Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.6 LQualified Make: Prasha Leypower
Model: PRASHA LEYPOWER & LP125D IMT GURUGRAM HARYANA 122050 | GURGAON | HARYANA | 122050 | Make: Prasha Leypower
Model: PRASHA LEYPOWER & LP125D | L1 | Qualified | |
| 2 | L2₹8.6 L+₹800 (0.09%)Qualified Make: Koel Green Electro
Model: KOEL GREEN KG1-125WS3 WITH PART NO. 318177-3212 20 23 BHAGWANPUR RAIPUR SAHKARI AUDYOGIC KSHETRA HARIDWAR UTTARAKHAND 247661 | HARIDWAR | UTTARAKHAND | 247661 | Make: Koel Green Electro
Model: KOEL GREEN KG1-125WS3 WITH PART NO. 318177-3212 | L2 | Qualified | |
| 3 | L4₹8.7 L+₹16,026 (1.87%)Qualified Make: Mahindra Powerol-Perfect
Model: Mahindra 125 KVA MECH CPCB II GANDHI NAGAR DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | Make: Mahindra Powerol-Perfect
Model: Mahindra 125 KVA MECH CPCB II | L4 | Qualified | |
| 4 | L5₹8.8 L+₹21,999 (2.57%)Qualified Make: Mahindra
Model: MAHINDRA 125KVA MECH CPCB2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: Mahindra
Model: MAHINDRA 125KVA MECH CPCB2 | L5 | Qualified | |
| 5 | Qualified Make: ASHOK LEYLAND - CSH
Model: ASHOK LEYLAND (CSH-125-3P-AMF-INSTALL) 12A CSH POWER HIMOINSA P LTD SIDCUL SECTOR 9 IIE RUDARPUR UDHAM SINGH NAGAR UTTARAKHAND UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | Make: ASHOK LEYLAND - CSH
Model: ASHOK LEYLAND (CSH-125-3P-AMF-INSTALL) | - | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
18 Jun 2018, 8:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 125 125
125.0 No of Phase - Single phase
Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic Class of governer A2 A0
A1
A2 Number of cylinders (nos) 6 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 10 - 1/4 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 125 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 92.8 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6
1.8
2
1.2 Thickness of Foam 50 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 JAGPAL SINGH 110033
Agricultural Produce Marketing Committee New office Complex
New Fruit Market Phase-II
Sarai Pipal Thala
Azadpur 1 21 EMD Required No ePBG Required No
199707
GEM/2018/B/28436
diesel generators- DG Sets
21 days
Delhi; North Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 125 125 | - | - | - |
| 125.0 No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic Class of governer A2 A0 | - | - | - |
| A1 | - | - | - |
| A2 Number of cylinders (nos) 6 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 10 - 1/4 hours continuous running at full load (%) Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 125 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 92.8 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 50 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number and date(Engine) - - 2/4 Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 JAGPAL SINGH 110033 | - | - | - |
| Agricultural Produce Marketing Committee New office Complex | - | - | - |
| New Fruit Market Phase-II | - | - | - |
| Sarai Pipal Thala | - | - | - |
| Azadpur 1 21 EMD Required No ePBG Required No | - | - | - |
Exempted
18 Jun 2018
12 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_199707.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .