Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 LAccepted-AOC | ₹25.8 L Quoted ₹26.8 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹27.9 LRejected-Finance | ₹27.9 L | L2 | Rejected-Finance Being L2 bidder |
| 3 | L3₹28.2 LRejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | ₹28.2 L | L3 | Rejected-Finance Being L3 bidder |
| 4 | L4₹33.3 LRejected-Finance H NO 861 SECTOR 1 4 HOUSING BOARD COLONY NEAR POLY CLINIC HISAR HARYANA | HISAR | HARYANA | 125001 | ₹33.3 L | L4 | Rejected-Finance Being L4 bidder |
| 5 | L5₹48.9 LRejected-Finance | ₹48.9 L | L5 | Rejected-Finance Being L5 bidder |
| Rank | Bidder | Total Amount |
|---|---|---|
| L3 | M/s Devendera construction Bid ID 3493714 | ₹28,17,565 |
| L1 | KUNAL ENTERPRISES Bid ID 3494377 | ₹26,77,777 |
| L5 | laxmi enterprises Bid ID 3494200 | ₹48,87,009 |
| L4 | Natwadia Electrical Company Bid ID 3500694 | ₹33,29,120 |
| L2 | FOUJI ELECTRIC WORKS Bid ID 3500934 | ₹27,93,555.55 |
| Sl No | Description | Qty | Unit | M/s Devendera construction L3 | KUNAL ENTERPRISES L1 | laxmi enterprises L5 | Natwadia Electrical Company L4 | FOUJI ELECTRIC WORKS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | To Attend the complaint of DG sets of 7.5 KVA to 500 KVA capacities installed at various locations of Mil Stn Hisar/EBS/BHOJRAJ. Checking and testing complete DG set (Including engine, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/replacements required to be carried out in different parts of the DG sets. Carrying out general servicing and minor repairs and/or replacements, including following jobs whichever is required to make DG Set functional as directed by Engr-in-charge :- (i) Checking and cleaning of diesel filters & oil filters and making a list of filters required to be replaced (ii) Checking of engine oil level and intimating the quantity of oil required for topping, if any. (iii) Checking, cleaning and servicing including oiling & greasing of engine and making list of repairs / replacements required, if any. (iv) Checking of alternator battery including tightening of nuts, bolts, lugs and the like. Also making a list of repairs / replacements required, if any.(v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs / replacements required, if any. (vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop. (vii) Checking of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/replacements required, if any. (ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors, meters, etc. and making list of repairs / replacements required, if any. (x) Tightening / replacement of nuts, bolts, washers and the like of DG set all as directed. (xi) Checking for diesel leakage from any point and rectify if can be rectified by minor repairs / replacements. Else make list of repairs / replacements required, if any. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements required, if any. (xiii) Checking of exhaust / silencer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. Else make a list of repairs / replacements required, if any. | 80 | Nos | 1,000 ₹80,000 | 577 ₹46,160 | 500 ₹40,000 | 600 ₹48,000 | 500 ₹40,000 |
| 1.01(xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. (xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xvii)(a). Checking output of alternator and adjusting the same to specified values, in case of brush type (b) cleaning & servicing of the alternator, minor repairs & replacements and making list of alternators requiring complete overhauling (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any (xix) Checking, cleaning & servicing of air filter elements and making a list of replacements required, if any (xx) Oiling, greasing and checking for proper functioning of DG set. Note - I. Rates quoted by the tenderer are also deemed to include the cost of S&F in replacement of minors parts like nuts, bolts, washers, lugs, etc., supply and applying oil & greasing and minor repairs to DG set. II. The work under this item is to be carried out as complaint received and as directed by the Engineer in charge. III. List of repairs / replacements prepared by the contractor shall be submitted to the Engineer in charge for verification. IV. The all mentioned above maintenance work carried out by contractor. (V) Contractor Shall be bound to depute a qualified Mechanic for the above work with in 12 Hrs of intimation/ failure , the complete deemed cost should be included in above quoted rate by contractor. | ||||||||
| 2.00 | M&L for full servicing of DG Sets of capacity 7.5KVA to 63KVA complete as per following :-(i)Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket .(ii)S& F in replacement lubricant oil filter element .(iii)S&F in replacement fuel filter element.(iv)S&F bypass filter element.(v)checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required . (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirement.(viii) Check all electrical conditions(ix)Check pollution level(X) Change water separator and radiator cleaning with chemical.(x) Change hydraulic governor oil,Change aneroid oil, check aneroid adjustment, Replace aneroid breather.(xi) Clean radiator externally, Check fan hub/Idler and water pump/idler.(xii)Inspect units, Replace as required (Alternator/Generator, Starter etc), Check air cleaner if required, Evacuator valves change if required. Note: (i) Cost of fuel filter element, Oil filter element, bypass filter element, governor oil, aneroid oil, aneroid breather and greasing will be included in the quoted rate. (ii) Cost of Engine oil, Coolent, air cleaner, alternator and starter will be paid separately under appropriate head. (iii) Service period of DG Set must be either 6 Months or after manufacture standard Hr Running. | 34 | Each Job | 4,000 ₹1,36,000 | 2,277 ₹77,418 | 1,500 ₹51,000 | 2,000 ₹68,000 | 1,500 ₹51,000 |
| 2.01 | Description all as per item No 2.00 but DG Set Cap 82 KVA to 225 KVA complete all as specified and directed. | 30 | Each Job | 8,000 ₹2,40,000 | 2,477 ₹74,310 | 1,500 ₹45,000 | 2,500 ₹75,000 | 2,555 ₹76,650 |
| 2.02 | Description all as per item No 2.00 but DG Set DG Set Cap 250 to 500 KVA complete all as specified and directed. | 8 | Each Job | 9,000 ₹72,000 | 4,777 ₹38,216 | 8,000 ₹64,000 | 3,000 ₹24,000 | 6,500 ₹52,000 |
| 3.00 | Replacement / Filling up/ Top up of Engine Oil (20 W 40) suitable for DG sets complete all as specified and directed. | 1,000 | Litres | 240 ₹2,40,000 | 187 ₹1,87,000 | 290 ₹2,90,000 | 200 ₹2,00,000 | 200 ₹2,00,000 |
| 4.00 | Replacement / Filling up/ Top up of Pre mix Coolant suitable for DG Set complete all as specified and directed. | 600 | Litres | 150 ₹90,000 | 117 ₹70,200 | 170 ₹1,02,000 | 200 ₹1,20,000 | 100 ₹60,000 |
| 5.00 | Supply & Fix distiled water suitable for battery of DG Set all as specified and as directed. | 200 | Litres | 20 ₹4,000 | 17 ₹3,400 | 30 ₹6,000 | 11 ₹2,200 | 10 ₹2,000 |
| 6.00 | S&F in replacement of air cleaner filter for DG Set capacity 250 KVA to 500 KVA complete all as specified | 4 | Each | 800 ₹3,200 | 7,777 ₹31,108 | 4,500 ₹18,000 | 2,200 ₹8,800 | 2,500 ₹10,000 |
| 7.00 | S&F in replacement of air cleaner filter for DG Set capacity 82 KVA to 225 KVA complete all as specified | 15 | Each | 500 ₹7,500 | 2,777 ₹41,655 | 4,500 ₹67,500 | 1,600 ₹24,000 | 1,250 ₹18,750 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Dec 2025, 6:00 pmClosed
GE (W)
GE (W) HISAR HISAR MIL STN
CA NO GE(W)/HSR-37/2025-26 COMPREHENSIVE REPAIR/MAINT OF DG SETS AND STREET LIGHTS INCLUDING ALLIED WORKS AT HISAR/BHOJRAJ/EBS MIL STN UNDER GE (W) HISAR
2025_MES_740479_1
CA NO. GE(W)/HSR-37/2025-26
Open Tender
Electrical and Maintenance Works
270 days
HISAR
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (W) HISAR
₹90,000
GE (W) HISAR
12 Feb 2026
19 Nov 2025
19 Dec 2025
19 Nov 2025
17 Dec 2025
3 Dec 2025
20 Nov 2025 - 27 Nov 2025
27 Nov 2025
Amount
To Attend the complaint of DG sets of 7.5 KVA to 500 KVA capacities installed at various locations of Mil Stn Hisar/EBS/BHOJRAJ. Checking and testing complete DG set (Including engine, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/replacements required to be carried out in different parts of the DG sets. Carrying out general servicing and minor repairs and/or replacements, including following jobs whichever is required to make DG Set functional as directed by Engr-in-charge :- (i) Checking and cleaning of diesel filters & oil filters and making a list of filters required to be replaced (ii) Checking of engine oil level and intimating the quantity of oil required for topping, if any. (iii) Checking, cleaning and servicing including oiling & greasing of engine and making list of repairs / replacements required, if any. (iv) Checking of alternator battery including tightening of nuts, bolts, lugs and the like. Also making a list of repairs / replacements required, if any.(v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs / replacements required, if any. (vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop. (vii) Checking of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/replacements required, if any. (ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors, meters, etc. and making list of repairs / replacements required, if any. (x) Tightening / replacement of nuts, bolts, washers and the like of DG set all as directed. (xi) Checking for diesel leakage from any point and rectify if can be rectified by minor repairs / replacements. Else make list of repairs / replacements required, if any. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements required, if any. (xiii) Checking of exhaust / silencer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. Else make a list of repairs / replacements required, if any.
(xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. (xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xvii)(a). Checking output of alternator and adjusting the same to specified values, in case of brush type (b) cleaning & servicing of the alternator, minor repairs & replacements and making list of alternators requiring complete overhauling (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any (xix) Checking, cleaning & servicing of air filter elements and making a list of replacements required, if any (xx) Oiling, greasing and checking for proper functioning of DG set. Note - I. Rates quoted by the tenderer are also deemed to include the cost of S&F in replacement of minors parts like nuts, bolts, washers, lugs, etc., supply and applying oil & greasing and minor repairs to DG set. II. The work under this item is to be carried out as complaint received and as directed by the Engineer in charge. III. List of repairs / replacements prepared by the contractor shall be submitted to the Engineer in charge for verification. IV. The all mentioned above maintenance work carried out by contractor. (V) Contractor Shall be bound to depute a qualified Mechanic for the above work with in 12 Hrs of intimation/ failure , the complete deemed cost should be included in above quoted rate by contractor.
M&L for full servicing of DG Sets of capacity 7.5KVA to 63KVA complete as per following :-(i)Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket .(ii)S& F in replacement lubricant oil filter element .(iii)S&F in replacement fuel filter element.(iv)S&F bypass filter element.(v)checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required . (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirement.(viii) Check all electrical conditions(ix)Check pollution level(X) Change water separator and radiator cleaning with chemical.(x) Change hydraulic governor oil,Change aneroid oil, check aneroid adjustment, Replace aneroid breather.(xi) Clean radiator externally, Check fan hub/Idler and water pump/idler.(xii)Inspect units, Replace as required (Alternator/Generator, Starter etc), Check air cleaner if required, Evacuator valves change if required. Note: (i) Cost of fuel filter element, Oil filter element, bypass filter element, governor oil, aneroid oil, aneroid breather and greasing will be included in the quoted rate. (ii) Cost of Engine oil, Coolent, air cleaner, alternator and starter will be paid separately under appropriate head. (iii) Service period of DG Set must be either 6 Months or after manufacture standard Hr Running.
Description all as per item No 2.00 but DG Set Cap 82 KVA to 225 KVA complete all as specified and directed.
Description all as per item No 2.00 but DG Set DG Set Cap 250 to 500 KVA complete all as specified and directed.
Replacement / Filling up/ Top up of Engine Oil (20 W 40) suitable for DG sets complete all as specified and directed.
Replacement / Filling up/ Top up of Pre mix Coolant suitable for DG Set complete all as specified and directed.
Supply & Fix distiled water suitable for battery of DG Set all as specified and as directed.
S&F in replacement of air cleaner filter for DG Set capacity 250 KVA to 500 KVA complete all as specified
S&F in replacement of air cleaner filter for DG Set capacity 82 KVA to 225 KVA complete all as specified
S&F in replacement of air cleaner filter for DG Set capacity 7 KVA to 63 KVA complete all as specified
Supply & Fix in replacement of battery lugs of suitable capacity all as directed and specified.
S & F in replacement of Diesel Pipe Filter to Pump for DG Set complete all as specified and directed.
S & F in replacement of Diesel Pipe Filter to Tank for DG Set complete all as specified and directed.
S&F in replacement of Battery Copper cable Red with plug of size 35 sqmm complete all as specified and directed.
S&F in replacement of Battery Copper cable Black with plug of size 35 sqmm complete all as specified and directed.
M& L for opening the head of DG Set and replacement of gaskit for remove leakage of water and oil from the head of DG set complete all as specified and directed.
S&F in replacement of Hose Pipe Set suitable for following capacity of DG Sets & complete all as specified and directed.
Up to 63 KVA DG Set
82 KVA to 225 KVA DG Set
250 KVA to 500 DG Set
Servicing of radiator assembly DG Sets 12.5 KVA to 63 KVA and replacement of minor parts to make it operational after repair, welding, brazing, leak testing including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified and directed.
Servicing of radiator assembly DG Sets 100 KVA to 200 KVA and replacement of minor parts to make it operational after repair, welding, brazing,leak testing including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified and directed.
Servicing of radiator assembly DG Sets 250 KVA to 500 KVA and replacement of minor parts to make it operational after repair, welding, brazing, leak testing including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified and directed.
S & F in replacement "V" belt for Radiator fan of Make : Fanner ,for following DG Set:-
Upto 63 KVA
82 to 225 KVA
250 to 500 KVA
S & F in replacement Radiator up to 100 KVA DG Set/diesel Pump 76 BHP complete all as specified and directed.
M&L for repairing/decarburizing manifolds exhaust system and connected items of exhaust muffler/silencer including necessary nuts, bolts and washers necessary welding of any capacity of DG Set etc with necessary masonry works as required complete all as specified and directed. Note :- Any building/ civil work for support of manifolds exhaust system will be included in this item and nothing shall be paid extra on this account.
Taking out the charging alternator of DG Set of following capacity and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable , bushes & minor parts & reinstalling the same after testing complete all as specified and directed.
DG set of capacity upto 7 to 63 KVA
DG set of capacity 82 to 225 KVA
DG set of capacity 250 to 500 KVA
Removing, transporting to workshop, Repairing & Servicing of self starter of DG set ranging from 7.5 KVA to 500 KVA including winding and replacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc., reassembling and testing complete all as specified and directed.
S & F in replacement Solenoid Switch for 250 to 500 KVA DG set and testing complete for proper functioning complete all as specified and directed.
S & F in replacement Solenoid Switch for 82 to 225 KVA DG set and testing complete for proper functioning complete all as specified and directed.
S & F in replacement Solenoid Switch for 12.5 to 63 KVA DG set and testing complete for proper functioning complete all as specified and directed.
S&F in replacement of Bentex wheel complete suitable for self starter complete all as specified and directed.
M & L for cleaning of Diesel Tank of DG Set "Tank Cleaned on Date………..complete all as specified and directed.
M&L for preparing old painted surface of DG sets (complete including engine, alternator, body & chases, Canopy) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and writting MES Number in block capital letters all as specified and directed. (Make of paint - Dupon / Asian / Berger / Nerolac)
Repair and maintenance of FIP including replacement of Plunzers, Governer kit with pin, Nozzles P type,Head ball guide kit, Head sheet (set of 12 piece) Rock rod,Rollar bearing,Oil seal, Piston pin,Gasket kit and sleeves complete as specified and directed. DG Set of following capacity
DG Set 7 to 63 KVA
DG Set 82 to 225 KVA
DG Set 250 to 500 KVA
M&L for calibration of fuel injector assembly of DG Set of 7 KVA to 63 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as specified and directed
M&L for calibration of fuel injector assembly of DG Set of 100 KVA to 225 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as specified and directed
M&L for calibration of fuel injector assembly of DG Set of 250 KVA to 500 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc, complete all as specified and directed
Descaling of water jacket of engine by using descaling solution with pressure circulation pump,leak testing, soldering, brazing, checking for leaks and recirculating with clear water complete all as specified and directed for following DG sets:-
up to 63 KVA DG Set
82 KVA to 225 KVA DG Set
250 KVA to 500 KVA DG Set
S&F Diesel pump with pipe assembly to make it fully fuctional and fixing it to its original position of DG Set in any capacity including replacement necessary element complete all as specified and directed.
S & F in replacement of Water pump Complete for 12.5 to 500 KVA DG Set complete all as specified and directed.
Opening the coupling of DG Set of capacity 250 to 500 KVA , dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed.
Opening the coupling of DG Set of capacity 82 to 225 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed.
Opening the coupling of DG Set of capacity 7 KVA to 63 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed.
S&F in replacement fan assembly along with hub suitable for DG Set of any cap complete all as specified and directed.
S & F in replacement of Anti vibration pad suitable for 25 to 500 KVA DG set complete all as specified and directed
S&F in replacement of Self Starter suitable for 12.5 to 125 KVA DG Set 12 Volt complete all as specified and directed. Make: Lucas/AutoLak
S&F in replacement of Self Starter suitable for 160 to 500 KVA DG Set 24 Volt complete all as specified and directed. Make: Lucas/AutoLak
Repair/Replacement wiring of DG Set from 12.5 to 63 KVA complete all as specified and directed.
Repair/Replacement wiring of DG Set 82 to 225 KVA complete all as specified and directed.
Repair/Replacement wiring of DG Set 250 to 500 KVA complete all as specified and directed.
S & F in replacement DG Set power controller up to 63 KVA DG Set complete all as specified and directed.
S & F in replacement DG Set power controller from 82 to 225 KVA DG Set complete all as specified and directed.
S & F in replacement DG Set power controller from 250 to 500 KVA DG Set complete all as specified and directed.
Supply only lead Acid battereies for DG set complete all as specified and directed for following capacity:-(Maintenance free battery of 2 years warrenty)
88 AH,12 Volt Make :- Exide/AMORON/PRESTOLITE
150 AH,12 Volt Make :- Exide/AMORON/PRESTOLITE
180 AH,12 Volt Make :- Exide/AMORON/PRESTOLITE
S & F in replacement of of Battery Charger of 6 Amps for 12 Volt Battery complete all as specified and directed.
S & F in replacement of Battery Charger of 6 Amps for 24 Volt Battery complete all as specified and directed.
M & L for complete checking of AMF panel,finding the fault,servicing complete including as per site and replacement of unserviceable spares and testing complete for manual & Auto operations complete all as specified and directed. Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule.
S & F in replacement Relay card for 63 to 500 KVA DG set and testing complete for proper functioning complete all as specified and directed.
Supply & Fix in replacement of single phase preventor complete all as specified and directed.
Supply & Fix in replacement of PLA relay complete all as specified and directed.
Supply & Fix in replacement 4 pole power Contractor MCX 32,160 Amp AC-1 ,415 V 2 NO +2NC complete all as specified and directed.
Supply & Fix in replacement 4 pole power Contractor MCX 43,400 A,415 V 2 NO +2NC complete all as specified and directed.
Supply & Fix in replacement 4 pole power Contractor TC1-D95 11 125 Amp, 415 volt complete all as specified and directed.
S & F in replacement of on load change over switch of capacity 200 Amp complete all as specified and directed.
S & F in replacement of on load change over switch of capacity 125 Amp complete all as specified and directed.
S & F Closing Coil for ACB operating on 220 to 240 Volt AC complete all as specified and directed.
S&F in replacement of AVR suitable for following capacity of DG Sets & complete all as directed.
up to 63 KVA DG Set
82 to 225 KVA DG Set
250 to 500 KVA DG Set
S & F in replacement MCCB's,415 Volts , 3 / 4 pole , with adjustable thermal & fixed magnetic settings having following capacities complete all as specified and directed :-.( Make:- Havells or equivalent in Schneider/ L& T/ABB/ Standard)
Upto 63 Amps 16 KA
100 Amps 25 KA
125 Amps 25 KA
160 Amps 36 KA
200 Amps 36 KA
250 Amps 36 KA
M & L for Earthing complete with galvanised iron steel plate electrode 600x600x6 mm burried directly in ground vertically in the pit of depth not less than 2.25 mtr below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides with mixture of charcoal and comman salt in alternate layers and electrode connected to galvanised iron strip 32x6mm by means of nuts bolts. The earth strip protected by 40 mm medium grade GI pipe upto test point complete all as shown in electrical plate NO 3 of SSR part I including 20 mm bore medium grade GI pipe for waterring incl PCC chamber on the top of the earth complete all as specified and directed. Note:- Quoted rate deemed to be inclusive of excavation and earthwork, PCC pit and cover.
Supply and fixing in replacement of door lock for DG Set canopy as per existing size and model complete all as specified and directed.
Supply and fixing in replacement of door Hinges for easy operation during door open and close complete all as specified and directed.
Checking of street light/flood/building fittings any type on pole/wall to find out defect on site and repairing to cable connection/loose connection /necessary cleaning the bowl/perpex cover whre provided and testing complete all as specified and directed. Note : (i) Spares of light fittings shall be measured & paid separately. (ii) The T&P Vehicles and necessry ladders etc will be arranged by the contractor and the cost of maint deemed to be included in the quoted rates (iii) Contractor shall be bound to depute 02 Nos qualified Electrician daily for the above work site (EBS, Bhojraj & Channibari), the complete deemed cost should be included in above quoted rate by contractor.
Supply only surge protector 10 kA with IP 65 protection, as per IS complete all as specified and directed.
Supply only driver suitable for 45 watt LED with IP 65 protection, as per IS complete all as specified and directed. Make- Crompton or Equivalent for Existing light driver.
Supply only driver suitable for 60 watt LED with IP 65 protection, as per IS complete all as specified and directed. Make- Crompton or Equivalent for Existing light driver make.
Labour for repair of street lights at MES store yard by electrician, cleaning, taking out unserviceable minor part, fixing of new part which required and testing for continous hours complete all as specified and directed. (i) Contractor shall be bound to depute 01 Nos qualified Electrician and 01 Nos labour for above work to repair the lights with in 24 Hrs , the complete deemed cost should be included in above quoted rate by contractor.
Supply and fixing energy efficient LED street light fitting of 45 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection complete all as specified and directed. Make- Polycab/ Havells/ Orient/ Crompton/ C & S
Supply and fixing energy efficient LED street light fitting of 60 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection complete all as specified and directed. Make- Polycab/ havells/ Orient/Crompton/ C & S
Supply and fixing energy efficient LED Flood light fitting of 90/100 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection complete all as specified and directed. Make- Polycab/Crompton/ C & S
Supply and fixing energy efficient LED Flood light fitting of 120 Watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection complete all as specified and directed. Make- Polycab/ Crompton/ C & S
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 10 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and as directed. Make- Polycab, Havells, KEI, Plaze or Equivalent
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 6 Sqmm flat twin core for connection for street light fitting with over head lines / service connection complete all as specified and as directed. Make- Polycab, Havells, KEI, Plaze or Equivalent
Supply and fixing in replacement PVC insulated stranded aluminium conductor cable sheathed 4 Sqmm flat Three Core for connection for street light fitting with over head lines / service connection complete all as specified and as directed. Make- Polycab, Havells, KEI, Plaze or Equivalent
Taking out old unserviceable under ground PVC/XLPE LT cable of any size from trenches/ wall/roof/road/pipe/pole including segregation of serviceable bricks for re-use complete all as specified and directed.
Supply and Laying LT XLPE cable of size 6 sqmm 2 core 1100 Volt grade aluminium conductor laid in trenches / fixed to wall / pole / laid in floor including necessary connection and suitable size of thimbling complete all as specified and as directed. Make- Havells, Gloster, KEI or equivalent. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured and paid separately under appropriate item of this schedule.
Description all as per Srl item No 84.00 above here-in-before but size of cable 10 Sqmm 2 Core complete all as specified and directed.
Description all as per Srl item No 84.00 above here-in-before but size of cable 10 Sqmm 4 Core complete all as specified and directed.
Description all as per Srl item No 84.00 above here-in-before but size of cable 16 Sqmm 4 Core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation, laying of cables or pipes (where provided) for protection of cable or fixing poles and stays and struts and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed.
Returning, filling in, approved soft/loose soil, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Supply and filling Local sand cushioning , with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable complete all as specified and directed.
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cablecomplete all as specified and directed.
Cleaning and preparation of old painted surface of street light PCC pole 9mtr long and making alternative black and white strips on pole with synthetic enamal paint (each strip 30 cm height) upto 1.5 mtr height from top of PCC foundation block complete all as specified and directed.
Material and Labour for earthing complete with galvanized iron of street or earth plate of size 60cmx60cmx6 mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth wire 4 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggredates complete including excavation and earth work, all as specified and show in plate No 3 of SRR-2009 Part-1, PCC pit shall be provided at least 50cm away from the earth pit and not just on earth pit including testing on completion.
Supply and fixing in replacement Sheet metal enclosure including 32 Amp MCB SPN with provision of duct for incoming and outgoing cable complete all as specified and directed.
Opening /disconnecting the electrical connection of defective/burnt out underground LT cable of any size any core from main switch/DB/junction box / LT panel/ L T O/H line etc. Taking out the required length of cable from existing loop, cutting the defective portion of cable ,providing required thimbles/ connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junctionbox/LT panel/O/H line etc complete all as specified and directed. Note:- (I) the cost of required earth work ie excavation,returning filling,relaying of sand/bricks and cost of drawing the required length from protection pipe ,breaking of required brick work/plaster/concrete and redoing the required cement work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account.(ii)Additional cable/ protection pipe required at site shall be measured and paid seperatly.
Supply and fixing LT cable junction box, dust and water proof made out of PVC non- metallic sheet FRP type, factory made, size of box 250x200x100mm deep with swiveling cover and locking clamp, consisting of aluminium bus bar strip 150mm x 30mm x 3mm, 4 Nos mounted on PVC insulator and provision of incoming/outgoing cables with grommets, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed. (Note :- MS clamps and nut bolts for fixing the box along pole shall be included in the quoted rate)
Supply and fix GI pipe bracket Up to 1.25 m long and made out of 32/40 mm dia light grade pipe including MS clamp of size 25 x 4 mm - 02 Nos for holding one bracket, nut and bolt with washer duly painted with aluminium paint over one coat of primer of suitable size complete all as specified and diected.
Supply and fixing in replacement of MCB, SP, 240Volt, 6 Amp 10KA complete all as specified and directed.
Supply and fixing of nature switch (using Infrared sensor technology) based automatic street light control panel. The panel should be suitable enough ro take single phase load of 5 to 8 KW with contactor incoming MCB & Outgoing MCB rating of 40 Amp and main load circuit wire(copper) of minimum 10 Sqmm. Nature switch operation should be based on Natural Light Lux Level. Required illuminance level for switching ON is< 60 Lux and for switching OFF > 10 Lux The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor along with suitable power contractor and incomming- outgoing MCBs should be enclosed in a pole/ wall mounted Rust proof, electric shock proof, termite proof and FR grade SME enclosure confirming to IP54. the circuit should also have provision for manual operation(i.e Sensor By-pass option) complete all as specified and directed. Make- Kakatiya energy system/Bajaj/Healer
Cutting/trimming of tree branches upto 1.50 mtr distance on both sides of LT over head lines including collection and removal from road complete all as specified and directed.
Supply and fixing in replacement LED post top lantern 25 Watt with aluminium die cast housing with frosted glass for glare free lighting complete all as specified and directed. Make- Havells, Polycab, Surya,Crompton etc
Taking out pump from its existing foundation by opening/ cutting nuts & bolts ,removing diesel pump, blocking the outlet & inlet system by proper plate, decoupling repair on site/ transportation of pump or part there of to contractors workshop and back to site , re- fixing , aligning , connecting inlet and outlet pipe after repair and replacement of following parts (as per requirement) suitable for centrifugal pump of capacity 76 BHP Diesel Pump of any make /model . Note:-(i) Replacement of Bearing, shaft sleeve, Gland Plate etc.shall be measured and paid for separately, rate for fixing spare shall deemed to be included in the quoted rate. (ii) Labour for opening up of pump and machinery work, Hydra if required, laith work of pump shaft if required, Nut Bolts, Oil Seal and other minor parts required to make the pump functional shall deemed to be included in the quoted rate.
Supply Only Gland plate for 76 BHP Pump complete all as specified and directed.
Supply Only Shaft sleeve for 76 BHP Pump complete all as specified and directed.
M&L in replacement of Bearing No. 51312 for 76 BHP Diesel Pump all as specified and directed. Make- SKF & NBC
M&L in replacement of Bearing No. 6410 for 76 BHP Diesel Pump complete all as specified and directed. Make- SKF & NBC
Replacement / Filling up/ Top up of Hydraulic oil N-68 for 76 BHP Diesel Pump suitable for Diesel Pump Coupling complete all as specified and directed. Make- castrol, Servo system
M&L in replacement of water temp meter for 76 BHP Diesel Pump of specified size complete all as specified and directed.
M&L in replacement of oil Pressure meter for 76 BHP Diesel Pump of specified size all as specified and directed.
M & L for disconnecting and Shifting of DG Set from DPH to existing Location By Hydra and make proper electric & earthing Connection all as specified and directed.
Supply of heavy duty Barrel rotary pump 95 mm with Suction, delivery pipe & filter on suction Pipe and all accessories complete all as specified and directed. Make - Eastman or Equivalent
FOUJI ELECTRIC WORKS (BID ID -3500934)
M/s Devendera construction (BID ID -3493714)
Natwadia Electrical Company (BID ID -3500694)
laxmi enterprises (BID ID -3494200)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Document
2.34 MB
BOQ
BOQ • 0.77 MB
Tender Documents
Tender Documents • 10.34 MB
Download all tender documents and submit your bid