Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹24.4 L+₹3.1 L (14.5%)Rejected-AOC FLAT NO 703 7TH FLOOR PARVATI ENCLAVE PLOT NO 180 SECTOR 2 TOLOJA PANCHANANDTAL TALOJA MAJKUR DISTT RAIGAD MAHARASHTRA 410208 | RAIGAD | MAHARASHTRA | 410208 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹25.0 L+₹3.7 L (17.5%)Rejected-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹25.9 L+₹4.6 L (21.4%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹26.4 L+₹5.0 L (23.7%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
27 Aug 2022, 6:00 pmClosed
GE NW BHANDUP
GE(NW) BAHDNUP, MUMBAI
REHABILITION OF DISTRESSED CONCRETE MEMBERS , STRUCTURAL REPAIRS,REPAIRS TO DAMAGED PORTION , FLOORING AND OTHER CONNECTED ITEMS INCL DAY TO DAY PETTY REPAIRS AT MO (MB) GHATKOPAR UNDER GE (NW) BHANDUP
2022_MES_543895_1
8223/B
Open Tender
Civil Works
Item Rate
270 days
GHATKOPAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(NW) BHANDUP
₹86,000
Yes
5 Dec 2022
6 Aug 2022
29 Aug 2022
6 Aug 2022
27 Aug 2022
20 Aug 2022
Amount
Dismantling of MS works of any description such as ,ladders,gates work,grating etc, including necessary straightening of bends complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided rainforced (rainforcement of cut as required to facilasite demolition etc) including removal of demolished materials out side of MD land complete all as specifed and directed.
S & F Mild steel work of framed brackets of Angles and ladder of watertanks and similar work flats cut to shape ,drilled and countersunk for screw, as in supports for stiffening of fencing, grating of open drain and including bending ,welding angles as necessary similar works confirming to Fe 290 or Gde-E165 and complete all as specifed and directed. .
M&L for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F for Pre- Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping ,drilling of screws/suitable length GI 'J' or 'L' hooks in roof complete all as specified and directed.
Material and labour for cracks with polymer based chemical Dr fixit cracks shrink free or equivalant for cracks not exc 10mm in width as per manufacturer instruction on wall surfaces on concrete or masonry incl scaffolding etc complete all as spd.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for carry out application of Bi -polar migratory corrosion inhibitor (make, M/S Krishna conchem (EPCO KP -100) / BASF ( master protect 8000 CI) on RCC surfaces , complete all as spd and directed .( Note: Mode of measurment superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for casting & repairing of excessively damaged distressedRCC members (exceeding 60mm in thikness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
S&F for 20mm dia curtain rods anodised aluminium alloy, power coated with fixing brackets, stops, rollers etc complete all as specified and directed
S&F in repair Health faucet with 1.5mtr tube & hook cat No BEA-40 complete all as specified and directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs brass Chromium plated wall mixer for mixing hot and cold water screwed down for iron pipe and fixed 15mm bore fancy type.
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers including CI cantilever bracket, connecting union etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm including supply and fixing bib tap CP with long body screwed for iron pipe complete all as specified and directed.
S&F in repairs chromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed.
S&F in repair brass chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, Cat No BA -01 of with and including chromium plated brass screws etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises etc out side MD land complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 7 to 8mm thick rectangular area of each tiles exc 0.06 sqm n exc 0.11 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:4 laying floor finished complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:3 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
Hacking out old brocken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounding, glazed with putty or fixed with beads complete all as specified and directed.
M&L for 4.0mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
S &F, in repairs, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
M & L for rendering 10 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
Supply only integral water proofing compound.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of OBD incl one coat of primer complete all as specified and directed
M & L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of wall care putty (3mm thick) for smooth finish.etc with roller over one coat of alkali resistant primer including chalk whiting complete all as specified and directed.
M&L for preparation of new plastered surfaces on walls, chajjas,filling of hair line cracks with white cement and applying two coats of 100% anti fungal weather resistant acrylic paint over a coat of acrylic primer in approved shade and as per manufacturer's instructions including necessary scaffolding complete all as specified and as directed.
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided and disposing off the rubbish outside MD land complete all as specified and directed.
M&L PCC 1:3:6 C-2 (using 20mm graded crushed stone aggregate) as in plinth protection, sub base of floor ( 75mm thick ) finished even and fair all as specified.
Dismantling of ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12.5 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and providing POP finish to the ceiling and applying two coat of OBD complete all as to the satisfaction of Engr - in - Charge
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Dismantling of roof terracing cement / brick concrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate with 2% by weight of cement or as per manufacturer's instructions water proofing as in levelling course, haunching, coping and similar works over RCC roof surface and RCC over head tank top surface including rounded or chamferred on edges and formwork etc all as specified and directed.
M&L for application of 5 layer of water proofing system on leaking roof / wall by through surface preparation opening and filling of cracks, application of absorption coat of Thermacool WP51 application of two coats of elastomeric (thermacool WP51+ cement ) waterproofing layer and topcoated with two coats of thermacool 0.3c elastomeric , waterproofing solar IR heat reflective coating having a min service life of 7 years, complete all as specified and directed.
M&L 100 mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone aggregate) as in hardstanding, path etc incl finishing cement concrete surface even and smooth without using extra cement complete all as spd and directed.
M&L PCC 1:4:8 C-2 (using 40mm graded crushed stone aggregate) as in sub base ( 75mm thick ) finished even and fair all as specified.
M& L for 80mm thick Machine pressed precast paver block M-40 grade laid over sand cushioning after consolidation set and levelled the paver block on proper level with inter locking and size conforming to IS 15658-2006 with grey cement and pigment (LAQUER FINISH) etc complete all as specified and as directed Note: sand cushion will be measured separetely.
Supply only sand cusion for paver blocks complete all as specified and directed.
M&L for chequered cement concrete tiles 25cmX25cmX22mm thick,set jointed in neat cement slurry in floors with grey cement and pigments and including over 20mm thick screed bed in CM 1:4 etc and as approved by EIC
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs etc all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including non metallic PVC conduit ISI marked not less than 20/25 mm dia concealed on wall,ceiling with all fittings including tee,junction boxes PVC connector and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified Note:1. colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green) 2. Modular metal flush box,white cover plates etc will be paid saperately.
All as per item No 60 above but one 5 Amps switch socket on independent board complete all as specified and directed.
All as per item No 60 above but one 5 Amps switch socket on same board complete all as specified and directed.
All as per item No 60 above but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
Material and labour in repairs for point wiring complete with 4 sqmm PVC insulated unsheathed 1100 volts grade FRLS cable stranded copper conductor single core drawn through and including concealed on rigid PVC conduit and conduit accessories of 20/25 mm complete with sunk iron pressed steel terminal box concealed in wall for fitting mounting switch/ sockets regulators etc cover and with 4 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one15 Amp socket point for connecting water coolers/ AC/Gysers etc complete all as specified and directed.
Supply and fix in repairs switch modular type 6 Amp one way, 1 module complete all as specified and directed.
Supply and fix in repairs switch modular type 16 Amp one way, 1 modulecomplete all as specified and directed.
Supply and fix in repairs socket modular type 2/3 pin combined 6 Amp 2 module type complete all as specified and directed.
Supply and fix in repairs socket modular type 3 pin combined 6/16 Amp 2 module type complete all as specified and directed.
Supply and fixing in repairs ceiling fan modular regulator stepped type 120 watts AC 230 V 2 module type complete all as specified and directed.
Supply and fix in repairs ceiling rose surface backelite three terminal complete all as specified and directed.
Supply and fixing modular metal flush box 1/2 module complete all as specified and directed.
Supply and fixing modular metal flush box 3 module complete all as specified and directed.
Supply and fixing modular metal flush box 6 module complete all as specified and directed.
Supply and fixing modular metal flush box 8 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 2 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 3 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 6 module complete all as specified and directed.
Supply and fixing modular white outer cover plate with inner frame 8 module complete all as specified and directed.
Supply and Fixing Modular AC Box With Mini MCB,3 Module power unit 25 A SP MCB Including ISI Plug top etc complete all as specified and directed.
S & F in replacement LED tube light 4' long with all fittings and fixure including poly carbonate diffuser and aluminium body, internally pre wired and connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitabe size 20 watts complete all as per specified and directed.
S & F in replacement LED tube light 2' long with all fittings and fixure including poly carbonate diffuser and aluminium body, internally pre wired and connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitabe size 10 watts complete all as per specified and directed.
Supply and fixing in repairs high bay LED light fittings with highly efficient LED baylight made of pressure die cast aluminium housing extraded aluminium heat sink & enclosed with toughended glass IP 66 of capacity 110/ 120W , power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on truss with MS Clamps made out of 25x5mm flat iron with nuts, bolts etc complete complete dismantling existing unserviceable high bay fittings all as specified and directed. Note:1..Guarantee period as per OEM.
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP656,LEDs 100 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting complete. Note 1..Guarantee period as per OEM.
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 20/25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 6 sqmm plus one run 6 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 20/25 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 10 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 10 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 10 sqmm plus one run 10 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
M & L for rewinding the exhaust fan of any sweep , cutting and taking out unserviceable winding and rewinding with the same gauge copper super enamelled winding wire including all insulating material required as per standerd practice , warnishing, drying, backing , etc complete all as specified and directed .
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs MCB SPN 240 Volts 32 Amp breaking capacity 10 KA rating complete all as specified.
Supply and fix in repairs MCB SPN 240 Volts 40 Amp to 63 Amp breaking capacity 10 KA rating complete all as specified.
Supply and fix in repairs MCB SP 240 Volts 6 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.
Taking down and opening / dismantling of Exhaust Fan of any sweep , cleaning , overhauling complete oiling , greasing including replacement of defective capacitors, worn out bushes , bearings , shaft , rubber reel , nut , bolt, cotter pin, etc where necessary checking for smooth running testing complete including refixing on original position all as specified and directed. (Note : The rate quoted including taking down of fans and the repair and replacement of spares as required at site)
M & L for painting of ceiling fan of 1200 /1400 mm sweep with two coats of synthetic enamel paint over a one coat of red oxide primer after preparing the painting surface etc complete all as specified and directed.
All as per item No.93 above but for exhaust fan of any size complete all as specified and directed.
Supply and fixing LED luminare 600mm x 600mm 40 watt ,220 V AC Recessed type with high effficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable including connecting up with driver three core flexible copper conductor cases of suitable size complete all asspecified and directed.
Supply and fixing LED Round shape 12 watt ,173mm x 20mm suitable for ceiling cut out of 153mm dia 220 V AC Recessed type with high effficiency PMMA diffuser soft glare free light complete with driver holder & LED lamp suitable including connecting up with driver three core flexible copper conductor cases of suitable size complete all asspecified and directed.
Deduct Credit for Demolished/ Dismantled material Rs. (-) 79737.00 (Minus) as listed in Schedule of Credit Note1: Tenderers will not quote against this item being a tentative amount to be considered to arrive at the 'Contract Sum' Note 2:- The tenderer must keep in mind when quoting rates against items out in multiple store house having height 4 mts to 7 mts. Necessary scaffolding and saftey measures required during execution of work are including in this items.
DWARKESH STRUCT-CON
Vishal Builders
M/s Qureshi Construction Co
M/S VISHRANTA CONSTRUCTION
R J ENTERPRISES
S K ENTERPRISES
Parmatma Enterprises
PANKAJ AND BROTHERS
shine industries
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .