Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹46.4 L+₹3.5 L (8.03%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹49.2 L+₹6.2 L (14.4%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹51.2 L+₹8.2 L (19.1%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹52.5 L+₹9.5 L (22.0%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
15 Sept 2022, 6:00 pmClosed
MAJOR VIPIN BHATT
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND MAINTENANCE OF LT DISTRIBUTION SYSTEM WITH ALLIED WORKS, COMPRESSIVE MAINTENANCE OF DG SETS AND ALLIED SERVICES IN DOMESTIC AND TECHNICAL AREA AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2022_MES_547741_1
8796/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Kalaikunda
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹80,000
Yes
10 Oct 2022
26 Aug 2022
16 Sept 2022
26 Aug 2022
15 Sept 2022
10 Sept 2022
Amount
Comprehensive maintenance for a period of six months of DG sets of capacity 20 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine and including replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (Make: Cummins/ Kriloskar/ Ashok Leyland)
All as per above item No.01 here in before but 30 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 40 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 50 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 63 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 82.5 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 100 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 125 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 160 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 200 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 250 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 320 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 400 KVA DG set complete all as specified and as directed.
NOTES:- (Applicable for BOQ Serial Item No. 1 & 13 here in before) (i) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of DG Sets (ii) Preventive and Corrective Maintenance : The authorised Service Engineer of OEM or OEM Certified agencies shall visit the site once in a month for carrying out preventive and corrective maintenance on all the units installed at site. This includes maintenance of all mechanical, electrical and electronic parts / sub-assemblies. The preventive maintenance report will be as per the Original Equipment Manufacturer's instructions and as specified in Particular Specification. The Contractor may claim payment on monthly basis. In that case the payment shall be made with pro-rata basis on quoted rates. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) Kalaikunda officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE, Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during comprehensive maintenence period.
(iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately under Prime Cost Sum (vii) The Contractor shall maintain service reports for all visits & breakdown visits & copy of the same will be submitted every month to the Engineer in Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil ,complete all as specified and directed Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/-per hour will be charged to contractor. In this GE decision will be final conclusive and binding.
Returning filling in soft/loose soil, including, spreading levelling watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
M & L sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directed by Eng in Charge. Note:-Punned thickness to be measured for payment.
M & L for Fly ash bricks laid in trenches as in protection of UG cables all as specified and as directed.
M & L for laying old size sub class ‘B’ brick for PVC/ XLPE under ground cable protection in trench, layed in the manner that width of brick to be peperndicular to the axis of cable , over LT under ground cable (retreived from taking out of old unsv cable) all as specified and directed.
Repairs / Maint of LT Panel board/ feeder pillar box of various sizes including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,replacing burnt DMC insulator or bus bar supports as per exsiting one, removing old burn out wiring and re-wiring with new cable of exsiting size, including replacement of un-serviceable parts and hard ware, replacement of all rusted nut bolts with new steel nut bolts and washer, wrapping of existing incoming and out going cables whose PVC insulation gets detoriated, cable to be wraped with insulation tape (minimum three layers over one another on detoriated portion) with colour code (Red, yellow blue for phase and black for neutral) complete all as specified & directed. Note :- (i) Cost of unsheathed multistranded copper conductor for internal wiring like connection of CTs and DMC insulators are deemed to be included in quoted rate. (ii) Suitable size of cable lugs to be provided by contractor for fixing /jointing the cable in bus bar etc. (iii) Cable gland if required shall be provided and included in cost of repair. (iv) Existing cable to be removed from MCCB/MCB and to be refixed after providing suitable size lugs. Cost of lugs included in cost of repair.
Supply and fixing in repair 3 phase digital voltmeter flush mounting 96 X 96 mm of input voltage measurement range 50-520 VAC(P-P) , 5A,accuracy class 0.5 for LT panel board, with proper caliberation complete all as specified and directed by Engr-in-Charge including taking down unserviceable Make : L&T Cat part no. WL1332020OOOO or equivalent in conserv/siemens
Supply and fixing in repair Indoor type insulated ring type low tension current transformers of ratio 200/5A accuracy class 1.0 for LT panel board, complete all as specified and directed by Engr-in-Charge including taking down unserviceable .
Supply and Fix in repairs,LED Indicator 16 mm with power consumption < 0.6W, LVGP & surge protection, 64/110 Volts AC/DC / 240 Volts AC, colour Red/Green/ Yellow/Amber/Blue/White, complete all as specified and directed. [Cat No. SIL of Make “L&T” or equivalent Model of Make HPL/ AE]
Supply and fixing FRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size 25 Sqmm single core including copper lugs complete all as specified and as directed.
Supply and fixing FRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size 50 Sqmm single core including providing copper lugs complete all as specified and as directed.
Supply and fixing FRLS PVC insulated single core unsheathed multistrand copper conductor for voltage grade 1100 V of size 95 Sqmm single core including providing copper lugs complete all as specified and as directed.
Preparation of the old decorated existing external and internal steel surface of feeder pillar boxes/LT panels of any description, any size and in any position by thoroughly cleaning of dirt, fluxing material, other foreign matter and sand papering the surface to remove all scale and rust,wiped finally with mineral turpentine to remove oil, grease and including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of synthetic enameled paint over a coat of red oxide primer by using spray machine on old prepared surface and writing MES serial No with approved colour code complete all as specified and dircted by engr in charg Note (i) Painting to be done after carrying out all the welding work for replacement of hinges, door lock etc. (ii) Painting shall be done by spray gun. (Approximate minimum area : 40 sqm)
Preparation of the old decorated existing external and internal steel surface of feeder pillar boxes/LT panels of any description, any size and in any position by thoroughly cleaning of dirt, fluxing material, other foreign matter and sand papering the surface to remove all scale and rust,wiped finally with mineral turpentine to remove oil, grease and including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopponf required and applying two coats of synthetic enameled paint over a coat of red oxide primer by using spray machine on old prepared surface and writing MES serial No with approved colour code complete all as specified and as directed. complete all as specified and dircted by engr in charg Note (i) Painting to be done after carrying out all the welding work for replacement of hinges, door lock etc. (ii) Painting shall be done by spray gun. (Approximate minimum area : 30 sqm)
M&L for taking shut down including repairing of LT Panels (Indoor type) by providing connectors, copper lugs, nuts, bolts, etc of suitable sizes for incoming and outgoing UG cables including proper LT insulation tapes to cables which are deteriorated and cleaning the internal area of panel, cleaning the rusted parts by WD-40 and replacing the damaged spare parts like nuts, bolts , screws etc with new steel nut bolts washers including repairing of panel doors by welding broken hinges and repairing the door locks all as specified and directed by Engr-in-charge. Note : (i) LT panel in which repairing of internal wiring, not required and not covered under respective item here-in-before shall be measured under this item. (ii) Excavation required and cost of lugs is deem to be included in rate of the item. (iii) Contractor shall arrange the Welding machine on site for welding of detached Panel doors by providing MS hinges heavy duty and providing tower bolt for locking arrangement
M&L for taking shut down including repairing of feeder pillars out door type by providing connectors, copper lugs, nuts, bolts, etc of suitable sizes for incoming and outgoing UG cables including proper LT insulation tapes to cables which are deteriorated and cleaning the internal area of panel, cleaning the rusted parts by WD-40 and replacing the damaged spare parts like nuts, bolts , screws etc with new one including repairing of panel doors by welding broken hinges, providing new hinges where old hinge rusted and repairing the door locks / providing new locking arrangement including taking out incoming and out going cable burried in undergound cutting and providing new aluminium lugs and reconnected to bus bar/ MCCB`s/MCB`s all as specified and directed by Engr-in-charge. Note : (i) Feeder Pillar box in which repairing of internal wiring, welding of doors not required and not covered under respective item here-in-before above shall be measured under this item. (ii) Excavation required and cost of lugs is deem to be included in rate of the item. (iii) Contractor shall arrange the Welding machine on site for welding of detached Panel doors by providing MS hinges heavy duty and providing tower bolt for locking arrangement
M&L for Maintence and cleaning of surrounding area of sub stations, near LT panels, feeder pillars, transformer etc by cutting seasonal grass, bushes etc,including spreading of strong herbicides in order to stop the fast growth of grass/bushes around the feeder pillars and panels by employing skilled mazdoor including using own T&P as required to do the job and taking all precaution while men on working in sub station being dange zone all as specified and directed by Engr-in-charge. Note : As vegitation growth is very high in the Stn due to humid climate, area cleaning of installations can be repeated and to be done twice/thrice as per the requirement and directed by Eng in Charge.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed. [Cat No. CM91712OOKOOG of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed. [Cat No. CM92108OOM1OG of Make “L&T”/Schneider Model : Easy Pact CVS Cat Part No.LV516343 or equivalent Model of Make Legrand / ABB.]
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 200 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM92109OON1OG of Make “L&T/Schneider Model : Easy Pact CVS Cat Part No.LV525342 or equivalent Model of Make Legrand / ABB.] :
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 250 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM92109OOP1OG of Make “L&T/Schneider Model : Easy Pact CVS Cat Part No.LV525343 or equivalent Model of Make Legrand / ABB.] :
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 400 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM94105OOR1OG of Make “L&T/Schneider Model : Easy Pact CVS Cat Part No.LV540309 or equivalent Model of Make Legrand / ABB.] :
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 630 Amps and 36 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM94106OOT1OG of Make “L&T/Schneider Model : Easy Pact CVS Cat Part No.LV563309 or equivalent Model of Make Legrand / ABB.] :
Disconnecting and Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of any size complete all as directed.
M&L for relaying old serviceable UG cable of any size/ type on trenches/ wall/ roof etc. after necessary repair/ rerouting works complete all as specified and directed by Engr-in-charge. Note :- i) In relaying of cable old serviceable bricks, GI pipes obtained during taking out existing cable shall be reused. If required new bricks, sand, GI pipe shall also be use. New brick and sand to be measured and paid under relavant item seperately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 120 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
All as per Item No 41 here-in-before but size of cable 70 sqmm 3½ core, complete all as specified and as directed.
All as per Item No 41 here-in-before but size of cable 35 sqmm 3½ core, complete all as specified and as directed.
All as per Item No 41 here-in-before but size of cable 25 sqmm 4 core, complete all as specified and as directed.
All as per Item No 41 here-in-before but size of cable 16 sqmm 4 core, complete all as specified and as directed.
All as per Item No 41 here-in-before but size of cable 10 sqmm 4 core, complete all as specified and as directed.
M&L for detecting of fault in 1100V (E) LT cable of any size , 3½ core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced & cost of Jointing kit shall be measured & paid separately.
S& F SS enclosure for MCCB of rating 250 Amp In-built neutral Link for TPN system l IK08 and IP30 Protection having Louvers for better heat dissipation Suitable to accommodate upto 185 sq. mm. 3 1/2 core Aluminum armoured cable incl taking down unsv one and fixing serviceable/ new MCCB in enclosure and connectiing existing IC/OG cable with proper dimension lugs all as specified and directed. Make L &T Cat Part No. CM91003OOOO or equivalent in Havells /CG. Note : New MCCB shall be measured and paid seperately.
S& F SS enclosure for MCCB 125 Amp In-built neutral Link for TPN system l IK08 and IP30 Protection having Louvers for better heat dissipation Suitable to accommodate upto 70 sq. mm. 3 1/2 core Aluminum armoured cable incl taking down unsv one and refixing serviceable/ new MCCB in enclosure and connectiing existing IC/OG cable by providing lugs of suitable dimension all as specified and directed. Make L &T Cat Part No. CM90996OOOO or equivalent in Havells /CG. Note : New MCCB shall be measured and paid seperately.
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 6 sq. mm to 16 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0123 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 25 sq. mm to 50 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0130 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 70 sq. mm to 150 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0137 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 150 sq. mm to 185 sq. mm, complete all as specified and directed. Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Materials and Labour for Straight Through Joints, tubular sleeve type, for 1.1 KV Grade, underground cable including jointing kits and accessories complete for making joints, suitable for 3/3 ½ /4 core XLPE armoured, aluminium conductor cable, of size 240 sq. mm to 300 sq. mm, complete all as specified and directed. [Kit No.EPKJ 0144 of Make 'Raychem' or equivalent Model of Make M-Seal/3M]
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 40 to100 mm bore, galvanised steel tubing,and making good distrubed surfaces as per existing specification complete all as specified and directed.
Material and labour for 80 mm dia galvanized iron tube Medium grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Material and labour for 50 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Material and labour for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
Taking down old unsv/ corroded LT feeder pillar box/ DB Box/ Busbar Chamber of any sizes or types (after disconnection of all electrical connections) complete for replacement with new one all as specified and directed by Engr-in-Charge.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of Aluminium of ETP grade suitable for 600 Amps ( Size of aluminium strip should not be less than 60 x 10 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs , pad lock of size 50 mm , 7 lever of Make Goodrej for locking arrangement , PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:3:6 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. (A) Incoming/outgoing (i) MCCB 400 Amps rating, 4 pole , 415 V, AC, 50 HZ, thermal release range 320-400 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 KA, Conf to IEC 60947-2 including all accessories like spreader terminals and separator , with rotary handle etc. . Make : L&T Cat Part No. CM98403OOROOG --- 01 Nos with rotatary handle. (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp (v) Neon type for three phase. (vi) Slector switch - 2 Nos
Note:- (i) MCCB should be of Make : L&T/ Legrand /Schnider/Seimens. (ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vi) The rating of copper bus bar to out going MCCB / MCB`s shall not be less than 1.5 times the rated current of individual out going feeders/ MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s (ix) Rate of panel include dismantling of existing panel, demolition of existing PCC and refixing of all cables in panel which are dismantle & taking out from old unserviceable panel.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of Aluminium of ETP grade suitable for 200 Amps ( 4 nos Size of Aluminium strip should not be less than 25 x 05 mm for each phase and neutral) pre-wired with suitable size of Copper /Aluminium strip/ Copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs , pad lock of size 50 mm , 7 lever of Make Goodrej for locking arrangement , PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:3:6 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. (A) Incoming/outgoing (i) MCCB 63 Amps rating, 4 pole , 415 V, AC, 50 HZ, thermal release with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 10 KA, Conf to IEC 60947-2 including all accessories like spreader terminals and separator , with rotary handle et --- 01 Nos with rotatary handle. ii) Drawing of LT panel and make of items shall be get approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Rotary handle to be provided for all MCCB for control and operation of MCCB. (vii) Independent Amper meter with CTs to be provided for each out going feeder. (viii) Spreader terminals and Phase barriers to be provided with all MCCB`s (ix) Rate of panel include dismantling of existing panel, demolition of existing PCC and refixing of all cables in panel which are dismantle & taking out from old unserviceable panel.
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 25 X 4 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 25 x 4 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 32 X 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.
Supply and fixing in repair earth continuity conductor or main earthing lead fixed on porcelain to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip soldering to each joints with brass nut bolts all as specified and directed by engr in charge.
M & L for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m high from (above ground 7.5RM) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint black colour from ground level to 1.0 m high with writing Pole No. of suitable size of letters as directed. Note : Size of lettering and colours of paints will be directed by Engr-in-charge.
S & F in repair rotary handle for operating MCCB direct ROM type complete all as specified and directed by Eng in Charge.
S & F in repair rotary handle for operating MCCB direct Extended ROM type complete all as specified and directed by Eng in Charge.
M&L for fabricating door of feeder pillar box ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet , with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 by providing hinges complete all as specified and directed by Eng in Charge.
Supply and fixing in repair copper lug suitable of 25 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 50 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 95 Sqmm copper cable all as specified and directed
Supply and fixing in repair Aluminium lug suitable of 185 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 150 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 120 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 70 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 35 Sqmm copper cable all as specified and directed
Supply and fixing in repair copper lug suitable of 25 Sqmm copper cable all as specified and directed
Supply and Fix in repairs, On Load Change Over Switch in sheet steel enclosure, Four Pole, Current Rating 160 Amps, conforming to IS 13947 (Part 3)-1993; IEC: 60947-3, complete all as specified and directed. [Cat No. CO21600OSOO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs, On Load Change Over Switch in sheet steel enclosure, Four Pole, Current Rating 250 Amps, conforming to IS 13947 (Part 3)-1993; IEC: 60947-3, complete all as specified and directed. [Cat No.CO32500OSOO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs, power factor correction capacitors, box type, heavy duty, rating 15 kVAr, 440 V, complete all as specified and directed. [Cat No. Box Series: LTBCH of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
M&L for writing letters or figures Block, Roman, Italic or Indian) n.exc. 30 cm high with two coat synthetic enamel paint complete all as specified and as directed.
M&L for writing stops, commas, short lines, dashes, hyphens, brackets etc with two coat synthetic enamel paint complete all as specified and as directed at side.
S&F loop-inloop out fuse junction box of internal dimention 182x180x90mm made thermoplastic sheet with weather proof canopy and locking screw fitter with and including 50 Amp rated 4 way connectors for 3 phase and neutral incoming/outgoing, mounted in the box, fixing on street pole/rail pole including necessary aluminium clamps, suitable glands, lugs and GI nut and bolt including taking down old unserviceable junction box all as specified and directed. Make- Cape, Model-CJB012PS or equivalent make of Hansel/Sintex.
Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents. (a) Provide a prime cost of Rs.13,00,000.00 for supply only of spare parts suitable for various capacities of DG Sets, AMF Panel including all spare parts and Rewinding of Electric Motors/Alternators after dismantling and based on findings of the actual requirements of spares/burnt out windings for rewinding, through a BOO convened by the Accepting Officer.The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE. Rewinding of electric motors/alternators/dynamos/self starter shall be done through authorised Service Engineer of OEM or OEM Certified Agencies as approved by GE. (b) Bidder's/Contractor's quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidder's/Contractor's is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum inserted by MES under Column 5. However, the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum inserted by MES under Column 5. In case, the Bidder's/Contractor's quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .