters VLL, VLN, A, Hz, PF, Var, Harmonics (b) Current Transformer (CT) having ratio 200 / 5, indoor, tape wound, ring type with rated burden 5.0 VA. - 03 Nos (c) LED Pilot Lamp (for Incomers) suitable for 230/240 Volts AC supply complete with integral circuit & cluster LED of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (d) Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 No
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100V (earthed) grade with stranded aluminium conductor of size 150 Sqmm 3.5 core all as per IS:7098(Pt-II), complete all as specified and directed. NOTE: Earth work, cable cover, sand cushioning shall be measured and paid seperately under respective items.
Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected te and including galvanised iron strip 32x6mm as earthing lead by means of bots. nuts. check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame, work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia. MS fabricated handle, medium grade Gl watering pipe 20mm bore with funnel, wire mesh and light grade Gl protection pipe 15mm bore upto 5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion, complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100V (earthed) grade with stranded aluminium conductor of size 25 Sqmm 4 core all as per IS:7098(Pt-II), complete all as specified and directed. NOTE: Earth work, cable cover, sand cushioning shall be measured and paid seperately under respective items.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
Supply and spreading dry coarse sand in trenches for protection of underground electric cable, spread in uniform 23 cm thickness and punned down gently to 18 cm complete all as specified and as directed. Note:- Punned thickness will be measured at the time of measurement and payment.
M&L for sub-class B old size brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, complete all as specified and as directed.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
M&L for cement concrete PCC 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete, complete all as specified and as directed .
M&L for cutting the road/hard standing and making good disturbed surfaces by using PCC (1:3:6) type C-2 by using 40 mm graded stone aggregate for the fixing the pipe, complete all as specified and as directed .
Supply and fixing of GI steel tubing of size 50 mm dia., light grade with all fittings, laid in trenches/wall for protection of cables, complete all as specified and as directed .
S&F in repair XLPE cable tray made of GI metal heaving breadth and height 50 mm x 38 mm including fixing brackets, riser, complete all as specified and directed.
Supply and fix Voltage stabilizer of 50 KVA capacity, automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second, complete all as specified and directed.
Supply and fix Voltage stabilizer of 100 KVA capacity, automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second, complete all as specified and directed.
Supply and fix Voltage stabilizer of 150 KVA capacity, automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second, complete all as specified and directed.
Note:- Schedule of credit (Sch 'A' Part- II) amount of Rs 47,047.00 shall be deducted from the total quoted amount of BOQ.
HVAC Engineering Co (BID ID -3484899)
HEMONTA DAS (BID ID -3486693)
RS COOLING APPLIANCES (BID ID -3486951)
Parksons Engineering Company Pvt Ltd (BID ID -3485132)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Tendernotice_2.pdf
PDF • 0.32 MB
Tender.pdf
Tender Documents • 1.52 MB
BOQ_818134.xls
BOQ • 0.86 MB
Corrigendum_3.pdf
PDF • 0.25 MB
Corrigendum_2.pdf
PDF • 0.25 MB
Corrigendum_1R.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .