Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 7TH FLOOR DN 12 SECTOR V SALT LAKE CITY KOLKATA 700091 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700091 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.1 L+₹63,600 (6.69%)Rejected-Finance 184 187 TEMPLESTEPS BLOCK ANNASALAI LITTLEMOUNT CHENNAI CHENNAI TAMIL NADU 600015 | CHENNAI | TAMIL NADU | 600015 | L2 | Rejected-Finance 2nd Lowest Bidder | |
| 3 | L3₹10.5 L+₹1 L (10.5%)Rejected-Finance 327 328 III FLOOR INDRAPRASTH TOWER INDORE | INDORE | INDORE | MADHYA PRADESH | L3 | Rejected-Finance 3rd Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
5 Feb 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Office of SE,SWEC,PWD, MIDNAPORE
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.D) South-Western Electrical Circle PWD Compound, Midnapore, Paschim Medinipur
Construction of Central Library Buildings in the main campus of Bankura University---SITC of 8 Passengers lift at Central Library building.
2021_WBPWD_316980_1
WBPWD/SE/SWEC/NIQ37/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹30,000
Office of SE / SWEC, PWD, Midnapore
20 Jul 2022
21 Jan 2021
8 Feb 2021
21 Jan 2021
5 Feb 2021
28 Jan 2021
27 Jan 2021
120 days
Amount
Supply , Installation , Testing & Commissioning of 8 (Eight) Passengers lift as per following specification :- Make - OTIS / KONE / SCHINDLER
TYPE : Passenger CAPACITY (Kgs) : 8 PERSONS 544 KGS. SPEED (MPS) : 1 MPS. RISE ( m) : Ground floor to 3rd floor about 4.05 m per floor STOPS : 4 Stops & 4 opening With (all opening on the same side) CONTROLLER TYPE : Microprocessor based DRIVE : VVVF (Closed Loop) Drive POWER SUPPLY : 400/415 Volts (3Phase AC) OPRATION : Full collective operation CAR GROUP : One car (simplex) MACHINE : PM Gearless (Located above shaft) TRACTION MEDIA : stainless steel rope of required size / Flat Coated Steel Belt
CAR FINISH : Rear Mid Panel = Staineless Steel hairline finish Rear Corner Panels = Stainless Steel hairline finish Side Panels = Stainless steel hairline finish Front Panels = Stainless steel hairline finish FLASE CEILING TYPE : Standard FLASE CEILING FINISH : Stainless steel hairline finish VENTILLATION : Cross flow fan HAND RAILS : Stainless Steel hairline finish Handrails on rear car panels FLOORING : Granite Slab CAR DOOR FINISH : Stainless steel hairline finish LANDING DOORS FINISH : Stainless steel hairline finish FIRE RATED DOORS : Fire rating -60mins MACHINE ROOM : Machine Room less design(MRL) under lintel height of landing doors : 2180mm Pit (below bottom floor level) : 1650mm Over Head : 4500mm HOISTWAY DIMENSIONS (W x D - mm) : 1850 mm W x 1750 mm D CAR DIMENSION (W x D x H - mm) : 1100 mm W x1300 mm D x 2300 mm D CAR HOISTWAY DOOR TYPE : Centrial opening (CO) doors
Car Entrance : Fully automatic stainless steel doors in stainless steel hairline finish with centre opening without vision panel DOOR OPENING (W x H - mm) : 800 mm W x 2000 mm H DOOR OPERATOR : DC / AC Door Operator COP : Gien / braile Buttons in Stainless Steel hairline finish CAR POSITION INDICATOR : Dot matrix (RED LED) Scrolling Display /Backlit LCD HALL FIXTURES : Braile Micropush button with dot matrix display HALL FIXTURE FACE PLATE : Stainless steel hairline finish HALL BUTTON ARRANGEMENT : Hall Button with UP/DN at intermediate floor and only UP/DN at lowest / upper most floor.
STANDARD FEATURES : Anti- nuisance Car Call Protection, Independent Service (for Duplex only), Overload Device , Nudging, Emergency Firemen's Service, Emergancy Car Light Unit, Infrared Curtain Door Protection , Door time Protection, Emergencey Alarm Button, Extra Door time of Lobby & Parking , door Open/Close Button, Manual Rescue Operation , Auto fan Cut Off, steel rope drive. SAFETY FEATURES: a) Over Speed Protection b) Single Phase Protection c) Over Load Protection d) Phase faliure Protection e) Terminal Limit Switch f) Emergency Stop Switch g) Inter Locking Switch h) Reverse Phase Protection i) Delocking arrangement from Loading OPTIONS REQUIRED : Automatic Rescue operation, Voice Synthesizer, intercom.
Otis Elevator Company(India)Limited
KONE ELEVATOR INDIA PRIVATE LIMITED
technical_601222.pdf
PDF • 0.22 MB
techsummary_601222.pdf
PDF • 0.22 MB
finance_601222.pdf
PDF • 0.22 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_601222.pdf
PDF • 0.23 MB
docaoc37.pdf
PDF • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .