Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | ₹40.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹41.4 L+₹98,799 (2.45%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | ₹41.4 L+₹98,799 (2.45%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹49.3 L+₹8.9 L (22.0%)Rejected-Finance | ₹49.3 L+₹8.9 L (22.0%) | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
11 Nov 2021, 6:00 pmClosed
CWE Patiala
HQ CWE, Bldg No 26, New Lal Bagh, Patiala 147001
SPECIAL REPAIR TO INCOMING HT FROM PSPCL BY CONVERSION OF OHL TO UG CABLE AT FAD DAPPAR UNDER GE PROJECT DAPPAR
2021_MES_466904_3
8321/CWE/PAT/T-28/21-22
Open Tender
Civil Works
Lump-sum
180 days
Dappar
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE Project Dappar
₹88,000
Yes
27 Dec 2021
30 Oct 2021
13 Nov 2021
30 Oct 2021
11 Nov 2021
6 Nov 2021
30 Oct 2021 - 5 Nov 2021
Amount
Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically demolition provided for(reinfocement should be cut as required to facilitate demolition) complete all as specified and as directed.
Demolition of cement concrete un-reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and as directed.
M&L Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed
M&L RCC type A0, 1:1.5:3 (using 12.5mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L RCC type A0, 1:1.5:3 (using 12.5mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L RCC type A0, 1:1.5:3 (using 12.5mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and as directed
M&L RCC type A0, 1:1.5:3 (using 12.5mm graded stone aggregate)in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter to flat complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L Mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bar 5 mm dia and over upto and including 10 mm dia in stirrups, spaces and binders, cut to length, bent to shape required including cranking bending spirally hooping for column, hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9mm dia or securing with clips quality conforming to, as in stirrups, spaces and binders complete all as specified and as directed.
Demolition of brick work built in cement morter etc complete all as specified and as directed.
M & L brick work with subclass 'B' bricks straight or curved on plan to any radius built in CM 1:6, complete all as specified and as directed.
M&L for rendering 15mm thick in two layers (10mm and 5mm respectively) in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed. Note : WPC will be measured and paid separately.
Supply only integral liquid water proofing compound complete all as specified and as directed.
M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed.
Applying 02 coats of exterior emulsion paint (light shade) @ 5 sq.m/litre/2 coats by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq.m/litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and as directed. Make of Exterior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Exterior Emulsion : Asian (ACE) / Berger (WALMASTA) / Nerolac (SURAKSHA SUPERIOR)
M&L for rendering 10 mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying 02 coats of interior emulsion paint (light shade) @ 10 sq.m/litre/2 coats by using roller to wall surfaces over & including a coat of interior wall primer @ 10 sq.m/litre/1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed. Make of Interior Wall Primer : Asian / Berger / Nerolac [Best Quality]. Make of Interior Emulsion : Asian (TRACTOR) / Berger (BISON) / Nerolac (BEAUTY SMOOTH) .
M&L for rendering 10 mm thick in cement mortar 1:4 on ceiling finished finished even and smooth without using extra cement complete all as specified and as directed.
M&L 3 coat of white washing as in ceiling of newly plastered surfaces including preparations of surface etc. complete all as specified and as directed.
S&F Spray Docu painted Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, hold fast etc., complete all as specified, size 105 x 60mm and incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and as directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in holdfast blocks complete all as specified and as directed.
75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing and plinth protection complete all as specified and as directed
M&L Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 150 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed
100 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified and as directed.
M&L PCC type B0, 1:2:4 (using 12.5 mm graded aggregate ) 25 mm thick, as in floors complete all as specified and as directed.
100 mm thick Cement concrete type E2, 1:5:10 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing complete all as specified and as directed.
M&L for 50 mm thick plain cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in floor finished even and smooth using extra cement all as specified and as directed.
Forming Construction joint 30 mm deep x 10 mm wide filled with sealing compound grade 'A' complete all as specified and as directed.
S&F factory made flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides with 6mm thick lipping frame to match including supply and fixing following items : (a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 4 Nos per leaf (b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf (c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf (d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf (e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf
M&L for Baroda Green marble, machine cut as in shelves/steps/cills/jambs/skirting/border only in tile flooring and the like works and flooring etc, 15-16 mm thick including bull-nose the exposed sides/lengths, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab for fixing on concrete surfaces or with suitable adhesive for fixing on un-polished kota stone slabs including rubbing, cutting and mirror type granite polishing and including dismantling/demolition complete all as specified. Note : Single piece should be used in steps/cills/jambs/shelves.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc complete all as specified and as directed.
M& L Point wiring complete with 1.5 sqmm (nominal area) PVC insulated PVC unsheathed multistranded copper condutor single core cable 1100 volts grade, FRLSH, ISI marked drawn through and including heavy duty non metalic PVC conduit, ISI marked, not less than 20 mm dia of thickness 1.8 mm concealed in wall, roof, etc, with all connected fittings including base plate, cover plate, pressed steel terminal boxes suitable for mounting modular switches, sockets etc and including PVC insulated and unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and as directed for One light / fan / Bell point controlled by one switch Note:- Switches , sockets, ceiling rose, regulators etc shall be measured and paid separately. Quoted rate is deemed to be inclusive of cost of cutting chases in wall for incorporting PVC conduit and cost for making good to existing wall with CM 1:4 and painting same so as to match the existing surface.
All as per Sl item No 36 herein before but One 5 pin socket outlet independent 5 Amps complete all as specified and as directed.
All as per Sl item No 36 herein before but One socket outlet 5 Amps on the same board with other switches complete all as specified and as directed.
All as per Sl item No 36 herein before but One 6 pin 5/15 Amps socket outlet independent with 2.5 Sqmm size copper conductor cable and 2.5 sqmm copper cables as earth wire complete all as specified and as directed.
S&F Modular switch 1 way 5/6 A, 1 module type single pole 240 volts complete all as specified and as directed.
S&F modular socket out let 5/6 Amps 2/3 pin 2 module complete all as specified and as directed.
S&F modular socket out let 5/15 Amps 2/3 pin 2 module complete all as specified and as directed.
S&F modular switch 15 Amps 1 way, 1 module complete all as specified and as directed.
Supply and fixing in replacement ceiling rose bakelite, 63.5mm 3 terminals with base plate ISI marked, complete all as specified and as directed.
S&F Sheet metal enclosure MCB SPN distribution board, double door, IP 43 class, including suitable size copper bus-bar, 240V,8 Way with neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and as directed. NOTE - (a). Cost of suitable size cable lugs and materials required for flush fixing of DB is deemed to be included in the quoted rate. (b). Cost of cutting chases in wall for flush fitting of DB and making good to wall with CM 1:4 and painting the same in order to match the same with the existing wall all to the satisfaction of Engr-In- Charge is deemed to be included in the quoted rate.
M& L Earthing complete by using GI wire as earthing lead and MS galvanized earth plate of size 60 cm x 60 cm x 6.3 mm as earth electrode surrounded by charcoal and salt, buried directly in ground vertically in pit of depth not less than 2.25 meter below the ground with top edge of the earth plate at a depth of less than 1.5 mtr below ground level surounded from all sides with mixture of charcoal dust and common salt in alternate layers and electrode connected to galvanized iron wire 4 mm dia by means of bolts, nuts, checknuts and washers of galvanised iron connected to main switch board or main control board all as shown in electrical plate No 3 of SSR 1991. Pt I and including necessary exc. and earth work. The rate also include testing, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC chambers in cement concrete (1:3:6) type CI 40 mm thick RCC(1:2:4) type B-1 cover and CI frame etc.complete all as specified and as directed.
Taking down existing unsv cable and Material & Laying XLPE UG insulated, armoured heavy duty electric cable in repair with aluminium conductor multi stranded, 1100 volts , 2 core 10 Sq mm complete all as specified and as directed.
Excavation in trenches in soft/loose soil n exc 1.5m wide and n.exc1.5m deep and getting out includingforming bottom surfaces to required level or slope for taking out embeded cables,brick/pcc protective tiles complete all specified and all as directed by engineer incharge.
M & L sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.). Complete all as specified and as directed. (Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes).
M&L precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and as directed.
Removal of surplus excavated soil to a distance exc 50 m but not exc in 100 m and deposited where directed at a level n'exc 50 m above the starting point complete all as specified and as directed.
Returning filling in soft/ loose soil in trenches including spreading, leveling watering and well ramming in 25mm thick layer complete all as specified and as directed.
Supply and fixing 40 mm dia 'light grade', galvanised pipe with all fitting; laid in trenches/ passing through roads/drains alongwith cutting and making surface good with existing surface complete all as specified and as directed.
M&L for PCC type C2 1:3:6, using 40 mm graded stone aggregate in foundation complete all as specified and as directed.
Material & Labour for cement concrete 1:2:4 type B - 1 using 20mm graded crushed stone aggregate in coping pedestal to poles including provision of necessary frame work finishing the expossed surface even and smooth complete all as specified and as directed.
Supply and erection of steel tubular swaged poles welded with cast iron base plate of size 30cmx30cmx6mm thick finial taper plug bolts nuts & screws as specified type 410 SP 55, 11m long in truly vertical position till setting of PCC foundation complete including painting with two coats of aluminium paints of approved quality over one coat of red oxide primer as exposed surface & two coat bitu-mineous paint for embedded portion incl. painting five no. strips upto 30 cm on bottom of the pole with black and red colour paint alternately all as specified and as directed. Note :- Excavation of post hole, PCC required for foundation and coping will be measured & paid under relevant items of Sch 'A'.
Supplying, installing, testing and commissioning complete HT 11 kV, 200 Amp outdoor type gang operated single air-break switch, triple pole, tilting type, vertical mounting, mechanically operated consisting of hot dip galvanised channel iron base having 3 Nos 11 KV Post type insulator in stack - 3 stack per phase, copper or copper alloy high pressure heavily tinned contacts, MS arcing horns capable of breaking the magnetizing current with operating mechanism worked from ground level complete with horizontal connecting square bar, GI pipe of size not less 25mm dia, medium grade and of suitable length as down rod levers coupling & operating handle with locking arrangement connected with new ACSR conductor (jumper) - set of 3 duly logged incoming and out going with steel nut bolts and washers incld. dismantling and taking out old switch and connections complete complying to IS 9921/1985 (Part I to IV) or its latest amendment all as specified and directed by Engr-in-Charge. NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs incld. cost of nut, bolts, washers, etc. minor items required for the efficient operation of GOD.
Supply and install drop out fuse complete, HT 11 kV, 200 Amps fuse link consisting of channel iron base having 1 No 11 KV post type insulators in stack & 2 stack per phase complete with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact complete manufactured as per IS 9385 complete all as specified and as directed. NOTE - The quoted rate is deemed to be inclusive of cost of cutting, welding, drilling etc. and other jobs incld. cost of nut, bolts, washers, etc. minor items required for the efficient operation of DO fuse unit.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat, size 300mmx 180mm x 40mm complete all as specified and as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 11 kV of size 25 x 20 cm complete all as specified and as directed.
M&L cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint complete all as specified and as directed
S&F cable jointing kit for 11 KV grade cable for indoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and as directed.
S&F cable jointing kit for 11 KV grade cable for outdoor termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size 240 to 300 sqmm complete all as specified and as directed.
M&L Heat shrinkable straight through cable jointing kit suitable for earthed 3 core 240 sqmm HT 11 kV XLPE aluminium conductor cable incld. disconnecting concerned cable, cutting out burnt/damaged jointing kit, jointing new kit inld. testing and commissioning of the complete cable to the complete satisfaction of Engr-in-Charge all as specified and directed. NOTE- (a). The quoted rate is deemed to be inclusive of cost of saddling or clamping of cable all as directed. (b). Contractor has to arrange proper electrical shutdown after informing to depratment concerned. (c). Cost of connected excavation, soil removal, returning filling in, sand cusshioning and cable covers will be measured and paid in the respective items of the Schedule.
M&L Anti-climbing device; spikes type square and flat including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed.
M&L for galvanised iron pipe 100 mm dia light grade with all fittings and fixed complete to walls and ceiling or laid in trenches floor complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and indicated including testing on completion complete all as specified and directed.
S&F GI strip 32 mm x 6 mm buried in ground connecting at ends, jointing with saddles and fixing screws etc for roof conductors or down conductors above ground complete all as specified and as directed.
S&F Modular Fan step regulator, 100W, 2 Module 240 volts complete all as specified and as directed.
Supply and fixing in replacenment Modular Angle holder Cat Pat NO 39946 of Anchor Equivalent/Havells/SSK with insulated body with back plate for LED lamps complete all as specified and as directed.
Supply and fixing in replacement LED lamp 9 watt, retrofit complete all as specified and as directed.
S&F in replacement LED tube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose complete all as specified and as directed.
Supply and fixing in replacement MCB SP 6 -32 Amps,10 KA,,'C' series 240 V ISI marked complete all as specified and as directed.
Supply and fixing in replacement MCB SPN 06-32 Amps,10 KA 'C' series 240 V ISI marked complete all as specified and as directed.
Supply and fixing heavy duty station class, Gap less type Metal Oxide lightning arrestors, 12 Kv of 10 Kv rupturing capacity complete with all fittings distribution class suitable for 11 KV earthed system discharge capacity 65 Kilo Amps complete all as specified and as directed. Modifications to support structure as per OEM requirements shall be the scope of Contractor. No extra payment will be entertained on this account.
Supply and fixing in replacement Bulk Head LED 10W, 230 V, all as per Crompton Make Cat No. - LBHE-10-CDL or equivalent in Philips/Wipro complete all as specified and as directed.
S&F LED building security light, pressure die cast aluminum housing, 15 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long Med grade GI pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 6 mtr from ground with MS clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose/junction box with 1.5 sqmm PVC insulated 3 core wire complete all as specified and as directed. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate.
Supply, laying in trenches /ducts/fixing on pole/STR with suitable size of GI clamps made out of GI strip 32 mm x 6 mm, XLPE insulated, screened, earthed, PVC bedded, galvanised steel strip, electric power cable (heavy duty) of size 3 core 240 sqmm with aluminium conductor suitable for 11 kV (E) grade as per relevent IS including latest amendment for IS testing, commissionong along with S&F for HT cable route indicator for every 100 m with suitable PCC Foundation complete all as specified and directed including taking out of old burnt out cable alongwith cable covers. Note:- (a) Earth work, EHV cable cover, sand coushioning & GI pipe will be measured and paid seperately. (b) High voltage test to be conducted at site with suitable voltage before and after laying of HT cable and reading shall be recorded jointly and test report to be submitted in triplicate to the Engineer-in-Charge. The cost of the same shall be deemed to be included in the unit rate quoted above.
M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. NOTE - (a). Cost of cutting out of trench for accomodating the machine and making good to the surface after completion of the job are deemed to be inclusive in the quoted rate. (b). Contractor has to rectify any damage to cables, pipes or other govt. property free of cost to the complete satisfaction of Engr-in-Charge. (c). Any extra excavation or the any other connected jobs required other than as mentioned in the scope of work will be measured and paid under the relevant items of this schedule.
Supply, installation, testing and commissioning HT 11 KV, 3PH, 50 Hz, CPRI approved IP 65 protection AC system outdoor type feeder pillar duly powder coated to loop one incoming and two outgoings for 3 x 240 sqmm XLPE 11 KV cable having following specifications complete all as specified and directed :- (a) The cubicle of HT feeder pillar shall be made out of 3.00 mm thick CRCA sheet. The complete cubicle shall be rigid self supporting and free standing. (b) The HT feeder shall have front and rear compartments. Front compartment shall be suitable for connecting the terminals of cables and the rear for cable terminations. Backlite sheet 20mm thick shall be provided for separation of cable termination at front side. (c) The cubicle shall have centre lift up type slanting roof rain hood made up of 3.00mm CRCA sheet. The depth and width of the rain hood shall be at least 120% of the depth and width pillars. (d) The cubicle shall be provided with two Nos of doors for front and for back side alongwith 3 nos of hinges on each door. (e) A centrally operated three position locking arrangement shall be provided for the door. Two keys shall be supplied for each feeder pillar. In addition, angle cleats shall be provided for putting two Nos of padlocks for each size of doors. (f) Adequate ventilation by means of louvers with wire mesh shall be provided on both sides of the pillars and also at the top and bottom of pillars. (g) Asbestos sheets of at least 6mm thick shall be provided on all doors inside. (h) Enameled danger board with "DANGER 11000 VOLTS" mark shall be displayed on the left hand side of front and back doors. (j) Two nos of earthing bolts shall be provided with cubical. One each at front and rear side of Pillar. The same shall be easily accessible. (k) The cable entry shall be from rear side of the pillar alongwith removable gland plate. Cable chamber shall be provided with perforated metal sheet separate for each chamber. (l) Additional door on front side with 14 SWG GI wire shall be provided. Also the detachable frame with 14 SWG GI wire mesh shall be provided at rear side. There shall be firm stop for these wire mesh doors and frame that it shall not move toward inside of pillar / live connections. (m) Bus Bars provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shrinkable sleeve for phase indication. The standard phase arrangement when facing the switchgear shall be R-Y-B from left to right. The set of bus bars 630 Amps rated shall be made up of electrolytic grade aluminium confirming to latest grade of IS. (n) The insulating material used shall be Epoxy type Insulator, with uniform equally spaced rings, suitable for 22 Kv Class insulation Mounting of these insulators shall be with 4 Nos of threaded holes on the central vertical, 10 SWG MS plate. (o) Foundation for the panel should be provided with PCC 1:3:6 type C2, at depth of 150mm below GL and 300mm above the GL with slot openings for I/C and O/G cables. Base frame for cubicle for mounting shall be made out of 40 x 40 x 6mm equal angle iron duly painted.
HARISH SALES CORPORATION
AR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .