| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | ₹15.3 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹17.3 L+₹2.0 L (13.3%)Rejected-Finance | ₹17.3 L+₹2.0 L (13.3%) | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹19.2 L+₹3.9 L (25.8%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | ₹19.2 L+₹3.9 L (25.8%) | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹19.4 L+₹4.1 L (26.8%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹19.4 L+₹4.1 L (26.8%) | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹20.8 L+₹5.5 L (36.0%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | ₹20.8 L+₹5.5 L (36.0%) | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹22.1 L
EMD Value
₹44,200
Closing Date
3 Jan 2024, 6:00 pmClosed
Garrison Engineer (I) (CG) Goa
Garrison Engineer (I) (CG) Goa HQ Coast Guard DHQ-11 Chicolna PO- Bogmalo Goa 403806
PROVISION OF HT RMU PANEL FOR RESIDENTIAL AREA AT TRV CHICOLNA GOA UNDER GE(I)(CG) GOA
2023_MES_631058_1
8443/GOA/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
TRV CHICOLNA GOA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (I) (CG) Goa
₹44,200
Yes
16 Feb 2024
4 Dec 2023
11 Jan 2024
4 Dec 2023
3 Jan 2024
19 Dec 2023
4 Dec 2023 - 11 Dec 2023
Amount
Supplying, installation, testing and commissioning of 11 KV, 630 Amps 21kA/3-sec, outdoor (IP54 type), RMU (Ring Main Unit) 4 operated Fixed-Type spring-charging VCB and 03 Nos 630 Amp Fixed copper bus bars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Magnetic Grade) tank with minimum thickness 2mm, IP 67 Degree of Protection, into classified 21kA/1sec as per IEC62271-200, The enclosure shall have pad lockable with anti hinges, fully covering the front facia and cable boxes to ensure fail having short circuit capacity 54 4-way comprising of 01 Nos manually Fixed-Type spring-charging VCBs, internal-anti-theft fail-safe anti-theft protection.
a) Repturing capacity 350MVA and 630A - 1 No (I/C)
b) Repturing capacity 350MVA and 400A - 3 Nos (O/G)
Supply, laying in trenches/ duct of HT under groundXLPE insulated screened PVC bedded galvanized steelstrip or wire armoured, electric power cable ( heavy duty) with aluminium conductor suitable for 11 KV grade ( Earthed) cross sectional area 95 sqmm , 3 core complete all as specified and directed.
M & L Cable jointing kit for 11 KV (earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitablefor 3 core 11 KV UG aluminium conductor armoured XLPE cable of size 50 to 95 sq mm 3 core complete all as specified and directed.
M & L Cable jointing kit for 11 KV (earth) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core 11 KV UG aluminium conductor armoured XLPE cable of size 50 to 95 sq mm 3 core complete all as specified and directed.
Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wide and getting out in soft disintegrated rock/ laterite rock complete all as specified and directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply/ Lay dry river sand/ M sand in trenches for cable protection complete all as specified and directed. [Note :- Punned thickness only will be measured & Paid]
Supply and laying un re-inforced precast concrete cable cover, class HPV, type-I, flat size 300 mmx180 mmx40 mm in trenches over and across the cable complete all as specified
M & L Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, using galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including required excavation and testing on including taking down old unserviceable materials complete all as specified and directed.
S and G Constructions
NAVREET CONSTRUCTION
Sagar Electricals
HUMERS INFRATECH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .