Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC D NO 44 38 12 23 4 AVS PARADISE SRINIVASA NAGAR AKKAYYAPALEM POST VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.5 L+₹3.1 L (11.0%)Rejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASPURA CV RAMAN NAGAR BANGALORE 560093 | BENGALURU URBAN | KARNATAKA | 560093 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹31.7 L+₹3.4 L (11.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹32.5 L+₹4.2 L (14.7%)Rejected-Finance NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance Not Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jun 2023, 6:55 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
UPGRADATION OF CLASSROOM AND TOILETS WITH MODERN SANITARY WARE IN BUILDING NO P 35 AT DIQA UNDER GE NORTH BANGALORE
2023_MES_598296_1
8379
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Class D Category a(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹60,000
Yes
30 Jun 2023
25 May 2023
21 Jun 2023
25 May 2023
19 Jun 2023
6 Jun 2023
25 May 2023 - 6 Jun 2023
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings
Dismantling structural steel work including doors, gates but excluding framed truss etc.
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work of any description and in any position not otherwise specifically provided for complete all as specified & directed by Engineer-in-Charge.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified & directed by Engineer-in-Charge.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removing servicebale tiles to stores and rubbish off the premises complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) n. exc 1.5 sqm etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but n. exc. 4 sqm etc complete all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 deep and getting out in hard/dense soil.
Excavation in trenches in Hard/dense soil and n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc. and getting out.
Excavating in post holes (or similar holes) each in hard / dence n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Material and labour cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete etc complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete.
M&L RCC M-25 grade design mix concrete for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete
M&L RCC M-25 grade design mix concrete for Columns, pillars, piers, posts and struts
M&L RCC M-25 grade design mix concrete as in beams, cantilevers, bressum mers, lintels over 1.5m span
M&L RCC M-25 grade design mix concrete as in chajjas
M&L RCC M-25 grade design mix concrete for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Form work to sides of columns,pillers etc.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
Formwork to chullah hoods, chajjas, troughs and similar items including edges
Form work to for soffits of suspended slab, such as roof slab, floor slab landing and similar work complete all as specified.
Form work to edges / sides of shelves / slabs etc not exc 15cm width
Material and labourfor Mild steel TMT bar bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
As per item No 25 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Returning, filling in, including spreading, levelling watering and well ramming in layers, each layer not exceeding 25 cm thick complete all as specified.
Removal of surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a of level not exceeding 1.5 mtr above the starting point complete all as specified.
ATT for treating the bottom and sides of trenches at the rate of 5 Ltrs of emulsion per Sqm of surfaces area using chlorophyrphos complete all as specified.
ATT for treating the back fill in contract with foundation at the rate of 7.50 ltrs of emulsion per Sqm of vertical surfaces. (Area of the sub stracture in contact with back fill to be measured.)
ATT for treating the top surface of filled earth at the rate of 5 Ltrs of emulsion per Sqm of surface using chlorphyrophos complete all as specified.
Material and Labour for treating the soil under plinth protection at the rate of 5 ltrs emulsion per Sqm surface area using chlorphyrophs complete all as specified.
M&L for Pre-cast cement concrete block masonry, type C1 1:3:6 (using 20mm graded aggregate) set in CM 1:6 with solid blocks,exc 10cm in width and setting in mortar complete all as specified and as directed.
Material and labour for 15 mm thick cement plaster in CM 1:6 on fair/unfair faces of bricks or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified.
Material and labour for 15 mm thick cement plaster in CM 1:4 with Water proofing compound on fair/unfair faces of bricks or concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified.(WPC shall be measured and paid seperately)
Material and labour for 5mm thick in cement mortar 1:3 on ceiling on concrete surfaces and finishing the surface even and smooth (without using extra cement) complete all as specified
Supply only integral water proofing compound
S&F powder coating aluminium frame for doors, windows ventilators and partitions with one or more rebates including joining cleat for fixing etc. complete all as specified.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Chief.
S&F Solid PVC door frame (Single rebated) of size 60 mm x 30 mm made out of solid foam with homogenious fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and directed
M & L for factory made solid PVC moulded door shutter , 28 to 30mm thick (stiles) with Wood free EPS with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the foront face & 2mm plain colour PVC sheet on back face supplying and fixing in frame at site as per specification & drawing.
S&F mild steel medium weight 100 mm butt hinges for doors complete all as specified.
S&F 125 mm long aluminium alloy handles, fabricated type anodised
S&F 150 mm long aluminium anodised barrel tower bolts and extrude section and fixed.
S&F 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty/snap beading in square exc 0.5 sq. m in each pane complete all as specified and as directed.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty/snap beading in squares exc 0.5 sq. m in each pane complete all as specified
S & F stainless steel wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples.
Provn of Aluminium Deco grill of any design of (Jindal/Hindalco) including 'U' clips and necessary fixing arrangements all as specified and as directed.
M&L Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 over RCC slab
M& L for providing 3 mm thick APP modified membrane over (accessible/inaccessible) RCC roof with the following specifications :- (a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density o 0.87-0.89 Kg/Lit at 25º C on the prepared dry roof surface., providing and laying APP modified water proofing membrane reinforced with non woven polyester matt with physical prosperities as under:- (I) Membrane weight>3.8 Kg/ sqm (ii) Non woven polyester weight>160 gm/Sqm (iii) Softening point of membrane >150º C (iv) Joint tensile strength longitudinal >650 Sqm Cm at 230º C & Transverse> 450/Sq Cm (v) Tear strength - longitudinal >300N & Transverse>250 N Direction (vi) Elongation > 30 % (vii) Impermeability under water pressure > 3 Kg/Sq cm
M&L for preparation of newly plastered surfaces of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm / litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces.
M&L for preparation of newly plastered surfaces of ceiling and applying two coat of oil emulsion distemper, including one coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coat of oil emulsion distemper, including one coat of alkali resistant primer over chalk whitening complete all as specified and as directed.
Complete removal of existing treatment of any description over 10cm girth or width and applying two coat of plastic emulsion paint over a coat of primer over 1mm thickc wall care putty complete all as specified and as directed
Complete removal of existing treatment of any description over 10cm girth or width and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed
Hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M & L 100 mm thick cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base cocrete floor.
M & L providing 75mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in subbase.
M & L providing 75mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in plinth protection .
M&L for Cement concrete 40mm thick type B-1, 1:2:4 (20mm graded aggregate) as in sub floor .
M&L for Cement concrete 25mm thick type B-1, 1:2:4 (20mm graded aggregate) as in sub floor .
M&L for Sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for Rubber moulded Machine pressed precast concrete interlocking paver block with grey cement and pigments any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade complete all as specified and as directed.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including cutting polishing and including nosing laid on 15 mm thick screed bed in CM 1:4 set and jointed..
S&F Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over a screed of 20mm thick in CM 1:6 complete all as specified and as directed.
S&F 75mm dia PVC (SWR) floor/Nahani trap, plain with grating including solvent cement
S&F 75mm dia PVC (SWR) multi floor/Nahani trap, plain with grating including solvent cement
S&F PVC (SWR) 110 mm bore pipes single socketed, in any length with rubber ring joints laid in floors and fittings complete all as specified and as directed.
S&F PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints laid in floors and fittings complete all as specified and as directed.
S& F PVC bends any radius 110mm dia
S& F PVC bends any radius with access door 110mm dia
S&F PVC (SWR) 110mm, junction single, (Single T) equal or unequal
S& F PVC bends any radius 75mm dia
S& F PVC bends any radius with access door 75mm dia
S&F PVC (SWR) 75mm, junction single, (Single T) equal or unequal
S&F 32mm dia Low density polyethylene (LDPE) pipes of pressure rating 6kgf/sq. cm
S & F of CPVC pipes 20mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down of pipe of 15 mm GI pipe complete all as specified.
S & F of CPVC pipes 25mm dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking down of pipe of 20 mm GI pipe complete all as specified
S&F of 20 mm dia CPVC brass elbow complete all as specified and as directed.
S&F in repairs Bib tap cast copper alloy 15mm fancy type , Chromium plated screwed down, high pressure, with capstan head , screwed down screwed for iron pipe complete all as specified and as directed.
S&F in repairs stop valves 15 mm nominal bore, brass, chromium plated, complete, fixed in repairs, all as specified and directed .
S&F in repairs tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and as directed.
S&F in repair stainless steel soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including CI/PVC/Vitreous china 'P' or 'S' trap , 110 mm dia PVC(SWR) WC connector and 75 mm dia pipe required length for Nahani trap along with grating complete all as specifed and as directed.
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest including vitreous china 'P' or 'S' trap with providing lime concrete bedding and connecting to flusing cistern complete including breaking up existing damaged WC seat and connecting flush pipe etc and make good to floor complete all as specified
S&F in repair PVC low level flushing cistern 10 ltr capacity, valveless, syphonic action type with inlet, ball valve float and handle incl brakcet and flush pipe 32 mm dia.
Supply only plastic water closet seat cover, White, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specifed and as directed.
S&F in repairs vitreous china wash hand basin, white, oval type including one number brass CP waste coupling, waste pipe, brackets 2 numbers including cutting for and pinning in ends of brackets complete all as specified and directed.
Supply only 15 mm bore Pillar taps (self closing) , fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S&F in repairs vitreous China urinals, half stalled type white , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating, PVC waste pipe and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F in repairs Vitreous china urinal partition white of size 310x700 mm.
S&F 32mm dia Waste coupling of PTMT (half or full threaded). (Minimum weight 32mm-45gms)
S&F urinal spreader of brass chromium plated for fixing with 15 mm dia pipe.
S&F, in repairs PVC connection 15mm , 450mm long complete all as specified and as directed.
S&F,in repairs 15mm size health faucet, ABS body , with wall hook and 1 metre stainless steel braided rubber hose pipe complete all as specified and as directed. (Cat Part No of Cera F8030105 AB or equivalent in parryware / hindware / prayag)
S&F in repairs toilet paper holder of stainless steel fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.
S&F in repairs liquid soap dispesar/container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms)
S & F in repair 1000 litrs capacity water tanks Rotational moulded polyethylenewater storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and as directed.
Supply only 25 mm bore Ball valve high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete, fixed in repairs, all as specified.
S&F 20 mm bore nipple suitable for HDPE water tank. (Min wt 45 gms).
S&F in repairs gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
M&L Vitrified tiles 10mm thick (square/rectangular), light / dark shade, polished, area of each tiles 600mm x 600mm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 15 mm screed bed in CM 1:6, complete.
S&F non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed of 15mm thick in CM 1:6 etc complete all as specified and as directed.
S&F coloured Glazed ceramic tile in verticle surface 350x250x7 mm/ 450x350x7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick CM 1:4 backing coat complete all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
S&F solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing .
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240
S&F multi wall polycarbonate sheet not less than 10mm thick transparent finish plain colour as in roof covering / cladding to wall, fixed with self tapping screws / aluminium filets and sealing the joints with aluminium protective self-adhesive bituminous strip of width not less than 100mm of make STP and equivalent complete all as specified and as directed.
M&L preparation of new or previous untreated Surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
M&L Pre-cast Cement concrete Type 1:3:6 using (16 mm graded stone aggregates) with solid blocks, exc 10 cm in width and setting in CM 1:4 all as specified and directed.
M&L for cement concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid & tested for 150 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate complete all as specified and directed.
M&L Reinforced concrete pipes, class NP3,150 mm dia bore of pipe laid and jointed complete with collars complete all as specified and directed by Engr-in-charge
M&L for PCC 1:2:4 type B-2 with using 12.50 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings, Chajja kerbs, roof padding/staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
Mild Steel TMT bar 6 to 8mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
Point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for the following :- (a) One light point controlled by one switch
As per item No. 122 above but for One fan / exhaust point controlled by one switch / regulator
As per item No. 122 above but for One 3 pin socket out let 5 Amps on independent board
As per item No. 122 above but for One bell / buzzer point controlled by bell push
As per item No. 122 above but for One 3 pin socket out let 5 A on same board
Point wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 1 to 2 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
S&F LED batten suitable for indoor applications 18/20 Watts, 4 feet with extruded aluminium housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. Make: Bajaj, Cat No.BCLAB 18 WH LED P or equivalent Makes & model in Havells / CG.
S&F LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel rectangular white arcylic cover complete with all accessories all as specified and directed. Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes & model in Havells / CG.
S&F 2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZi WH or equivalent Makes & model in Havells / Philips / CG.
Supply and Fix Modular switch 1 way 6A,1 module
Supply and fix Modular switch 1 way 16A, 1 module
Supply and fix Modular switch 2 way 6A,1 module
Supply and Fix Modular Bell push 6A 1 module
Supply and fix modular Socket, 6A - 2/3 pin combined 2 module
Supply and fix modular Socket 6A/16A - 2/3 pin combined 2 module,
Supply and fix modular type Fan step regulator, 120W - 2 module
S&F Switch piano flush button single pole two way 5 Amps all as specified and as directed.
S&F of Angle holder PVC/polycarbonate type all as specified and as directed
S&F MCB SPN 240 volts 32 Amps complete all as specified and as directed
S&F MCB single pole 240 volts 6 to 32 Amps complete all as specified and as directed
S&F MCB TPN 415 volts 63 Amps complete all as specified and as directed
S&F MCCB 4 pole 415 volts 100 Amps 16 KA, fixed type including taking out old unserviceable MCCB complete all as specified and as directed
S&F MCB DB SPN 8 way double door type 240 volts with 200 Amps rated busbar as specified and as directed.
S&F Vertical DB TPN 6 way suitable for MCCB upto 125 Amps as I/C, double door type 415 volts, IP :54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly Make:- INDOASIAN Cat No. 812041.
S&F ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F Ding Dong bell AC 230 volts single pole.
M&L for provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with one run of 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through suitable size PVC conduit all as specified and as directed. Note :- 3 runs of cable and one run of conduit will be measured as unit length.
M&L for provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with one run of 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through suitable size PVC conduit all as specified and as directed. Note :- 3 runs of cable and one run of conduit will be measured as unit length.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion incl earth work and excavation in any type of soil PCC (1:3:6) type C1 chamber, pre cost slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia MS bars reinforced at 10 cm centre to centre both ways incl funnel with watering pipe wire mesh and lugs, incl test point complete all as specified and as directed.
S&F 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes & model in Havells / CG.
S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
S&F Single pole & neutral enclosure 20 Amps & 240 V with two pin and earth plug and socket complete with one single pole MCB 20Amps
S&F energy saving ceiling fans, 230 volts, 26 watts, single pole, 1200 mm sweep, high speed of approved colour with remote control and two years warranty certificate from the manufactures, with latest BEE five star rating and BLDC technology all as per Havells Model No:- Efficiencia Neo (BLDC 26W) or techno commercially equivalent models specified in Bajaj / CG / Havells complete with sutibale GI down rod and GI hook with welding work, wire connections from ceiling rose to ceiling fans with complete accessories including writing of MES NO with unit name on ceiling fans using approved stencil with synthetic enamal paint complete all as specified and directed.
S&F Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc all as directed. Make : Bajaj cat No : 70079, MAXX AIR or eqv in Make Havells/CGs/ Orient
Dismantling of existing electric panel from wall after disconnecting of all electric cable and refixed at other location all as directed.
M & L for sand cushioning with a layer of river sand 23 cm thick under and above the cable complete all as specified and as directed
S & L sub class burnt bricks for cable protection complete as specified as directed
S&L XLPE insulated, screened, PVC bedded, galvanised steen strip or wire armouned power cables (heavy duty) with aluminium conductor, 1100 volts grade, cross sectional area 50 Sqmm, 4 core laid in trenches/wall..
S&F GI tubing light grade 50 mm bore with all fitting laid in trenches / walls / Roads for cable protection .
Aavani BUILDERS AND CONTRACTORS
SAI CONSTRUCTIONS
Shanthi Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .