GE (AWC) Mhow
GE (AWC) Mhow
REPAIR/ REPLACEMENT AND MAINTENANCE OF BUILDING PANELS ALONGWITH ALLIED WORKS AND REPAIR/ REPLACEMENT AND MAINTENANCE OF STORAGE TYPE WATER HEATERS, CEILING FANS, WALL FANS, EXHAUST FANS AND ELECTRIC METERS UNDER GE (AWC) MHOW
2026_MES_771074_1
8949/AWC/MHOW/ OF 2026-27
Open Tender
Electrical and Maintenance Works
180 days
GE (AWC) Mhow
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AWC) Mhow
₹90,000
10 Jun 2026
10 Jun 2026
4 Jul 2026
10 Jun 2026
2 Jul 2026
25 Jun 2026
Supply, installation, commissioning and testing indoor type LT wall mounting Panel Board of minimum size 1.00 m (height) x 1.00 m (breath) x 0.30m (depth) factory made CPRI approved panel, weather, dust & vermin proof indoor, double door, front openable, including four compartment for fixing of five Nos single phase meter and MCB and providing glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/sleeves with maintained the colour code and copper strip/wire busbar of suitable size to MCCB input and MCCB/MCB output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel CRCA sheet with suitable size angle iron supporting frame including applying two coats of Powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incoming existing cable of any size complete all as directed.
OUTGOING :- (a) MCB SPN 40 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed - 05 Nos (b) Fixing only serviceable existing electric meter- 05 Nos (obtained from taking down item )
M & L sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC FRLS concealed / surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same & taking down complete all as specified and directed. NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length.
Description all as per ser item No. 3.00 here in above but with 2 runs of 10 sqmm main wire along with 01 runs of 6 sqmm earth wire.
Supplying, laying ,fixing, jointing and testing of LT under ground XLPE insulated, galvanized steel strip or wire armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 35 sqmm x 3.5 core IS 7098 marked with electric connection, lugs/in GI pipes incl connection to LT panels with gland all as specified and as directed. Note: Excavation, earth work, sand cushioning, PCC cover and GI pipe shall be measured and paid separately.
M&L for cable jointing kit for LT XLPE cable 35 sqmm 3.5 core, heat shrinkable type complete all as specified and directed.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L of locally available river sand in trenches below and above / around UG cable for cable protection, in duct under & above the cables including punning around cable complete all as specified and directed. Note - Punned thickness shall only be measured and paid.
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
Supply and laying GI pipe light grade 50 mm in trenches, under floors,roads,along poles for protection of cable with all necessary fittings and sealing ends complete all as specified and as directed.
M&L for breaking PCC carefully and by manually incl taking out loop of XLPE cable and GI protection pipes all as specified and directed
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete incl necessary form work all as specified and directed .
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete incl necessary form work all as specified and directed. Note for item No 14 and 15 : The rate includes M&L for necessary form work .
M&L for brick work sub class B modular brick straight or curved on plan exc 06 m mean radius built in cement mortar 1.6 complete all as specified and directed.
M&L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1.4 surface finished even and smooth complete all as specified and directed.
Supply, installation, commissioning and testing of factory made Meter panel of size 680mmx 1100mmx 247mm suitable to accommodate 04 nos single phase electric meter ,IP 65 made of high quality poly carbonate PC-GFS (shock proof, rust free, corrossion free, acid and chemical resistyant , fire retardent, self-extinguishing, having high impact against mechanical load made of halogen and silicon free recyclable material confirm to IEC 61439-1, having high grade internally embeded gasket made of polyurethane(PUR) having CPRI approved indoor type should with stand glow wire test at 960 degree cent in accordance with IEC 60 695-2-11, with pad locking arrangement , also suitable to resist condensation inside suitable for 3 phase 4 wire system 415/440 volts grade including complete internal wiring with 2.5 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as directed by Engineer-in-Charge. Make : Hansel cat No. HEN MI MP-2110-2023-1 or equivalent make in L & T /Havells/ABB/ C & S
INCOMMING (a) MCCB 4 pole 25 KA , 100 A rating Ics=100% Icu - 01 Nos
OUTGOING (a) Fixing only Single phase energy meter (10-60A) -04 Nos (b) S&F 40 Amps DP MCB, C series , 10 KA - 04 Nos (c) S&F 10 Amps DP MCB, C series , 10 KA - 01 Nos (d) 10 sqmm terminal block - 10 Nos (e) 06 sqmm terminal block - 02 Nos (f) 06 sqmm terminal block - 02 Nos (g) 10 sqmm earth terminal block - 05 Nos (h) 06 sqmm earth terminal block - 01 Nos
Replacement of Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanized earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc. complete all as shown in electrical plate No 5, connected to earthing test point complete including testing on completion all as specified.
Dismantling and opening of ceiling fan for overhauling any make, greasing and oiling of ball bearing and bushes respectively & reassembling the fan after servicing, greasing etc complete including replacement of unserviceable fan capacitor 2.5/3.15 MFD, copper flexible twin core PVC sheathed and overall insulated cable of size 23/.0076, capacitor holding clamps, canopy, locking screw, split pin, rubber reel, nut bolts with washers PVC connection 2 way and blade screws complete all as specified and directed for ceiling fan of 1200 mm sweep Note : All new spare parts shall be measured and paid separately.
Dismantling and opening of ceiling fan for overhauling any make, greasing and oiling of ball bearing and bushes respectively & reassembling the fan after servicing, greasing etc complete including replacement of unserviceable fan capacitor 2.5/3.15 MFD, copper flexible twin core PVC sheathed and overall insulated cable of size 23/.0076, capacitor holding clamps, canopy, locking screw, split pin, rubber reel, nut bolts with washers PVC connection 2 way and blade screws complete all as specified and directed for ceiling fan of 1400 mm sweep Note : All new spare parts shall be measured and paid separately.
M & L Painting of fans and blades any make and sizes with two coats of broken white enameled paint with spray gun of approved quality after removing all dust/grease and scrapping up old painted surface including preparation, filling of cavaties with metal putty, complete including writing MES No in 2mm width letter on fan body with black enameled paint and two circular golden circles of 2mm thickness on outer edge of bottom side complete all as specified and directed.
Dismantling of complete exhaust fan 300 mm sweep unscrewing the body parts of the exhaust fan taking out ball bearing, gun metal bush etc. Incl removing the fan from its original position ,overhauling and varnishing heating as per manufactures design and directed. Re-assembling complete exhaust fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, incl refixing the same in its original position complete all as specified and design to give designed air delivery including greasing, oiling etc complete all as specified and directed.
Description all as per ser item No. 23.00 above but exhaust fan of size 450 mm sweep.
Taking down and dismantling of complete pedestrial fan / cabin fan 400 mm sweep unscrewing the body parts of the fan taking out ball bearing gun metal bush etc. Removing of unserviceable ball bearing, gun metal bush, overhauling and varnishing heating as per manufactures design and directed. Re-assembling complete fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.
Taking down and dismantling of complete PVC exhaust fan 200/250/300 mm sweep by unscrewing the body parts of the fan taking out ball bearing , gun metal bush etc. Removing of unserviceable ball bearing, gun metal bush, overhauling and varnishing heating as per manufactures design and directed. Re-assembling complete fan by fixing only serviceable of old/new spare parts (i.e.) condenser, gun metal bushes, ball bearing, twin twisted copper cable, complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed.
Notes for Sl item no. 20 to 26 :- (a) Spare parts found unserviceable / defective will be measured and paid separately under relevant item as supply only. (b) The element for fixing of new spare parts are deemed to be included in quoted unit rate of above items.
Supply only condenser of capacity 2.5 to 3.15 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete all as specified and directed .
Supply only condenser of capacity 4 MFD, 230 volts, 50 Hz AC confirming to IS 1709 complete all as specified and directed .
Supply only Rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200 mm / 1400 mm sweep complete all as specified and directed ..
Supply only Gun metal bush 15 mm size as per sample complete all as specified and directed ..
Supply only Split Pin of size 25 mm long complete all as specified and directed .
Supply only Ball bearing of size 6201 / 6202 / 6203 as per sample complete all as specified and directed .
Supply only in repair MS down rod 'medium grade' 15mm dia of length 0.75 mtr complete with making split holes, cut or threads at both end of pipe as required for hanging of ceiling fan incl. painting of rod with two coats of synthetic enamel white paint over one coat of primer all as directed.
Description all as per ser item No. 33.00 above but of length 1.0 mtr to 1.20 mtr as per requirement at site
Supply only 'U' shape shackle clamp assembly incl checknut, bolts, screws, washer, lock nut, rubber reel etc. and connecting complete all as directed.
Supply only fan hook made out of steel bar as per sample
Supply only PVC insulated flexible wire twin core twisted copper conductor of size 0.75 Sqmm (24 / 0.20) complete.
Repair / maintenance and servicing of non functioining geysers of 25 ltrs capacity due to any defect like air lock, water leakage in pipe line joints,non functioning of any parts, checking electric connections and making good the loose electric connection and pipe line leakage etc.and making the geysers functional complete
Taking down carefully storage type water heater (geysers) of 25 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing / cutting of holding bolts / nuts from walls and opening the tank for repair including taking out inner assembly and scraping scale deposite on the surfcae of assembly, cleaning and washing and re-assembling after repairs and fixing the same in its original position and making necessary water supply and electric connection and testing complete all as specified and directed. Note:- The quoted unit rate is deemed to be included taking down of geyser from original position and refixing after repair incl the cost of nut and bolt if any required at site incl necessary cost of rubber gasket in any size complete all as specified and as directed.
Taking down carefully storage type water heater (geysers) of 50 litres capacity for servicing after disconnecting existing water supply and electric connection by unscrewing / cutting of holding bolts / nuts from walls and opening the tank for repair including taking out inner assembly and scraping scale deposite on the surfcae of assembly, cleaning and washing and re-assembling after repairs and fixing the same in its original position and making necessary water supply and electric connection and testing complete all as specified and directed. Note:- The quoted unit rate is deemed to be included taking down of geyser from original position and refixing after repair incl the cost of nut and bolt if any required at site incl necessary cost of rubber gasket in any size complete all as specified and as directed.
Notes for Sl item no.38 to 40 :- (a) Spare parts found unserviceable / defective will be measured and paid separately under relevant item as supply only. (b) The rate for fixing of new spare parts are deemed to be included in quoted unit rate of above items.
Supply only copper sheathed and nickel plated heating element 1.5 kW with gasket (ISI marked) push/ threaded type suitable for horizontal or vertical type water storage type water heater (Geysers) all as specified and directed.
Description all as per ser item No. 41.00 above but heating element 2 kW complete all as specifed and directed .
Supply only copper sheathed and nickel plated heating element 1.5 kW with gasket (ISI marked) round / cup type suitable for horizontal or vertical type water storage type water heater (Geysers) all as specified and directed.
Supply only thermostat, suitable for any make & type of geyser 50/ 25 litres capacity horizontal or vertical type complete all as specified and directed.
Note for Item No 41 to 44 : Model Nos of each item shall be vary as per site requirement and shall be be procured accordingly.
Supply only indicating lamp for geysers of any type make & capacity all as specified and directed.
Supply only 15 mm size CP Brass inlet and outlet assembly complete with rubber gasket, nuts, bolts and washers suitable for housing heating elements, thermostat etc. for 25 litre capacity storage type water heater complete all as specified and directed.
S&F fill glass wool for geysers including taking down old glass wool complete all as specified & directed.
Supply only rubber gasket round / flat suitable for inlet and outlet assembly of any capacity geyser as per sample.
Supply only mild steel expansion fastners 10 mm dia and 100 mm long to walls by drilling complete with washers etc. and making good disturbed surfaces to match with the existing all as specified and directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts, of length 450 mm complete all as specified and directed.
M&L for spray painting to existing Geysers of any capacity 25 Ltrs with supper enameld heat resistant paint of approved colour complete with scrapping old surfaces, filling cavities and writting MES no. complete all as specified and directed.
S&F fan blde 1200mm sweep complete all as specified and directed.
S&F Metal clad plug and socket 20 Amps, 230 V, 50 Hz all as specified and directed.
Taking down / dismantling and removing inner stainless steel/ copper tank of geyser (any make), 25 litres capacity and rectification of leakage by welding/ brazing with suitable metal including all necessary denting etc and re-assembling the same including making connections complete all as specified and directed.
S&F metal plug and socket DB, two pin and earth plug, 240 volts and including one 20 Amp MCB SP, C-Curve & including taking down of old/unsv concealed metal box replacing with new, making good cement work and paint complete all as specified and directed.
S&F in repairs PVC insulated and PVC sheathed 3 core copper conductor flexible round cable size 2.5 sqmm complete all as specified and directed.
S&F in repairs Chromium plated, Concealed stop cock short body, cast copper alloy, screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle, screwed externally both ends for unions etc.
S&F in repairs Chromium plated fancy long body Bib taps, cast copper alloy, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified.
S&F in repairs prepainted inspection plate rounded in two pieces made out of 22 gauge MS sheet suitable for 25 Litres and with fixing space for indicating lamp of any type geyser and any make and capacity including fixing screws complete all as specified and directed.
S&F screwed type Bronze vertical check valve 15 mm bore by cutting and threading of GI pipe including necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.
S&F screwed type Bronze air release valve 15 mm bore by cutting and threading of GI pipeincluding necessary fittings like sockets, unions, elbow, nipples etc. complete all as specified and directed.
Supply & fix new air release valve 15 mm bore for geyser as per existing type including taking down old unserviceable air release valve’s complete all as specified and directed.
S&F wall mounted fan 400 mm sweep, single phase 230 volts including flexible copper cable for electric connections complete all as specified and as directed.
S&F air freshner fan 200 mm sweep, 900 RPM, PVC body AC single phase 230 volt, with inbuilt louver complete all as specified and directed.
S&F air freshner fan 250 mm sweep, 900 RPM, PVC body AC single phase 230 volt, with inbuilt louver complete all as specified and directed.
S&F air freshner fan 300 mm sweep, 900 RPM, PVC body AC single phase 230 volt, with inbuilt louver complete all as specified and directed.
S&F in repairs modular surface mounted plastic boxes 06 module for fixing of switch socket combination 6 Amps (02 Nos) ISI marked complete all as specified and as directed.
S&F in repairs plug top 15 Amps complete all as specified and as directed.
Description all as per ser item No. 68 above in above but of 5 Amps.
S&F in replacement of PVC casing n caping where ever necessary of size 20 mm size incl screws, wooden/plastic packing complete all as specified and as directed.
Taking down old bottom plate of geysers 25 liters capacity & supply & fix new bottom plates of same sizes and shape complete all as specified & directed.
Description all as per item No. 71.00 above but of capacity 50 Ltrs complete all as specified and directed
Supply and install PVC Geyser water heater outer cover ( Geyser body ) suitable for 25 ltr including top and bottom cover plate comple with all nuts , bolts, washer,glasswool for insulation complete all as specified and directed.
Supply and install PVC Geyser water heater outer cover ( Geyser body ) suitable for 50 ltr including top and bottom cover plate comple with all nuts , bolts, washer,glasswool for insulation complete all as specified and directed.
Supply in replacement for exhaust fan Louver of size 300mm, complete all as specified and directed
Supply in replacement for exhaust fan Louver of size 380mm, complete all as specified and directed
S&F in replacement of inner water storage copper tank of suitable for 25 ltrs capacity complete all as specified and directed
S&F in replacement of inner water storage stainless steel tank of suitable for 25 ltrs capacity complete all as specified and directed
S&F in replacement of inner water storage copper tank of suitable for 50 ltrs capacity complete all as specified and directed
S&F in replacement of inner water storage stainless steel tank of suitable for 50 ltrs capacity complete all as specified and directed
S&F in replacement of geyser ' U' assembly for 25/ 50 ltrs capacity water heaterincluding as per existing make replacement of rubber seal and nuts and bolts completeall as specified and directed.
S&F in replacement sheet metal enclosures DB Double door type 8 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified and directed
S&F in replacement sheet metal enclosures DB Double door type 4 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified and directed
S&F sheet metal enclosures DB Double door distribution type, 04 way, TPN DB , IP43, 415V & suitable for MCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer, complete all as specified and directed
S & F for ceiling fan, 230 Volts, 50Hz, 1200 mm sweep with down road, canopy, blades, BLDC motor etc and service value of the fan shall be greater than 6.1 as per BIS with necessary accessories and electrical connections from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and as directed.
Supply and fixing storage type water heater complete 25 ltrs capacity stainless steel tank 230 volt, 50HZ all as specified and directed.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
Tdocus.pdf
Tender Documents • 1.35 MB
BOQ_863479.xls
BOQ • 3.13 MB
Makelist.pdf
Tender Documents • 0.77 MB
Download all tender documents and submit your bid