| 1 | L1₹37.5 LAccepted-AOC 251A 56 N S C BOSE ROAD KOLKATA 700 047 | KOLKATA | KOLKATA | WEST BENGAL | 700047 | L1 | Accepted-AOC Being a lowest Bidder | |
| 2 | L2₹40.5 L+₹1.1 L (2.78%)Rejected-Finance VILL PUILLYA PO UNSANI DISTT HOWRAH PIN 711302 | HOWRAH | WEST BENGAL | 711302 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.7 L+₹2.3 L (5.84%)Rejected-Finance BHANGARMATH THAKURANI CHAWK PO SAMABYPALLY BALLY HOWRAH 711 205 WEST BENGAL | HOWRAH | WEST BENGAL | 711205 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹41.9 L+₹2.5 L (6.37%)Rejected-Finance TIORKHALI MAHESHGANJ NADIA | NADIA | NADIA | WEST BENGAL | 790804 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹42.2 L+₹2.8 L (7.18%)Rejected-Finance 0 KALIKAPUR KALIKA PUR CHAMPAHATI SOUTH 24 PARGANAS WEST BENGAL 743330 | 24 PARAGANAS SOUTH | WEST BENGAL | 743330 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
7 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/REPLACEMENT OF STRUCTURAL MEMBERS AND RE-STRENGTHENING OF RCC SURFACE TO CERTAIN OLD VINTAGE BLDGS INSIDE FORT WILLIAM UNDER GE(FW) KOLKATA
2022_MES_500848_2
8814/E8
Open Tender
Civil Works
Item Rate
240 days
GE(FW) Kolkata
ref tender documents
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹70,000
9 Mar 2022
25 Jan 2022
8 Feb 2022
25 Jan 2022
7 Feb 2022
25 Jan 2022
60 days
Amount
Taking down cement plaster or cement lime plaster on brick or stone walls etc including rakingout joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Dismantling timber scantling 40 sq cm and over in section in any position (unframed) and removing off the site complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., from any position or height complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
Dismantling of ceiling board incl snap grid frame of any thickness including cover fillets complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
Taking up or down steel water tubing 15 mm bore incl connection , cleaning etc
-ditto all as per item No 11 here-in-before but 20 mm bore
-ditto all as per item No 11 here-in-before but 25 mm bore
M&L brick work with fly-ash bricks, straight or curved on plan exc 6m radius buit in cement mortar 1:6 complete all as a specified and as directed.
-ditto- but using serviceable brick obtained from demolition.
M&L for brick work with fly ash brick straight or cuved on plan to any radius in half bricks thick walls, built in 1:4 cement mortar complete all as directed.
M&L Rendering 15mm thick, on fair faces of brick or concrete surfaces of walls in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick built in cement mortar (1:4) in two layers (10mm + 5 mm) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) and 2nd layer mixed with water proofing compound as per mnufacturer's instruction for bldg height upto 4 storey complete all as specified and directed. (NOTE : Water proofing compound shall be measured and paid seperately).
M&L 10mm thick rendering on ceiling surfaces (upto ceiling height of 7m) in cement mortar 1:3, finishing even and smooth without using extra cement including necessary scaffolding complete all as a specified and as directed
Supply only liquid water proofing compound all as specified and as directed.
M&L for cement concrete (1:2:4) type B1, using 20 mm graded stone aggregate, as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and necessary formwork complete all as specified and directed.
M&L RCC 1:1½:3, type A1 (using 20mm grade stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for RCC 1:1½:3 type A1 (using 20 mm graded aggregate)as in slabs supported on walls, beams and columns in floors, roofs, drain, ducts, canopies etc. complete complete all as specified and as directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L RCC 1:1½:3 (Type A1) using 20 mm graded stone aggregate as in chajjas etc complete all as specified and as directed. (NOTE: MS reinforcement shall be measured and paid seperately)
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for fair finished surfaces complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for fair finished surfaces complete all as specified and directed..
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves etc for fair finished surfaces complete all as specified and directed.
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L TMT Bars 6-8 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L for TMT bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length , bent to shape required as in reinforcement and binding with MS wire (annealed ) not less than 0.90 mm dia complete all as specified and directed .
S & F in repair Cast iron work grade FG -150 unmachined in brackets, gratings, railing, frames, manhole covers and similar articles exc 5 Kg each complete all as specified and as directed.
M & L for cutting Grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type-B1 as required complete all as specified and directed.
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 50 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.
-ditto- but for 25 mm average thickness
M&L for applying chloride free rust removing chemical on rusting steel reinforcement bar as per manufacturer's specification and removing all rust from steel reinforcement bar by wire brush & sand/emery paper (after 24 hours of application of rust remover) and cleaning the area thoroughly by water with the help of pressure jet and allowing it to dry and making the reinforcement bar totally rust free (for any storey/ height of building/ structure) complete all as specified and as directed. (Make of Rust removing chemical :- Reebaklens RR of FOSROC or equivalent product other makes specified in tender) (NOTE: Surface area of cleaned steel reinforcement shall be measured for payment)
M&L for introducing new mild steel TMT reinforcement bars upto 12 mm dia for structural connection in RCC beams, columns, lintel and slabs (for any storey/ height of building/ structure) including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and up to 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges, plastic nozzles etc as per manufacturer's instructions etc all as specified and directed. (Make of epoxy chemical :- Lockfix E75 of FOSROC / Hilti HY 150 or equivalent product other makes specified in tender) (NOTE: Quoted rate is deemed to be inclusive of the cost of reinforcement bars)
M&L for preparation of old existing corroded and new introduced reinforcement surface (at any storey/ height of building/ structure) by brush and application of two component epoxy based zinc rich primer, of minimum specific gravity 1.75, adhesive bond strength with steel as 1.50N/mm2, as a protective coating to steel reinforcement bars in concrete with total zinc content in dry film >90% by volume and DFT per coat >50 microns complete all as specified and directed. (Make- Nitozinc primer of FOSROC or equivalent product in other makes specified in tender) (NOTE: Surface area of steel reinforcement shall be measured for payment)
M&L for applying a coat of epoxy bonding agent on existing concrete surfaces, with mixed density 1.48 Kg/litreand adhjesive bond strength>2.50 MPs, mixed and applied as per manufacturer's specifications complete all as specified and directed. (Make- Nitobond EP of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
M&L for applying shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar, as per manufacturers instructions to get a compressive strength of 35 MPA after 28 days, finishing surfaces even and smooth complete all as specified and directed. (Make- Rendroc SP 40 of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
Material , labour and placing in position free flow shrinkage cementitious micro concrete of compressive strength, flexural strength shall not be less than 50 MPa at 28 days, 5MPa at 28 days respectively for strengthening of beams, columns & other structural elements of average thickness 50mm and including surface preparation & suitable type formwork etc. as per manufacturers instruction complete all as specified and as directed.. (Make of micro concrete:- Renderoc RG of FOSROC or equivalent product in other makes specified in tender) (NOTE: Measurement shall be considered for the surface area of RCC member.
GENERAL NOTES FOR ITEM NO. 33 TO 40 :- (i) The work shall be got executed through authorised applicator of the chemical manufacturers. Necessary documents to this effect shall be obtained from manufacturer and submitted to the Engineer-in-Charge. (ii) Contractor shall provide additional manpower, resources, preparatory work etc. required for execution of the work as required by the authorised applicator. Quoted rates are deemed to be inclusive of the above aspects. No extra claim shall be admissible during execution of work on this account.
S&F in repair Wire netting of galvanised steel wire 1.40 mm dia fixed with tinned tacks of wire staples, size of mesh 20 mm complete all as specified and directed.
M&L for second class hardwood timber in scantling clean sawn and in any position complete all as specified and directed.
Re-fixing of serviceable timber scantling, obtained from dismantling complete all as specified and directed.
M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of creosote oil, complete all as specified and directed
M&L False ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long and applying two coats of oil bound distemper over a coat of primer on exposed surfaces complete all as specified and as directed. (NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board)
Re-fixing of aluminium snap grid sytem with ceiling board using serviceable grid sections and ceiling board obtained from taking down of false ceiling including hanging arrangements with 1.6mm dia GI wire and anodised adjuster and applying two coats of oil bound distemper over a coat of primer on exposed surfaces complete all as specified and as directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
-ditto- but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
S&F 0.56 mm thick plain aluminium sheeting alloy 31000 H4 as in ridges, hips, valley gutter, drip and straight flashing etc complete all as specified and directed.
S&F in repair fibre glass reinforcement translucent corrugated sheeting of 2mm thick with two corrugation side lap fixed with fixed with L type or J type or cranked hook bolts in roofs, walls etc complete all as specified and directed.
M&L cutting holes in brick walls exc. one brick but n exc. two brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required .
M&L in repair for Expanded metal, cut to length, bent to shape required and tying with and including anealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight n exc 4 Kg per sqm complete .
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exc 15 cm but n exc 22.5 cm long, diameter 11 to 15 mm complete all as specified and directed.
M&L for structural steel work Fe 410-W (Gde E-250) quality B, rolled mild steel 'Ι' section beam, channels, angle etc at bottom or soffit of floor/roof slabs at a height of upto 6 metre including using iron props and steel plates to existing structure, overhead members such as beams, slabs etc so as to ensure safety of existing structure and floor during repairing works complete all as specified and directed.
All as per Item No. 54 here-in-before but for ceiling height beyond 6 m and upto 12 m
All as per Item No. 54 here-in-before but using old serviceable iron members for ceiling height upto 6m height
All as per Item No. 56 here-in-before but using old serviceable iron members for ceiling height beyond 6 m and upto 12 m
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for taking down plants/vegetaion from wall upto roof level by means of cutting holes into brick wall and making good the surfaces of dismantling portion n.exc 150Sqcm superficial area and n.exc on brick deep by PCC 1:3:6 type C1 (using 20 mm graded stone aggregates) and plastering in cement mortar (1:4) of disturb portion and applying two coats of cement based paint over a coat of primer to match the existing surfaces height upto 4th floor incl necessary scaffolding etc complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L applying two coats of exterior acrylic emulsion weather proof paint over a coat of alkali resistant primer to new wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer's instructions, upto 4 storey height complete all as specified and as directed.
M&L Preparing new Surfaces of wall and applying Three coats of white wash complete all as specified and as directed.
M&L Preparing new Surfaces of ceilings and applying Three coats of white wash complete all as specified and as directed.
M&L applying one coat of exterior acrylic emulsion weather proof paint to old decorated wall surfaces of any description, over 10cm width or girth not otherwise described, as per manufacturer's instructions, upto 4 storey height complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces and applying one coat of cement base paint complete all as specified and directed.
M&L Preparing old decorated surfaces of wall and applying one coat of white wash complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L Preparing old Steel Surfaces of any description not otherwise decribed over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint, complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in floor, plinth protection etc, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for forming construction/dummy joints 65 mm deep x 10 mm wide filled with sealing compound Grade 'A'
S & F cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 150 mm bore, fixed with cement joints complete all as specified and directed.
S & F 150 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
S & F 150 mm bore CI double branch (Tee section) for CI rain water pipes complete all as specified and directed.
S & F cast iron rain water socket pipes, without ears, conforming to IS:1230-1979, 100 mm bore, fixed with cement joints complete all as specified and directed.
S & F 100 mm bore CI bends or elbow square for CI rain water pipes complete all as specified and directed.
S & F 100 mm bore CI double branch (Tee section) for CI rain water pipes complete all as specified and directed.
M&L bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required and similar small articles conforming to Fe-290 Gde-E-165 including painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) pipes, type 'B', single socketed in any length with rubber ring joints fixed to walls with clamps for bldg height upto 4 storey complete all as specified and directed.
S&F in repair PVC (SWR) pipes of type-A for use in ventilation pipe work and rain water application, single socket, 110 mm bore in any length including rubber ring joints and fixed to wall with clips, other standard material as specified in IS 13592, for bldg height upto 4 storey complete all as specififed and directed.
S&F in repair PVC (SWR) bends for 110 dia pipe for any building height complete all as specified and directed.
S&F in repair PVC (SWR) Junction single T for 110 dia pipe for any building height complete all as specified and directed.
M&L for brushing cement slurry @ 2.75 Kg/sqm over cleaned roof surface prior to application of concrete complete all as directed by Engineer - in - charge .
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, finished even and fair complete all as directed by Engineer - in - charge .
M&L for cutting grooves in brick wall, 75 mm wide and 65 mm deep and shaping horizontal face of groove with cement mortar 1:3 or cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregates) as required complete all as specified and directed.
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 1000 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
Disconnecting exiting water storage Tank of capacity exceeding 500 litres but not exceeding 1000 liters for cleaning of water tank, removing of mud, sludge etc and flushing with chlorine water including supply and fixing of any damaged accessories for water Tank and writting MES No, Unit Name (With capital letter, not exceeding 15cm height and not exceeding 10ms each tank ) and re-connecting and refixing all connections complete all as specified and directed.
S&F tubes 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors.
-ditto all as per item No 90 here-in-before but 20 mm bore
-ditto all as per item No 90 here-in-before but 25 mm bore
S&F in repair stop valve cast copper alloy, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or union for pipe 20mm bore, ISI marked complete all as specified and directed.
-ditto all as per item No 93 here-in-before but 25 mm bore stop valve
PRABIR TRADERS
dutta and dutta
SHEIKH ENTERPRISE
GHOSH ENTERPRISE
MS HORIZEN
JOY-EN-JOY
JOY RAM ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .