Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 CrAccepted-AOC | ₹1.6 Cr | 1 | Accepted-AOC Qualified |
| 2 | 1₹1.6 CrRejected-AOC BISHNU RABHA PATH H NO 30 HATIGAON GUWAHAT | ₹1.6 Cr | 1 | Rejected-AOC Qualified |
| 3 | 2₹1.8 Cr+₹20.7 L (13.3%)Rejected-AOC | ₹1.8 Cr+₹20.7 L (13.3%) | 2 | Rejected-AOC Not Qualified |
Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
20 Nov 2023, 2:00 pmClosed
Chief Engineer, PWD (Roads), Assam
O/o the Chief Engineer, PWD (Roads), Assam
Improvement of Basisthapur By-lane-1(Gautam Upa Path and Damodar Upa Path) and construction of RCC Load Bearing Drain at Survey under Mukhya Mantrir Nagoriya Paki Path Nirman Achoni (MMNPPNA) for the year 2023-24
2023_PWD_33338_15
CE/CW/20/23-24-Nagariya-Lot-2
Open Tender
Civil Works – Roads
Item Rate
120 days
Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,500
₹3.5 L
Yes
7 Mar 2024
31 Oct 2023
20 Nov 2023
31 Oct 2023
20 Nov 2023
31 Oct 2023
31 Oct 2023 - 20 Nov 2023
Amount
Granular Sub -base with Well Graded Material (Table 400.1) (A) By Mix in place method, Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. ii ) For Grading II Material
WBM Grading 3 Using stone sceening Type- B 11.2mm for Gr. III, Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means.
Interlocking concrete block pavement Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504. A) Including Edge block/ Edge restraints
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material,disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 metres), RCC
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material., ordinary soil, upto 3.00 m depth
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.), PCC Grade M-15
Supplying, fitting and placing TMT( Fe-500 D) bar reinforcement in sub-structure complete as per drawing and technical specifications Clause,. (a) With other make ISI marked TMT rebar Secondary Producer
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 With Crushed stone (IV) RCC Grade 20 (i) For height upto 5 m
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (i) Sandy materials
MS ANU ENTERPRISE
Tapash Paul
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .