Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC The lowest e-tenderer | |
| 2 | L2₹10.3 L+₹44,614.60 (4.55%)Rejected-Finance | L2 | Rejected-Finance Not the lowest e-tenderer |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
6 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Santosh Pandey
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
CONSTRUCTION OF ONE CLASS ROOM AT APS MUMBAI UNDER GE WEST COLABA
2020_MES_404829_2
83992/W/E8
Open Tender
Civil Works
Item Rate
120 days
GE (West) Mumbai
Please refer tender document.
7 documents required · 7 mandatory
₹500
Garrison Engineer (West) Mumbai
₹20,000
19 Feb 2021
22 Jan 2021
8 Feb 2021
22 Jan 2021
6 Feb 2021
25 Jan 2021
22 Jan 2021 - 30 Jan 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation etc or for shaft, walls, manholes, pier holes etc, not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in deep for foundation etc or for shaft, walls, manholes, pier holes etc, not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified & directed by Engineer-in-Charge
M & L for cement concrete in foundation, filling and mass concrete with type D-2, 1:4:8, using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Providing and injecting chemical emulsion for pre constructional Antitermite Treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engr-in-Charge.
Providing and injecting chemical emulsion for pre constructional Antitermite Treatment by Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and as directed by Engr-in-Charge.
Providing and injecting chemical emulsion for pre constructional Antitermite Treatment by Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed by Engr-in-Charge.
Providing and injecting chemical emulsion for pre constructional Antitermite Treatment by Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and as directed by Engr-in-Charge.
Providing and injecting chemical emulsion for pre constructional Antitermite Treatment by Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and as directed by Engr-in-Charge.
M & L for reinforced cement concrete M-30 (design mix) (using 20mm graded crushed stone aggregate) as in foundation, footing, bases of columns, raft and raft beams, plinth beams, mass concrete and similar work etc complete all as specified and as directed by Engineer-in-Charge.
M & L for Reinforced cement concrete M-30 (design mix) (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies etc. complete all as specified and as directed by Engineer-in-Charge.
M & L for Reinforced cement concrete M-30 (design mix) (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span, chajja, pardhi etc complete all as specified and as directed by Engineer-in-Charge.
M & L for Reinforced cement concrete M-30 (design mix) (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts, etc. complete all as specified and as directed by Engineer-in-Charge.
M & L for CRS (Corrosion resistant steel) bars with Fe 500D properties, 10 mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge
M & L for CRS (Corrosion resistant steel) bars with Fe 500D properties, 8 mm dia, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge
M & L for CRS (Corrosion resistant steel) bars with Fe 500D properties, 8 to 10mm dia in stirrups, spacers and binders, temperature bars, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge
M & L for Formwork to sides of concrete foundations, footings, base of columns, rafts and raft beams, sides and soffits of foundations and plinth beams etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
M & L for Formwork to soffits of suspended slabs such as floor slabs, roof slabs, landings, chajjas and similar work not exceeding 200mm thick for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
M & L for Formwork to sides and soffits of floor or roof beams, cantilevers, bressummers, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
M & L for Formwork to sides of pillars, posts, struts, piers, columns, etc. for rough finished square or rectangular surfaces of concrete complete all as specified and as directed by Engineer-in-Charge.
M & L Damp proof course to horizontal or vertical surfaces in cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate), 25mm thick including necessary formwork complete all as specified and as directed by Engineer-in-Charge.
Applying evenly a coat of blown type bitumen of grade RS-1 at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cum per sqm complete all as specified and as directed.
M & L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius with old size bricks, built in cement mortar (1:6) complete all as specified and as directed by Engr-in-Charge
M & L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with integral water proofing compound & finished even and fair complete all as specified and as directed. Note: - Water proofing compound will be measured and paid for separately as "supply only"
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6, including finishing even & smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
M & L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6, including finishing even & smooth without using extra cement complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound. Make - Plastocrete of Sika/Pidiproof LW of Pidilite.
M & L for preparing of new plastered surfaces of wall/ceiling by scrapping/rubbing and applying two coats of Acrylic weather proof exterior paint over a coat of acrylic primer complete including scaffolding complete all as specified and as directed by Engineer-in-Charge and as per manufacturers instructions. Make- (a) Asian Paint - Apex Ultima Protek. (b) Berger Paint - Weather coat smooth. (c) Nitco Paint - Outshine premium 100% acrylic exterior (d) ICI Dulux - Weather shield exterior.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed by Engr-in-Charge.
M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer over a thin layer of wall care putty complete all as specified and directed by Engineer in Charge. Make: SHALIMAR / BERGER / NEROLAC / ICI LTD/ASIAN (Tractor Brand)
M & L for 75mm thick cement concrete (1:3:6), type C-2,using 40 mm graded crushed stone aggregate as in sub base of flooring and finishing the surface even and fair complete all as specified and as directed by Engr-in-Charge
M & L for 75mm thick cement concrete (1:3:6) type C2, using 40mm graded stone aggregate as in plinth protection and finishing the surfaces even and smooth without using extra cement, including joints of plinth protection filled with bitumen mastic (1:3) complete all as specified and as directed by Engr-in-Charge.
M & L for hardcore (broken stone or boulders) of gauge exceeding not exceeding 63 mm, deposited, spread and levelled in layers, not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Filling in floor by approved earth obtained from excavation/brought from outside laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete complete all as specified and as directed by Engr-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any soil complete all as specified & directed by Engineer-in-Charge.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engr-in-Charge.
M & L for light shade vitrified tiles, 8 to 10mm thick, (square/ rectangular) polished, area of each tiles not exc exceeding 0.36 Sqm , in flooring, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, over and including 15mm thick screed bedding in cement mortar (1:6) complete all as specified and as directed by Engr-in-Charge Make:M/s H R Johnson/M/s Orient Bell Tiles/M/s Kajaria/M/s Somani Tiles Ltd/M/s Nitco tiles/M/s Swastik Tiles
M & L for light shade vitrified tiles, 8 to 10mm thick, (square/ rectangular) polished, area of each tiles not exc exceeding 0.36 Sqm , on vertical surface such as skirting, dado, riser/steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles including backing coat 10 mm in CM (1:4) complete all as specified and as directed by Engr-in-Charge. Make:M/s H R Johnson/M/s Orient Bell Tiles/M/s Kajaria/M/s Somany Tiles Ltd/M/s Nitco tiles/M/s Swastik Tiles
S & F plain solid straight chowkats, second class hardwood, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints including making good frame in cement concrete complete all as specified and as directed by Engineer-in-Charge.
S & F Flush shutters, 30mm thick, solid core construction with Particle board core and plywood face panels, one side commercial type and other face covered with decorative face veneer with lipping/frame to match complete all as specified and as directed by Engr-in-Charge.
S & F mild steel work as in hold fast & similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed by Engineer-in-Charge.
M & L for PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in bed blocks for hold fast and all other similar works including necesssary formwork complete all as specified and as directed by Engineer-in-Charge.
M & L for preparing surfaces of wood and wood based materials, steel and iron work, treating ends of posts, hold fasts, backs of chowkats, etc., area tarred exceeding 0.1 sqm but not exceeding 0.5 sqm each and treated with tar or coal tar black paint complete all as specified and as directed by Engr-in-Charge.
M & L for preparing surfaces of wood and wood based materials, steel and iron work, treating ends of posts, hold fasts, backs of chowkats, etc., area tarred, not exceeding 0.1 sqm each and treated with tar or coal tar black paint complete all as specified and as directed by Engr-in-Charge.
S & F extruded aluminium alloy handles, fabricated type, anodised, of size 200 mm complete all as specified and as directed by Engr-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F aluminum anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy , 300mm long, ISI marked complete all as specified and as directed by Engr-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F stainless steel butt hinges, heavy duty of 100mm size complete all as specified and as directed by Engr-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F aluminium handles, cast type, anodised of size 150mm complete all as specified and as directed by Engineer-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, over all length of cover plate 140mm complete all as specified and as directed by Engineer-in-Charge. Make : Classic/ Shalimar/ CLIF/ARGET
S & F powder coated ( any shade approved by GE) aluminium sections for sliding or openable windows, ventilators, doors, partitions etc including fabrication of frame & shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc including all accessories such as glazing clips and rubber beadings for fixing glass panes / wire mesh in frame complete all as specified and as directed by Engr-in-Charge Make : Hindalco/Indal (Indian Al Coy)/Jindal/Associated Profile & Aluminium Ltd/Ajit India Note:- (i) Glass panes /wire mesh will be measured & paid separately. (ii) Rubber beading will not be weighed.
S & F aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture, 1.40mm and fixed with aluminium wire staples or wooden/rubber beads/fillets with painting complete all as specified and as directed by Engr-in-charge.
S & F 4.0mm thick sheet glass, plain, ordinary quality,in square or rectangles, not exc. 0.5 Sqm in each pane, glazing with rubber beading complete all as specified and as directed by Engineer-in-Charge. Make : Modiguard/Atul/Kohinoor/Swastik/Saint Gobain
M & L for machine cut Kota (greenish colour, pre polished) stone slab flooring, 20-25 mm thick, in one piece as in cill/staircase treads etc, over cement screed bed 20 mm in CM (1:3) base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer in Charge.
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle, applying a coat of bitumen primer for bitumen membrane @ 200gms/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps and then applying APP modified bituminous water proofing membrane with mineral finish of 3 mm thick (not less than 3.5 kg/ sqm ± 5 % per sqm, reinforced, weighing not less than160gms/Sqm) shall be laid using Butane Torch application method, overlap while torching shall be 75mm on length and 100mm width side, all angles & bituminious should sealed with extra care to ensure full bondage all joints and changes should covered with CM 1:3 with water proofing chemicals as per manufacturer's instructions and cured well before laying membrane complete all as specified and directed by Engineer in Charge. Make- 1.STP Ltd 2 Texsa India Ltd 3 Dr Fixit 4 Tiki Dan
M & L for Point wiring (concealed type) with 1.5 sq mm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories with concealed 1.2 mm thick pressed steel sunken box and with including modular cover plate and frame, suitable for fixing modular switch socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / bell/ Ex Fan / wall fan controlled by one modular switch, 1 way 6/10 amps, 1 module complete all as specified and directed by Engineer-in- Charge Make of Cable : Anchor / Havells / Finolex / Polycab Make of PVC conduit- (i) Anchor (ii) Modi (iii) Pressfit (iv) Precision (v) Astral
All as per serial no.54 here-in but for one ceiling fan controlled by one switch & regulator
All as per serial no.54 here-in but for One 3 pin socket point 5 Amps on independent board
All as per serial no.54 here-in but for One 3 pin socket point 5 Amps on same board
All as per serial item no 54 here-in-before but for one socket point on independent board, 15 Amp with 2.5 sq mm PVC unseathed FRLSH wire along with 2.5 sq mm FRLSH green colour wire as earth continuity conductor connected to common earth dolly complete all as specified & as directed by engr-in-charge.
S & F Switch, piano type, single pole, one way, 5 amps, 240 volt complete all as specified and as directed by Engineer-in-Charge. Make : (i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
S & F Switch, piano type, single pole, one way, 15 amps, 240 volt complete all as specified and as directed by Engineer-in-Charge. Make : (i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
S & F socket outlet, 2/3 Pin, 5 Amps complete all as specified and as directed by Engineer-in-Charge. Make :(i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
S & F socket outlet, 6/16 Amps, 2/3 pin complete all as specified and as directed by Engineer-in-Charge. Make : (i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
S & F step type electronic fan regulator, capacitor type, 100 watt, 450 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed. Make : (i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
S & F ceiling roses, surface type backalite 65 x 50 mm two to three terminals complete all as specified and as directed. Make : (i) Anchor (ii) Crabtree (iii) Leader (iv) Legrand (v) Havells (vi) C & S Electric Ltd
S & F 20 watt LED, 4 feet long, fixed on & including PVC square for mounting the fittings and electrically connecting with three single core 23/0.0076 PVC insulated, multi strandard, copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing complete all as specified and directed Make:Havells cat pt no LHEXBXPNIN1W020 or equivalent model in Wipro model no - Wipro Garnet 20 W LED Batten 6500K / Philips model No - BN150W LED 20S-6500 PSE ODGR / OSRAM.
S & F LED building security light, 45 Watt, 2500 lumens luminaire fixture in IP 65/66 protection level with aluminum pressure die cast reflector with heat shrink LM 6, dedicated optics with precise light distribution SDMC not less than 5 uniform lighting quality and UV stabilized, output of LED lamp efficiency 100 luman per watt after all losses, driver with 4KV surge high and low voltage protection, power factor not less than 0.97, life of LED 50,000 burning hours and including suitable bracket made out of GI pipe 25mm/40 mm bore light grade (as per fitting bas dia) of approximate length 2mtr long bent to shape and fixed to wall with two Nos. MS clamps made out of 32 x 6mm thick flat with nuts, bolts and washers etc., including connecting up with 2 core 1.5 sqmm PVC insulated PVC sheathed weather proof multi stranded aluminium conductor cable 1100 volts grade upto junction box including painting of clamps with two coats of aluminium paint over a coat of approved primer all as specified and as directed. Make:-Havells, cat part No. ENDURACITYLINERNEX GENSL45W LED 757SASYBOPC or equivalent make of Philips Car Part No BRP409LED 065CWHEMRFG SI PSU GR / Wipro Cat Part No LR 02-501-XXX-57-XX
S & F MCB SP, 6 amps to 32 amps, 240 volts,10 KA complete all as specified and as directed by Engineer-in-Charge. Make: (i) Larsen & Tubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric
S & F MCB SPN, 40 amps, 240 volts,10 KA complete all as specified and as directed by Engineer-in-Charge. Make: (i) Larsen & Tubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric
S & F sheet metal enclosures, double door, for DBs when MCBs to be used, 240 volts, 8 way with 200 Amps rated bus bar,single pole and neutral, fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/ thimbles duly crimped for connection and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and directed by Engineer-in- Charge Make: (i) Larsen & Tubro (ii) Siemens (iii) Schneider (iv) ABB (v) Havells (vi) Legrand (vii) Indo ASIAN (viii) C & S Electric
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 meter including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 12 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
S & F five star rating ceiling fan 1200 mm sweep, 240 Volts, 50 Hz AC supply complete WHITE colour with 3 blades and all required accessories for fixing/hanging complete all as specified and as directed by the Engineer-in-charge. Make - Havells Cat Pt No ES-50 or Equivalent in CG/ORIENT/Khaitan complete all as specified and as directed.
S & F in trenches/wall/flooe etc LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly, IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 10 Sqmm 2 core including disconnecting /getting out old unserviceable cable piece complete all as specified and directed. Make- 1.Cable Corporation of India, Mumbai 2. Asian Cable Co, Chattisgarh 3. Finolex Cable Ltd, Pune 4. Polycab 5. Gloster 6. Universal 7. RPG Cables Ltd , Thane 8. Havells india ltd, Alwar 9. RR Kabel 10. KEI Industries Ltd(KEI)
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
M & L for sand for cushioning of cable in trenches for cable protection including spreading, levelling and hand punning complete all as specified in SSR part I and as directed by Engr-in-charge. NOTE-Thickness of sand cushioning sall be measured after punning and consolidating of sand.
M & L for laying unreinforced precast concrete cable covers class LV type flat size 250 mm x 150 mm x 40 mm, laid in trenches complete all as specified and directed by Engr-in-charge. Make- 1.Mehtab 2 Patel Furniture Mart 3 Topaz
S & F GI pipe, light grade, 40mm bore for cable protection on wall, trenches, road crossings etc. with suitable size of GI saddle, wherever necessary complete all as specified and as directed by Engr-in-Charge. Make- (a) Tata (b) Swastik (c) Jindal (d) Surya (e) Prakash (f) Indian Tube Company (g) Zenith (h) BST (j) GST (Gujrat Steel Tube)
Colaba Group Works
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .