Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹15.3 L+₹77,500.89 (5.35%)Rejected-Finance RONALDSAY ROAD JOYMAGAR BUS STAND AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L2 | Rejected-Finance Quoted amount higher than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not fulfilled the NIT criteria |
Tender Value
₹13.8 L
EMD Value
₹27,600
Closing Date
7 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL N K CHAUDHARY
HQ 137 WKS ENGR PIN 914137 CO 99 APO
REPAIR REPLACEMENT ANT MAINT OF 11 0.433 KV TRANSFORMER GOD HT DISTRIBUTION LINES AND ALLIED WORKS AT MIL STN AGARTALA
2022_MES_530605_3
8671/E8
Open Tender
Civil Works
Item Rate
270 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
AGE (I) AGARTALA
₹27,600
Yes
22 Feb 2023
15 Nov 2022
14 Dec 2022
15 Nov 2022
7 Dec 2022
23 Nov 2022
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth for foundation of poles, cables etc and getting out in soft / loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and exceeding 1.5 metre depth but not exceeding 3.00 metre depth for foundation of poles, cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing excavated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Material and labour for well burnt subclass 'B' bricks laid flat width wise along the length of cable for cable protection complete all as specified and directed.
Material and labour for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
Material and labour for PCC (1:2:4), type B1, (using 20mm graded stone aggregate), as in cills, coping, benching on chajja, roof kerbs, bed blocks and the like including weathering, slightly rounded or chamferred angles and throating with and including necessary formwork complete all as specified and as directed.
Taking down existing electric steel pole 11 / 9 meter size including demolition of existing concrete for pole foundation and removing rubbish off the premises complete all as specified and as directed.
Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, including painting of red & white alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles complete all as specified and as directed. (Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)
Material and labour for preparation of old painted surface of 11 Mtr long steel tubular electric pole by using emery paper and applying one coat of silver aluminium paint from bottom to 1.20 m height alternative with 30cm red and white strip on exposed surface and writing pole No. with black paint on yellow background complete all as specified and directed.
Material and labour for preparation of old painted steel surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking up / down unserviceable underground cable , HT / LT, from trenches, ducts, floor, pipes and removing materials from site of work complete all as specified and as directed. (Note: Excavation and earthwork shall be measured and paid separately under relevant item of schedule.)
Supply, laying connecting and testing XLPE insulated (Earthed) cable in trenches / or fixed on pole etc in screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with stranded alluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm, 3 core, Confirming to IS-7098 (Part-II) 1985 complete all as specified and as directed. Note : Earth work will be measured and paid separately under respective item.
Supply and fixing in repair heat shrinkable type end termination cable jointing kit indoor type suitable for XLPE insulated cable 120 Sqmm to 185 Sqmm size, 3 core, 11 KV including testing on completion complete all as specified and as directed.
Supply and fixing in repair heat shrinkable type end termination cable jointing kit outdoor type suitable for XLPE insulated cable 50 Sqmm to 95 Sqmm size, 3 core, 11 KV including testing on completion complete all as specified and as directed.
Supply and fixing in repair heat shrinkable type cable jointing kit for 11 KV (Earthed) grade cable for straight through type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured cable aluminium conductor of size 50 Sqmm to 95 Sqmm size including testing on completion complete all as specified and as directed.
Supply and fixing in repair heat shrinkable type end termination cable jointing kit indoor type suitable for XLPE insulated cable 50 Sqmm to 95 Sqmm size, 3 core, 11 KV including testing on completion complete all as specified and as directed.
Supply and fixing in repair aluminium lugs of size 95 Sqmm complete all as specified and directed.
Dismantling of existing unserviceable / undersized ACSR / AAC conductor of any size, jumper from overhead line complete all as specified and directed.
Supply and fixing ACSR conductor, weasel type as in overhead electric line, streaching the same between two poles for requirred span with standard gauge and size of ACSR and binding the conductor with pin / shakle insulator and jumper with alluminium binding weir not less than 2.00 mm dia size complete all as specified and directed.
Material and labour for restringing, tightning of loose / broken ACSR conductor (any size) 11000 Volts grade any type / size, maintaining standard sag including binding the conductor with pin / shakle insulator and jumpers with aluminium binding wires not less than 2.00 mm dia, PG clamp etc on HT overhead lines consisting of 3 conductors, jumpers etc drawing as OH line complete all as specified and directed. (Note: Each line to be measured for payment purpose)
Cutting and trimming of only tree branches and creepers and ensure 1.50 metre clearence which are touching of overhead lines / poles between the tree and overhead lines and poles on all direction and disposal of waste timber and tree branches at a distance n.exc 50 mtrs without damaging of ACSR conductor complete all as specified and direted.
Dismantling lightning arrestor 11/33 KV complete all as specified and directed.
Dismantling of old unserviceable damaged stay assembly embedded in concrete including demolition of PCC complete all as specified and directed.
Dismantling of old unserviceable earth wire / stay wire / anti climbing device complete all as specified and directed.
Dismantling of old unserviceable insulator, any type / size complete all as specified and directed.
Supply and fixing cradle guard hexagonal / rectangular fabricated with galvanised steel wire 4 mm dia on road crossing and streching the same with LT / HT overhead lines and binding the conductor with GI binding wire of suitable size complete all as specified and as directed.
Material and labour for anti climbing device, spike type fabricated from structural steel comprising of MS flat 20 mm x 6 mm MS round bar pointed 8 mm dia, 20 cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer including taking down old unserviceable device complete all as specified and directed.
Supply and fixing galvanised stay strand 7/3.15mm including taking down old unserviceable one complete all as specified and directed.
Material and labour for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer including taking down old unserviceable device complete all as specified and as directed.
Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed.
Supply and fixing Disc type insulator, porcelain, vitreous, 145 mm high and 255 mm dia ball and socket type, white, brown or green single disc assembly including nuts, bolts as requirred for 11000 volts grade confirming to IS-731 and IS-3188 including tension clamp complete all as specified and as directed.
Material and labour for Loop type insulator, vitreous porcelain, white, brown or green, large size with overall dimension 90x140mm clearance of hole 25.5mm complete all as specified and as directed.
Supply and fixing stay assembly with using 20 mm diameter of stay rod complete with accessories as shown in electrical plate No. 1 of SSR Part-I, 2009 all as specified and directed. (Note: loop type insulator, stay clamps, excavation and concrete shall be measured and paid separately)
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 400 Amps including taking down existing GOD complete all as specified and as directed.
Supply and fixing drop out fuse single pole mounted on insulator polymer type 11000 volt grade and current rating above 25 Amps and upto 50 Amps including taking down old unserviceable drop out fuse and removing from site complete all as specified and directed
Material and labour for repairing of old defective gang operating device after taking shut down from MRS,renewal of worn out male and female contacts,replacement of HT contact knife,removal of deposited carbon,applying mineral jelly on male/female contacts and knife incl proper setting of gang operating device for smooth operation incl replacement of worn out nut/bolts and washers incl taking down old unsv burnt out parts complete all as specified and directed.
Supply, install, testing and commissioning of lightening arrestor expulsion type complete with all fitings, transmission class, discharge capacity minimum 65 KA suitable for working voltage of 11000 Volts including all necessary fittings all as per IS-3070 Part-III and IEC 1994 complete all as specified and as directed.
Supply and fixing Danger notice plate of 25x20cm size and 1.6mm thick mild steel sheet, vitreous enamelled white, with letters(Local & Hindi language), figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT pole including taking down old unserviceable one complete all as specified and as directed.
Supply and laying GI tubing 80mm bore light grade with fittings laid in trenches or for road crossing for protection of HT/LT underground cables including taking up/down unserviceable pipe complete all as specified and directed.
Supply and laying GI tubing 100mm bore light grade with fittings laid in trenches or for road crossing for protection of HT/LT underground cables including taking up/down unserviceable pipe complete all as specified and directed.
Materials and labour for earthing complete with Galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with GI strip of 25 x 4 mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Materials and labour for earthing complete with Galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with GI strip of 32 x 6 mm size by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking out unserviceable earthing plate and accessories all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Taking down carefully the existing 11KV/433V distribution transformer of capacity 63 KVA to 300KVA by disconnecting HT overhead connection/underground cables and earth strips etc from any substation/locations using suitable capacity of crane or by any other method irrespective of type of approach available,loading in vehicle,transportaion to workshop for repairs and unloading carefully reloading the transformer after repairs and testing of transformer,transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed. (Note : All the T&P required for disconnection,connection,loading and loading including necessary petty items like bolts,nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted.)
Material and Labour for repairs to transformer step down 11KV/0.433KV any type of capacity 63KVA to 300KVA,after dismanantling the transformer body carefully,opening the top cover of transformer for inspection/repair,drain out the transformer oil from the tank complete,taking out the core and winding assy by disconnecting the internal connections,removing the carbon/sludge deposit in transformer housing core,renewal/replacement of u/s rubber bushes and washers,replacement of tap changer winding and thimbles,replacement of silica gel,replacement of top cover gasket set including pasting with pasting material,replacement of worn out out nut and bolts,replacement of unserviceable LT & HT bushes,cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage,insulating the winding connection by using fire proof sleeves and fire proof tape,warnishing the coil,keeping the coils in electric oven chamber for 24 hrs to remove the moisture,Painting of complete transformer body from outside and inside by weather proof type using spray gun,Marking of MES/SM Numberetc,replacement of conservator tank glass,re-installing the core and winding inside properly,making the all connection with suitable copper lugs,refilling of dehydrated transformer oil including dehydration,re-installing the top cover after cleaning and painting of housing,conservator tank,expulsion vent etc,Meggering the LT and HT side of the Transformer and testing complete all as specified and directed. (Note-Re-winding and new spares will be measured & paid seperately under relevent items of this schedule.)
Supply only of brass terminal rod with nuts,bolts,washers & bushingss suitable for HT side of the transformer of any make and capacity from 100 to 250KVA complete all as specified and directed.
Supply only of brass terminal rod with nuts,bolts,washers & bushingss suitable for LT side of the transformer of any make and capacity from 100 to 250KVA complete all as specified and directed.
Supply only of bush type insulator white/brown/green working pressure 11000Volts HT side complete all ads specified and directed.
Supply only of bush type insulator white/brown/green working pressure 433Volts LT side complete all as specified and directed.
Supply only silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100KVA to 250KVA transformer complete all as specified and directed. (Note: for serial item no. 47 to 51: Cost for labour for replacement deemed to be included in rate quoted against item no. 46 above)
Material & labour for new transformer oil of BDV not less than 50KV for topping up of reduced level of 33KV/11KV transformers and CTs complete including removing of old unserviceable transformer oil all as specified and directed.
Material and labour for conducting oil filteration by stream line/Vaccum type filter machine to improve required BDV incl routine testing after filteration for any capacity of transformers all as specoified and directed.
Material and labour for painting the outer surface of the transformer with two coat of synthetic enamelled paint after preparing the surface dust and oil free and cleaning the bushes,name plate etc paint free after painting including writting the MES/SM No with white enamelled paint all as directed for capacity of transformer 100KVA to 600KVA (Indoor/outdoor type) complete all as specified and directed.
Material and labour for painting the outer surface of the transformer with two coat of synthetic enamelled paint after preparing the surface dust and oil free and cleaning the bushes,name plate etc paint free after painting including writting the MES/SM No with white enamelled paint for capacity of transformer 1.6MVA (outdoor type) complete all as specified and directed.
Material and labour for rewinding of high voltage coil with super enameled impregnated paper insulated copper winding wire of existing gauge, varnishing and drying the complete coils complete all as specified and directed.
Material and labour for replacement of unsv HT jumper from 2 pole/4pole structure/ overhead line to Air break switch and AB switch to drop out fuse, with suitable ACSR conductor incl HT PVC sleeve in colour code (Red,Yellow,Blue),including taking down old one complete all as specified and directed.
Removal of unwanted grass, plants and vegetations from E/M installations on Monthly basis for entire contract period including surface dressing and removal of grass ,plants and vegetations from site not less than 50mtr from starting point complete all as specified and directed (Note- (i) Removal of unwanted grass and vegetation will be repeated once a month (ii) Measurement shall be taken monthwise.)
M/S NIYATI NETWORK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .