Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC VILL BALIPOTA P O NARAJOLE P S DASPUR DIST PASCHIM MEDINIPUR PIN 721211 WEST BENGAL | NARAJOLE | PASCHIM MEDINIPUR | WEST BENGAL | 721211 | ₹4.5 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹5.2 L+₹74,878.41 (16.7%)Rejected-Finance | ₹5.2 L+₹74,878.41 (16.7%) | L2 | Rejected-Finance Being L2 Bidder |
| 3 | L3₹5.3 L+₹78,960.33 (17.6%)Rejected-Finance | ₹5.3 L+₹78,960.33 (17.6%) | L3 | Rejected-Finance Being L3 Bidder |
| Sl No | Description | Qty | Unit | NEW MODERN COOLING L2 | EFFORTECH L1 | M/S SAMRIDDHI ELECTRO & CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch of grey/black colour (Brand approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish with following average run. [only PVC Rigid Conduit on ceiling and remaining portion concealed] | - | - | - | - | - |
| 1.10 | 6 Mtr. [ 4(b) / E- 25 ] | 17 | Pt | 851 ₹14,467 | 893 ₹15,181 | 825 ₹14,025 Lowest |
| 2.00 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish as per GS. | - | - | - | - | - |
| 2.10 | On Board [ 3(I) / E- 20 ] | 1 | Pt | 290 ₹290 | 254 ₹254 Lowest | 255 ₹255 |
| 3.00 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works as per GS. | - | - | - | - | - |
| 3.10 | 4 module [1(a)/E-17] | 3 | Nos. | 281 ₹843 | 263 ₹789 | 261 ₹783 Lowest |
| 3.20 | 6 module [1(b)/E-17] | 2 | Nos. | 375 ₹750 | 339 ₹678 | 332 ₹664 Lowest |
| 4.00 | Supplying & Fixing modular type switch /socket ( Brand approved by E.I.C), in exsisting Modular board incl. connections. | - | - | - | - | - |
| 4.10 | 16 A modular type socket [4(b)/E-17] | 5 | Nos. | 185 ₹925 | 165 ₹825 | 162 ₹810 Lowest |
| 4.20 | 16 A modular type switch [3(b)/E-17] | 5 | Nos. | 153 ₹765 | 121 ₹605 | 119 ₹595 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
5 Jun 2023, 2:00 pmClosed
The Executive Engineer, PWD, Hooghly Ele
Office of The Executive Engineer, PWD, Hooghly Electrical Division , Purta Bhavan 3rd Floor , Sarat Sarani , Kodalia , Hooghly
SITC of one number Fully automatic type 15 persons capacity 1020 kg load Bed cum passenger lift for building at P.C.S Govt. Medical College _ Hospital Arambagh in the district of Hooghly__EI Works.
2023_WBPWD_532991_1
WBPWD/EE/ HED / NIeT-04/2ND CALL 2023-24
Open Tender
Electrical Work/ Equipment
Item Rate
30 days
HOOGHLY
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
Yes
Office of The Executive Engineer, PWD, Hooghly Ele
14 Sept 2026
22 May 2023
8 Jun 2023
22 May 2023
5 Jun 2023
22 May 2023
26 May 2023
Amount
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch of grey/black colour (Brand approved by E.I.C) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish with following average run. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
6 Mtr. [ 4(b) / E- 25 ]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish as per GS.
On Board [ 3(I) / E- 20 ]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works as per GS.
4 module [1(a)/E-17]
6 module [1(b)/E-17]
Supplying & Fixing modular type switch /socket ( Brand approved by E.I.C), in exsisting Modular board incl. connections.
16 A modular type socket [4(b)/E-17]
16 A modular type switch [3(b)/E-17]
6 A 5-pin modular type three pin socket [4(a)/E-17]
6 A modular type switch [3(a)/E-17]
Blanking Plate
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick [ 3 (a)/ E- 2 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works [ 7/E-16]
a) 20mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ]
4x35 Sqmm [NS]
Supplying & Fixing sheet metal inspection box (16 SWG) with perspex/bakelite cover (3mmthk)of the following sizes(in mm ) flushed in wall as per GS
150 x 100 x 65 [11(a)+13(a)/E-4]
200 x 150 x 65 [11(a)+13(a)/E-4]
S&F double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS.
4 Way, Up to 160A [15/D-11]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing DBs / enclosure and necessary connection- LEGRAND 4P 80A [10/D-8]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.
2+8 Way. [ 13 / D- 9 & D-10 ]
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment as per GS.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand/ Schneider/Siemens/ Crabtree/ L&T) as per direction of EIC. ]
S&F 20/18W LED T-8 lamp with polycarbonate diffuser and metal heat sink as per direction of EIC. [Make: Crompton, Model: LTB-20-865-(2) or Equivelent model of Phillips/Magik ]. [NS] [With 3 years on site warrenty]
Supply of Dual 4ft LED box type batten complete with all accessories as per direction of EIC. [ Make: Crompton, Model: IGP162LT8-162 x T8 or Equivelent model of Phillips/Magik ]. [NS] [With 3 years on site warrenty]
S & F 9 watt LED Lamps with bayonet cap (B22) [NS]
Supply of 240V, 100W LED street light with IP65 protection complete with all accessories ( Make: Crompton, Model LSTP-100-CDL-M of equivelent model of Phillips/Magik) as per direction of EIC. [With 3 years on site warrenty]
Supplying & Fixing bulk head light fitting (Model: LBHE-10-CDL) with die cast aluminium housing & IP65 Protection as per direction of EIC. (Make: Crompton/Phillips/Magik) [NS]
Fixing only single/twin fluorescent light fitting in the ceiling fixed with “L” type MS clamp as per GS [ 17/C-2 ]
Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [22/D-13]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter as per GS
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat ironframe & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
Fixing only cabin/Wall fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length as per GS.
Supply of 450mm sweep High Thrust wall fan(high speed) with metal body, canopy & blades(Orient - Wall AC18 or equivalent model of CG/EPC/Cinni) with necessary nuts, bolts, washer etc. as per direction of EIC. [NS]
Supply of 12"( 300mm ) Speed 920 RPM Exhaust fans complete with all accessories as per direction of EIC. ( Make -EPC heavy duty ) [ NS ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5sqmm [9 (i)/F-5]
4 sqmm [9 (ii)/F-5]
6 sqmm [9 (iii)/F-5]
35 sqmm [9 (iii)/F-5]
Supply of 4 Core 50 Sqmm XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make: Gloster/KEI/Havells]
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting as per GS. [ 2(c)/ F- 1 ]
Supplying and fixing compression type gland and finishing those for following XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS.
4Core 50 Sq. mm [7(c)/F4 & 8(b) (xvi)/F5]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1]
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [5(a)(i)/G-2]
No.-10 SWG [5(a)(iv)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS [4(a)/G-2]
Supplying and fixing 415V, 100A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating as per GS. [Make: Seimens/ L&T] [4(a)/D-3]
Supplying and fixing 415V, 100A TPN SFU open execution in existing SS enclosure/ cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating as per GS. [Make: Seimens/ L&T] [4(b)/D-3]
Supply & Fixing of daily weekly programmable electronic 240v, 16A, 50 Hz analog time switch ( Make:- Legrand, Model:-412812) on suitalbe size hylum sheet including necessary connections as per direction of EIC. [NS]
S & F MS of 450mm x 200mm x 100 mm Loop box (16SWG) incorporated with 1 no 315A 4W Brass stud on porcelain chair incl S & F MS cover, making holes for 1no cable in & out position, painting, to be fixed in conceal in wall as per direction of EIC. [NS]
Supply of LED Tube illuminated sign board fabricated by 3'(L)x2'(H)x6"(W) ACP box supported with 20 x 20 x 3 mm M.S. Angle structure all around with 40mm x40mmx 1.62 mm Al. edge angle for front portion only.The back side of the cover will be fabricated with hinges and arrangement in such a way so that it can be opened for maintenance purpose, including mechanical locking arrangement .The 3 mm ACP facial (Blue colour) should be provided with laser cutting of 6 mm laser cut Acrylic letters out of which 5 mm rising and back portion of the ACP board should be pasted with 2mm thick Clear Acrylic Sheet of same size as ACP facial as per the direction of EIC.The sign board should be illuminated LED lamps (6 nos.) (LED lamp 12 W ) with batten to be fixed by hooking arrangement with iron stucture fabricated for fixing purpose. Distribution wiring for power supply to LED fittings to be done by PVC rigid conduit, necessary clamps, cable tie etc. Back side of the of the board should be covered with 20 SWG G.I. sheet to protect rain water. The matter to be displayed will be finalised by authority and to be given later.This fabricated display structure is to be fixed on the top of prefabricated iron structure as per direction of EIC.
S & making fron facia of lift lobby by S&F Ceramic tiles With Sand Cement Mortar (1:3) & cement slurry at back side of tiles using cement match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. [Approximate Area=40 Sqmtr (Existing and new provisions), Ref.: PWD Sch. item Sl no 35 page 64]
Cost of one coat White washing including cleaning and smoothening surface thoroughly inside the existing lift shaft as per direction of EIC. [Approximate Area=140 Sqmtr, Ref.: PWD Sch. item Sl no 01 page 194]
Making arrangement of one set of scaffolding for painting the lift shaft as per direction of EIC.
Supply of Digital Clamp meter measure AC current 1000A (Make: CIE, Model: DCM2350) as per direction of EIC.
Supply of Non-contact Infrared Thermometer for up to 800°C with a unique Circular laser indicator (Make: Metravi Model: Pro 65 Max) as per direction of EIC.
Supply of 800W, 16000 R.P.M heavy duty air blower with dust extraction (Make: Bosch, Model:GBL 800 E ) as per direction of EIC.
Add GST @18% Rs.
Add LWC @1%
NEW MODERN COOLING
M/S SAMRIDDHI ELECTRO & CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .