Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC AOC | |
| 2 | L2₹6.6 L+₹75,479.50 (12.8%)Rejected-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.0 L+₹2.1 L (36.5%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹1.2 L−₹4.7 L (79.5%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹23,900
Closing Date
9 Feb 2022, 6:00 pmClosed
CWE(AF) Tughlakabad
HQ CWE(AF) Tughlakabad
REPAIR/MAINT OF SECURITY LIGHTS, DG SET, TRANSFORMER, VCB, EARTHING, SOLAR LIGHT AND OTHER CONNECTED WORKS AT AF STN PALAM UNDER GE (P) AF GURGAON
2022_MES_501826_1
CA NO. CWE/TKD/GUR/TOKEN-74/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (P) AF GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (P) AF GURGAON
₹23,900
Yes
28 Feb 2022
15 Jan 2022
11 Feb 2022
15 Jan 2022
9 Feb 2022
28 Jan 2022
Amount
M&L for taking out of Air Circuit Breaker LT 415 volts up to 800 Amps from existing position, dismantling the same and overhauling/maintenance/repair the same including replacement of minor spares,assembling the same and refixing to the existing position including adjustment of load and testing complete all as specified and directed.
M&L for painting to electrical equipments steel sections, rolling shutters etc with two coat of synthetic enamel high glow paint 1st grade including preparation/cleaning of steel surfaces complete all as specified and directed.
Supply and replacement of Silica gel of superior quality of size 5 to 10 mm complete all as specified and directed.
Dismantling of PT pump assembly from DG set of Make - Cummins /Ruston/Kirloskar engine for repair, cleaning, service, overhauling of pump assy with necessary calibration including replacement of spares parts complete all as specified and directed.
M&L for taking out self starter 12/24 volt from the DG Set, transportation to workshop opening/disconnecting all internal connection, cleaning the same taking out burnt armature, segregation serviceable parts for re-use, rewinding of armature with existing size of copper wire. Reassembling the same with replacement of of carbon brush 01 set, Beadex pinion 01 No, Half clutch assy 01 No, Field coil 01 No, Solonoid switch- 01 No., Commitator 01 No and other required parts and fixing the self starter on the engine at site and testing after that complete all as specified and directed.
M&L for dismantling of starting system of 100/63/40/25KVA DG set including necessary wires and supply and fixing new starting system with maint free lead acid battery 12 V ,150 AH 01 No with copper terminal cable of 25 Sqmm single core approx length 1.5 Mtr each for negative and positive terminal and 0.5 mtr for inter connection including necessary brush terminals complete of DG set including testing complete all as specified and directed. Make Exide/Amaron with 24 months replacement waranttee.
Taking out of old unserviceable/defective/old vintage/ obsolete model of relays from 11 KV VCB's and Supply and fixing over current and earth fault electronic relay. Make - L&T Cat No- MC61A-nX2200 suitable for 11 KV VCB like as CG/ABB/Areva including necessary addition/ alternation of VCB front panel including cutting/welding of front side of panel board to match & fixed the new relays to the existing panel board/position including necessary touch up to the panel board all as completed testing of over load and earth fault protection complete all as specified and directed.
M&L for dismantling of starting system of 125 KVA DG set at 27 ED, including necessary wires and supply and fix new starting system of maint free lead acid battery 12 V ,200 AH 01 Nos with copper terminal cable of 25 Sqmm single core approx length 1.5 Mtr each for negative and positive terminal including necessary brush terminals complete of DG set including testing, complete all as specified and directed.Make Exide/Amaron with 24 months replacement waranttee.
Dismantling of injector any DG Set in MCU and ED,s for repair, cleaning of and overhauling of the same with necessary calibration including replacement of necessary parts as required, complete all as specified and directed. Note : Spares parts required shall be measured and paid separately under respective item.
Supply only in replacement of kit injector for incorporation to the injector assy complete all as specified and directed.
Inspection of the DG Set of capacity 25 to 125 KVA in ED & MCU area,finding out defects, cleaning dismantling repair/recondition servicing of the complete DG set, setting of valve timing by replacement of spares as required including wiring testing complete all as specified and directed.Make:- Kirloskar Note : (i) Spares parts required shall be measured and paid separately under respective srl item No-11.01 to 11.28 her-in-after. (ii) All the spares shall be of the make of DG set. (iii) The spares which are not available of the make of DG set shall be provided as approved by GE.
Supply of spring washer Cat part No-602160100100 of Make:- Kirloskar
Spring washer Cat part No -602180100120 of Make:- Kirloskar
Binjo screw injector Cat part No - 604043200023 of Make:- Kirloskar
Set of flexible fuel pipe Cat part No - 123200190058 of Make:- Kirloskar
O' ring injector Cat part No -604931040203 of Make:- Kirloskar
Set of copper washer Cat part No - 123200190098 of Make:- Kirloskar
Fuel filter elements set pre mico.
Set of belts of Make:-Fenner
Disposalable oil filter elements.
Set of Hoses Cat part No - 123200190258 of Make:-Kirloskar
Air filter complete.
Set of hoses clips Cat part No -123200190268 of Make:-Kirloskar
Cylinder liner with 'o' ring Cat part No -62320132044 of Make:-Kirloskar
Set of rings Cat part No -123200190278 of Make:-Kirloskar
Complete set of gasket Cat part No -123200193567 of Make:-Kirloskar
Piston ring set of Make:-Kirloskar
Sleeve of Make:-Kirloskar
Connecting rod bearing pair of Make:-Kirloskar
Rubber hose of Make:-Kirloskar
Washer cranks case of Make:-Kirloskar
Fuel pipe of Make:-Kirloskar
Hex screw tappet cover of Make:-Kirloskar
Hex screw oil sump of Make:-Kirloskar
Allen screw suitable to DG Set
Tappet adjusting screw suitable to DG Set
Water pump set suitable to DG Set
Cooling water pipe suitable to DG Set
HRC fuse suitable to DG Set
Supply,filling and toping up of lubricating oil of specified grade for DG set as approved complete all as specified and directed. Make - HP/Castrol
Supply,filling and toping up coolant in DG set of any capacity complete all as specified and directed. Make - HP/Castrol
M&L for repair of radiator set complete with rusted out parts like coils, tanks, hose pipes, fan bels, fan blade complete all as specified and directed.
M&L for painting to the DG Set of 250/200/125/100 KVA capacities by applying 1st grade synthetic enamel spray duco paint in existing colours including fuel tank foundation base ,canopy and panel board after cleaning & removing of existing rust grease oil spot etc and preparation of surfaces complete all as specified and directed. Make : Berger/Asian/Jhonson/Nerolac
Detecting the fault of any capacity of DG Sets and any location by providing skilled trademan & helper with necessary safety and working equipment such as ,multimeter ,speedometer and other reqd tools and plants and rectified the defects on top priority basis as and when reqd including testing complete all as specified and directed.
Supply and incorporation of distilled water for lead acid battery complete all as specified and directed.
M&L for providing Chemical earthing with copper earth plate 900mm x600mm x5mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc complete with alternate layer of salt crystal and charcoal and Magnesium sulphate crystal as specified below and directed:- (a) The earth pit should be of minimum 12 feet depth and 4 feet width. (b) The copper plate should be of 900mm x600mm x5mm thick. (c) The copper strip should be of 32mmx6mm (cross section) up to 7.5 mtr. (d) The quantity used should be:- (i) Charcoal - 250 Kg (ii) Salt crystal - 200 Kg (iii) Magnesium sulphate crystal - 100 Kg (e) 3/4 inch dia GI pipe of enough length to reach just above copper plate fitted with funnel, meshed along with cap and running water should be provided for keping the soil wet approx one mtr GI pipe be kept out side for connection of running water. (f) The pit shall be constructed in PCC 1:2:4 type B1 using (using 20mm grage stone aggregate) RCC slab shall be provided in RCC 1:2:4 type B-1 (using 20mm grade stone aggregate) 50 mm thick pit cover reinforced with 8mm dia TMT bars 75mm c/o both ways MS handle 12mm dia, PGI funnel wire mesh and GI watering pipe of 20mm bore (light grade) and earth lead protection pipe 50 mm bore (light grade) shall be including the item.
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in cement mortar 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all necessary excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed.
S&F in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos.8mm dia 25 mm long hex .head screw fixed inside cubical shape enclosure made out CRCA sheet 2.0 mm thick with front detachable cover, anodized fixing screws, cap washers 4 Nos to be mounted on wall with wooden plugs & screws 4 Nos, duly painted inside and outside by two coat of aluminium paint over a coat of primer over all dimension of enclosure200mm x 150mm x 100mm (depth) complete all as specified and directed.
S&F in replacement of copper strips of size 25mm x 3 mm with all fixing arragement such as clamps/MS screws/saddles /PVC gutka/brass nut bolt/porcelain insulator & washers etc complete all as specified and directed
S&F in replacement of aluminium strips of size 25mm x 3 mm with all fixing arragement such as clamps/MS screws/saddles /PVC gutka/brass nut bolt/porcelain insulator & washers etc complete all as specified and directed .
S&F in replacement of galvanized iron strip of size 25mm x 3 mm with all fixing arragement such as clamps/MS screws/saddles /PVC gutka/brass nut bolt/porcelain insulator & washers etc. complete all as specified and directed .
S&F of lightning conductor air termination, single pointed copper rod 12 mm dia and 300 mm long including fixing of MS clamps with nuts & bolts and screws complete all as specified and directed .
S&F of lightning conductor air termination, single pointed aluminium rod 12 mm dia and 300 mm long including fixing of MS clamps with nuts & bolts and screws complete all as specified and directed .
Testing of earthing resistance as and when required with working equipments such as earth tester etc. in prensece of user & MES rep and maintaining test result to the binding resister for record complete all as specified and directed . Notes:(i) The contractor should report with in two days after intimatation to carry out the earth test as a whole or partially of the building. (ii) Earth testing will be done in monthly basis. (iii) Each month of each earthing measured seprately.
Dehydration of tranformer oil, obtained from transformers/ voltage stabilizer etc. Dielctric strength shall not be less than 40 KV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine including replacement of unserviceable silica gel and toping up/ replacement of unserviceable transformer oil complete all as specified and directed. Note:-- Transformer oil for filling/toping up and Silica gel shall be measured and paid seperately under respective item.
Supply & filling, topping up of transformer oil of dielectric strength 40 kv and above in transformer at different loaction in situ (testing of oil shall be carried out in prensece of Engr in charge by an authorised agency and testing certificate shall be submitted duly signed complete all as specified and directed.
Repairs of earth pit cover including PCC1:2:4 type B-1 using 20mm graded stone aggregate ,brick work using sub class -B bricks in cement mortar1:6 & earthwork including plastering in cement mortar 1:6 complete all as specified and directed.
M&L for treatment of existing high resistance earthing pit by pouring of salt water solution made of 20 ltrs of water and 5 Kg of salt in the trench to be prepared all around the existing earth pit with radius 60 cm from the centre of the earth pit to the centre of the trench with a depth not less than 30 cm below ground level including necessary earthwork complete all as specified and directed.
Balancing the load of LT 415 Volt overhead/under ground system of any bldg /feeder/ panel board any location by providing skilled trademan & helper with necessary safty and working equipment scuh as clamp meter , high voltage megger tools, safty belts, hand gloves, crimping tool ,other reqd tools and plants and rectified the unbalance load on top priority basis/as and when reqd including testing complete all as specified and directed.
Disconnection the electric supply and dismantling the section of high mast 16/20 mtr hegiht including fittings complete if requried by manually / hydra at AF station palam for servecing, repair of gear motor and replacement of steel rope and chain etc. refixing the same after repair/replacement of above items and testing complete all as specified and directed.
S&F in replacement of solar panel die casting high quality aluminium alloy housing capacity 20W LED 6000,160LM/W , LI-PO4 battery : 48A, 12.8V, solar charging time:10-12 hrs by bright light sunlight, lightinng time :3 nights with different lightning mode, disharchging temparture: 20 degree centigrade to 60 degree centigrate and complete connecting accessories GI bracket size upto 32mm dia GI pipe medium grade upto 1.2 mtr length bend in shape as required with MS flat iron clamp nut and bolt ,washer etc as per suitable street light/solar light pole and connecting accessories , necessary connection and testing complete all as specified and directed. Model No.SELF-20-20W, MAKE : SARRVAD and equivalent
Dismantling of mechanism system of defective 11 KV VCBs, repair/replace the unserviceable item such as closing/triping coil vaccum interrupter tube ,moving contract and spring charging motor etc including overhauling the same by the service engineer after necessary cleaning with CTC ,and providing silicon grease to all moving parts including adjustment of all springs etc and made 100% serviceability and testing complete all as specified and directed. Note:- Closing/triping coil, vaccum interrutertube ,moving contact and spring charging motor shall be measured and paid separately under respective item.
M&L for insulating materials for applying 11KV busbar insulators , CT"s & PT's for better insulation resistance of the system after necessary cleaning with carbon tetra chloride chemical complete all as specified and directed.
Taking out defective / unserviceable/ obsolete model indicator lamp from 11KV VCBs supply and fixing new indicator lamp LED type of different colour of existing ,60 mm 30 volts complete all as specified and directed.Make - Siemens / L&T
M&L for spray painting outside of 11KV VCBs panel/ bus copler with one coat of synthetic enamel paint 1st grade (moisture proof) after preparation cleaning of steel surfaces complete all as specified and directed.
S&F busbar insulator suitable for 11KV VCBs complete all as specified and directed. Make-as per sample
Disconnection the transformers 11 KV /433 volts of any capacity and ED/MCU location AF station palam by providing skilled trademan & helper with necessary safty and working equipment scuh as clamp meter, high voltage megger, safty belts, hand gloves, crimping tool, other reqd tools and plants and serveceing /cleaning of transformer and HT/LT bushings, tightning of cable lugs and replacement of burnt lugs/socket on top priority basis and reconnection the same including testing complete all as specified and directed.
Labour only for lifting of solar street light pole with help of manual/ Hydraulic crane after breaking PCC foundation with the help of hammer drill etc as per standard engineering practice and carefully loading and shifting from original location to a distance of not more than 1 KM carefully for erection with including foundation nut and bolt and connecting accessories and necessary connection and testing complete all as specified and directed. Note:- Foundation work shall be measured and paid seperatly.
M/S Anand Enterprises
Parveen Builders
Surjit and Sons
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .