Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.5 L+₹2.5 L (5.84%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹47.8 L+₹5.8 L (13.8%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹48.4 L+₹6.4 L (15.3%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹48.6 L+₹6.6 L (15.8%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
11 Jul 2025, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-Garhi, Pin-182121
Repair/Maint of LT Switch gear and connected items at Northern part of Garrison under GE (Utilities) Udhampur
2025_MES_714404_1
GE/U-39/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹99,000
1 Aug 2025
13 Jun 2025
14 Jul 2025
13 Jun 2025
11 Jul 2025
27 Jun 2025
Amount
Supply, laying, jointing & testing in replacement XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade cross sectional area 10 Sqmm 2 core laind in trenches or passing through pipe or fixed on poles complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 1.00 here-in-before but of size 16 Sqmm 4 core.
Description all as per serial item No 1.00 here-in-before but of size 25 Sqmm 4 core.
Description all as per serial item No 1.00 here-in-before but of size 35 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 50 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 70 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 95 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 120 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 150 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 240 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 300 Sqmm 3.5 core.
Description all as per serial item No 1.00 here-in-before but of size 400 Sqmm 3.5 core.
Taking down the unserviceable LT cable of any size from tranches/ walls /floor etc complete all as specified and directed by engineer in charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes foundations of poles/stays/pipes etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engr-in-charge
Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-charge.
Removing of excavated soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
S&F double walled corrugated (DWC) pipe of size 180 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-charge
S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-charge
S&F double walled corrugated (DWC) pipe of size 90 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-charge
S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-charge
M&L for cement concreate 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in coping etc including necessary form work and finishing the surface with cement mortar 1:4, 5mm thick finished to the portion of PCC muffs above ground level complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:4:8 type D-2 (using 40 mm grade stone aggregrate in foundation, mass concrate) as in foundation of poles & stay etc complete all as specified and directed by Engr-in-Charge.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 40 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe complete all as specified and directed by Engineer-in-Charge.
Supply and Laying in replacement Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe, complete all as specified and directed by Engineer-in-Charge.
Dismantling of unserviceable steel tubular pole swaged pole/PCC pole including PCC complete with acessories complete all as specified and directed by Engr-in-Charge.
S&F in replacement erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-31, 9mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engr-in-Charge. Note: - (a) Excavation and Earth Work, PCC in foundation shall be measured and paid for separately.
Cleaning the existing exposed surfaces of steel tubular pole of 9.0 mtr long including cross arms, brackets, clamps etc and painting with two coats of synthetic enamel paint (Aluminium shade) marking five black & white bands at lower portion of pole, each 300 mm wide alternately and marking pole No. with yellow paint on black base at suitable height complete all as specified and directed by Engr-in-Charge.
Supply, installation, testing and commissioning in repair of outdoor type,weather proof, LT Panel made out of 3.15 mm thick CRCA steel sheet mounted on 60 cm long legs made out of 50 x 50 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory febricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Labour only for re-stretching properly sagged/loose ACSR conductor of any size fixed on LT poles by means of machine method to the permissible limit at different location including tightening of cross arms or D clamps and binding with new binding wire, tightening of jumpers complete all as specified and directed by Engr-in-Charge. Note: - (i) Each line of conductor shall be measured.(ii) Rate including unwinding of old winding wire and rewind with new binding wire after restretching)
S&F in replacement Shackle type porcelain vitreous white, brown or green insulator of size 75 mm height & 90 mm dia including galvanized mild steel straps of size 31 x 3 mm and bolt of size 12 mm dia, washers and nuts of 75 mm height & 90 mm dia for working pressure 1100 volts grade complete all as specefied and directed by Engr-in-charge.
S&F in replacement Pin type, porcelain, vitreous, white, brown or green insulator 1100 V grade including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and directed by Engineer-in-Charge.
M&L for defect rectification of LT 1.1 KV cable laid in trenches by locating fault with help of electronic fault locating machine comprising of surge generator pules, ECHO fault locator with high frequency distance calculator for cable of any size XLPE 11 KV / 1.1 KV complete all as specified and directed
Supply, jointing and testing Straight through cable joint heat shrinkable including all material and accessories suitable for 4 core X 25-95 Sqmm XLPE cable of 1100 volts (E)grade complete all as specified and directed. (Make / Model - Birla 3 M Ltd, raychem rpg) Note : Cost of Prepration of existing end deemed to be included in unit rate.
M & L in replacement for heat shrinkable straight through joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and as directed.
Description all as per serial item No: 34.00 here-in-before but LT cable size of 70 to 150 Sqmm.
Description all as per serial item No: 34.00 here-in-before but LT cable size of 185 to 240 Sqmm.
M & L in replacement for heat shrinkable End joint for PVC/XLPE insulated armoured cable of size upto 50Sqmm 3.5/4 core complete all as specified and as directed.
Description all as per serial item No: 37.00 here-in-beforebut LT cable size of 70 to 150 Sqmm
Description all as per serial item No: 37.00 here-in-before but LT cable size of 185 to 300 Sqmm
S&F in replacement Stay assembly complete with acessories as shown in electrical plate no 1 (loop type insulator, stay clamps, stay wire, excavation and concrete measured separately) with 16 mm dia stay rod complete all as specefied and directed by Engr-in-charge including taking down old U/S same items.
S&F in replacement Galvanized steel wire 4 mm dia for continious earth wire on poles and cradles at road crossing with fixing arrangement complete all as specefied and directed by Engr-in-charge.
S&F in replacement on LT overhead line separator 3 way complete all as specefied and directed by Engr-in-charge.
S&F in replacement on LT overhead line separator 4 way complete all as specefied and directed by Engr-in-charge.
M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT 20x15cm size complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB four pole 63 Amps,50 Hz with breaking capacity 16KA, Ics = 100% Icu , 415 Volts, Adjustable thermal & Fixed magnetic setting including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.
Description all as per serial item No 46.00 here-in-before but 100 Amps, 3P, with breaking capacity 16 KA.
Description all as per serial item No 46.00 here-in-before but 125 Amps with breaking capacity 16 KA.
Description all as per serial item No 46.00 here-in-before but 160 Amps with breaking capacity 36 KA.
Description all as per serial item No 46.00 here-in-before but 200 Amps with breaking capacity 36 KA.
Description all as per serial item No 46.00 here-in-before but 250 Amps with breaking capacity 36 KA.
Description all as per serial item No 46.00 here-in-before but 315 Amps with breaking capacity 36 KA.
Description all as per serial item No 46.00 here-in-before but 400 Amps with breaking capacity 36 KA.
Description all as per serial item No 46.00 here-in-before but 630 Amps with breaking capacity 36 KA.
S&F in replacement Ampere meter digital type of ratio 0-100 Amp, size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed by Engr-in-Charge.
S&F in replacement Voltmeter digital type of ratio 0-415 volt , size 95 Sqmm square type including making incoming/outgoing connections complete all as specified and directed by Engr-in-Charge.
M&L in replacement Indicator lamp assembly LED type with red/green/blue including making connections complete all as specified and directed by Engr-in-Charge.
M&L in replacement of Current transformer (CT) ratio 100/5 including making connections complete all as specified and directed by Engr-in-Charge.
S&F Onload change over switch FP 200 Amps, 415 Volt, 4 pole complete all as specefied and directed by Engr-in-charge.
S&F Onload change over switch FP 100 Amps, 415 Volt, 4 pole complete all as specefied and directed by Engr-in-charge.
S&F Onload change over switch FP 63 Amps, 415 Volt, 4 pole complete all as specefied and directed by Engr-in-charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32 x 6mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40 x 40 x 5 mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by the Engineer-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
S&F in replacement earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 32 x 6 mm complete all as specified and directed by Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 25 x 4 mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common salt including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20 mm bore and funnel with wire mesh light grade protection pipe 20 mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed by Engr-in-Charge. Note: - On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
S&F in replacement earth continuity conductor on main earthing lead fixed to pole or buried in ground or at any other situation for loop earthing extra as required (beyond 7.5 M) of GI Strip 25 x 4 mm complete all as specified and directed by Engr-in-Charge.
Supply & fixing in repair replacement for heat shrinkable Three finger breakout for suitable of PVC/XLPE insulated armoured cable in end of cabel of size upto 50Sqmm 3.5/4 core complete all as specified and directed by Engr-in-Charge.
Description all as per serial item No 64.00 here-in-before but LT cable size of 70 to 150 Sqmm.
M&L for switchyard gravelling of 15.0 cm (loose thickness) by broken stone of 40 mm size in and around two pole/ four pole structure/ substation complete all as specified and directed by Engr-in-Charge.
Taking out/dismantling any type of LT Panel by disconnecting the electric connection carefully after taking proper shutdown and removing from the site and stacking complete all as specefied and directed by Engr-in-charge.
M&L for ACSR conductor of required size for over head lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor, including taking down all as specified and diected by Engr in charge.Note: Retrived ACSR Conductor will be deposited at EM store yard with own arrangement by Contractor.
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 3x95 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply,lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 3x70sqmm + 1x50 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1100V grade stranded and compact aluminium phase conductor of size 3x 150sqmm + 1x120 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
M&L for Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site comple all as specified and directed by Engr in charge. Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsiblr to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c ) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will be responsible for any type mis-happening/accident while pruning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.
M&L for road cuttig existing road for crossing of underground electric cable for laying of any size GI tubing including necessary excavation and earth work including repairing the same as per existing with pre mix bituminious carpet complete all as specefied and as directed by Engr-in-charge. Note: - Width of trench shall be 15 cm and depth shall be upto 30 cm.
Supply, fixing in replacement, testing and commissioning air break isolating switch tripple pole mechanically operated with vertical isolation, 12 insulators mounted on steel frame with operating mechanism worked from ground level and including operating rod of 25 mm dia medium grade GI pipe and locking arrangement of capacity 400 Amps 11 KV with drop out fuse set including making all incoming/outgoing connection of HT cable and ocerhead conductor using new leads and nuts, bolts etc and painting of steel work with 2 coats of aluminium paint over a coat of red oxide primer complete all as specefied and directed by Engr-in-charge.Make: Jaipuria/Pactil/ Alstom
Opening, maintenance and general servicing of servo voltage stabilizer of capacity 50 KVA and 100 KVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specefied and directed by Engr-in-charge. Note: a) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. b) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item c) All T & P and transportaion arrangement are deemed to be included in the rates quoted.
Supply only following parts suitable for three phase servo voltage stabilizer upto 100KVA capacity as per existing make or as recommanded by original stabilizer manufacturer complete all as specified and directed.
Volot Meter (Digital/Analog)
Ampere meter with CT (Digital/analog)
Micro Processor based control card for each phase
Servo synchronizing motor single phase AC 230 Volts, 3 Kg torque
RC Net work for 3 Kg torque servo motor
Carbon Brush of any capacity
Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) LT feeder pillar box (KIOSK) out door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, IP-65 dust and vermin proof, made of 2 mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 40x40x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following :- Incoming (a) MCCB 100 amps, 4 pole, 25 KA with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 1 Nos. Make: L&T , Legrand, Scheineider, ABB, Havells, C&S Outgoing (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 160 Amp, 4 pole, not less than 45 cm long mounted on insulators for incomming supply 01 No. ( b) 15/16 Amp Switch Socket combine - 06 Nos Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands. (v) cable glands for incoming and out going suitable cables is including rate quated by vendover (vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables
Supply and Fixing LT Junction box cubical type of size 60x40x30 cm, 415 volts for outdoor use made out of CRCA Sheet 3.15 mm thick powder coated, machine passed front opening with sigal door with privision of rubber beading and locking system including aluminium bus bar 4 srip of size 30mm wide and 6mm thick with provision of hole on bus bar fixing of cable mounted on PVC/ epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/Outgoing cables and testing complete all as directed by Engr-in-charge.
M&L Preparing surface of servo Voltage Stabilizer complete body and applying painting two coats of suoerior quality synthetic enamel paint using spray gun including sticker work and writing of MES/SM Nos etc complete all as specified and directed by Engineer-in-charge.
Supply and fix cable tray stainless steel of size 200mmX 50mmX6mm for dressing hanging cable such that structural system should be support insulated electrical cables for power distribution, control, and communication all as directed.
PROACH ASSOCIATES BUILDERS & ENGINEERS (BID ID -3355625)
MOHAN LAL AND SONS (BID ID -3346683)
DAVINDER SINGH (BID ID -3347180)
slathia construction works (BID ID -3347123)
PREM NATH KHAJURIA AND SONS (BID ID -3345456)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .