Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.8 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC L1 | |
| 2 | l2₹6.8 L+₹76,177 (12.6%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | l2 | Rejected-Finance l2 | |
| 3 | L3₹6.9 L+₹84,077.22 (13.9%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.1 L+₹1.0 L (16.8%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
10 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Kanasar
Assistant Garrison Engineer (I) Kanasar Military Station Kanasar, Bikaner (Rajasthan)
Repair/Maintenance of LED flame proof light fittings, DBs,switches and connected works at Mil Stn Kanasar
2023_MES_606648_1
CA NO. AGE (I) KNS/Token No. 20/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE(I) Kanasar
Contractor shall be enlisted with MES in Class E and above and category b(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Work Load Return (WLR) of any other report circulated by competent engineer
8 documents required · 8 mandatory
₹500
ASSISTANT GARRISON ENGINEER (I) KANASAR
₹16,000
Yes
2 Nov 2023
29 Jun 2023
15 Aug 2023
29 Jun 2023
10 Aug 2023
27 Jul 2023
6 Jul 2023 - 20 Jul 2023
Amount
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 400 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 120 Watt, CMRI certified well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. Make : Shyam/Sudhir or equivalent.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 70 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED Bulk head light fitting of 45 Watt/50Watt, CMRI certified fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 65 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver, efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified and directed. Make :- Shyam/Sudhir or equivalent
.M & L for taking down of old Flame proof Fluroscent Emergency lights of capacity 10 to 20 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED Emergency light fitting of 10 to 20Watt, CMRI certified fitting including LED lamps, with battery back up 2 to 3 hours as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA & IIIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 65 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver, efficiency more than 85 % along with surge protector with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified and directed. Make :- Shyam/Sudhir or equivalent
M & L for taking down of Flame proof 4 feet tubelight light fitting of capacity 36W/ 40W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc , making necessary modification / bypass arrangement for fitting of LED 20 Watt T8 retrofit fitting complete including replacement of old flurocent lamp holder / bipin holder G13 push type by new G13 push holder on both side and Supply, fixing in replacement and testing new 4 feet LED 20Watt lamp, T8 retrofit, two pin on both side, including driver length 4 feet operating voltage range 220-240 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver ,CCT 6500K, frosted glass having as per IS-16102-1 (2012) with latest amendments and input voltage, P.F should be more than 0.9 with total harmonic distortion (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification /replacement, re fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
M & L for taking down of Flame proof Bulk head light fitting of capacity 24W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc, making necessary modification for fitting of LED bulb of capacity 12W including replacement of B22 type bulb holder by new one batten bulb holder and Supply, fixing in replacement and testing old lamp by new LED lamp of capacity 12W, base B22, including driver operating voltage range 140 V-270 V, AC, frequency 50 Hz, CRI> 80%, , inbuilt surge protection and SMPS based driver , CCT 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage. P.F should be more than 0.9 with total harmonic distortions (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º C and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification / replacement , re-fixing the same Flame proof Bulk head fitting on original place and position etc complete all as specified & as directed.
M & L for taking down of Flame proof 2 feet / 2.5 feet tubelight light fitting of capacity 36W installed on wall / roof and opening the fitting cover / bottom by removing of nut / bolts / screws, making necessary modification for fitting of LED PL-L light of capacity 18 Watt including replacement of old florescent PL light type light holder by new 2G11 type holder and Supply, fixing in replacement and testing new LED PL-L lamp of capacity 18W base 2G11 , four pin, length 419 mm, width 44 mm, height 29 mm, operating voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver , CCT 6500K , frosted glass as per IS-16102-1 (2012), light colour warm white 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage P.F should be more than 0.9 with total harmonic distoration (THD) less than 10%, cool white colour and LED lamps hould be suitable for ambient temperature from -10ºC to 45ºC and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 130 lumens per watt and must be certified by the LM-79 test report. After modification/ replacement, re-fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
Supply, fixing in replacement and testing Flame Proof LED light fitting 1 x 20 Watt including LED lamp/tube complete, CMRI certified suitable for fixation on wall/roof with LED tube light fixtures driver,holders, connector etc, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA & IIIB, Zone 1 & 2, Tempclass T5 / T6, totally enclosed, dust and water proof with IP 65 protection and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS 16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. Make :- Shyam/Sudhir or equivalent.
S&F in replacement Switch Flame proof rotary type with termination box in LM6, 16 A, double pole with termination chamber 230V all as specified and directed by Engineer-in-Charge
S&F in replacement flame proof push button with indicator with termination box in LM6, with termination chamber 230V all as specified and directed by Engineer-in-Charge
Supply & Fix in replacement of ELCB/RCCB capacity 63 Amps 100mA three phase having charastics IEC 61008-1 Im-1000A, LNC-10000A 4 pole having single Knob for on off test switch, all as directed by Engineer-inCharge. Make - L&T model BGB 406310 / ABB/Havells
Supply and laying, testing and commissioning in replacement LT copper cable 1.1 KV Grade 2.5 Sqmm 3 core FRLSH steel wire armoured PVC insulated copper cable conforming to IS-7098 , CM/L 566489 laid in duct / tray / wall / ceiling with the help of steel clamps including cable glands with rubber cover etc complete all as specified & as directed.
Supply & fix in replacemet MCB SPN 230 V , 16 Amp 10 KA "C" curve rating confirms to IEC 60898-1 marked and connecting complete all as specified and directed by Engineer-in -Charge. Make :- L&T / ABB/Havells
Supply & fix in replacemet MCB SP 230V , 6 Amps 10 KA "C" curve rating confirms to IEC 60898-1 marked and connecting complete all as specified and directed by Engineer-in -Charge. Make :- L&T / ABB/Havells
Supply and fix in replacement flame proof switch Knob made of Ceramic / plastic to be fixed on Flame proof MCB DB box for operating the MCB ON/OFF all as directed by Engineer-in-Charge.
Material and labour for dismantling old earthing of any type. Supply, installation, testing of advanced maintenance free environment friendly CPRI approved earthing 10 feet long 17 mm dia earth electrode made high tensile low carbon steel circular rods, molecular bonded copper on outer surface (minimum copper bonded thickness 250 micron) with terminal to connect incoming copper strip 25 x 3 mm earthing strips with the equipment/machinery of desired length as per site requirement with 02 bags (25 Kg each) of environment friendly backfill compound with ROHS test certificate for each. The remaining space will be filled with soil and top of earth pit covered with high density polymer.Earth pit chamber cover of dimension (300 mm x 300 mm x 214 mm) with locking seal as to achieve the desired ohmic value complete all as specified and directed. Note :- (i) Payment will be released only after the resistance value achieved less than 1 ohm. If value of resistance found more than 1 ohm contractor will do the fresh earthing without any extra cost. (ii) Rate of Copper strip 25x3 mm from earthing terminal to equipment/machinery with suitable size nuts/bolts and washers is deemed to be included in rate quoted by tendrer.
BIDAWAT ENTERPRISES
KARNI ELECTRICAL CORRPORATION/ANKIT YADAV
BALAJI PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .