| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹25.2 L+₹84,288 (3.46%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Jan 2023, 6:00 pmClosed
CWE PUNE
HEADQUARTERS COMMANDER WORKS ENGINEERS GEN CARIAPPA MARG, PUNE-411 001
85851REPLACEMENT/ REPAIR / MAINTENANCE OF PACKAGE , SYSTEM / CENTRAL AIR CONDITIONER, COOLING TOWERS, COLD STORAGE PLANTS AND REPAIR TO ELECTRIC CONTROL PANELS AT AICTS / MITS AND D / CH COMPLETE OTHER CONNECTED AREA UNDER AGE E/M (SOUTH) PUNE.
2022_MES_560793_2
85851REPTOPACKAGEACATGESPUNE
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE South Pune
As per Tender
9 documents required · 9 mandatory
₹500
GE South Pune
₹70,000
Yes
13 Mar 2023
5 Jan 2023
26 Jan 2023
5 Jan 2023
24 Jan 2023
12 Jan 2023
Amount
M&L for replacement for Domnic hunder filter from the assembly of air pressure line of the air compressor unit of existing size and same capcity including accessaries complete all as specified and as directed.
M&L for replacement for air pressure cut out of the air compressor unit of existing size and same capcity including accessaries complete all as specified and as directed.
M&L for replacement for automatic water switch with satrainer air compressor unit of existing size and same capcity including accessaries complete all as specified and as directed.
M&L for replacement for Vaccum pressure cut out unit of existing size and same capcity including accessaries complete all as specified and as directed.
M&L for replacement for fully automatic star delta starter MN45-FASD same capcity including accessaries complete all as specified and as directed.
M&L for replacement for Single phase preventor same capcity including accessaries complete all as specified and as directed.
M&L for replacement for automatic pressure release switch with strainer of existing size and same capacity including accessaries complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr in deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level including connecting GI earth wire 4 mm dia by GI nut, bolt, washers all as shown in electrical plate No. 3 of SSR Part I of 2009 including funnel, PCC chamber, chamber cover, charcoal salt etc complete including excavation and earth work in any strata, test point and testing on completion including filling up the earth pit with black cotton soil for best result and removal of excavated material from site all as specified and directed by Engineer-in-charge.
M&L for complete cleaning of ducts by using HEPA filtered vaccum unit to create negative pressure in the duct system, by placing the same outside the occupied space by using variety of tools to agitate and loosen the dust, which shall be then drawn into the vaccum unit and contained therein. the cleaning should be done by using robotic tool ,monitored & operated remotely video camera for cleaning the hard to reach areas, which are out of reach for most duct cleaning equipments. Access cutting can be made, if required and shall later be refitted with screw and sealant. All floors and furnishing where the work will be carried on shall be covered and complete care shall be taken to avoid minimum amount of cross- contamination. upon completition of work the system shall be sanitized by fogging the ducts to ensure all mold and bacteria spores and foul smell is eradicated the entire process shall be caried out with Air compressor with bib, pneumatic air whips and power jobs, Rotary brush Drum vaccum wit pipe. Negative machine HEPA and 10" hose pipe and Robo camera with control unit. All clening agents/chemicals used shall be inaccordance with the regulation and shall be certified for use in the respective system for CHSC ICU palnt (54TR running) .During the inspection process collect particulate samples from the duct interior to provide with a complete laboratory analysis of the particulate content to identify hazards such as asbestos. Microbial samples are also taken to evaluate the duct surface for bacteria and mould growth as directed and specified by Engr-in Charge. Note For item 9 to 16 : PVC sheets reqd for ingress Protection of medical equipments will be arranged by the contractor and its cost is included in unit rate
All as per item No. 09 here- in- above but for CHSC New OT plant (35TR running).
All as per Item No. 09 here-in-above but for CHSC Lower OT plant (34TR running).
All as per Item No. 09 here-in-above but for CHSC Burn centre plant (20TR running).
All as per Item No. 09 here-in-above but for CTC ICU plant (66TR running).
All as per Item No. 09 here-in-above but for CTC OT 1&2 plant and MITS & D (80TR and 40TR running).
All as per Item No. 09 here-in-above but for plant ALC (50TR running).
All as per Item No. 09 here-in-above but for plant Negative pressure room at AICTS (4TR running).
M&L for replacement for brass ball valve from liquid lie of size 1 -1/8 " from the liquid line in a suitable way including necessery jointing and joining material complete all as specified and as directed.
M&L in replacement for brass ball valve from liquid lie of size 7/8" " from the liquid line in a suitable way including necessery jointing and joining material complete all as specified and as directed.
Taking down and M&L for dry in repairs frame valve of air dryer of existing size and same capacity including accessaries complete all as specified and as directed.
M&L for replacement for inlet filter element of air dryer of existing size and same capacity including accessaries complete all as specified and as directed.
M&L for replacement for drain filter element of air dryer of existing size and same capacity including accessaries complete all as specified and as directed.
M&L for replacement for oulet filter element of air dryer of existing size and same capacity including accessaries complete all as specified and as directed.
M&L for replacement for aluminia silicagel of air dryer of existing size and same capacity including accessaries complete all as specified and as directed.
M&L for replacement for auto switch of air dryer of existing size and same capacity including accessaries complete all as specified and as directed.
Taking out old unserviceable compressor oil, supply and charge by topping up compressor oil N-68, Make :- Sheetal / Servo or equivalent
S&F following spare part of Compressor model AC 470, Make: Kirloskar or equivalent
Piston Ring.
Strainer suction assembly.
Oil Pump Assembly.
Oil filter.
O' Ring set.
Gasket set.
Suction & Discharge valve reeds.
Magnetic Strainer.
S&F following spare part of Compressor model No. SMC-465 Make : Accel
Piston Ring.
Strainer suction assembly.
Oil Pump Assembly.
Oil filter.
O' Ring set.
Gasket set.
Suction & Discharge valve reeds.
S&F spare part of Compressor. model No. FK - 450 & 500 Make : Frizking
Piston Ring.
Strainer suction assembly.
Oil Pump Assembly.
Oil filter.
O' Ring set.
Gasket set.
Suction & Discharge valve reeds.
S&F spare part of Compressor. model No. 05040S Make : Voltas
Strainer suction assembly.
Oil Pump Assembly.
Oil filter.
O' Ring set.
Gasket set.
Suction & Discharge valve reeds.
Cap Control valve without bellow.
S&F following spare part of Compressor. model SMC - 8- 65, Make: Accel
Piston Ring.
Strainer suction assembly.
Oil Pump Assembly.
Bearing bush.
Oil filter.
O' Ring set.
Gasket set.
Suction & Discharge valve reeds.
Gudgen pin.
Magnetic Strainer.
Supply only Refrigerant gas R-22, Make : Mafron
Supply only Refrigerant gas R-134a, Make : Mafron
Taking down carefully defective /unserviceable Shaft seal assembly complete from existing compressor installed at site and supply and fix new shaft seal assembly for Compressor model AC-470, Make : Kirloskar
All as per item No 33 here- in- above but for Compressor model No SMC-4-65, Make: Accel
All as per item No 33 here- in- above but for Compressor model No. FK-450, & 500 Make : Frizking
All as per item No 33 here- in- above but for Compressor model No. 05040S, Make : Voltas
All as per item No 33 here- in- above but for Compressor model No. 865, Make : Accel
Supply and fix in repairs to suction and discharge valve of following models of compressor by means of replacing the teflon washer sheet, suction and discharge valve ring, spring, 'O' Rings, gasket complete and testing for proper holding of Compressor model AC-470, Make :- Kirloskar
All as per item no 38 here- in- above but for Compressor model No SMC-465, Make: Accel
All as per item no 38 here- in- above but for Compressor model FK - 450 & 500 Make:Kirloskar
All as per item no 38 here- in- above but for Compressor model 05040S, Make:Voltas
All as per item no 38 here- in- above but for Compressor model 865, Make : Accel
S&F in replacement of Oil pressure cut Off switch. Make: Indfoss / Danfoss
S&F in replacement of compound gauge for low pressure 32 to 250 Kg/cm2 working on F-12 and F-22 gas Make : FIEBIG
S&F in replacement of HP/LP cut off switch, Make - Indfoss/Danfoss
S&F in replacement pressure gauge suitable for working on F-22 & F-12 gas of ranges 0-300 Kg/Cm2as per site requirement Make : Fibics
S&F in replacement of thermostatic expansion valve of suitable flare size including Brazing, Welding work etc. for the following type/model working on F -12,F-22 & 134a gas complete.
Thermostatic expansion valve model HVE-16, CP-100 Make : Sporlon or Equivalent
Thermostatic expansion valve model SVE-8, VCP-100 Make : Sporlon or Equivalent
Supply, Install, test and commissioning compressor of following capacity make Kirloskar copeland or equivalent for Package type AC
Compressor 5 to 12 TR model DPA-1202 Make - BlueStar
S&F in replacement of thermostatic expansion valve of suitable Flaire size including brazing/ welding works etc for the following Make : Danfoss or equivalent
Package type AC 5 TR to 12 TR.
S&F in replacement of Solenoid valve for package AC 5 to 12 TR.
S&F in replacement of Solenoid coil of suitable size Make sporlon or equivalent
S&F in replacement of strainer for 5 to 12 TR Package type ACs
S&F in replacement of unserviceable / leakage Service Valve suitable for 5 to 12 TR capacity Package AC Plant.
M&L for repairs to cooling Coil of above 75 TR capacity by means of opening the cooling coil, with pressure air and water, charge the Nitrogen gas for pressure leak test complete and repairing the same by means of soldering / brazing, repairs to drain water bottom portion by means of replacement of old rusty GI Sheets with 22 gauge of new GI sheet complete with fabrication work etc of size 2400x1800 MM and making good thermal insulation with glass wool, wire mesh plaster for blower portion.
M&L for repairs to cooling Coil 50 to 60 TR capacity by means of opening the cooling coil, with pressure air and water, charge the Nitrogen gas for pressure leak test complete and repairing the same by means of soldering / brazing, repairs to drain water bottom portion by means of replacement of old rusty GI Sheets with 22 gauge of new GI sheet complete with fabrication work etc of size 2400x1800 MM and making good thermal insulation with glass wool, wire mesh plaster for blower portion.
M&L for repairs to cooling Coil 30 to 35 TR capacity by means of opening the cooling coil, with pressure air and water, charge the Nitrogen gas for pressure leak test complete and repairing the same by means of soldering / brazing, repairs to drain water bottom portion by means of replacement of old rusty GI Sheets with 22 gauge of new GI sheet complete with fabrication work etc of size 2400x1800 MM and making good thermal insulation with glass wool, wire mesh plaster for blower portion.
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timers from the existing pannel board of 50 to 80 TR capacity AC plant replacing the power cables and circuit wiring with 16 sq mm and 2.5 Sq mm stranded copper cables including repairs/ replacing Contactors, timers and Relays. (Note:- Contactor ML1.5, ML 2, ML 3, Timers and relays will measure and paid separately under respective items of schedule.)
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timers from the existing pannel board of 20TR capacity AC plant replacing the power cables and circuit wiring with 10 sq mm and 4 Sq mm stranded copper cables including repairs/ replacing Contactors, timers and Relays. (Note:- Contactor ML1.5, ML 2, ML 3, Timers and relays will measure and paid separately under respective items of schedule.)
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timer from the existing pannel board of 30 to 35 TR capacity AC plant, Replacing the new Copper multi strand Power cables 10 Sq mm, Circuit wiring with Copper multi strand Power cables 4 Sq mm including controlling accessories like MCCBs, Contactors , relays and timer etc. (Note :- Controlling accessories like MCCBs, Contactors , relays and timer will be measure and paid separately under respective items of schedule.)
Disconnecting & Dismantling the old Power cables, Circuit wiring and controlling accessories like MCCBs, Contactors , relays and timer from the existing pannel board of Cold storage AC plant upto 10 TR capacity and replacing the new Copper multi strand Power cables 6 Sq mm, Circuit wiring with Copper multi strand Power cables 2.5 Sq mm including controlling accessories like MCCBs, Contactors , relays and timer etc .(Note :- Controlling accessories like MCCBs, Contactors , relays and timer will be measure and paid separately under respective items of schedule.)
Supply and fix in replacement Ammeter as per sample of following ratings:-
S&F contactor ML-1.5 with coil voltage 230 volt AC Make : L&T/C&S/Indoasian/Havells.
S&F contactor ML-2 with coil voltage 230 volt AC MMake : L&T/C&S/Indoasian/Havells
S&F contactor ML-3 with coil voltage 230 volt AC Make : L&T / C&S / Indoasian / Havells.
S&F contactor MNX 25 ,3 pole with coil voltage 230 volt AC Make : L&T/C&S/Indoasian/Havells
S&F contactor MNX 32 ,3 pole with coil voltage 230 volt AC Make : L&T/C&S/Indoasian/Havells
S&F ADD ON Block 2NO+2NC for MNX contactor .Make : L&T/C&S/Indoasian/Havells
Supply and fix in replacement CT's 100/5,5 VA as per sample
S&F electronic timers, Model GT-200 240 volts AC Make : L&T/C&S/Indoasian/Havells
S&F electronic star delta timers / Timer ET, 240 volts AC Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 1.5 to 2.5 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 2.5 to 4.1 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 4 to 6.5 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 6 to 10 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 9 to 14 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 13 to 21 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 24 to 32 Amps, Make : L&T/C&S/Indoasian/Havells
S&F bimetal overload relay, direct mounting type suitable for ML series of range 28 to 42 Amps, Make : L&T/C&S/Indoasian/Havells
S&F MCCB 200 Amp, 3 pole 25 KA breaking capacity, 440V, AC.
S&F MCCB 250 Amp, 3 pole 25 KA breaking capacity, 440V, AC.
S&F MCCB 100/125 Amp, 3 pole 25 KA breaking capacity, 440V, AC
S&F MCCB 63 Amp, 3 pole 16 KA breaking capacity, 440V, AC
S&F in replacement of MCB TPN 63 Amp, 3 pole 10 KA breaking capacity 440V, AC
S&F in replacement of MCB TPN 40 Amp, 3 pole 10 KA breaking capacity 440V, AC
S&F in replacement of MCB TPN 32 Amp, 3 pole 10 KA breaking capacity 440V, AC
S&F in replacement of unserviceable Solid state indicating lamps 230 Volt AC with RYB and green indication (LED type ) including adopter ring / washer and cable connection complete. Make: Altos
S&F in replacement of digital type temperature indicator including sensor and multicore copper cable ( Length of cable as per requirement )
Taking out burnt/unserviceable fan/blower motor of Package type AC and S&F new fan/blower motor double shaft single/double speed, single phase, 230 VAC complete suitable fixing arrangement for existing phase (as per sample) of following capacity Make : AUE/ Flugmaster/Pophler
Suitable for upto 5 to 12 TR capacity Package AC
Supplying & laying in replacement insulating mat of size 2000 x 1000 x 12 mm thick with ISI mark of LT side
S&F in replacement of HP/LP cut off switch, MP-15 Make : Danfoss/Indofoss
S&F in replacement single phase preventer of model VSP D-1A/SP-3, Make : Minilec
S&F in replacement Contactor 3T II, Make : Siemens
Repairs to cooling tower by means of replacement of unserviceable filters, cleaning the filters and replacing the Gun metal / Nylon Nozzles etc (Note :- Gun metal/Nylon Nozzles shall be measured and paid separately under respective items of sch.)
S&F Nylon Nozzles as per sample
Taking down motor 40HP from foundation by disconnecting electrically and mechanically, transporting to workshop for rewinding with ISI marked copper winding wire, ISI marked insulating paper, varnish, replacement of bearings two Nos. of DE and NDE etc transporting back the motor, installing on foundation, aligning the same reconnecting electrically and mechanically and testing on Full load for two hours for satisfactory functioning.
All as per Item No. 95 here-in-above but for 30HP motor.
All as per Item No. 95 here-in-above but for 25HP motor.
All as per Item No. 95 here-in-above but for 20HP motor.
All as per Item No. 95 here-in-above but for 7.5 HP motor.
All as per Item No. 95 here-in-above but for 5 HP motor.
All as per Item No. 95 here-in-above but for 2 HP motor.
Dismantling the AHU complete and taking out blower shaft for repairs and transport to workshop for weight balancing ( Dynamic ) and reassembling the complete unit including replacement of old worn out bearings, with housing & sleeves complete for following cap of central AC plant :-
20 TR to 40 TR capacity.
45 TR to 95 TR capacity.
S&F Condenser unit suitable for following cap of Package ACs :-
Suitable for upto 12 TR capacity Package AC
Taking down the old filters of any type and size from AHU/duct of Central type AC plant at MH (CTC),CH(SC), ALC and MITS&D by means of unservicing nut bolts, washers etc.including cleaning of AHU/duct as directed by Engineer-in-Charge.
S&F filters "HEPA"(Absolute)Model 131-C with fibre glass paper filtering media ,capacity 1000CFM efficiency 99.97% down to particle size of 0.3 microns aluminium frame of nominal size 24"x24"x6" or nearest as directed by Engineer-in-Charge Make:Kirloskar/Dyna.
S&F filter"Microvee" non woven fabric filter media efficiency 99.98% down to particle size of 5 microns,MS casing flanged type of nominal 24"x24"x6" or nearest Make:Kirloskar/Dyna
All as per Item No. 106 above but of size 22.5"x 22.5"x 3" or nearest size
All as per Item No. 106 above but of size 17" x 24" x 2" or nearest size. Make Dyna,Kirloskar
S&F panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 17" x 24" x 2" or nearest size. Make Dyna,Kirloskar,
S&F panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 24" x 24" x 1.8" or nearest size. Make Dyna,Kirloskar
S&F panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 24" x 20" x 4" or nearest size. Make Dyna,Kirloskar
S&F panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 42" x 26" x 2" or nearest size. Make Dyna,Kirloskar
S&F panel air filters, dry type, washable rated air flow capacity 1600 CFM efficiency 99.9% down to article size 32" x 20" x 0.2" or nearest size. Make Dyna,Kirloskar
S&F in repair V belt A-28, Make : Fenner
S&F in repair V belt A-32, Make : Fenner
S&F in repair V belt B-38, Make : Fenner
S&F in repair V belt B-39, Make : Fenner
S&F in repair V belt A-41, Make : Fenner
S&F in repair V belt B-53, Make : Fenner
S&F in repair V belt B-60, Make : Fenner
S&F in repair V belt B-73, Make : Fenner
S&F in repair V belt B-76, Make : Fenner
S&F in repair V belt B-78, Make : Fenner
S&F in repair V belt B-82, Make : Fenner
S&F in repair V belt C-82, Make : Fenner
S&F in repair V belt B-88, Make : Fenner
S&F in repair V belt B-92, Make : Fenner
S&F in repair V belt B-102, Make : Fenner
S&F in repair V belt B-105, Make : Fenner
S&F in repair V belt B-108, Make : Fenner
S&F in repair V belt B-110, Make : Fenner
S&F in repair V belt C-144, Make : Fenner
S&F framed chicken mesh with 25mmx3mm flat iron frame in corner and center with stiffners of Size with
M&L for dismantling the condenser inlet pipe and outlet pipe for opening both end plates of condenser by loosing nuts bolts.Brushing the copper tubes with the help of nylon brush to remove the scale without damaging the surface and cleaning the tube with descaling regent Dilute HCL or equivalent) for the following model :-
Compressor model AC -470, Make : Kirloskar
Compressor model SMC - 4- 65, Make : Accel
Compressor model FK - 450 & 500 Make : Kirloskar
Compressor model 05040S Make : Voltas
Compressor model DXT type Seal type
Compressor model SMC 8-65, Make : Accel
M&L for cleaning the cooling tower of any type by removing all type of fins and scraping the Fungus of fins and make up tank by applying Dilute HCL solution and drawing out including cleaning and filling with fresh water as directed and specified by Engineer-in-charge.
Taking down carefully defective /unserviceable Suction valve assembly complete from existing compressor installed at site and supply and fix new Suction valve assembly for Compressor model AC-470, Make : Kirloskar
Taking down carefully defective /unserviceable Suction valve assembly complete from existing compressor installed at site and supply and fix new Suction valve assembly for Compressor model SMC 4-65, Make : Kirloskar
Taking down carefully defective /unserviceable Suction valve assembly complete from existing compressor installed at site and supply and fix new Suction valve assembly for Compressor model SMC 8-65, Make : Accel / Saebro
Taking down carefully defective /unserviceable delivery valve assembly complete from existing compressor installed at site and supply and fix new delivery valve assembly for Compressor model AC-470, Make : Kirloskar
Taking down carefully defective /unserviceable delivery valve assembly complete from existing compressor installed at site and supply and fix new delivery valve assembly for Compressor model SMC 4-65, Make : Kirloskar
Taking down carefully defective /unserviceable delivery valve assembly complete from existing compressor installed at site and supply and fix new delivery valve assembly for Compressor model SMC 8-65, Make : Accel / Saebro
Taking down carefully defective /unserviceable Liquid line valve assembly complete from existing installed at site by cutting the line and supply and fix new Liquid line valve assembly by doing brazing/welding as directed and specified by Engineer- in- charge.
M&L for preparing existing surfaces of steel exc 10cm width or girth by scrapping rusted part and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for replacement of FRP louvers of size 1220 * 330 * 3 mm thick complete all as specified and as directed.
S&F contactor MNX 70 ,3 pole with coil voltage 230 volt AC Make L&T
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate for foundation of poles etc complete all as specified and as directed.
M&L for PCC 1:2:4 type B-2 using 20 mm graded crushed stone aggregate for coping of poles etc complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft / loose soil complete all as directed by Engineer-in-Charge.
S&F in replacement of Mild steel chequered plate 10 mm thick for ducting edges beaded if directed,holes punched included round headed screws complete all as specified and as directed by Engn-In-Charge.
S&F in replacement of Cast Iron butterfly valve of 100mm dia as per IS: 13095, having epoxy coated disc, carbon steel shaft, EPDM/nitrile rubber field replacible body lining and of approved make. including a set of MS flanges, required nos of nut & bolts complete all as directed by Engn-In-Charge.
S&F in replacement of 100 mm dia pot type strainers with copper cage and flange type complete all as per direction of Engr- in -charge.
Supply and laying in trenches/on ground, jointing, testing and commissioning in replacement of MS pipe heavy grade including all necessary pipe fittings/accessories like socket, unions, tees elbows etc of the following sizes :-
150 mm bore
100 mm bore
Maintenance and Serviceing including attending faults on day to day basis of capacity upto 1000Ltrs, oxygen plant, fully automatic with all controls, Vaccum pressure and electric motors complete including all accessories and cleaning and maintaining equipment and plant room as specified and directed. Location - MH (CTC)
Maintenance and Serviceing including attending faults on day to day basis of AC plant of 54 TR including taking down unserviceable parts, refixing new parts wherever necessary, including leak testing with nitrogen gas, ,cleaning all type of filters including all accessories, cleaning and maintaining equipment and plant room as specified and directed by Engineer in charge and testing the plant for satisfactory. Make : Kirloskar Location - CH (SC) ICU
Supply and replace in a suitable 20 way copper distributer for cooling coil of AHU for 50 TR AC plant
Caliberation micro processor system of Voltas compressor and seting the same to for smooth function of compressor and AC Plant from autherised agency Location - MH (CTC) / MITS & D
All as per item No 156 here- in- above but for AC plant Cap 35 TR Make : Accel, Location : CH(SC) OT Prepost
All as per item No 156 here- in- above but for AC plant Cap 17.5 TR Make : Accel, Location : CH(SC) New OT
All as per item No 156 here- in- above but for AC plant Cap 40TR Make : Accel, Location : MITS&D DIAC Bldg
All as per item No 156 here- in- above but for AC plant Cap 34TR Make : Accel, Location : CH(SC) lower OT
All as per item No 156 here- in- above but for AC plant Cap 3TR Make : Frizking, Location : CH(SC) Medical store
All as per item No 156 here- in- above but for AC plant Cap 80TR Make : Voltas, Location : CTC OT 1& 2
All as per item No 156 here- in- above but for AC plant Cap 50TR Make : Accel, Location : ALC OT
All as per item No 156 here- in- above but for AC plant Package type ,Cap 66TR Location : CTC ICU/ NICU
All as per item No 156 here- in- above but for Negative pressure AC plant Package type ,Cap 4TR Location : AICTS
NOTE :- (a) Spares required for the above maintenance shall be measured & paid as Supply only under appropriate items of Schedule 'A'. (b) Every day checklist as approved by Engr-in-charge has to be produced by technician giving the details of the AC plant (c) Routine checking/testing/servicing of the AC plants and Oxygen plants shall be done on weekly basis including greasing and oiling , if not Rs. 3000 will be imposed as penalty for every week & machinery missed and completion of servicing be produced to Engr-In-Charge. (d) Every day one technician has to be deployed for day to day maint and rectification of faults if any and failing which Rs.800 will be charged as penalty for every day. Technician should report attendance to Engr-in-charge. (e) Providing Gland, oil, gresaing and other neccessary items for better functioning of machinery to be provided by the contractor and cost is included in the per month maintenance of the machinery. (f) THE RATES ARE INCLUSIVE COMPLETE TESTING OF MACHINE TO THE ENTIRE SATISFACTION OF ENGR-IN-CHARGE.
S&F in repairs PVC insulated FRLS copper wire 1.5sqmm,1100V grade of colour code red,yellow ,blue,black or green laid down from motor to panel or inside panel all as specified and as directed.
S&F in repairs PVC insulated FRLS copper wire 2.5sqmm,1100V grade of colour code red,yellow ,blue,black or green all as specified and as directed.
S&F in repairs PVC insulated FRLS copper wire 4.0 sqmm,1100V grade of colour code red, yellow ,blue ,black or green all as specified and as directed.
S&F in repairs PVC insulated FRLS copper wire 6 sqmm,1100V grade of colour code red,yellow ,blue,black or green all as specified and as directed.
S&F in repairs PVC insulated FRLS copper wire 10 sqmm,1100V grade of colour code red,yellow ,blue,black or green all as specified and as directed.
M&L for painting of panels,cooling water pipe line,and other connected items ,compressors and motor of central AC plant of capacity upto 50 TR with synthetic enamel paint of approved colour after preparartion of surface complete all as specified and as directed by engineer in charge.
M&L for painting of panels,cooling water pipe line,and other connected items ,compressors and motor of central AC plant of capacity 51 to 90 TR with synthetic enamel paint of approved colour after preparartion of surface complete all as specified and as directed by engineer in charge.
M/S - SAKET ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .