Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC DAIRY FARM POST BOX NO 441 JUNGLIGHAT POST SRI VIJAYA PURAM 744103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹27.2 L+₹3.6 L (15.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.1 L+₹4.5 L (19.3%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹28.5 L+₹5.0 L (21.1%)Rejected-AOC WARD NO 1 CALICUT PORT BLAIR SOUTH ANDAMAN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-AOC L4 | |
| 5 | L5₹29.3 L+₹5.7 L (24.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
5 Sept 2022, 6:00 pmClosed
GARRISON ENGINEER BRICHGUNJ
GARRISON ENGINEER BRICHGUNJ PORT BLAIR-744103
SPECIAL REPAIR OF BUILDING NUMBER P-225 A COOK HOUSE STORE ROOM AT 282 I FD WKSP COY EME AT BRICHGUNJ MILITARY STATION PORTBLAIR
2022_MES_545521_1
8267A
Open Tender
Civil Works
Item Rate
120 days
GARRISON ENGINEER BRICHGUNJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹5,000
GARRISON ENGINEER BRICHGUNJ
₹50,000
Yes
19 Sept 2022
16 Aug 2022
7 Sept 2022
16 Aug 2022
5 Sept 2022
30 Aug 2022
16 Aug 2022 - 30 Aug 2022
Amount
Demolition of brick work built in cement mortar or lime mortar complete of any description complete all as specified and as directed.
M&L Precast Cement Concrete Block Masonry with Solid Block, exc 10cm in width in type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specified complete all as directed.(plinthprotection)
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in plinth protection, surface finished even and smooth without using extra cement, laid in panels complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing the rubbish off the premises complete all as specified and as directed.
M&L 25mm thk PCC 1:2:4 type B-0 using 12.5 mm graded agg as in flooring finished fair and even without using extra cement complete all as specified and as directed.
M & L for Dark coloured vitrified tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles n exc. 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed with coloured or white cement to match including screed bed 15mm thick 1:4, complete all as specified and as directed by Engineer-in-Charge.
All as per item no 07.00 here in before but on vertical surfaces including 10mm thick CM 1:3 as in backing coat of dado/Skirting complete all as specified and as directed.
M&L non skid ceramic tiles 7 to10mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm and not exceeding 0.38 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over 15mm thick screed bed in CM 1:4
All as per item No 09.00 here in before, but on vertical surfaces incl 10mm thick CM 1:3 as in baking coat of dado/skirting complete all as specified and as directed.
M&L for coloured glazed ceramic tiles, (350 x 250mm) x 7mm and 450x350x7mm thick on vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tile over and including rendering 10mm thick in CM 1:3 complete all as specified and as directed by Engineer-in-Charge.
M & L Chequered cement concrete tiles, with grey cement and pigment 30cm x30cm x20mm thick set, jointed and pointed in neat cement slurrry in floors including 15mm thick screed bed in Cm 1:4 all as specified and directed.
M&L for 20mm thick Granite of any type work table rubbed and polished in steps, jambs , pillars, cooking platforms and the like including pointing with white cement 1:2 using marble dust with admixture of pigment to match with shade of granite including Screed bed of coat 20mm thick CM (1:4) complete all as specified and as directed.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Taking down cement plaster on Brick / Concrete surfaces incl raking out joints, hacking for key scrubbing down with water and Removing Rubbish out side of the MD Land all as directed by Engineer-in-Charge.
M&L Rendering 10mm thick on internal sides wall of Brick / Concrete Surfaces in CM (1:6) finished even & smooth without using extra cement complete all as specified and as directed.
M&L Rendering 15mm thick on External sides of wall of Brick / Concrete Surfaces in CM (1:6) with level plast including 3 to 5% of water proofing compound finished even & smooth without using extra cement.( Note Waterproofing compound and level plast paid separately) Complete all as specified and directed.
M & L for rendering 5 mm thick in CM I:3 on for ceiling surfaces, finished even and smooth without using extra cement etc complete all as specified and as directed.
M&L for oil bound distempering two coats over a coat of alkali resistant priming paint including preparation of new plastered or unplastered surfaces of wall complete all as specified and directed by Engineer - in -Charge.
M & L for Complete removal of existing treatment and preparing old surfaces for applying two coat of oil bound distemper on one coat of primer over a coat of pytty on walls all as specified and directed.
All as per item no 19.00 here in before but but on ceiling complete all as specified and as directed.
All as per item no 20.00 here in before but but on ceiling surfaces complete all as specified and as directed.
Preparation of old external surfaces of walls, Facias, cornices etc and applying one coat of weather proof anti fungal paint (Apex - ultima) on coat of external wall putty on walls all as per manufacturer instruction and as directed by Engineer-in-Charge.
M& L for Finishing walls with Acrylic smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) etc complete all as specified and as directed by Engineer-in-Charge.(Make Apex Ultima)
M&L in repairs water proofing treatment to RCC roof by priming the plastered surfaces with a coat of cold applied bituminous primer conforming to IS 2488 @ 0.30 kg/sqm and laying APP modified five layer polymeric membrane 3mm thick of minimum wt. 3.50 kg/sqm reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) laid by torch application as per the manufacturers instructions with side overlap of 75mm & end overlap of 100mm & tucked into the chases on vertical surfaces to a height of 300mm & finally finished with bituminous aluminium paint @ 0.10 kg/sqm complete including taking down existing roof treatment all as specified and as directed.
M&L for 25 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in padding to roof slab and rendering 5 mm thick in one layers on concrete surface cement sand mortar 1:3 using water proofing compound @ 3% by weight of cement finished even fair and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. Note:WPC will be measured and paid separately.
Supply only integral water proofing compound complete all as specified and as directed by Engineer-in-Charge.
M&L for providing 100mm thick cement concrete 1:4:8 type D2 using 40mm graded stonne aggregate as in sub base of flooring complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 SqM with shutters (Without taking off shutters & Grill from the frame).
Taking down chowkats or frames exceeding exc 1.5 sqm but nexc 4sqm each (Without taking off shutters & Grill from the frame).
S & F Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed by Engineer-in-charge.(Aluminium section shall be of make Jindal/Hindalco/ Indalco). (Note:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted. Glass panels, prelaminated particle boards, aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply only 4 mm thick sheet figured glass and glazing with rubber packing around the glass, in squares exceeding 0.50 sqm in each pane complete all as specified and as directed.
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed
S & F MS Steel work in tubular trusses and tubular posts/ purlins including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to IS :1161-1979 grade st-240 including notching, drilling, fitting, riveting and/or welding or connecting with bed plate, bolt and nuts complete all as specified and as directed
M & L For prepatring New steel/ Iron surfaces of any description exc 10cm Width or Girth and applying two coats of synthatic enamel paint over one coat of Redoxide primer complete all specifiedcand directed.
M & L for prepatring Old steel/ Iron surfaces of any description exc 10cm Width or Girth and applying two coats of synthatic enamel paint over one coat of Redoxide primer complete all specifiedcand directed.
Dismantling for plain or corrugated roof sheeting of any description, any gauge, thickness, including Removing L-type or J-type bolts in Roof Covering.
S&F Pre-painted galvalume aluminium zinc coating GI based (corrugated/semi corrugated) sheet 0.50mm thick as per approved profile, coloured, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking up or down, 15mm dia bore, GI tubing, medium grade, including cleaning for refixing or removing from site, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix UPVC 25mm bore pipes of pressure rating 10 Kgf/Sqcm fixed with all fittings and fixed to walls and ceillings or laid in floors etc complete all as specified and as directed.
Supply and fix UPVC 20mm bore pipes of pressure rating 10 Kgf/Sqcm fixed with all fittings and fixed to walls and ceillings or laid in floors etc complete all as specified and as directed.
Cutting chases, pinning in , making good to facings for concealed water tubing and pointing in CM 1:3, cutting not exc 10 cm girth complete all as specified and as directed.
S&F in repairs Aluminium anodised chromium plated tubular towel rail, 20mm dia, D type, 60cm long, between flanges including suitable bracket complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repairs stainless steel gratings 125mm dia, complete all as specified and as directed
S & F in repairs Rototional moulded polythylene water storage tanks 1000ltr double layer (cylidrical verticial with closed top) including float valve hoisted and fixed in postion including removing /dismantling of old water tank complete all as specified and as directed.
S&Fin repar aluminium composite panel sheet of 3mm to 4mm thick, fixed on existing aluminium frame work with plastic strips (double sided sticker) of suitable size of varying thickness of 10mm to 30mm including aluminium frame work, applying adhesive over aluminium sections for fixing composite panel and fixed with screws. The joints of panels shall be filled with weather proof sealant,The board shall be stuck with a layer of any colour high intensity reflective grade polymer sticker installed using epoxy adhesive, complete all as specified and as directed.
S&F in repairs Bib tap long body cast copper alloy chromium plated 15mm dia with fancy type screwed down screwed for iron pipe or brass ferule etc complete all as specified and as directed by Engineer-in-Charge
S&F in repairs sink with drainage board made up of stainless steel 1mm thick for kitchen or laboratory with plug washers and waste fittings including bedding in CM 1:3 into dwarf wall or cantilever brackets and connecting union to pipe over all size 915mm x 460mm, bowl size 410 x 330 x 160mm etc complete all as specified and as directed by Engineer-in-Charge
Taking down carefully, copper/aluminium point wiring (Light, fan, scoket or power) complete, including fittings and fixtures such as switches, ceiling roses, regulators, sockets etc., and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by Engineer-in-Charge.
M & L for point wiring complete with single core multi stranded Copper conductor FRLS cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit suitable size including Tee junction bends etc concealed in wall/fixed on ceiling and PVC switch board hylam sheet of 3mm thick including M.S. sunken boards of suitable size for housing switched sockets etc including 1.5 sqmm. green PVC insulated wire for earth continuty. including Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills sunshades, shelves, lintels, etc.; and cutting chases for concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth in brick wall. complete all as specified and as directed by Engineer-in-Charge . One light point/Exhaust fan point controlled by one switch
One fan point controlled by one switch and one regulator
One 3 pin switch socket outlet point 5 amps on same board with other switches.
One 3 pin switch socket outlet point 5 amps on independent board.
All as per item at sl No.52.00 here in before but with copper conductor cable for one 3 pin socket outlet, 15 amps independent, with cable 4 Sqmm size and 4 Sqmm earth continuty conductor, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix switch piano flush type single pole one way 5 amps, complete all as specified and as directed by Engineer-in-Charge
Supply and fix switch socket outlet 3 & 2 pin (mult pin) 5 amps flush/box type, complete all as specified and as dircted by Engineer-in-Charge
Supply and fix switch socket outlet, 2 in 1, 3 pin 15 and 5 amps, controlled by one switch flush/box type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface baklite 65 x 50 mm 3 terminal, complete all as specfified and as directed by Engineer-in-Charge
Supply and fix lamp holder(angle type) PVC body with back plate suitable for batten fittings, complete all as specified and as directed Engineer-in-Charge
Supply and fix fan speed regulator, electronic suitable for single phase AC, 240 volts, 50 Hz,100 watts, complete all as specified and as directed by Engineer-in-Charge
Taking down and refixing ceiling fan and connecting up including provision of cable from ceililng rose or connector to fan complete all as specified and as directed.
Taking down and refixing old serviceable exhaust fan and connecting up including provinding of cable from ceiling rose/connector to fan complete all as specified and as directed.
Supply and fix energy efficient LED Smart bright batten 22 watt fitting 4ft in length nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including lamp and connecting with twin core shethed cable from fitting to ceiling rose all as specified and as diected.
S&F 25 W New genration energy saving & envoirmental friendly long life versatile pressure dia cast aluminium IP65 road way luminaire with high power LEDs as light and electronic driver complete with necessary brackets (made out of 25 mm bore GI light grade pipe approx. 0.6 M long) nuts, bolts etc to be fixed as on walls complete as directed.
Supply & fix in repair LED holder type non dimmable bulb 10 watt complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair metal enclosure distribution board SPN, 8 way 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs, including taking down old MCB/DB, complete all as as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 32 Amps, all as specified and as directed.
Supply and fix MCB SPN 240 volts, 5 to 32 Amps, all as specified and as directed.
M & L for sub main wiring complete with two runs of 6 Sqmm FRLS single core PVC insulated insheathed single core cable 1100 volts grade, multistranded with copper conductor (ISI Marked) drawn through and including PVC Casing and caping and all accessories fixed to wall/ roofs/ floors etc with one run of 6.0 sqmmm FRLS single core multistranded copper conductor as earth continuity conductor, including dismantling unserviceable sub main wiring including accessories,complete all as specified and as directed by Engineer-in-Charge. Note : (1) Two runs of cable one run of conduit & one run of earth continuity conductor shall be measured as one running metre.
AMR TRADERS
P M BUILDERS
SEVEN HILLS INDUSTRY
Nirman Construction Company
Sree Tirumala Enterprises
P NAIDU
KBR CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .