Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹23.6 L+₹3.5 L (17.2%)Rejected-Finance P 45 KHIRODE VIDYA BINOD AVENUE KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹24.7 L+₹4.5 L (22.6%)Rejected-Finance 60 4 MOTILAL GUPTA ROAD KOL 700008 | KOLKATA | WEST BENGAL | 700008 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹25.7 L+₹5.5 L (27.5%)Rejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.3 L+₹17.2 L (85.2%)Rejected-Finance 72 A ABINASH CHANDRA BANERJEE LANE KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
8 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF EXTERNAL LIGHTING WITH CONNECTED WORK AT INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2024_MES_638101_1
8213/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹79,000
31 Mar 2024
18 Jan 2024
9 Feb 2024
18 Jan 2024
8 Feb 2024
1 Feb 2024
Amount
Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables, poles, stay and getting out of excavated material complete all as specified and directed by Engineer-in-Charge
Excavation in Trenches exc. for each additional 1.5m or part thereof in depth beyond the first 1.5 m for laying of steel tubular pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Excavation of trench in road/hardstanding etc, not exc 1.50 m wide and not exc 1.50 m deep and getting out complete all as specified and directed.
M&L for sand cushioning as per para 19.75 of SSR Part-I(2009) in trenches for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed by engineer-in-charge. NOTE: Punned thickness only shall be measured for payment.
Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge
M&L for Brick protection with subclass ‘B’ bricks old size, laid dry, flat over cable perpendicular across the cable in trenches complete all as specified.
Laying Only Serviceable Bricks after cleaning by wire brush obtained from taking out unserviceable LT cable in connected items here-in-after.
Taking out of interlocking paver block, any shape or size and Re-laying the same after removing all vegetation, algae, grass etc, laid to proper slope & gradient over sand cushioning complete all as specified and directed. (NOTE: Sand, if required for correction of cushioning level will be measured and paid separately. Replacement of broken paver block shall be paid separately as "Supply only")
Material and labour for machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS 15658-2006 of 60 mm thickness, M-35 grade complete all as specified and directed.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) incl necessary aluminium thimbles, jointing and testing complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 35 Sqmm, 3.5 core
Supply, Laying, jointing and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm, 4 core
16 Sqmm, 4 core
25 Sqmm, 4 core
35 Sqmm, 3.5 core
Taking out existing unserviceable/ defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of checking out the defects, trace out damage/ unserviceable parts like driver, wire, led lamp etc and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing complete all as specified and as directed by Engr-in-Charge. Note :- (a) Any minor item like nuts, bolts, clamps, washers and wires for connection is required to make the fitting serviceable are deemed to be included in the quoted rate. (b) Defective parts replaced against relevant items shall be paid under supply only item.
M&L for replacement of electronic driver with input voltage 220 to 240 volts and output voltage suitable for different LED of luminaires, complete all as specified and directed for the following types and capacities:-. (NOTE: Make of driver shall be as OEM or any other make as specifically approved by GE)
35/36 watt street light luminaire
40/45 watt street light luminaire
60/70 watt street light luminaire
80/90 watt street light luminaire
100/120 watt street light luminaire
30 watt flood light luminaire
50 watt flood light luminaire
60 watt flood light luminaire
80 watt flood light luminaire
100/110 watt flood light luminaire
120/130 watt flood light luminaire
150-160 watt flood light luminaire
180-200 watt flood light luminaire
9-12 watt bollard
20.50 watt post top lantern
Material and labour for brick work with locally available sub class ‘B’ old size best quality bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:4) all as specified and directed.
M&L for replacement of Pole Mounted Junction Box 254 x 180 x 111mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, 'B' Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No. TKPS 2518 - 11M or HENSAL cat Pt No. KF 2525B or equivalent SPELSBERG/RITTAL/SCHNEIDER
Supply and fixing cable Junction box of size 182 mm x 180mm x 67mm weather proof, IP 65 for outdoor installation including 05 Nos terminals fixing on wall with suitable size anchor bolt etc. with MCB SP, 6 Amps, 240 volts, 50 Hz - 01 No. as in repairs, complete all as specified and directed. Make:CAPE Cat Pt No. 806 407 01 or equivalent in HENSEL/ SPELSBERG/ RITTAL/ SCHNEIDER
S&F in replacement of PVC insulated multistranded copper conductor wire, 1.5 Sqmm 3 Core, round flexible for connection of light fittings, complete all as specified and as directed.
Material and labour for applying three coats of white wash on walls including preparation of new or previously untreated surfaces all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on other than fair face of brick or concrete surface finished even and fair all as specified and directed.
S&F in repairs LED Street Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
35/36 Watt Street Light Luminaire
60/65 Watt Street Light Luminaire
60/65 Watt Street Light Luminaire
S&F in repairs LED Flood Light fitting, of various capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver and toughened glass cover, IP66 grade ingress protection, impact resistance IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
70 Watt Flood Light Luminaire
120 Watt Flood Light Luminaire
180 Watt Flood Light Luminaire
S&F in repairs LED Highbay luminaire 150 Watt (with system lumen efficacy 130 lumen /watt), circular shape, of various capacity as mentioned under, in high pressure die cast aluminium/LM6 alloy housing with secondary modular lens optics and toughened glass cover with integrated constant current electronic driver, IP66 ingress protection complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 130 lumen/watt (b) CRI not less than 80, (c) THD < 10% (d) Power factor not less than 0.90 (e) having in built short circuit and surge protection upto 5 kV (f) colour temperature not less than 5700 degree K (g) life not less than 50000 hours of operation
S&F LED Bollard light 9/10 watt, inverted pyramid tripod type luminaire with soft 360 degree light distribution, with IP 65 grade protection, operating voltage 120-280V, with integrated constant current electronic driver incl all fittings and fixtures complete with PCC work incl taking down existing luminaire complete all as specified and directed. (Make : Crompton, Model : LIARA, Helonix or Equivalent modal in other Makes specified in the tender)
S&F LED post top luminaire, 40 watt, with die cast aluminium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed. (Make : BAJAJ, Cat No: BGCT W4 LED WW / HALONIX, Cat No: HLPT-04-40-CW / SURYA, Cat No: SLE PT 40W-ETPP / Eveready, Cat No: LEDPOST045i3-01 / C&S, Cat No: CETUS-M/40W or equivalent model in other makes specified in particular specifications) NOTE: Wire for connection of luminaire shall be measured and paid separately.
S&F LED post top luminaire, 20 watt, 110 Lumen per watt with die cast aluminium spigot, spun aluminium powder coated top cover, with high power LED, IP 65 grade protection, designed with indirect symmetrical light distribution, with integrated constant current electronic driver incl taking down existing luminaire complete all as specified an directed. (Make : CENTUARY LED Light Cat Pt No.APBY025C1259 or equivalent model in other makes specified in particular specifications) NOTE: Wire for connection of luminaire shall be measured and paid separately.
M&L for replacement of GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 Metre long fixed with 02 sets of flat iron clamp of size 25mm x 5 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
M&L for replacement of Galvanised Steel Tubing Pipe 40mm bore (dia), light grade, length 0.60 mtr having 50 Cm with long Bends, Each for Incoming and Outgoing Cables, grouting in Cement Concrete, complete all as specified and as directed. NOTE : Cement Concrete will be measured and paid for separately under appropriate Item.
Dismantling of broken/dislodged pre-stressed concrete poles / steel tubular poles, of any description including earthwork for removal of concrete foundation, keeping serviceable poles in safe custody for re-use and removal of unserviceable poles from site, complete all as specified and directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminous paint on embedded surface incl writing of Pole Numbers etc., and marking of two black & two yellow strips with synthetic enamel paint upto 1.2 Mtr heightand making good disturbed surface complete all as specified and directed.
Erecting of serviceable pre-stressed concrete poles/steel tubular poles (Serviceable steel tubular pole/pre-stressed concrete poles obtained from Item No. 21.00 here-in-before), of any description, with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt etc, including demolition of existing PCC foundation and making good disturbed surfaces complete all as specified and directed. (NOTE: PCC foundation for installation of pole shall be measured separately)
S&F Astronomical time switch with USB key 2 module 240 Volt AC, DIN mounting type suitable for street light operation, as in repairs, complete all as specified and directed. (MAKE: HAGAR Cat No.EE181 or equivalent model in LEGRAND / SCHNEIDER / INDO ASIAN)
S&F Contractor 40 Amps, 3mdule 2 NO+2NC, type1, DIN mounting type suitable for street light operation, as in repairs, complete all as specified and directed. (MAKE: Hager, Cat No: ECS442 or equivalent model in LEGRAND / HAGER / SCHNEIDER / INDO ASIAN)
S&F MCB TPN 63 Amps, 415 Volts, 10 kA, 'C' curve, as in repairs, complete all as specified and directed. (MAKE: L&T, Cat No: BB40630C or equivalent model in LEGRAND / HAGER / SCHNEIDER / INDO ASIAN)
S&F LED flexi strip light 5 watt , 50 m length, IP 65, 5watt/metre, any colour including suitable driver and connecting up with three core flexible copper conductor cable of suitable size, as in repairs, complete all as specified and directed. (MAKE : MAGIK, Model: Stream LED Strip Light or equivalent model in other makes specified in tender)
M&L for preparation of old painted surfaces of steel tubular poles above PCC coping including cross arms, brackets, pole box and applying one coat of aluminium paint including cleaning of wild vegetation growth/ trimming of tree branches in the vicinity, writing of poles number with sentensile measure white Paint in Black base on steel tubular pole and two black and two yellow strip upto 1.20 metre height with synthetic enamel paint complete all as specified and directed.
Demolition of broken/damaged PCC coping of steel tubular/PCC pole and removal of debris from site complete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundations of poles, as mass concrete, complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 20 mm graded crushed stone aggregate as in plinth cources, string cources, etc., complete including slightly rounded or chamfered for GI tubing post for ait termination rod etc., including using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Dismantling carefully serviceable isolating LT Panel board of sizes 500mm x 500mm x 500mm to 1800mm x 2000mm x 600mm, duly unscrewing/ opening front and back cover and cleaning complete bus bar chamber, tightening all the nuts, bolts incoming and outgoing terminals including cleaning the all switchgear/ accessories and replacement of cable gland and replacement of stainless steel hinges of size 100mm for panel board door fixed with welding machine incl applying one coat of synthetic enamel paint externally to panel board ater scrubbing/ cleaning the surface complete testing the Panel board till satisfaction of Engr-in-Charge, complete all as specified and directed. Note: - (i) Cost of necessary nuts, bolts, washers, screws and colour tape for bus bar, recharging and testing complete shall be deemed to be included in the unit quoted rate. (ii) Quantity of stainless steel hinges as per site requirement shall be deemed to be included in the quoted rate.
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
UNIVERSAL TRADING CENTRE
M/S RAJ CONSTRUCTION AND COMPANY
Charan sales and Service
MS HORIZEN
BASU AND CO
M/S S. K. SARKAR
DEB AND COMPANY
UNITED ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .