Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 CrAccepted-AOC 144 5B HARI NAGAR ASHRAM ASHRAM ROAD HARI NAGAR ASHRAM SOUTH DELHI DELHI 110014 UDYAM DL 09 0024874 | SOUTH EAST DELHI | DELHI | 110014 | ₹6.3 Cr | L1 | Accepted-AOC Lowest quoted rate |
| 2 | L2₹6.3 CrRejected-AOC BAIKUNTHAPUR HOUSE NO 77 PO LAIMEKURI PS JONAI DISTRICT DHEMAJI PIN 787060 | DHEMAJI | DHEMAJI | ASSAM | 787060 | ₹6.3 Cr | L2 | Rejected-AOC Second lowest rate |
| Sl No | Description | Qty | Unit | M/s Purbanchal Suppliers & Contractors L2 | Shree Ganesh Enterprises L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation for Structures
'Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.i) upto 3 m depth | 428.81 | Cum | 145.18 ₹62,254.49 | 145.18 ₹62,254.49 |
| 2.00 | Well Foundation Providing and constructing temporary Island 16 m diameter for construction of well foundation for 8 m dia well.complete as per clause 1203.2 of MORTH specifications. | 2 | Each | 8,22,808.84 ₹16.5 L | 8,22,808.84 ₹16.5 L |
| 3.00 | Providing and construction one span service road 10 m wide to reach island location to another pier location. | 52 | RM | 3,906.77 ₹2.0 L | 3,906.77 ₹2.0 L |
| 4.00 | Providing and laying of cutting edge of mild steel weighing 40 K.G. per meter for Well foundation complete as perv drawing and as per clause 1200 &1900 of MORTH specifications . | 2.89 | MT | 1,21,072.98 ₹3.5 L | 1,21,072.98 ₹3.5 L |
| 5.00 | Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications.
A. Well Curb I) RCC M - 20 grade Case - I : Using concrete mixer. | 110.66 | Cum | 9,603.3 ₹10.6 L | 9,603.3 ₹10.6 L |
| 6.00 | Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications.
B. Well steining III) RCC M- 20 grade Case I : Using concrete mixer. | 1,228.9 | Cum | 8,803.62 ₹1.1 Cr | 7,200 ₹88.5 L |
| 7.00 | Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications.
C. Bottom Plug Concrete to be placed using tremie pipe. II) PCC grade M-20 Case - I : Using concrete mixer. | 227.71 | Cum | 8,779.82 ₹20.0 L | 6,900 ₹15.7 L |
| 8.00 | Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications.
D. Intermediate plug II) PCC grade M - 25 Case - I : using concrete mixer. | 16.61 | Cum | 8,151.5 ₹1.4 L | 8,151.5 ₹1.4 L |
| 9.00 | Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications.
E. Top plug III) PCC grade M-25 Case - I : using concrete mixer. | 24.23 | Cum | 8,310.96 ₹2.0 L | 8,310.96 ₹2.0 L |
| 10.00 | Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications.
F. Well Cap I) RCC M - 20 grade Case - I : using concrete mixer. | 231.39 | Cum | 8,353.8 ₹19.3 L | 8,353.8 ₹19.3 L |
Tender Value
₹6.3 Cr
EMD Value
₹12.7 L
Closing Date
17 Jul 2025, 4:00 pmClosed
Executive Engineer, PWRD, DNTRD
O/o the Executive Engineer, PWRD, DNTRD
Construction of RCC Bridge in road from Bekulguri to Banjipathar under SDMF for the year 2023-24.
2025_PWD_45122_1
TB/268/DNTRD/2025-26/482/7
Open Tender
Civil Works - Bridges
360 days
Dhakuakhana
Please refer Tender documents.
3 documents required · 3 mandatory
₹12,700
₹12.7 L
Yes
O/o the Executive Engineer, PWRD, DNTRD
28 Jan 2026
27 Jun 2025
18 Jul 2025
27 Jun 2025
17 Jul 2025
27 Jun 2025
27 Jun 2025 - 3 Jul 2025
28 Jun 2025
Amount
Excavation for Structures 'Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.i) upto 3 m depth
Well Foundation Providing and constructing temporary Island 16 m diameter for construction of well foundation for 8 m dia well.complete as per clause 1203.2 of MORTH specifications.
Providing and construction one span service road 10 m wide to reach island location to another pier location.
Providing and laying of cutting edge of mild steel weighing 40 K.G. per meter for Well foundation complete as perv drawing and as per clause 1200 &1900 of MORTH specifications .
Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications. A. Well Curb I) RCC M - 20 grade Case - I : Using concrete mixer.
Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications. B. Well steining III) RCC M- 20 grade Case I : Using concrete mixer.
Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications. C. Bottom Plug Concrete to be placed using tremie pipe. II) PCC grade M-20 Case - I : Using concrete mixer.
Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications. D. Intermediate plug II) PCC grade M - 25 Case - I : using concrete mixer.
Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications. E. Top plug III) PCC grade M-25 Case - I : using concrete mixer.
Plain / Reinforced Cement concrete, in well foundationcomplete as perdrawing and as per clause 1200 , 1500 & 1700 of MORTH specifications. F. Well Cap I) RCC M - 20 grade Case - I : using concrete mixer.
Sinking of 7 m external diameter well ( other than pneumatic method sinking ) through all types of strata namely sandy soil, clayey soil anrock as shown against each case, complete as per drawing antechnical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil I) Depth below Bed level up to 3.0m
Sinking of 7 m external diameter well ( other than pneumatic method sinking ) through all types of strata namely sandy soil, clayey soil anrock as shown against each case, complete as per drawing antechnical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil II) Beyond 3.0 m upto 10.0 m
Sinking of 7 m external diameter well ( other than pneumatic method sinking ) through all types of strata namely sandy soil, clayey soil anrock as shown against each case, complete as per drawing antechnical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil III) Additional depth beyond 10 m up to 20 m
Sinking of 8 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil I) Depth below Bed level up to 3.0m
Sinking of 8 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil II) Beyond 3.0 m upto 10.0 m
Sinking of 8 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is rekonewed from bed level. A. Sandy soil III) Additional depth beyond 10 m up to 20 m
Sand fillingin wells complete as per drawing and technical specifications
Supplying, fitting and placing TMT IS 1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications as per MORTH clause 1600 TMT IS 1786 Fe500 D Primary producer (TATA/SAIL/ESSER STEEL /JINDAL STEEL/SHYAM STEEL or equivqlent
Plain / Reinforced Cement concrete in substructure complete as per drawing and Technical Specificationas clause 1500, 1700 & 2200. IV) RCC Grade M 25 i) Height upto 5.0m
Supplying, fitting and placing TMT IS 1786(Fe500) bar reinforcement in foundation complete as per drawing and technical specifications as per MORTH clause 1002,1005,1010,1202
Supplying, fitting and fixing in position true to line and level elastomer bearing conforming to IRC : (83 pt.l) section ix complete as per drawing and technical specifications clause 1207.1
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 i). Granular material
Providing and laying cement concrete in superstructure as per drawing and technical specifications clauses 800,1205.4 and 1205.5. F) With Crushed stones II) RCC M 35 1) Height iupto 5.0 m
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications
(High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and Technical Specifications
Providing and laying cement concrete wearing coat M 30 gradeincluding reinforcement complete as per drawing and technical specifications clauses 800,1206.3
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage Spouts complete as per approved drawing and technical specifications Clause 1209
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 From Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1 From .Private Land
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For Grading I Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.A.By Manual Means WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III
Providing and laying interlocking concrete block pavement with M40 grade of concrete blocks having thickness 80 mm as per technical specification clause1504 complete including carriage….. Including Edge block/ Edge restraintstion
Metal Beam Crash Barrier, Type- A: "W" Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2m center to center, 1.8 m high, 1.1m below ground/road level, all steel parts and fitments to be galvanized by hot dip process, all fitting to conform to IS:1367 and IS:1364, metal beam rail to be fixedon the vertical post with a spacer of channel section 150mm x 75mm x 5mm, 330mm long complete as per clause 810.)
Providing ‘Sparkle Solar Road Studs, manufactured by Tata B.P. Solar India Ltd. Of size (125mmx125mm), 90mm height (from bottom of shank to the top of stud) with detachable battery, m6LEDsthree on each side for Bi-directional studs/3 LEDs on one side for unidirectional studs, ultra bright LED in amber and red colour, weight per stud 700+25 gms, flash rate of 50-65 times per minute completely water resistant and weather proof with replacement warranty and free maintenance for one year from the date of installation of stud on road-(installation should be made using adhesives and procedures recommended by manufacturer under the supervision of their competent technician).
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes
Providing and erecting retro-relectorised cautinary, mandatory and informatory sign as per IRC-67 made of high intensity encapsulated lense type reflective sheeting vide clause No.801.3, fixed over aluminium sheeting, 2mm thick fixed on an angle iron post 25x25x4mm, supported on a mild steel angle iron post 75mmx75mmx6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45x45x60 cm, 60 cm below ground level as per approved drawing and sign.(All the steeel work must be Tata/SAIL or any other approved band). i) 60 cm equilateral triangle
Providing and erecting retro-relectorised cautinary, mandatory and informatory sign as per IRC-67 made of high intensity encapsulated lense type reflective sheeting vide clause No.801.3, fixed over aluminium sheeting, 2mm thick fixed on an angle iron post 25x25x4mm, supported on a mild steel angle iron post 75mmx75mmx6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45x45x60 cm, 60 cm below ground level as per approved drawing and sign.(All the steeel work must be Tata/SAIL or any other approved band). ii) 60 cm Circular
Providing and erecting retro-relectorised cautinary, mandatory and informatory sign as per IRC-67 made of high intensity encapsulated lense type reflective sheeting vide clause No.801.3, fixed over aluminium sheeting, 2mm thick fixed on an angle iron post 25x25x4mm, supported on a mild steel angle iron post 75mmx75mmx6mm firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45x45x60 cm, 60 cm below ground level as per approved drawing and sign.(All the steeel work must be Tata/SAIL or any other approved band). iv) Direction and Place Identification 80x60 cm Rectangular
'Direction and place identification sign upto 0.9sqm size board. Providing and erecting direction and place identification retro-Reflectrorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3 fixed over aluminium sheeting, 2mm thick with area not exceeding 0.9sqm fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand)
Providing and fixing of typical informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1 (From Analysis)
Providing and laying Pitching on slopes laid over prepared filter media for embankment protection complete as per drawing and Technical specifications
Providing and laying Filter material underneath pitching in slopes for embankment protection complete as per drawing and Technical specification
Boulder apron laid in (Providing and laying of boulder apron laid in made with in including 10% extra for laps and joints laid with stone boulders weighting not less than 40Kg each.)
Construction of embankment with materials obtained from borrowpits, with initial lead up to 3km, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 (including land compensation of earth) (b) 'From private land
By Mix in Place Method (GSB) (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density,complete as per cl. 401( with an initial lead of 5 Km.)( Including cost of testing of materials at site and laboratory as directed by the deptt.) (II) for grading- II Material Qty.:- 2X50 x 0.150 x 3 = 45.00 Cum
Construction of cold weather Bamboo bridge overall width of 3.70 m and clear roadway 3m with jungle wood post 20 cm to 25 cm dia 5nos. In each rows and rows being 2.1m apart except for the navigable span which should be 3m. Post to be driven at least 180 cm or more below ground level including providing 20 cm to 25 cm center to center and placed over 20 cm dia, jungle wood dham, 15 cm dia junglewood bracing collar fixed by bolts and nuts, straps etc. mature bholuka Bamboo cross groth all closely packed and tied 75 cm wide trackway made from 38 mm thick 1st class local plank fixed on 75 mm x 100 mm first class local wood battens 120 cm apart and 3 lines of jati bamboo horizantal railing fixed in bholuka bamboo post placed at 210 cm apart and white washed including all necessary nuts and bolts, coir ropes, struts, nails etc. complete with a layer of brush wood to exposed portion out-side trackway with earth topping complete as per direction of the department.
Geo technical Seismic Re qualification Study of Bakulguri to Banjipathar RCC Bridge
Community Engagement, Flood Awareness and Preparedness
Project Vetting Cost by IIT Guwahati
DPR Preparation Cost
M/s Purbanchal Suppliers & Contractors (BID ID -272206)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_71464.xls
BOQ • 0.32 MB
174230476.pdf
Tender Documents • 0.25 MB
174230478.html
Tender Documents • 0.05 MB
SBD_BRIDGE.pdf
Tender Documents • 4.51 MB
Download all tender documents and submit your bid