Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-Finance | L1 | Accepted-Finance Being lowest bidder | |
| 2 | L2₹9.1 L+₹13,000 (1.46%)Rejected-Finance | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹9.3 L+₹38,000 (4.26%)Rejected-Finance 4 JHALAWAR ROAD OPPST AIRPORT KOTA 324007 INDIA | KOTA | KOTA | RAJASTHAN | 324007 | L3 | Rejected-Finance Not being lowest bidder |
Tender Value
Refer Docs
EMD Value
₹27,000
Closing Date
3 Mar 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Executive Engineer MID Jammu
Providing, Fitting, Installation, Testing and Commissioning of 05 cusec x 25 meter head split casing pumping unit and allied works at LIS Burejal
2021_IFC_117184_1
MID/J/e-NIT/2020-21/123
Open Tender
Machineries/ Mechanical Engg Items
Lump-sum
25 days
Burejal
As per tender notice
8 documents required · 8 mandatory
₹200
Executive Engineer MID Jammu
₹27,000
Yes
Jammu
9 Mar 2021
18 Feb 2021
4 Mar 2021
18 Feb 2021
3 Mar 2021
20 Feb 2021
18 Feb 2021 - 1 Mar 2021
19 Feb 2021
180 days
Amount
Dismantling of the 3.5 cusecs split casing pumping unit no II (5 ft x 2.5 ft x 3.5 ft) at lift irrigation station, Burejal by way of demounting the pumping machinery from the bed plate after removing the pump, motor, electric connections, coupling pulleys, suction and delivery pipes and finally removing the base frame. Breaking the damaged RCC foundation block with the help of Chisel, concrete cutter, electric jack hammer, tools / tackles. Cutting of steel members with the help of cutter step wise during the process of breaking the RCC block and stacking. Completely removal of broken concrete, soil and tmt bars from pump room in such way that the machinery and electric equipments of other pumping machinery are not damaged/ affected. Disposal of salvage of dismantled foundation away from pumping room up to the distance of 100 m at such place where irrigation land and water source is not polluted. Laying of new RCC foundation block of size length – 5 ft x width- 2.5 ft x depth- 3.5 ft by way of making surface even for laying of new RCC foundation block. Fabrication of steel mesh out of 10 mm TMT bars members placed vertically and horizontally at an equidistance of 6 inches. Laying of 6 inch concrete base at the bottom to level the surface. Placing of fabricated iron mesh in foundation pit and levelling / aligning it with the pumping unit. Fabrication and grouting of 6 No. foundation bolts of size 2.5 ft in foundation block. Laying of RCC foundation block of size 5 ft x 2.5 ft x 3 ft by filling the concrete in the ratio of 1:1.5:3. The size of the block above the ground level should be of original size and alignment in respect of suction and delivery pipes. The block shall be filled with rich mixture of concrete using vibrator for compaction. The entire block as one unit is to be laid in such a way that it can damp all types of mechanical vibrations created by dynamic load of pumping unit without causing any defect to the pumping unit as well as to the block itself. Fixing of the base frame after levelling and fastening with foundation bolts. Complete job includes cost of material such as cement, sand, steel, shuttering charges, charges for concrete mixture, vibrator charges and labour charges of skilled as well as semi skilled labour, curing charges. Providing, Fitting, Installation, Testing and commissioning of 05 cusec discharge x 25 meter head split casing pump with motor , coupling pulley and base frame at Lift irrigation station Burejal. Recommended make of Pump : - Kirloskar, KSB, Mather Platt, Beacon Weir. Type of Pump : - Split casing pump. Recommended make of Motor : - Kirloskar, ABB, BHEL, Seimens. Material of construction 1. Impeller:- Cast Iron / Cast Steel / Stainless Steel / Chrome Steel / Duplex Steel 2. Pump Shaft: -.Carbon Steel / Stainless Steel / Duplex Steel 3. Wearing Ring: - Cast Iron / Bronze/ Steel 4. Pump casing: - Cast Iron / Cast Steel / Stainless Steel / Duplex Steel 5. Gland:- Cast Iron / Bronze 6. Shaft Sleeve:- Stainless Steel / Bronze 7. Base frame –Mild steel. 8. Motor- Minimum 70 HP, Nominal speed 1450RPM or compatible with pumping unit. Shifting for pumping unit to Lift irrigation station, Burejal by carriage vehicle. Unloading of pumping unit at roadside using crane/ manual labour. Carriage of pumping unit to pump room by manual labour on head load. The base frame should be fabricated out of MS channels of totally welded construction and of sturdy design, adequate dimensions having true and machined surface suitable to with stand load and vibrations of machine. Base frame should have holes for fastening motor and pump. The base frame must be levelled to avoid any misalignment of pumping machinery. Fitting and Installation of motor, pump with coupling pulley and then fitting on base frame with help of chain pulley block, tripod stand and manual labour. Complete job. includes cost of material, consumable, handling, loading, unloading, transportation charge, labour charges for both skilled /semi-skilled labour and hiring charges for Crane , tripod stand, tools and tackles required during the execution of the job at site. The dismantled pump 3.5 cusec split casing pump , motor, base frame shall be moved from Pump room to road side on Head load and then loaded to carriage vehicle for transportation from LIS Burejal to mechanical store Jammu and shall be unloaded at store. Note:- The Tenderers are requested to visit the site and quote the rate as per site conditions. Any modifications/ alterations of the job, absolutely necessary if required at the time of execution may be done as per actual site conditions.
Providing, fitting, welding and laying of MS suction pipeline of 300 mm diameter of 8 mm thickness- 40 feet in length for newly installed 5 cusec pumping unit no II from pump to intake source. Providing, fitting of 6 number MS plate flanges with 300 mm internal diameter with suction pipe at different lengths. Welding the flanges to pipes with double layered welding to avoid any leakages. Fastening of suction pipeline with pumping unit using nuts, bolts and rubber gasket. Fabrication of 300 mm diameter MS bend properly flanged at both ends as per site conditions and alignment of pump. Providing and fitting of rubber gaskets between each MS flange joint. Fastening of each length of suction pipe with hexagonal nuts and hexagonal bolts. The job includes excavation of earth outside the lift irrigation station for lying of pipeline and refilling of earth after laying of pipeline. Providing and fitting of new 300 mm diameter (Kirloskar/ L&T/ KSB make), foot valve on the suction end of the pumping unit no II. Job includes providing of new nuts, bolts and rubber gasket. Dismantling of delivery pipeline of old split casing pump in different alignment by way of cutting the rusted nuts and bolts with gas cutter. Removing of damaged delivery pipeline and providing, fitting of 250 mm diameter pipeline 20 ft in length with MS plate flanges on both ends. Fabrication of 250 mm diameter MS bend properly welded with MS plate flanges on both ends as per alignment of pump. The delivery line should consists of sluice valve and non return valve. Fastening and laying of delivery with new nuts, bolts and rubber sheet between the flanges. Total number of flanges required for delivery line will be 5 flanges. Providing and fitting of 250 mm diameter, flanged ends cast iron sluice valve with PN 1.0 of reputed make (Kirloskar/ L&T/ KSB make), on delivery side of the pumping unit with rubber gaskets, nuts and bolts. Providing and fitting of 250 mm diameter, flanged ends cast iron non return valve with PN 1.0 of reputed make (Kirloskar/ L&T/ KSB make), on delivery side of the pumping unit with rubber gaskets, nuts and bolts Complete job includes cost of material, welding charges, skilled/ semi skilled labour, transportation charges, carriage charges of material on head load from road side to lift station on head load. Note:- The tenderers are requested to visit the site and quote the rate as per site conditions. Any modifications/ alterations of the job, absolutely necessary if required at the time of execution may be done as per actual site conditions. Note :- The firm has to give rebate on old damaged dismantled pipes and other items.
Rebate on Old Parts
GIANI ENGINEERING WORKS
Guru Nanak Engineering Corporation
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .