| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC F NO A1 APURBA ENCLAVE BRINDABAN PATH RUPNAGAR KAMRUP GUWAHATI ASSAM 781005 | KAMRUP METRO | ASSAM | 781005 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹35.4 L+₹26,610.40 (0.76%)Rejected-Finance PINE DALE PINE MOUNT RIDGE SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | L2 | Rejected-Finance Other than L1 bidder |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
27 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
REPAIR/MAINT OF HT OVER HEAD LINES AND HT UG CABLES AND ALLIED WORKS AT HAPPY VALLEY AND SE FALLS UNDER GE SHILLONG
2023_MES_615569_1
8679/SHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Shillong
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Shillong
₹79,000
Yes
4 Nov 2023
25 Aug 2023
30 Sept 2023
25 Aug 2023
27 Sept 2023
8 Sept 2023
Amount
Dismantling existing steel poles/ struts, any size carefully including necessary excavation, demolition of concrete etc. and removing complete all as specified and directed.
Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside for re-use of serviceable sections within 50m and removal of unserviceable section all as specified and directed.
Dismantling ACSR conductor of any size from existing overhead service feeder etc all as specified and directed.
Dismantling of insulators any type any size complete all as specified and directed.
Taking down under ground XLPE insulated, screned PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 33000/11000 volts grade including bricks/covers complete all as specified and directed.
Taking down cable jointing kit for 33/11 KV grade cable for outdoor/ indoor / straight through heat shrink type joint complete with jointing material and accessories suitable for 1/3 core XLPE armoured Al conductor cable of size 95 to 300 sq mm complete all as specified and directed
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 185 sq mm 3 core complete all as specified and directed. (Note : PCC route indicators to be fixed on every 50 mtr distance duly written 'HT CABLE' on each route indicator and rate is deemed to be included in the quoted rate)
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 120 sq mm 3 core complete all as specified and directed. (Note : PCC route indicators to be fixed on every 50 mtr distance duly written 'HT CABLE' on each route indicator and rate is deemed to be included in the quoted rate)
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 95 sq mm 3 core complete all as specified and directed. (Note : PCC route indicators to be fixed on every 50 mtr distance duly written 'HT CABLE' on each route indicator and rate is deemed to be included in the quoted rate)
Supply, laying & testing cable 33000 Volts (E) XLPE insulated with Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape, cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments of size 240 sq mm 1 core complete all as specidied and directed.
Laying only serviceable HT XLPE cable of sizes 120/95 sqmm 3 core obtained from item No 1.00 here-in-before complete all as specified and directed.
Supply and fix cable jointing kit for 33 KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for single core XLPE, armoured, aluminium conductor cable of size 240 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed.
Supply and fixing cable jointing kit for 11KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor terminal heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sq mm complete all as specified and directed.
Supply and fixing cable jointing kit for 11KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm complete all as specified and directed.
Material and labour for steel tubular swaged pole 11 metre long type 410 SP-55 complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified and painting/numbering of pole as per existing poles as mentioned complete all as specified and directed. (Note: PCC cross arms insulator, ACSR conductor and earth work shall be measured and paid separately under relevant items)
Material and labour for aluminium conductor steel reinforced of all sizes complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exc. 1.5m depth but not exceeding 3 mtr depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard rocks complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm in hard/dense soil complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning to underground cable for protection with fine river sand over, UG cable laid in trenches and gently punned to cushioning to cable complete all as specified and directed. (Note: Thickness of sand cushion shall be 150 mm thick below cable, 80 mm above the cable and punned down to a thickness of 180 mm which shall be measured and paid.)
Material and labour for un-reinforced precast concrete cable cover, class HV, type I with peak, size 300mm x 180mm x 40mm complete with MES marking on the top of the cover complete all as specified and directed.
Material and labour for switch air break gang operated triple pole out door type unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (9 insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete and taking down old unserviceable all as specified and directed.
Supply and fixing Drop Out fuse (Copper) channel type fitted on two post insulator per pole per phase complete vertical type (6 insulators) connected with necessary nuts, bolts and brackets including testing confirming to IS 9835 rating 12 KV, 200 Amps made of Gun metal complete and taking down old unserviceable all as specified and directed
Material and labour for lightening arrester/surge protector 11 KV grade heavy duty , single pole , self supporting station class 65 KA capacity with all fittings complete and taking down old unserviceable all as specified and directed.
Material and labour for PCC (1:3:6) type C2 (using 40mm graded stone aggregates) as in foundation for stay set /Pole/ FPB etc complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping of pole including necessary form work as required complete all as specified and directed
Material and labour for 100 mm bore steel tubing medium grade ISI marked for protection of cable including necessary joint and clamps complete and taking down old unserviceable all as specified and directed.
Restringing and stretching of existing sagged ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connection complete all as specified and directed.
Material and labour for cross arms , bracing, supports , clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as directed including 2 coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Fixing only serviceable cross arms obtained from dismantling under item No. 2.00 here-in-before including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for Disc type insulators, porcelain, vitreous 145 mm height, 255 mm dia and socket type white, brown and green, 11000 volts grade, single disc assembly with tension clamps for conductors after dismantling unserviceable one complete all as specified and directed.
Material and labour for pin type insulator, porcelain, vitreous brown of size 150mm height, 150mm dia 11000 volts grade including one galvanized mild steel spindle with two galvanized iron washers and one galvanized iron nut complete all as specified and directed.
Material and labour for loop type insulator vitreous porcelain white or brown with over all dimension 90mmx140mm with 25.5 mm clearance hole complete all as specified and directed.
Material and labour for stay assembly complete with accessories as shown in electrical plate No.1 dia of stay 20mm 1830mm long including MS galvanized stay plate of size 300mm x 300mm x 6mm thick and galvanized thimble after dismantling of unserviceable stay set (above GL) complete all as specified and directed. (Note: Loop type insulator, excavation in earth work, PCC foundation shall be measured and paid separately under relevant item)
Supply and fixing Galvanised stay strand, 7/4mm including dismantling old one complete all as specified and directed.
Supply and fixing Galvanised Steel wire 4 sqmm as earth wire including dismantling old one complete all as specified and directed.
Shifting after disconnection of transformer from the existing site and install/ commission at proposed site outdoor/Indooe type HT 11KV/433V, 3 phase, 50 Hz with standard fittings up to 500 KVA complete all as specified and directed.
Labour for Cutting of tree branches near HT OH line and disposal of unserviceable material to a distance exceeding 50 m and clearing site complete all as specified and directed. (Note : One Span is length between 02 No poles and distance not exceeding 50 mtrs)
Material and labour for two coats of Aluminium paint after preparation of old surface of Steel/Iron electric poles exceeding 10cm in width or girth including pole fittings with two coat of Aluminium paint such as cross arms of any description anti climbing devices nut bolts etc and cement based paint on PCC coping and painting 05 Nos of strips of each 30cm height of Red & Black synthetic enamel paint alternatively above coping including numbering of poles as specified and directed.
Material and labour for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Material and labour for earthing complete with Copper plate electrodes of size 600mm x 600mm x 3.15mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to Copper strip of 20 mm x 3 mm earth lead by means of nuts bolts check nuts GI washers earth strip protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm including 8mm dia TMT bars 100 mm c/c both ways with one handle for lifting made out of 8 mm dia MS round bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers, necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed including demolition of existing one complete
Material and labour brick work with sub class B bricks straight or curved on plan exceeding 6 Mtr mean radius built in cement mortar 1:4 complete all as specified and directed.
Material and labour for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work, finished even & fair without using extra cement complete all as specified and directed.
Material and labour for hardcore of gauge not exceeding 63 mm graded stone aggregate deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
Material and labour for spray of agricultural based chemical inside the installation to control the growth of unwanted herb etc incl cleaning of the grass herbs bushes etc from the installation complete all as specified and directed.
Cuting of Grass/bushes at 2 pole structures and Compact Sub Stations in 2 meters perimeter with help of bush cutter/hand tools complete all as specified and directed.
Material and labour for attending fault of HT overhead lines by carrying out inspection/emergency inspection, inspection of insulators of HT overhead lines pole to pole carefully thoroughly after switching off by taking proper shutdown from Sub Station after wind storm, heavy rain,, thunder storms etc., check thoroughly by expertise team, tracing out the fault and restore the supply by necessary repairs i.e. applying DO fuses, jumpering, replacing the insulator, HT overhead lines incl meggering / servicing complete all as specified and directed. (Note : The damaged / worn out parts replaced will be measured and paid separately under relevant items.)
Testing of UG HT Cable by portable HT fault detector (11 KV line) and showing the fault/short circuit distance from either end without excavating UG cable and rectify the fault by excavating the area and jointing the cable for single length of cable between 2 Pole structure all as specified and directed. (Note : Earth work and jointing kit will be measured and paid separately under relevant items)
M/s A L Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .