| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.4 CrAccepted-AOC HOUSE NO 44 MASTER COLONY SATROD KHAS HISAR HARYANA 125044 | HISAR | HISAR | HARYANA | 125044 | ₹1.4 Cr | L-1 | Accepted-AOC Being L-1 |
| 2 | L-2₹1.5 Cr+₹6.0 L (4.28%)Rejected-AOC | ₹1.5 Cr+₹6.0 L (4.28%) | L-2 | Rejected-AOC Other than L-1 |
| 3 | L-3₹1.6 Cr+₹20.2 L (14.5%)Rejected-AOC 6146 HIRA CHOWK SIRKI BAZAR BATHINDA PB 151005 | BATHINDA | PUNJAB | 151005 | ₹1.6 Cr+₹20.2 L (14.5%) | L-3 | Rejected-AOC Other than L-1 |
| 4 | L-4₹1.9 Cr+₹53.3 L (38.3%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹1.9 Cr+₹53.3 L (38.3%) | L-4 | Rejected-AOC Other than L-1 |
| Sl No | Description | Qty | Unit | Parveen Builders L2 | R B TRADERS L4 | m/s AR Construction co L1 | B B BUILDERS L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specfied and as directed by Engineer-in-Charge. | 10 | EACH | 50 ₹500 Lowest | 250 ₹2,500 | 100 ₹1,000 | 50 ₹500 Lowest |
| 2.00 | Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specfied and as directed by Engineer-in-Charge. | 2,060 | SQM | 10 ₹20,600 Lowest | 40 ₹82,400 | 10 ₹20,600 Lowest | 10 ₹20,600 Lowest |
| 3.00 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge. | 20 | CUM | 100 ₹2,000 Lowest | 500 ₹10,000 | 200 ₹4,000 | 250 ₹5,000 |
| 4.00 | M&L for Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specfied and as directed by Engineer-in-Charge. | 20 | CUM | 4,500 ₹90,000 | 5,500 ₹1,10,000 | 4,000 ₹80,000 | 3,500 ₹70,000 Lowest |
| 5.00 | M&L for Rendering 10 mm thick on brick work or concrete surfaces on walls in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specfied and as directed by Engineer-in-Charge. | 640 | SQM | 180 ₹1,15,200 Lowest | 300 ₹1,92,000 | 220 ₹1,40,800 | 180 ₹1,15,200 Lowest |
| 6.00 | M&L for 15 mm thick rendering in Cement and Sand mortar 1:4 upto 04 storey bldg on fair faces of brick work or concrete surfaces finished fair and even, including scaffolding & necessary safety arrangements, (For Shaft & facia repair) using filler with Integral water proofing liquid admixture as per manufacturers instruction complete all as specfied and as directed by Engineer-in-Charge.
Note :- filler & WPC compound will be paid separately. | 1,590 | SQM | 200 ₹3,18,000 Lowest | 550 ₹8,74,500 | 250 ₹3,97,500 | 240 ₹3,81,600 |
| 7.00 | Supply only filler for cement plaster and concrete, complete all as specfied and as directed by Engineer-in-Charge. | 500 | KG | 40 ₹20,000 Lowest | 90 ₹45,000 | 60 ₹30,000 | 50 ₹25,000 |
| 8.00 | M&L For Preparation of newly plastered surfaces and applying wall care putty, not less than 2 mm thick over a coat of primer including smoothening the surfaces with sand papers etc., and applying two coats of Interior emulsion on wall surfaces as per manufactuer's instructions complete all as specfied and as directed by Engineer-in-Charge. | 640 | SQM | 90 ₹57,600 | 150 ₹96,000 | 70 ₹44,800 Lowest | 120 ₹76,800 |
| 9.00 | Complete removal of existing treatment on wall and applying 1 mm thick wall care putty on wall surfaces & smoothening the surfaces with sand papers etc., (preparatory to OBD/ plastic emulsion/ interior emulsion paint as directed), of any description complete all as specfied and as directed by Engineer-in-Charge. | 5,000 | SQM | 35 ₹1,75,000 | 80 ₹4,00,000 | 25 ₹1,25,000 Lowest | 40 ₹2,00,000 |
| 10.00 | Material and labour for preparation of old surfaces of walls and applying two coats of plastic (interior) emulsion paint complete all as specfied and as directed by Engineer-in-Charge. | 25,000 | SQM | 60 ₹15,00,000 | 100 ₹25,00,000 | 45 ₹11,25,000 Lowest | 60 ₹15,00,000 |
Tender Value
₹1.6 Cr
EMD Value
₹2.4 L
Closing Date
25 Sept 2025, 6:00 pmClosed
CWE Chandimandir
HQ CWE Chandimandir, PIN-134107
CWE/CHM-63/2025-26 SPECIAL REPAIR TO WINDOWS, EXTERNAL SURFACES AND PLINTH PROTECTION IN BLDG NO P-624 AND REPLACEMENT OF INTERNAL ELECTRIC WIRING ALONGWITH CONNECTED ACCESSORIES IN BLDG NO P-935 IN APS AT CHANDIMANDIR MIL STN.
2025_MES_721042_1
CWE/CHM-63/2025-26
Open Tender
Civil Works
Item Rate
270 days
GE Chandimandir
Class B, Cate a(i)
9 documents required · 9 mandatory
₹1,000
GE Chandimandir
₹2.4 L
13 Oct 2025
18 Jul 2025
2 Oct 2025
18 Jul 2025
25 Sept 2025
6 Sept 2025
18 Jul 2025 - 24 Jul 2025
Amount
Taking down chowkhats or frame exc 1.5 Sqm but n.exc 4 Sqm with shutter (without taking off shutters from the frame) and removal from site complete all as specfied and as directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specfied and as directed by Engineer-in-Charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class 'B' Bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specfied and as directed by Engineer-in-Charge.
M&L for Rendering 10 mm thick on brick work or concrete surfaces on walls in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specfied and as directed by Engineer-in-Charge.
M&L for 15 mm thick rendering in Cement and Sand mortar 1:4 upto 04 storey bldg on fair faces of brick work or concrete surfaces finished fair and even, including scaffolding & necessary safety arrangements, (For Shaft & facia repair) using filler with Integral water proofing liquid admixture as per manufacturers instruction complete all as specfied and as directed by Engineer-in-Charge. Note :- filler & WPC compound will be paid separately.
Supply only filler for cement plaster and concrete, complete all as specfied and as directed by Engineer-in-Charge.
M&L For Preparation of newly plastered surfaces and applying wall care putty, not less than 2 mm thick over a coat of primer including smoothening the surfaces with sand papers etc., and applying two coats of Interior emulsion on wall surfaces as per manufactuer's instructions complete all as specfied and as directed by Engineer-in-Charge.
Complete removal of existing treatment on wall and applying 1 mm thick wall care putty on wall surfaces & smoothening the surfaces with sand papers etc., (preparatory to OBD/ plastic emulsion/ interior emulsion paint as directed), of any description complete all as specfied and as directed by Engineer-in-Charge.
Material and labour for preparation of old surfaces of walls and applying two coats of plastic (interior) emulsion paint complete all as specfied and as directed by Engineer-in-Charge.
Material and labour for preparation of old surfaces of ceiling and applying one coat of oil bound distemper, complete all as specfied and as directed by Engineer-in-Charge.
M&L for preparation and applying Water based premium acrylic smooth exterior emulsion on new surfaces of approved colour with silicon additive excellent dirt pickup resistance with low VOC less than 50, Antifungal/ Anti Algae properties in two coats @ 1.79 litre (undiluted)/ 10 Sqm diluted with water as per manufacturer's instructions applied over primed surface with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in between subsequent coats of paint complete all as specified and directed.
Note : The work for periodical services shall include the following and the rates quoted by the bidders shall include the same :- (a) The work pertaining to periodical services shall be executed by the contractor as per MoU from authorised applicator through manufacturer of the materials like Exterior Emulsion paint, putty etc after approval by the GE. (b) The Contractor shall upload with the documents under cover I "Memoradum of Understanding" (MOU) with at least one of the manufacturers mentioned in the contract, failing which the bid shall be laible to be rejected. (c) Use of Scaffolding, trestles, ladders, cradles etc necessary for execution of work and protective measures. (d) Removing of Nails, making good holes, cracks etc and preparation of surfaces. (e) Work in patches and in narrow/ widths, bands, cornices, pilasters etc and cutting in edge of line where necessary.
(f) Spreading and removing covering to doors, windows, floors, fittings etc to protect them from splashes. (g) Washing floors, cleaning glass, joinery, electric fittings, wirings etc. Drops and splashes of paint to be cleaned to the entire satisfaction of Engineer-in-Charge. (h) Sample patch of 10 Sqm shall be prepared considering all the items of periodical and shall be got approved from GE prior to carrying out further work.
All as per serial item no 12.00 here-in-Above above but on Old surface complete
M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide oxide primer complete all as specified and as directed by Engineer-in-charge.
M&L for Preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
M&L for Preparation of old wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge.
Supply and fixing factory made steel windows (Box type) with glazing bars, dovetailed or welded including hinges, steel handles, steel peg stays etc fixed including taking down old window and finished smooth and fair surface complete all as specified and as directed by Engineer-in-charge.
M&L for flush pointing on brick/ concrete tiles in paving/ roofs laid flat, in CM 1:3 including racking out joints/ pointing in floor/ roof and removal of all grass root small trees etc. complete all as specified and as directed by Engineer-in-charge.
M&L for Cutting down small trees/ bushes from wall/ roof/ chajja of building including digging out the roots from brick work or any other structure portion of building including applying root killer chemical as per manufacturer instructions and making good the disturbed portion to match the existing surface complete all as specified and as directed by Engineer-in-charge.
Demolition of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar complete all as specified and as directed by Engineer-in-charge.
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part there of, complete all as specified and as directed by Engineer-in-charge.
M&L for PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggegate) 40 mm average thickness cement concrete as in roof padding, with mixing water proofing compound complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering 10 mm thick plaster in CM 1:4 mixed with water proofing compound on concrete surface when concrete is green as per manufactuer's instructions complete all as specified and directed by Engineer in Charge. Note :- WPC shall be measured and paid seperately.
Supply only Integral water proofing liquid admixture, ISI Marked, complete all as specified and directed by Engineer in Charge.
M&L for APP based polymeric membrane minimum weighing 3 kg/ sqm and minimum 3 mm thick reinforced with polyester non woven fabric (weight not less than 150 gm/ sqm) laid on primed surface by torch application (including bituminous primer) as per manufactuer's instructions including cleaning, wire brushing and dismantling of existing felt complete all as specified and as directed by Engineer-in-charge.
M&L for Cement concrete tiles 25 cm x 25 cm x 22 mm thick, with grey cement and no pigments machine pressed set jointed and pointed in neat cement slurry in floors, and cut and polished laid on 15 mm thick cement mortar (1:3) complete all as specified and as directed by Engineer-in-charge.
Supply only Universal Repair Polymer chemical for mixing in cement mortar as treatment to efflorescence complete Make :- Dr Fixit/ Pidilite or equivalent as approved by GE.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc. complete all as specified and as directed by Engineer-in-charge.
S&F PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed by Engineer-in-charge.
S&F PVC (SWR) bend, Tees 110 mm bore fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 100 mm bore CI centrifugally cast spun soil waste and vent pipes in any length, with or without ears with lead joints fixed to walls, fixed as in repair complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 31.00 here-in-above but of 75 mm bore of pipe
Supply and fixing 100 mm bore CI centrifugally cast spun soil waste and vent pipes in any length with or without ears with lead joints laid in trenches or in floors, fixed as in repair complete all as specified and as directed by Engineer-in-charge. Note: Excavation and earth work shall be measured and paid for separately under respective items of this schedule.
All as per serial item No 33.00 here-in-above but of 75 mm bore of pipe
Supply and fixing 100 mm bore CI centrifugally cast spun, branch pieces equal or unequal or inverted (spigot socketed type or with parallel branches fitted with oval excess door), or Tees fixed as in repair complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 35.00 here-in-above but of 75 mm bore
Supply and fixing CI centrifugally cast spun bends (any radius), diminishing pieces or tapers (largrer bore measured), suitable for 100 mm bore spun pipes, ISI marked, fixed as in repair complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 37.00 here-in-above but of 75 mm bore
S&F of stack clamps for 100 mm bore pipe, made out of 30 mm x 5 mm size, flat iron round stays, including screws/ nails and securing ends of stays to wall or roof, fixed as in repair complete all as specified and as directed by Engineer-in-charge.
All as per serial item No 39.00 here-in-above but of 75 mm bore
Excavation in trenches in soft/ loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre width and getting out soil for laying cables/ pipes etc. complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in (soils) including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus excavated spoil (Soils) not exceeding 50 metre distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed Engineer-in-Charge.
Demolition of stone slabs of any description in floors laid, bedded and pointed in any mortar complete all as specified and as directed by Engineer-in-charge.
Demolition of cement concrete (un-reinforced) in ground floor and paving n exc 15 mm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed by Engineer-in-charge.
M&L for plinth protection 50 mm thick in cement mortar 1:3:6 type C-2 finishing cement concrete fair & even without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L machine cut kota stone slab 20-25 mm thick for stairs and corridor over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing upto Granite/mirror finish complete over and including 15mm thick screed bed in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L machine cut kota stone slab 20-25 mm thick for skirting/dados of stairs and corridor over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing upto granite/mirror finish complete over and including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L for rubber moulded Chequered cement concrete tiles any size from 300 mm x 300 mm or 400 mm x 400 mm and 25 mm thick as reqd), set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over 15 mm thick screed in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M&L taking down, chipping and removing the loose spailt, damaged cement concrete, cement mortar surfaces of RCC beams, chajjas etc and exposing the reinforced cement concrete, wire brushing and cleaning the exposed steel reinforced bar, apply rust remover over the cleaned re-bar surface, wash with clean water for removing all rusts from the old reinforcement bar surfaces, fixing new reinforcement for strenghten the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified cement and quartz sand mortar in CM 1:3 mix, 40 mm average thick in two coats, with and including polymer @10 % by weight of cement including erecting and dismantling steel scafolding for carrying out the work upto height of 10 m (approx.) complete all as specified and as directed by Engineer-in-charge. Make: Dr fixit/ sunanda/ chemestik/ fosrock.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm and 45 x 85mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) Complete all as specified as per Manufacturer broucher.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge.
M&L for 100 mm Butt hinges, extruded aluminium alloy with stainless steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed by Engineer-in-charge.
Taking up or down GI steel/ Kitek tubing 15 mm with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-charge.
Taking up or down GI steel/ Kitek tubing 20 mm with connections or fittings from wall, ceiling, floor etc., complete all as specified and as directed by Engineer-in-charge.
Supplying and laying 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed by Engineer-in-charge.
Supplying and laying 25 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches ccomplete all as specified and as directed by Engineer-in-charge.
S&F in repair 15 mm fancy type Chromium plated angle valves/ stop valve cast copper alloy, screwed down high pressure with crutch both ends for iron pipes or for union and fixed complete all as specified and as directed by Engineer-in-charge.
S&F in repair 15 mm bore Pillar taps, fancy type, swan neck, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe, 20 mm bore complete all as specified and as directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe, 15 mm bore complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Material and labour for Vitrified Ceramic tiles 10 mm thick First quality (square/ rectagular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
Material and labour for glazed ceramic tiles in vertical surface 350 x 450 x 7 mm thick or 300 x 450 x 7 mm, joint free, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over 10 mm thick rendering in cement mortar 1:4, complete all as specified and directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-charge.
Material and labour for framed work such as grills, grating, framed guard bars for doors & windows, walk ways, railings etc. using steel conforming to Fe-290 fixed as in repair complete all as specified and directed by Engineer-in-charge.
S&F of Mild Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St-240, complete all as specified and directed by Engineer-in-charge.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings and sunshades complete all as specified and directed by Engineer-in-charge.
S&F of Pre-painted galvalume aluminum zinc coating GI based curved corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall/ sunshades, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Cutting chases, pinning in, brick/ stone walls exceeding 10 cm but not exceeding 20 cm girth, including making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, inserting APP, for concealed water tubing or concealed conduit wiring etc complete all as specified and directed by Engineer-in-charge.
Cutting holes in brick walls built in cement mortar, with embedded depth of holdfast not exceeding half brick thick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, Type B-1 as required complete all as specified and directed by Engineer-in-charge.
S&F of aluminium sections/ tubing for ACP framework and in frames/ shutter of doors/ window/ ventilators/ partitions (Sliding/ openable) including joinging cleats, glazing clips, silicon filling, rubber neoprene beading, snap beading, screws etc. also including necessary scaffolding arrangement upto 12 metre height complete all as specified and directed by Engineer-in-charge.
Note : (i) Weight of aluminum section only shall be measuerd and paid. (ii) The rate shall be inclusive of silicon, beadings, screws, scaffolding etc. Weight of fitting fixtures will not be measured for arriving the weight of aluminum section. (iii) Design as directed by Engineer in charge.
S&F for 3 mm thick exterior aluminium composite panel sheet (ACP), including necessary scaffolding arrangement upto 12 mtr height, colour as approved by Engineer-in-Charge all as specified and as directed.
Dismantling of wall and ceiling board (timber, pulp execution etc), any thickness including removing from site complete all as specified and directed by Engineer-in-charge.
Material & labour for solid WPC (wood polymer composite) board, 25 mm thick interior grade, pre-laminated one side, fixed with screws as in shutters of cup boards and kitchen cabinets, complete all as specified and directed by Engineer-in-charge.
S&F for continous (piano) hinges, mild steel bright finish width of flap 40 mm, fixed as in repair complete all as specified and directed by Engineer-in-charge.
S&F magnetic cathcher for kitchen cabinet/ cupboard fixed as in repair complete all as specified and directed by Engineer-in-charge.
Material and labour for 150 mm long Stainless steel handles, fancy type anodized, fixed as in repairs complete all as specified and directed by Engineer-in-charge.
Taking down copper/ aluminum point wiring for (light, fan, socket point 5/15 amps) complete including fitting such as switches, ceiling rose, light fittings, sockets, bulb holder, ceiling roses etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors etc complete all as specified and as directed by Engineer-in-Charge.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm, 1100 volts grade for earth continuity conductor to common earth and connected to earth dolly, including new conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light/ bell/ buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator, complete all as specified and as directed by Engineer-in-Charge.
All as per serial item 81.00 here-in-before but for socket outlet 3 pin 5 Amps on same board complete all as specified and as directed by Engineer-in-Charge.
All as per serial item 81.00 here-in-before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and as directed by Engineer-in-Charge.
All as per serial item 81.00 here-in-before but One socket outlet three pin, 6/16 Amp, independent board, with 2.5 Sqmm (nominal area) FRLSH cable & 2.5 Sqmm (nominal area) cable as earth continuity conductor complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 6 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular switch, one way, 16 Amps, one module, 230 volts, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet, 2 in 1, 3/5 pin, 6 Amps, two module 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular socket outlet, 2 in 1, 6/16 Amps, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F modular fan regulator, single pole, one module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F Modular bell push, single pole, one module, 230 V complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite 65 x 50 mm dia three terminal complete all as specified and as directed by Engineer-in-Charge.
S&F electric bell, AC 230 volt, single pole complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp holder insulated body PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed by Engineer-in-Charge.
S&F LED Lamp, 9W, B22 type complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fitting and fixtures such as tube lght fittings etc for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for use) complete all as specified and as directed by Engineer-in-Charge.
Fixing only LED Lights fitting 1 X 10/ 18 / 20W, 220V AC decorative box type with driver holderincluding LED tube light connecting up withTWO core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
M&L for Disconnection of power supply and taking down carefully by old unscrewing from boards fitting and fixture such as MCB DB, junction box, panels of any size complete with all MCCB's, MCB's etc and removing from site, complete all as specified and as directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosures for MCB DB SPN 240 volts, 4 way double door fitted with 200 amps bus bar, neutral link, earth bar and din rail complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosures for MCB DB SPN 240 volts, 8 way double door fitted with 200 amps bus bar, neutral link, earth bar and din rail complete all as specified and as directed by Engineer-in-Charge.
S&F sheet metal enclosures for MCB DB SPN 240 volts, 12 way, double door fitted with 200 amps bus bar, neutral link, earth bar and din rail complete all as specified and as directed by Engineer-in-Charge.
S&F for MCCB 4 pole, 3 phase 415 volts of capacity 125 Amps, 16 KA with adjustable thermal and magnetic release complete with proper cooper thimble connection complete all as specified and as directed by Engineer-in-Charge.
S&F vertical TPN distribution board double door flush mounting with provision for MCCBs incomer upto 125 Amp, 415 volts & outgoing 4 way having IP43 protection complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SPN, 32 Amp, 230 volts, having breaking capacity 10KA "C" type complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SPN, 40 to 63 Amp, 230 volts, having breaking capacity 10KA "C" type complete all as specified and as directed by Engineer-in-Charge.
S&F MCB, SP, 6 to 32 Amp, 230 volts having breaking capacity 10KA "C" type complete all as specified and as directed by Engineer-in-Charge.
S&F in repair LED light fitting 1x 9W/ 1x 10W bulkhead luminaries including LED light driver connection up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F in repair SLIM LED batten with polycarbonate housing and diffuser with elegantly desinged end caps 1 x 20W, 220 V, AC connecting up with three core flexible of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
S&F in repair LED light fitting, mirror type with high output diffuser, 2 feet 10 watt, 220 volts, AC decorative box type with driver, holder including LED tubelight connection up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge.
Disconnection and Taking down carefully copper/ aluminium sub main wiring including PVC conduit pipe of any size and any type complete all as specified and as directed by Engineer-in-Charge.
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 4.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 4.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 6.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 6.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
M&L of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 10.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note for Serial item no. 111 to 113: 1. Two runs of cable, one run of earth wire and one run of PVC non metalic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
M&L of Sub main wiring with four runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLSH) cable of size 10.0 sqmm, LT, 1100 Volts grade, drawn through and including adequate size PVC non metallic conduit of 25 mm/ appropriate dia with accessories and fittings and one run of 10.0 sqmm single core multi stranded copper conductor cable as earth continuity conductor with accessories and fittings and connecting to existing main switch board/ DB and testing on completion complete all as specified and as directed by Engineer-in-Charge.
Note: 1. Four runs of cable, one run of earth wire and one run of PVC non metalic conduit shall be measured as one run length. 2. Cable required for connection to DBs shall deemed to be incl in the quoted rates and shall not be measured separately. 3. Earth wire shall run inside the conduit pipe.
M&L for earthing complete with galvanised steel eath plate electorde 60x60x0.6 cm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) connected to galvanised earth lead wire 4 mm dia by means of GI bolts nuts, check nuts washer of galvanised iron or steel all as shown in electric plate No 3 of MES SSR Part-I and including excavation & earth work in any type of soil, disposal of soil,providing alternate layers of charcoal and common salt , construction of PCC earth chamber in mix (1:3:6) type C-I with 40 mm thick RCC 1:2:4 type B-J cover reinforced with 8mm dia MS bars both ways with lift hook made out of 8mm dia bar, watering pipe of 20 mm dia GI light grade and 15 mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and as directed by Engineer-in-Charge. Note: GI wire and earthing lead protection pipe upto 7.5 metre length from main earthing to test point shall be included in the quoted rates against this item.
S&F LED street light fitting, 35 watt LED, 230 volts, outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp including bracket up to 1.5 metre length as per suitable for fitting including clamps, GI bracket with impact and corrosion resistant including thermal management in multiple cptics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
S&F LED Recess mounted/surface mounted ultra slim 2' x 2', 36 watts, edge lit tile in aluminium extruded housing with full opal diffuser suitable for perfect lighting complete including cutting hole of required size in POP/ false ceiling including making good of disturbed surface including taking down any type ceiling fitting complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED flood light, 70 watt, 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed by Engineer-in-Charge.
S&F earth continuity conductor on main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or any other indicated situation for loop earthing 4 mm dia galvanized iron or steel wire complete all as specified.
Parveen Builders (BID ID -3424140)
B B BUILDERS (BID ID -3424685)
R B TRADERS (BID ID -3435526)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .