| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 CrAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹3.7 Cr Quoted ₹3.8 Cr | L1 | Accepted-AOC Found reasonable |
| 2 | L2₹3.8 Cr+₹65,100 (0.17%)Rejected-Finance | ₹3.8 Cr+₹65,100 (0.17%) | L2 | Rejected-Finance Other Than Lowest |
| 3 | L3₹4.0 Cr+₹20.8 L (5.52%)Rejected-Finance | ₹4.0 Cr+₹20.8 L (5.52%) | L3 | Rejected-Finance Other Than Lowest |
| 4 | L4₹4.0 Cr+₹26.5 L (7.03%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹4.0 Cr+₹26.5 L (7.03%) | L4 | Rejected-Finance Other Than Lowest |
| 5 | L5₹4.2 Cr+₹38.2 L (10.1%)Rejected-Finance 5037 5038 URBAN ESTATE PH 1 PATIALA 147002 PUNJAB | PATIALA | PATIALA | PUNJAB | 147002 | ₹4.2 Cr+₹38.2 L (10.1%) | L5 | Rejected-Finance Other Than Lowest |
Tender Value
Refer Docs
EMD Value
₹5.4 L
Closing Date
5 Jun 2021, 6:00 pmClosed
CE Lucknow Zone
HQ CE Lucknow Zone, 17, cariappa marg, Lucknow 226002
IMPROVEMENT AND RESTORATION OF ELECT DISTRIBUTION NETWORK AT AGRA MIL STATION
2021_MES_439435_1
CA NO. CELZ/AGR/T-20 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AGRA
As per tender Documents
7 documents required · 7 mandatory
₹3,000
Yes
GE(EAST) AGRA
₹5.4 L
Yes
31 Aug 2021
30 Apr 2021
7 Jun 2021
30 Apr 2021
5 Jun 2021
29 May 2021
Amount
Excavation in trenches, in any type of soil n.exc 1.5 M wide and n. exceeding 1.5 M in depth for foundation/ cable laying etc and getting out including forming bottom surfaces to required level or slope including removing of cable cover bricks for relaying complete all as specified and directed.
Excavation in trenches, in any type of soil n.exc 1.5 M wide and exceeding 1.5 M but not exceeding 3.0m in depth for pole foundation/ cable laying etc and getting out including forming bottom surfaces to required level or slope including removing of cable cover bricks for relaying complete all as specified and directed.
Returning, filling in, excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed.
M&L for Sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. Note: - Only punned thickness shall be measured.
M&L for unreinforced pre cast concrete cable cover comply with IS 5820:1970 and shall be of class HV type -I, flat size 300x180x40mm laid dry in trenches for the protection of underground cable complete all as specified and directed.
M&L for bricks covering width equal to length of brick for mechanical protection to cable with well burnt sub class 'B' bricks laid dry flat complete all as specified and directed.
M & L for PCC 1:3:6 cement concrete ( Type C-1 ) using 20 mm graded aggregate in foundations, filling and mass-concrete as in path etc complete all as specified and directed.
M & L for PCC 1:2:4 cement concrete ( Type B-1 ) using 20 mm graded aggregate in foundations, filling and mass-concrete for coping , in path etc complete all as specified and directed.
M&L for horizontal boring and inserting casing pipe with fittings with material HDPE 100mm /150mm bore of pressure rating 6 kg/cm² along road and under pavements/ hard standing/ railway/ road /canals /streams crossing in all types of soil at prescribed depth (in no case the depth of boring be less than 1.7 m from the road surface for passing of HT cable including all civil works & reinstatement as per BMP standards complete all as specified and directed. Note : (i) if any damages to existing services such as OFC/gas pipe line/electric cable etc shall be repaired immediatelly by the contactor. Rate quoted above deemed to be included. (ii) Cost of equipments ,T&P (Horizontal boring rig machine ) required for above job is deemed to be included in the quoted rate
Supplying and laying GI tubing light grade ISI marked confirming to IS for encasing HT cables for mechanical protection, laid under plinths/floors/roads/paths/culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps of size 50x6mm with necessary bolts nuts and washers etc of size 100mm dia complete all as specified and directed.
All as per item No 11 but 80mm dia bore
All as per item No 11 but 40mm dia bore
All as per item No 11 but 15mm dia bore
Supply and laying 11 KV (Earthed) , aluminium conductor, screened, XLPE insulated , armoured triple entruded with dry nitrogen cured and PVC sheathed cables ISI marked, IS 7098 (Part-II) amended upto date , cross sectional area 120 Sqmm, 3 Core complete all as specified and directed.
Supply and laying 11 KV (Earthed) , aluminium conductor, screened, XLPE insulated , armoured triple entruded with dry nitrogen cured and PVC sheathed cables ISI marked, IS 7098 (Part-II) amended upto date , cross sectional area 95 Sqmm, 3 Core complete all as specified and directed.
Supply, jointing and testing indoor type cold shrinkable end terminal cable joint including all materials and accessories suitable for 3 core x 95 / 120 sqmm XLPE armoured aluminium conductor cable of 11 kV grade all as per manufacturers recommendation complete all as specified and directed.
Supply, jointing and testing outdoor type cold shrinkable end terminal cable joint including all materials and accessories suitable for 3 core x 95 / 120 sqmm XLPE armoured aluminium conductor cable of 11 kV grade all as per manufacturers recommendation complete all as specified and directed.
Supply, jointing and testing straight through cold shrinkable joint including all materials and accessories suitable for 3 core x 95 / 120 sqmm XLPE armoured/AB cable aluminium conductor cable of 11000 Volt grade all as per manufacturers recommendation complete all as specified and directed.
Supply, installation testing & commissioning of HT 11 KV, 400A, VCB( Vaccum circuit braker, indoor type totally enclosed, free standing floor mounting type, compartment based with trunk mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used.back entry type complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and protective and control devices as per details mentioned in Annexure - A to BOQ. NOTE :- (i) Annexure- A to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 04 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-03 Nos and Vacuum Circuit Breakers-01 No. along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - B to BOQ. NOTE :- (i) Annexure- B to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 03 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-02 Nos and Vacuum Circuit Breakers-01 No. along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - C to BOQ. NOTE :- (i) Annexure- C to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order. .
Supply,installation,testing & commissioning of 11 KV Outdoor type 05 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-02 Nos and Vacuum Circuit Breakers-03 Nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - D to BOQ. NOTE :- (i) Annexure- D to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 04 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-02 Nos and Vacuum Circuit Breakers-02 Nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - E to BOQ. NOTE :- (i) Annexure- E to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 03 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-01 Nos and Vacuum Circuit Breakers-02 Nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessoriesas per details mentioned in Annexure - F to BOQ. NOTE :- (i) Annexure- F to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 03 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-03 Nos along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories such as per details mentioned in Annexure - G to BOQ. NOTE :- (i) Annexure- G to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 05 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-03 Nos and Vacuum Circuit Breakers-02 Nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - H to BOQ. NOTE :- (i) Annexure- H to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 05 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-04 Nos and Vacuum Circuit Breakers-01 No. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - I to BOQ. NOTE :- (i) Annexure- I to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply,installation,testing & commissioning of 11 KV Outdoor type 04 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-01 No and Vacuum Circuit Breakers-03 Nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & scaled for life , robotically for three sides and one side manual welded non magnetic/non ferrite /stainless steel tank Grade 304 of minimum 2 mm thick having IP 67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376, 60376 &603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for case of installation. RMU should be complete with all accessories as per details mentioned in Annexure - J to BOQ. NOTE :- (i) Annexure-J to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply, installation, testing and commissioning of SF 6 CIRCUIT BREAKER 400 Amps ( Out door ), 12 kV, 50 Hz, lightning impulse 75 KV peak ( outdoor type ) with IP 54 protection SF 6 insulated compact switch gear equipped according to international standered ICE 62271-200 intensive to environmental conditions in compact verson with stainless steel tank and comprising, 400 amps LOAD BREAK SWITCH and protective relays for adjustable relay to protect transformer upto 200 to 615 KVA alongwith compact battery , cable termination from the front of side/back side, breaking capacity min 20/21 kA/3 sec enclseod in metallised cast resin/stainless steel enclosure, complete all as specified and tested as per latest IEC rules 62271-200 complete all as specified and directed..
Disconnecting carefully and shifting of Transformer 11KV/415 volt, 200/250 KVA to new location using necessary T&P and making connections electrically and mechanically to make it functional complete including fabrication of foundation and platform with step of size 2.0 mtr x 2.0 mtr x 1.5 mtr height made out of brick construction including excavation, PCC and rendering etc as per existing pattern complete all as per drawing No TD-699 sheet 1/1 and related TD drgs and dismentling existing plateform etc complete all as specified and directed.
Supply installation, commissioning and testing of transformer copper wound step down 250 KVA out door type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed air naturally cooled (ONAN Type), BEE rating of EEL 3 , with external cooling tubes/radiators, Double wound core type copper wound having no load voltage ratio 11 KV/415 Volts corresponding to principal tapping,delta connected primary side (HV Side) and star connected on secondary side (LV Side) in accordance with vector symbol DYN 11 (Vector group-4) with neutral brought out on LV side and having tapping on HV side for constant out put so as to altervary secondary voltage from ± 2 ½ %, ± 5% and ± 7 ½ % in step to be changed by mean of manual off load tap changing arrangements complete confirming to IS-1180 Pt-I 2014 all as specified. The transformer shall be complete with following fittings and acessories as per details mentioned in Annexure - K to BOQ. NOTE :- (i) Annexure- K to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
M&L for Cable route/path indicator made out of 40 x 40 x 4 mm angle iron, 1 mtr long and plate of size 100 x 150 x 6 mm welded only on one side end having embosed on plate as "cable HT/LT" including PCC of size 30 cm x 30 cm x 30 cm duly embedded the angle iron with and including excavation, earth works and painting the yellow colour above the ground and write with the black colour complete all as specified and directed.
Supply, installation, testing and commissioning outdoor type cubicl panel board for 3 phases, 4 wire, design verified as per IS/IEC 61439-182 for 415 volts, 50 Hz rated fault level 65 KA with internal arc containment with IP 54 protection rupturing capacity at 415 volts, factory made in an approved factory having seven tank treatment process for powder coating with thickness not less than 60 microns with paint shade RAL-7035 provided with suitable gasket to make it dust / vermin proof & general construction comprising of the following as per details mentioned in Annexure -L to BOQ. NOTE :- (i) Annexure- L to BOQ has been uploaded separately alongwith tender documents and is part of BOQ for all purposes. (ii) Drawing should be approved by GE before placing the order.
Supply and laying in trench/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade, ISI marked, IS:7098 ( Pt I) with stranded aluminium conductor of size 400 sq mm 3.5 core complete all as specified and directed
Description all as per item No 35 above but 240 Sqmm 3.5 Core
Description all as per item No 35 above but 185 Sqmm 3.5 Core
Description all as per item No 35 above but 120 Sqmm 3.5 Core
Description all as per item No 35 above but 95 Sqmm 3.5 Core
Description all as per item No 35 above but 50 Sqmm 3.5 Core
Description all as per item No 35 above but 35 Sqmm 3.5 Core
Description all as per item No 35 above but 16 Sqmm 4 Core
Supply and fixing in replacement busbar chamber capacity 200 amps, 4 way, 4 pole, 50 Hz, 415 volts, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars complete all as specified and directed.
Supply and fixing in replacement busbar chamber capacity 315 amps, 4 way, 4 pole, 50 Hz, 415 volts, on wall /pole/panel with proper lugs having 4 Nos of copper bus bars complete all as specified and directed.
Supply and fixing MCCB 160 amps ,4Pole , 50Hz, Icu=16 KA at 415 volts, with thermal magnetic release alongwith adjustable magnetic protectionfor current setting Icu= Ics=100% with adjustable over load setting (minimum 70% to 100%) adjustable magnetic protection for current setting value from 10 to 15 times of rated current as per IEC-60947-1 and 60947-2 standerd with MS sheet metal enclousre complete all as specified and directed.
Supply and fixing MCCB 100 amps ,4Pole , 50Hz, Icu=16 KA at 415 volts, with thermal magnetic release alongwith adjustable magnetic protectionfor current setting Icu= Ics=100% with adjustable over load setting (minimum 70% to 100%) adjustable magnetic protection for current setting value from 10 to 15 times of rated current as per IEC-60947-1 and 60947-2 standerd with MS sheet metal enclousre complete all as specified and directed.
M&L for earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanized iron wire 4mm mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 25 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Note:- (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperatly. (iii) Test result should be as per IS.
M&L for earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level) vertically, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to galvanized iron strip 25x4mm dia by means of nuts, bolts, washers of GI steel all as shown on electrical plate No 3 of MES Schedule Part I connected to earthing test point and testing on completion with and including necessary excavation and earth work, earth electrode, earthing lead from electrode to equipment/substation, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover, reinforced with 6mm dia bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 50 mm dia GI light grade earth lead protection pipe, complete all as specified and directed. Note:- (i) Main earthing lead from earth plate electrode to test point upto length of 7.50 mtr shall deem to be included in the unit rate quoted by the tenderer against this item. (ii) GI protection pipe and earthing strip beyond 7.5 mtr long shall be measured and paid seperatly. (iii) Test result should be as per IS.
Supply and fixing Earth continuity conductor or main earthing lead 25x4 mm galvanised iron strip beyond 7.5 mtr complete all as specified and directed.
Supply and fixing Earth continuity conductor or main earthing lead 4 mm galvanised iron wire beyond 7.5 mtr complete all as specified and directed.
Supply and erecting Steel tubular swaged pole complete with cast iron base plate, finial taper plug , bolts , nuts & screws as specified type 410 SP-55, 11 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supplying ,fixing danger notice board of 1.6 mm thick mild steel sheet , viterous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed.
Supply and erecting Steel tubular swaged pole ( swan neck ) complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 of 9 mtr long, complete all as specified and shown on drawings including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (b) PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including form work complete. (c) PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete. (d) PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in base. (e) Painting of poles externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coat of aluminium paint over one coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 3 Nos with synthetic enamel paint of appropriate colour in alternate layer upto height of 1.5 m above plinth block. (f) Painting of coping shall be cement base paint complete all as directed. (g) Embeded portion shall be painted with two coat of black bituminous paint complete all as specified and directed. Note:- (i) This item consists of provision of steel pole and work mentioned in para (a) to (g) only. All other connected work, shall be measured and paid separately.
Supply and fixing sheet moulding compound(SMC) junction box for and including three phase and neutral bus bar and MCB SPN 06 Amps, 250 Volts 50 Hz, 15 KA for control of sreet lights mounted on ploe with the provisions of cable entry and exit Make Sintex/hensel cat part No KF8350/L&T product code NO GSJB-2817 of size 280mmX170mmX130mm all as specified and directed .
S & F of street light switch using timer for automatic switching of street light based on LUX level of natural light , The sensor along with suitable power contactor MCB support terminal shell be housed in enclosure made out of anti rust/ shock proof/ termite proof/ confirming to IP54 suitable for 5 KW load three phase .
Supply and Fix twin core aluminium conductor 2.5 sqmm PVC insulated , sheathed wire drawn in pole from juction box to street light and including provn of holes in existing pole wherever required complete all as specified and directed.
Supply and fix on pole LED security light 40 watt with aluminium pressure die cast housing , high purity PC Fresnel diffuser with silicon gaskets for IP-65 protection, power consumption < 40W & luminaire lumen > 2500lm and system efficiency > 100lm/W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm, LED Make:- Nichia/ Cree/Osram, CRI>70, ambient temperature range 0-450C, THD<10%, colour temperature 5700K, surge protection in CM-3.5KV, 50000 burning hours as per L70 criteria, multistage constant current-constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level < 60V DC as per IEC Standard all as specified and directed. Make:- Wipro Cat Part No. LR02-291-XXX-57-XX or techocommercially equivalent of makes as mentioned in Appendix "D"
M&L for cross arms, bracings, supports, clamps and back plates, anti climb device etc fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide and two coats of aluminum paint, complete all as specified
Supply and fix cable jointing kit ( heat shrink type ) suitable for 1100 Volts grade XLPE armoured cable for outdoor termination complete with jointing material and accessories for jointing purpose for 3.5 core cable of sizes 16 sqmm to 35 sqmm.
All as per item No 59 above but for 50 sqmm to 95 sqmm
All as per item No 59 above but for 120 sqmm to 240 sqmm
All as per item No 59 above but for 400 sqmm
Supply, installation, commissioning of HT 11 KV , 3-Phase outdoor gang operated air break switch(Isolator), ISI Marked, CPRI tested, factory assembled, mechanically operated , mounted on insulators and steel frame suitable for 2-Pole, Horizontal or Vertical mounting fixed type complete with nine numbers of porcelain insulators( Three post insulators per pole) with bottom MS channel of adequate dimensions and strength, self lubricating central bush bearing , copper contacts made of ETP grade high conductivity copper and spring loaded for adequate contact pressure, duly plated to improve resistance to corrosion, All MS plate and hardware to be duly hot dip galvanized, with tin plated copper wire of adequate cross sections , operating mechanism through an insulated operating mechanism worked from ground level and mechanical locking facility, Rated Voltage-12 KV, Rated Continuous current-200 Amps, 3 Ploe, Rated frequency-50Hz, Power frequency withstand voltage across the isolating distance-32KV, Power frequency withstand voltage to Earth-28KV, Lightning Voltage withstand test across isolating distance-85KV Peak, Lightning voltage withstand test across phase to earth-75 KV, Rated short time & Peak withstand current-20KA, complete all as specified.
Supply and fixing Single pole , 9 KV, horn gap non linear metal oxide resistance surge lighteing arrester as per IS-3070 ( Part I)1985suitable for working voltage of 11 KV with rated system voltage of 12 KV, out door type, maximum continuos operating voltage not less than 7.65 KV (rms), nominal discharge current 10KA(peak), power frequency reference lot less than MCOV, max residual voltage for discharge current of 10 KA and 8/20 micro sec-current wave- 40 KVp, long duration discharge class-II( as per IEC), pressure relief class/current-A/40KA,28/75 KV insulation level, 29.9 KV switching residual discharge loltage, 100 KA9peak) and 25mm/KV minimum creaping distance of highest system voltagewith all fittings, complete all as specified and directed.
Laying only in trench/pipe/on wall and connection and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm to 120 sqmm sq mm 3.5 core complete all as specified and directed Note :- Cable obtained from taking down shall be reused under this item and necessary transportation a shall be deemed to be included in quoted rate
All as per item No 65 here-in-before but HT UG cable 120 sq mm 3 core complete all as specified and directed Note :- Cable obtained from taking down shall be reused under this item and necessary transportation etc shall be deemed to be included in quoted rate
M&L of stainless steel hollow section framed to hang and fixing of sign board as per site requirement with and including all fitting and fixture at site for fixing of retro- reflective sheet complete all as specified and directed.
M & L for Glow sign board on retro reflective sheet as per IRC-67 1977 made of encapsulated lence type reflective sheet with back ground of any colour as directed, self illuminated depicting single line schematic diagram of the installation for any other specified matter duly marked as directed by Engr in charge. Note :- The frame work made out of stainless steel of glow sign board shall be measured and paid separately under respective item of BOQ
Taking down ACSR Conductor any size from HT/LT over head line complete all as specified and directed.
Taking out carefully HTUG cable upto 120 sqmm from pole/trench etc and staking in safe custody including maggering/testing complete for re-laying/re use complete all as specified and directed.
Dismentling /Taking out un-servisible HT steel pole 11 mtr long complete including dismentling PCC, earth work etc and making good the surface to match with existing complete all as specified.
Taking out un-servisible HT GOD any type/pattern from pole complete.
Taking out un-servisible LA any type/pattern from pole complete.
Taking out MS work any type/size, GI wire etc or Scrap iron
Taking out Old un-servisible Stay assebly any type/pattern complete including dismentling PCC, earth work etc and making good the surface to match with existing complete all as specified.
M/s DN Gupta and Company
LUMOS INFRA PVT LTD
Leo Air and Power Solution pvt Ltd.
Sant Construction Co.
M/s Prem Associates
GUPTA ENGINEERING WORKS
Bhanwariya Infra Projects Pvt Ltd
GEPS PROJECTS
VEE SONS BUILDERS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .