Loading…
Loading…
Tender Value
₹2.2 L
EMD Value
₹4,460
Closing Date
22 Jun 2026, 5:00 pm5d left
Superintending Engineer
Municipal Corporation Patiala
S/E OF STREET LIGHT AT IKTA COLONY PARK (W NO.-13) Est Cost Rs. 2.23 lacs dt 22/23.06.2026
2026_DLG_169990_1
MCP/2026/106-108/09
Open Tender
Electrical Works
30 days
Patiala
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹4,460
Yes
12 Jun 2026
12 Jun 2026
23 Jun 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:
Supply and erection of Double Walled Corrugated
(DWC) HDPE pipe to be laid 1mtr. below ground level
including excavation placing the pipe in position and back
filling with excavated soil etc. of the required size:-
Double Walled Corrugated HDPE Pipe 50/ 38mm (Outer/ Inner dia.) | 150 | mtr | 133.79 | ₹20,068.5 |
| 2 | XLPE INSULATED LT CABLES: XLPE INSULATED UN-ARMOURED CABLES (LOOSE): Supply, laying and erection of
aluminium conductor XLPE insulated PVC sheathed
Un-armoured and served cable 1100 volts grade as per
IS 7098 (Part-1)1988 to be laid loose in the existing
trench or pipe as per PWD General Specifications: Overall size 10sq.mm (3Core) Un-armoured (Loose) | 190 | mtr | 136.11 | ₹25,860.9 |
| 10 | PVC INSULATED FR COPPER CONDUCTOR CABLES:
Supply and erection of PVC insulated FR single core
Unsheathed copper conductor cable (ISI marked) suitable
upto 1100 volts grade confirm to IS:694/1990 left bare in
pipe or casing of suitable size complete in all respect as
desired by the Engineer-in-charge:- Overall size 1.5sq.mm (Un-sheathed) | 200 | mtr | 30.34 | ₹6,068 |
| 11 | 3-STEPPED STEEL TUBULAR POLE:
Supply and erection of 3-Stepped steel tubular
swaged and welded pole (410-SP-Mpa) of suitable
length confirming to IS: 2713- (PART-II)-1980 (Steel
tubes confirming to IS: 1161-1979, UTS 42 kgf/
Sq.mm) to fix up to a required planting depth below ground
level in a hole of excavation about 45 cm dia. and suitable
depth to fill up to 15 cm below G/L with 1:2:4 cement
concrete mixture including painting of pole with two coats
of approved aluminium paint as required:-
Overall length 8 metre, length of sections 4.5 metre,
1.75 metre and 1.75 metre (Bottom, Middle and Top
respectively), Outer dia and thickness of sections
139.7mm x 4.5mm, 114.3mm x 3.65mm and 88.9mm x
3.25mm (Bottom, Middle and Top respectively) with
approximate weight 101 kg. (410 SP-13) base Plate weight
7.5 kg. of size 12mm thick about 30 cm dia | 6 | no | 13,694.44 | ₹82,166.64 |
| 12 | LAYING OF UNDER GROUND CABLES,
DISMANTALLING & ERECTION OF POLES AND CEMENT CONCRETE MUFFS
Making of Cement Concrete muff of suitable size
and length with 1:2:4 cement concrete mixture. The muff is
to be made around the steel tubular pole sufficient to
completely flush a SMC Junction Box (Glass Fibre
reinforced polyester sheet moulding compound)
confirming to IS:14772, inner dimensions 250mm x 200mm
x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos.
terminals & 1No. Single pole MCB of required capacity fixed
on din bar (Din Bar Provision for 2Nos. MCBs). The SMC
Junction Box is to be fixed with the pole by a MS flat
clamp of size 20mm x 2mm thick. PVC pipe 40mm dia.
(2No.x0.60m) should be provided for incoming and
outgoing cables. The outer surface of the muff shall be
finished with pure cement & two coats of white snowcem
complete in all respect as approved and desired by the
Engineer In-Charge at site: Cement Concrete Muff of Overall Size 450mm dia.,
80cm Long with making an extra collar (If pole installed in
Centre verge/ Footpath) will be provided with 1:2:4
cement Sand & concrete mixture around the Steel
tubular pole. The size of collar (height is 40cm & dia. is 45cm
including pole dia i.e. 168.3mm) | 6 | no | 2,090.14 | ₹12,540.84 |
| 13 | GI PIPE POLES & BRACKETS:
SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE:
Supply and erection of G.I. Pipe 50mm dia. (Medium)
Single/ Double/ Triple arm bracket of suitable length
welded with MS canopy 80mm inner dia., outer dia 89.5mm
(Medium), 450mm long suitable for 3 stepped steel
tubular swaged and welded pole with top outer section
dia. 76.1mm. The MS canopy should have 3no. holes for
fixing the bracket at the top end of the pole with the help
of 3Nos. ½" x 1½" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of
89.5mm dia. for covering the top end of the canopy. The MS
canopy and GI bracket should be welded at tentative angle
105º (105 degree) inclination with MS sheet 5mm thick
triangular in shape having dimensions 225/300/375mm
x 150mm x 5mm thick (225mm for 1.5m, 300mm for
2m & 375mm for 2.5m long bracket) with two coats of an
approved aluminium paint as desired by Engineer-in-charge at site: Double Arm Bracket 1.5 metre Long for Steel Tubular
Pole (7 to 8m) | 6 | no | 3,675.87 | ₹22,055.22 |
| 14 | GALVANIZED IRON PIPES AND G.I. EARTHING
Supply & erection of G.I. pipe (A-Class) as per IS:1239
(Part-I) 2004 including sockets, bends, inspection
boxes, Steel hooks, GI saddle clamps and other petty
materials etc., where necessary including painting
as per PWD General Specifications:- Earthing earth rod 20
mm dia for providing earth connections upto line earth
with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered
at one end and flatted on other end. The hole size
10mm dia shall be drilled on the flatened side for
facilitating connection withG.I. wire and thimble etc. The
rod shall be erected in ground upto complete length
vertically:- GI Earth rod 20 mm dia., 3 mtr. Long | 6 | no | 1,274.74 | ₹7,648.44 |
| 15 | Supply and Erection of LED Street Light 70 watt (including
LED driver) with pressure die cast aluminium housing with
control gear ( with IP 65/ IP 66 protection), CRI Minimum
70, CCT >5700K, toughened glass fitting, LED fixture glass fitting, LED fixture
minimum 120 lumens per watt and operating voltage
between 140 to 270 volt, THD <10% ingress protection (as per BIS standards) , surge
protection 10kv and above (as per (IS/IEC standards)
wattage of each LED High power LED of 1 watt to 5 watt with mandatory modular
lenses, input AC frequency 50 Hz ± 3 % 5 year warranty
including their drivers complete along with erection
of the same with connections, testing etc. complete in all
respects as approved and desired by the
Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech.
Advisor to CM Punjab vide Letter no AT-2021/GL
1410-1422 Dated 06/05/2021. Dated
06/05/2021. Besides this the lighting fixture manufactures
should have in house NABL accredited labortary. Make As
desired by Engineer in charge. | 12 | no | 3,924 | ₹47,088 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
BOQ_346011.xls
BOQ • 0.32 MB
Generaltenderconditions.pdf
Tender Documents • 4.57 MB
COPYSOPnotification.pdf
Tender Documents • 0.21 MB
Etenderlist.pdf
Tender Documents • 1.09 MB
Download all tender documents and submit your bid