| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.2 L+₹2.7 L (5.87%)Rejected-Finance FLAT NO 7 MHAMBRE BLDG DR FRANCISCO LUIS GOMES ROAD VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹50.8 L+₹4.4 L (9.46%)Rejected-Finance FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
17 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI BIJENDRA SHARMA IDSE EE
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802
8480/22/E8
2022_MES_553536_1
8480/22/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class D Category a i b i
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹98,000
Yes
5 Nov 2022
22 Sept 2022
19 Oct 2022
22 Sept 2022
17 Oct 2022
4 Oct 2022
22 Sept 2022 - 3 Oct 2022
60 days
Amount
PROVISION OF SOUND PROOF AIRCRAFT GROUND RUN POINTS FOR CONDUCTING HP GROUND RUNS FOR MIG 29K AT BSF GOA AT INS HANSA (B/R PORTION)
Material and Labour demoliton of cement Concrete in ground floors and pavings exc 15 cm thickness above ground floors and demolition procedure like cutting out of full depth of (100 to 450mm) existing damaged / shattered concrete slab with diamond wheel cutter or carbide tipped wheel saw to provide a pressure relief cut within the patch area prior to boundary sawing, in proper rectangular, square or triangular shape perimeter without disturbing adjacent slab, after the repair area is isolated by full - depth saw cuts, making small pieces, lift and removing the deteriorated concrete slab pieces from its position and removing to a distance exc 1.0 Km and not exceeding 5 Km complete all as specified.
Excavation in trenches not exc. 1.5 m in depth and not exc 1.5 m wide in soft disintegrated rock for foundation and getting out
Material and Labour for hardcore of broken stone gauge exc 63mm but n exc 100 mm , deposited, spread and leveled in layer n.exc 15cm thick, watered and rolled / rammed to a true surface under PCC Platform .
Returning, filling in with soft/disintegrated rocks, including spreading, levelling, watering and well ramming in layers not exc 25 cm
Removing excavated material n.exc. 50 m and depositing/spreeding where disrected at a level n.exc. 1.5 m above the starting point.
PCC type D2 1:4:8 (40mm aggregate) in foundations filling and mass concrete
Material and Labour RCC Type B1 1:2:4,20mm graded aggregate as in Foundations, including rafts,footings , foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Material and Labour RCC Type B1 1:2:4, 20mm graded aggregate as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material and Labour RCC Type B1 1:2:4, 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and Labour RCC Type B1 1:2:4, 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
Material and Labour Mild steel bars 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
Material and Labour Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Material and Labour Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified (Type C1,1:3:6)
Cement concrete work in pavement of flexural strength 45 Kg/Sqcm using minimum 400 Kg of cement/Cum as per design mix including mixing of non circular polyester fibre @ 1Kg/Cum all as per design mix laid and finished , however in narrow width & small turning fillets fixed steel form work of approved size shall be used with prior approval of GE complete all as specified and as directed by Engr-in-Charge. Note: (1) Supply of Polyester non-circular fibre as secondary reinforcement shall be measured and paid separately. (2) All joints shall be measured and paid separately. (3) In the event of increase in cement content as per design mix, nothing extra shall be admissible and quoted rates are deemed to be included for the same. (4) Finishing including brooming shall be carried out strictly as per laid down instructions
Supply only non circular synthetic fiber reinforcement all as manufacturer instructions complete all as specified and directed.
Material and Labour for forming dummy/contraction joints100mm deep and 8mm to 10mm wide at spacing not more than 4m c/c in 350mm concrete pavement and sealing the joints with polyurethene based sealant Seal N flex FC (grey colour) over a coat of N49 primer including bond breaker caulked tightly into the base of sealing groove complete all as per manufactures instructions up to 15mm deep and 8mm thick over 12mm dia polythene rod over 70mm depth bituminous filler board after priming the concrete sides with two coats of primer shall be applied with a thin brush by the forward and backward movement before pouring the sealent with primer of same make, complete all as specified. Note : (1) Edges of joints shall be rounded up by mechanical means at the time of final cutting. (2) Initial cutting shall be carried out within 24-36 hours of casting. (3) Final cutting, rounding of edges, use and waste of back up rod to avoid deposition of foregion materials in the joint upto final filling of joints shall be carried out after 28 days . (4) Applying masking tape on the edges of joint to prevent accidental slippage of sealant on top surfaces and to give a neat finish to the sealant and removing the masking tape after sealant is applied as required.
Material and Labour Rendering 15 mm thick cement plaster on concrete solid block walls in CM 1:4 finished to even & smooth w/o using extra cement.
Material and Labour Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid seperately.
Material and Labour Rendering 5 mm thick cement plaster on ceiling in CM 1:3 finished to even & smooth w/o using extra cement.
Material and Labour Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling.
Material and Labour Preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall
Material and Labour for preparation of plastered surfaces and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gMaterial and Labouritre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10Sqm all as specified and as directed.
Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid separately
Material and Labour for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Fillig the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalant) on prepared concrete/ plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixint Newcoat/ Waterseal Concentrate of M/s Krishna Conchem Products) withort any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completly. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
Supply only water proofing compound
Material and Labour 75 mm thick Cement concrete type C2, 1:3:6 (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing/ pavings/ plinth protections, etc.
M&L screed bed or bedding layer of mortar 15 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors /skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L rendering 10mm thick in cement plaster 1:6 on stone masonry surfaces or surfaces other than fair face of brick work to receive glazed tiles
M&L Granite 18-20 mm thick (of any type) work (table rubbed and polished) in horizontal steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S&F UPVC sound proof casement door (IDEAL 2000) of dimension 1.20 m x 2.10 m fitted with laminated toughened glass of thickness 14.76 mm, ESPAG handle type and necessary foam sealent with complete testing for 60 DbA ambient room noise complete all as specified and directed by Engr-in-charge
S&F UPVC sound proof Fixed window (IDEAL 2000) of dimension 2.40m x 1.20m fitted with laminated toughened glass of thickness 14.76 mm and necessary foam sealent with complete testing for 60 DbA ambient room noise complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing
Supply and Fixing lnsulated PVC Wall Lining consisting of PVC Insulated Panels having expanded polystyrene (EPS) stuck to 2mm thick single side prelam PVC sheet duly fitted into the wall as per specifications and drawing
Supply and Fixing 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make. The Tile & Grid system used together should carry a 10 year warranty all as directed by Engineer in Charge.
Supply and Fixing curtain rods along with designer holders at both sides of mild steel, chromium plated with fixing brackets
PROVISION OF SOUND PROOF AIRCRAFT GROUND RUN POINTS FOR CONDUCTING HP GROUND RUNS FOR MIG 29K AT BSF GOA AT INS HANSA. (E/M PORTION) INTERNAL ELECTRIFICATION
Material and Labour for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light/telephone point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 2.01 here in before, but for one fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No 2.01 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
Material and Labour for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm in width) ISI marked medium duty, with all accessories of same grade, fixed concealed in wall including provision of modular metal flush box, modular cover plate with frame top cover for housing mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Material and Labour for sub main wiring with two runs of single core 4 Sqmm FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non metallic rigid PVC conduit medium grade of as required size (not less than 20 mm in width) with all accessories such as Tees, elbows, junction boxes etc, as required fixed concealed in wall along with One run of 4 Sqmm single core FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, One run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
Supply and fixing modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
Supply and fixing modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
Supply and fixing modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
Supply and fixing modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 voltscomplete all as specified and as directed
Supply and fix Telephone socket with PVC box complete all as specified and directed
Supply and fixing Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
Supply and fixing 20/25 Amps motor starter switch with overload protection, ideal & safe for air conditioners, cooler, water pumps, refrigerators mixer, and all type of appliances Computers complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 20/25 Amp Power unit combo MCB Protected socket with top, ideal & safe for air conditioners, cooler, water pumps, refrigerators mixer, and all type of appliances Computers complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB DB TPN 4 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
Supply and fixing MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
Supply and fixing MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
Supply and fixing LED Aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos. LED are provided with necessary fixing arrangements & electrical connections complete all as specified and directed by Engineer-in-Charge.
Supply and fixing surface / receses mounting lights 2' x 2' LED flat panel 36 Watt, white powder coated CRCA housing with highpower LEDs, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip,connector block etc.and necessary fixing arrangement at any height complete all as specified and directed.
Supply and fix Building Security LED fitting 60 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED's and electronic driver, internally prewired including necessary fixing arrangement on Building by providing MS angle iron bracket of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed.
Supply and fix GI bracket pipe of size 32/40 mm dia medium grade of 1.5 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of street light fittings of any type and the GI bracket pipe shall be fixed on wall / pole surfaces by providing suitable MS flat iron 32x6 mm clamps 2 nos of 25 cm long duly to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts & washers and removing of old unserviceable item complete all as specified and directed
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts / bolts check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 35 Sq mm, 3.5 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland,clamps if required and jointed in any description complete all as specified.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable / errection of poles all as specified.
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level all as specified.
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish all as all as directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified.
Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point.all as specified.
Supplying & Laying in trenches Clear Sand/m- Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified.Note: Punned thickness only will be measured and paid.
Supplying & Laying precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches for protect to under ground cable complete all as specified.
Supply and fix or laying in trenches / on wall / poles / structures as in repairs GI tubing light grade for road crossing / for cable protection / fixing of pigmi lights etc,of the following sizes including necessary provision for cable entry if reqd in pigmi lights pole, fixing screws complete as required all as directed. (a ) 50 mm dia
LIGHTENING PROTECTION
Supply and fix single point air termination Copper rod, 12mm dia, 300mm long
Supply and fix copper strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip
Supply and fix tubes light grade with all fittings 25 mm dia fixed on the roof for Air termination including necessary well.
Material and Labour for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and directed by Engineer-in-Charge.
Galvanised base plate of size 100mm x100mmx 12mm rigid fixed on top roof height for mounting of 12 mm copper rod and connected item complete and insulated from base complete all as specified and directed by Engineer-in-Charge.
Material and Labour for PCC 1:3:6 Type C-I using 20 mm gradaed agrgate for PCC of size 0.2m x 0.2m x 0.2m cube with MS ferule for maounting GI pipe 40 mm Dia
SUMMER APPLIANCES
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity 2.0 TR .
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Supply and fix UPS for 30 min back up three phase AC input 300 to 450V and out put 415 V ± 1% of capacity 10 KVA
Material and Labour for Earthing complete with copper earth plate, electrode, 600 x 600 x 3.15 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to Copper strip size 32 x 3 mm thick dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chanber be 50 mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 32 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engineer-in-Charge.
Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity upto 20 KV
Supply and Fixing Pre painted galvatume aluminium Zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding fixed with self taping screws as specified.
Material and Labour steel work in tubular section, rolled section as columns, posts including welding to plates, angles forming bases for columns and brackets for sheds etc complete all as specified.
Material and Labour for two coats of synthetic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surfaces on steel surfaces.
Excavation in post holes in soft and loose soil n. exc 0.5 cum each and removing surplus soil to a diastance n exc 50m and making good surfaces etc complete all as specified and directed.
Cement concrete in foundation filling and mass concrete Type D-2 (1:4:8) 40mm graded agrregates etc complete all as specified and directed.
PROVISION OF 250 KVA SERVO CONTROLLED VOLTAGE STABLIZER FOR AIRCRAFT SERVICING AT INAS 310, AT INS HANSA
Supply install, test and commission cubicle type CPRI approved LT feeder piller box of size as per suitable size approved by Engr- in- charge/ GE mounted on floor/ wall pedestal factory made, totally enclosed, dust & vermin proof (protection class IP 54), (front opening) with propper locking arrangement made of MS angle iron frame size of 50mmx50mmx6mm with legs heights of 60cm and CRCA sheet of 3.15 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer. The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and shall be complete with internal wiring, thimbles glands and shall be complete all as specified as directed with the undermentioned accessories. Note:-The cost of the PCC pedestal is deemed to be included in the quoted rate of above item. The panel will comprise of the following :-
Supply and fix in repair changeover swithcs on load changeover switches 4 pole 400 Amps in sheet steel enclosure with inclosure, including necessary spreaders/cable lugs / gland / nut, bolt and washers if required complete all as specified and directed by Engineer-in-Charge.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 sq mm 3 1/2 core.
Supply and lay Double walled corrugated pipe (DWC ) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
Supply and Fixing LT heat shrinkable indoor cable Jointing kit, complete with jointing material and accessories suitable for 3.5 core XLPE armoured Aluminium conductor cable of size 300 Sqmm complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-Charge.
PROVISION OF EARTHING STRIP CONNECTION TO TEST BENCHES IN AVIONICS BUILDING (P-98) AT ALD INS HANSA UNDER AGE B/R-I AND AGE EM-I OF GE (NW) VASCO.
Material and Labour for Earth continuity conductor or main earthing lead copper strip of size 20x3mm fixed to wall on insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to wall or any other indicated situation for loop earthing etc complete all as specified.
Supply and fixing of epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc.
Supply and fix Rigid non-metallic PVC conduit 40 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.
Material and Labour for Chemical earthing with one No of copper earth plate of size 900 x 600 x 5 mm & copper earth strip 32 x 6 mm buried in ground vertically to a depth not less than 3.0 metre below ground level with top edge earth electrode at a depth not less than 2.40 metre deep below ground level including suitable quantity of backfill chemical compound for filling in each pit to cover earth electrode minimum 100 mm all around and electrode shall be jointed with the copper strip of size 32 x 6 mm by exhothermic weld complete with earth pit chamber of size 300 x300 mm and RCC cover for demarking the location of earth electrode location. Note for item 4.04:- (i) The quantity of Backfill compound and depth of earth pit can be increased by the contractor without any extra cost to Govt. The Contractor shall ensure that earth resisitance shall be less than 1 ohms on completion and testing. The testing of each earthing shall be carried out in presence of Engineer-in-Charge and test results shall be submitted duly signed by all concerned while claiming payments. (ii) Earth strip with protection pipe 50mm GI light grade upto 7.5 meter is deemed to be included in the rates quoted.
Supply and fix PVC insulated multistranded copper conductor cable 70 Sqmm single core 1100 volts grade including copper lugs/thimbles on both side fixed from common Earth point grounding pit including nuts, bolts, washers and connect to test benches with copper lugs complete all as specified and as directed by Engineer-in-Charge.
M/s J.D. DESAI
M/S jvsr constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .