Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | Admitted-Finance |
| 4 | Admitted-Finance 19 LAKE TEMPLE ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | Admitted-Finance |
| 5 | Rejected-Technical 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | Rejected-Technical Not-Qualified as per NIT |
Tender Value
₹45.1 L
EMD Value
₹90,131
Closing Date
29 Jul 2024, 6:00 pmClosed
DIRECTOR, CSIR-CIMAP
Kukrail Picnic Spot Road, P.O. CIMAP,Lucknow-226015
Replacement and DSITC of Water cooled Air-Conditioning System of Golden Jubilee Auditorium at CSIR-CIMAP, Lucknow
2024_CSIR_201516_1
68_082/873/2024-MP(Works)
Open Tender
Electrical Works
Item Rate
150 days
CSIR-CIMAP
xi. Valid Authorization certificate from the OEMs / OEM (Authorized Agencies / Dealers / Distributers / Assemblers) of Centralized Air Conditioning Plant
2 documents required · 2 mandatory
₹1,180
DIRECTOR, CSIR-CIMAP
₹90,131
27 Aug 2024
16 Jul 2024
31 Jul 2024
16 Jul 2024
29 Jul 2024
16 Jul 2024
16 Jul 2024 - 29 Jul 2024
Design, Supply, Installation, Testing and Commissioning (DSITC) of 11.0 Ton water cooled Package Air Conditioner unit complete with blower section, centrifugal blower, coil section, DX cooling coil in AL. fins & copper tube construction drain pan, energy efficient Scroll compressors - 02 nos. with starters, microprocessor controllers working with eco-friendly refrigerant gas. Installation Place - Existing Machine Room adjacent to Auditorium including minor civil work (If any) as required for proper erection. Nothing will be paid extra on any account i.e. lifting, shifting, tools, tackles, any special arrangements etc. to meet site work requirement and to complete work in all aspects.
DSITC of 3.0 HP- 5.0 HP, (opted based on design and site requirement) Three Phase, RPM - 2900 (Up to) mono-block centrifugal pump with mechanical seal to circulate condenser water from package units to cooling tower, Installation Place - Existing roof above Auditorium including minor civil work (If any) as required for proper erection. Nothing will be paid extra on any account i.e. loading, unloading, lifting, shifting, tools, tackles, any special arrangements etc. to meet site work requirement and to complete work in all aspects.
DSITC of 50.0 Ton induct Draft non sprinkler type square/ Rectangular FRP cooling tower complete with FRP basin along with complete accessories, honeycomb type PVC fills weather proof cooling tower motor with Cooling tower motor (Spare) - One no. Installation Place - Existing roof above Auditorium including minor civil work (If any) as required for proper erection. Nothing will be paid extra on any account i.e. loading, unloading, lifting, shifting, tools, tackles, any special arrangements etc. to meet site work requirement and to complete work in all aspects.
DSITC of MS ‘C’ class piping including elbow, tee, reducer flanges gasket, nut bolts, etc of following sizes to meet site requirement and complete in all aspects including appropriate paintings as applicable
100 mm dia
80 mm dia
65 mm dia
50 mm dia
Supply and Installation of uPVC Drain Pipe duly insulated with Nitrile rubber insulation of size 32/40 mm dia with fittings to meet site requirement and complete in all aspects.
DSITC of hand lever operated BUTTERFLY VALVE with Cast Iron body Stainless Steel Disc, Nitrile Rubber Seal & O-Ring PN 10 pressure rating including flanges gasket, nut bolt etc of following size to meet site requirement and complete in all aspects:
100 mm dia
80 mm dia
65 mm dia
50 mm dia
SITC of ‘Y’ Strainer including flanges gasket, nut bolt etc of following size to meet site requirement and complete in all aspects
80 mm dia
SITC of dual plate type NRV including flanges gasket, nut bolt etc of following size to meet site requirement and complete in all aspects:
65 mm dia
Providing and fixing in position 100mm dia dial type water pressure gauge with valve & siphon cock to meet site requirement and complete in all aspects.
Providing and fixing in position 100mm dia dial type Thermometer with fitting to meet site requirement and complete in all aspects.
Providing & Fixing of water flow switch to meet site requirement and complete in all aspects.
Providing & Fixing of 15 mm dia Ball valve/Gate valve to meet site requirement and complete in all aspects.
Providing & Fixing of 15 dia Auto air vent to meet site requirement and complete in all aspects.
DSITC of 3.0 kW finned type electric strip air heaters complete with thermostat, Geyserstat complete with fixing frame etc. for winter heating to meet site requirement and complete in all aspects.
`Design, fabrication, supply, erection, testing and commissioning of suitable electrical panel, indoor type, CRCA sheet steel of 1.6 mm thickness for body & 2mm for load bearing points duly powder coated, digital metering (Multi-Function Meter), indicating lamps, Incomer: 300A MCCB - One, Outgoing: 63 A MCCB - Three for package units supply, complete suitable rating of DOL starters for cooling Tower motor, condenser pumps and 9 KW x 2 nos. heater bank starter with toggle switch/Push button & safeties in outgoing to meet site requirement and complete in all aspects
Supply & Laying (In surface inside conduit) ) of aluminum armored conductor XLPE cable cable of 1.1 KV grade power cable of following size to meet site requirement and complete in all aspects:
4.0 Core X 16 Sq mm
4.0 Core X 10 Sq mm
4 .0 Core X 4 Sq mm
Supply & Laying (In surface inside conduit) of 2C x 1.5 Sqmm Flexible control cable
Supply & Laying of suitable size copper flexible fire proof cable with insulator for heater connection to meet site requirement and complete in all aspects.
Earthing with G. I. earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe 2.7 meter long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in races for connection etc as required
Providing and fixing of 6 SWG dia G.I. wire on surface or in races for loop earthing as required
DSITC of suitable GI perforated cable tray for laying of cables to meet site requirement and complete in all aspects.
DSITC of site fabricated GSS rectangular ducting (Class VIII Galvanized) with all component like GI sheet, Duct support MS angles, nut bolts etc to meet site requirement and complete in all aspects.
22 Gauge
24 Gauge
SITC of Duct acoustic lining with 25 mm thick fiberglass covered with RP tissue paper & perforated Aluminium sheet to meet site requirement and complete in all aspects.
SITC of thermal duct insulation with XLP/Nitrile 13 mm thickness to meet site requirement and complete in all aspects.
SITC of Star bond insulation on exposed duct for UV Protection to meet site requirement and complete in all aspects
SITC of Extruded Aluminium Powder coated supply/ return air spot grilles to meet site requirement and complete in all aspects.
SITC of MS volume control Damper to meet site requirement and complete in all aspects.
SITC of duct damper to meet site requirement and complete in all aspects.
SITC of canvass connection to meet site requirement and complete in all aspects
SITC of Fire Damper (Spring Load) in suitable position to meet site requirement and complete in all aspects.
SITC of 140 A, 415VAC, Three Phase, Automatic Phase Sequence Corrector including electrical connections in input and output to meet site requirement and complete in all aspects.
SITC of 250A, 415VAC, Three Phase, TPMCCB with metallic enclosure including electrical connections in input and output to meet site requirement and complete in all aspects.
Cat (B) - Buy Back Items
Buy back and dismantling of old existing air conditioners water cooled Voltas make plant 3X7.5 TR rating installed in institute premises. The existing air conditioners water cooled Voltas make plant is in operational/functional condition. The firm has to dismantle, transport, and take back the existing Air conditioners from the installation place. A detailed item list is prepared and submitted by the firm to issue gate pass to take the materials outside the institute. Format will be given by concerned Engineer In- charge towards issue of gate pass. Make good if any things occur during dismantling. Installation Place - Existing Auditorium including minor civil work (If any) as required for proper repairing and making good. Nothing will be paid extra on any account i.e. loading, unloading, lifting, shifting, transportation, special tools, tackles, any special skill and specific arrangements (Scaffolding / ladder) etc. to meet site work requirement and to complete work in all aspects. The dismantling work may be carried out with all safety measures (personal and equipment’s) by engaging all the skilled man power and special tools as required for proper and safe dismantle including minor civil work (If any) as required for proper erection. The firm may physically inspect and check the existing old water cooled AC plant before quoting the price. Buy Back is mandatory.
M/S UNITY ENGINEERS
Mark Engineering Inc.
KRISHNA REFRIGERATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .