Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC 103 1ST FLOOR PAYAL RIDDHI CHS PLOT NO 51 SECTOR 27 KHARGHAR RAIGAD MAHARASHTRA 410210 | RAIGAD | MAHARASHTRA | 410210 | ₹41.5 L Quoted ₹42.2 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹45.4 L+₹3.2 L (7.51%)Rejected-Finance | ₹45.4 L+₹3.2 L (7.51%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹48.4 L+₹6.2 L (14.7%)Rejected-Finance 10 2 NARAYAN BAG INDORE M P | ₹48.4 L+₹6.2 L (14.7%) | L3 | Rejected-Finance Not being lowest |
| Sl No | Description | Qty | Unit | Vinayak Trading House L2 | S.S. Engineers L3 | Manu Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down of old unserviceable LT panel / building meter panel complete with all fittings and accessories of any capacity incl disconnecting all incoming and out going connections by removing cable glands, lugs, nut bolt and washers incl breaking of PCC for removing MS angle iron any size removing the loop of cables carefully complete incl removing single / three phase electric meter and depositing to MES (AGE E/M-II) all as specified and directed.
Note:
(1) Necessary shut down will be taken in writing before disconnecting all cables.
(2) M&L for Arrangement of Alternative / Bypass supply with all protective measures to the living accn shall deemed to be included in the quoted rates. | 21 | Each | 500 ₹10,500 Lowest | 500 ₹10,500 Lowest | 500 ₹10,500 Lowest |
| 2.00 | Supply, installation, commissioning and testing indoor type LT wall mounting Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four compartment for fixing of five Nos single phase meter and MCB and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip/wire busbar of suitable size to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incoming existing cable of any size complete all as directed. | 10 | Each Job | 77,000 ₹7,70,000 | 1,05,000 ₹10,50,000 | 55,000 ₹5,50,000 Lowest |
| 2.01INCOMMING:- (a) Copper strip busbar of size 25 x 5 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends = 04 Nos. (b) MCCB IP 44 and IP 66/67 protection Ics =100% lcu, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No. (c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos (d) Digital Ammeter (0- 500) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch and CTs – 01 Nos (e) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) | ||||||
| 2.02OUTGOING :- (a) MCB SPN 40 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed - 05 Nos (b) Fixing only serviceable existing electric meter- 05 Nos (obtained from taking down item ) | ||||||
| 3.00 | M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC FRLS concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed.
NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. | 200 | RM | 480 ₹96,000 | 440 ₹88,000 | 200 ₹40,000 Lowest |
| 4.00 | Description all as per ser item No. 3.00 here in above but with 2 runs of 10 sqmm main wire along with 01 runs of 6 sqmm earth wire. | 300 | RM | 620 ₹1,86,000 | 800 ₹2,40,000 | 300 ₹90,000 Lowest |
| 5.00 | Supplying, laying ,fixing, jointing and testing of LT under ground XLPE insulated, galvanized steel strip or wire armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 35 sqmm x 3.5 core IS 7098 marked with electric connection, lugs/in GI pipes incl connection to LT panels with gland all as specified and as directed.
Note: Excavation, earth work, sand cushioning, PCC cover and GI pipe shall be measured and paid separately. | 200 | RM | 400 ₹80,000 | 300 ₹60,000 Lowest | 330 ₹66,000 |
| 6.00 | M&L for cable jointing kit for LT XLPE cable 35 sqmm 3.5 core, heat shrinkable type complete all as specified and directed. | 4 | Each | 2,150 ₹8,600 | 800 ₹3,200 Lowest | 1,200 ₹4,800 |
| 7.00 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed. | 36 | Cum | 125 ₹4,500 | 120 ₹4,320 | 100 ₹3,600 Lowest |
| 8.00 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. | 17 | Cum | 35 ₹595 | 40 ₹680 | 30 ₹510 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
14 Jul 2026, 6:00 pmClosed
GE (AWC) Mhow
GE (AWC) Mhow
REPAIR/ REPLACEMENT AND MAINTENANCE OF BUILDING PANELS ALONGWITH ALLIED WORKS AND REPAIR/ REPLACEMENT AND MAINTENANCE OF STORAGE TYPE WATER HEATERS, CEILING FANS, WALL FANS, EXHAUST FANS AND ELECTRIC METERS UNDER GE (AWC) MHOW
2026_MES_771074_1
8949/AWC/MHOW/ OF 2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AWC) Mhow
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AWC) Mhow
₹90,000
5 Sept 2026
10 Jun 2026
16 Jul 2026
10 Jun 2026
14 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down of old unserviceable LT panel / building meter panel complete with all fittings and accessories of any capacity incl disconnecting all incoming and out going connections by removing cable glands, lugs, nut bolt and washers incl breaking of PCC for removing MS angle iron any size removing the loop of cables carefully complete incl removing single / three phase electric meter and depositing to MES (AGE E/M-II) all as specified and directed.
Note:
(1) Necessary shut down will be taken in writing before disconnecting all cables.
(2) M&L for Arrangement of Alternative / Bypass supply with all protective measures to the living accn shall deemed to be included in the quoted rates. | 21 | Each | - | - |
| 2 | Supply, installation, commissioning and testing indoor type LT wall mounting Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four compartment for fixing of five Nos single phase meter and MCB and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip/wire busbar of suitable size to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incoming existing cable of any size complete all as directed. | 10 | Each Job | - | - |
| 2.01 | INCOMMING:-
(a) Copper strip busbar of size 25 x 5 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrographic insulators with nuts & bolts at both ends = 04 Nos.
(b) MCCB IP 44 and IP 66/67 protection Ics =100% lcu, 4 pole, 415 volts, Lcu=25 KA breaking capacity, rating 100 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.
(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 Nos
(d) Digital Ammeter (0- 500) Amps, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch and CTs – 01 Nos
(e) LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) | - | - | - | - |
| 2.02 | OUTGOING :-
(a) MCB SPN 40 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed - 05 Nos
(b) Fixing only serviceable existing electric meter- 05 Nos (obtained from taking down item ) | - | - | - | - |
| 3 | M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC FRLS concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed.
NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. | 200 | RM | - | - |
| 4 | Description all as per ser item No. 3.00 here in above but with 2 runs of 10 sqmm main wire along with 01 runs of 6 sqmm earth wire. | 300 | RM | - | - |
| 5 | Supplying, laying ,fixing, jointing and testing of LT under ground XLPE insulated, galvanized steel strip or wire armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 35 sqmm x 3.5 core IS 7098 marked with electric connection, lugs/in GI pipes incl connection to LT panels with gland all as specified and as directed.
Note: Excavation, earth work, sand cushioning, PCC cover and GI pipe shall be measured and paid separately. | 200 | RM | - | - |
| 6 | M&L for cable jointing kit for LT XLPE cable 35 sqmm 3.5 core, heat shrinkable type complete all as specified and directed. | 4 | Each | - | - |
| 7 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed. | 36 | Cum | - | - |
| 8 | Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. | 17 | Cum | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tdocus.pdf
Tender Documents • 1.35 MB
BOQ_863479.xls
BOQ • 3.13 MB
Makelist.pdf
Tender Documents • 0.77 MB
Corg1.pdf
PDF • 0.83 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .