Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹7.8 L+₹3,643.51 (0.47%)Rejected-AOC SUBHAS ROAD BANKURA 722101 W B | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹7.9 L+₹6,819.92 (0.88%)Rejected-Finance RAMPUR HAZRA LANE BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L3 | Rejected-Finance Rejected | |
| 4 | L4₹7.9 L+₹9,764.44 (1.25%)Rejected-Finance INDARAGORA BANKURA W B | BANKURA | BANKURA | WEST BENGAL | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹22,400
Closing Date
21 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, BMD, PHE, Dte
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Improvement of Yard lighting at Plasto industrial park w/s scheme at Barjora Block under Bankura Mechanical Division, P.H.E. Dte
2021_PHED_350468_4
WBPHED/EE/BMD/NIeT- 09 OF 2021-2022
Open Tender
MECHANICAL
Item Rate
60 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹22,400
Yes
17 Jan 2022
22 Nov 2021
24 Dec 2021
22 Nov 2021
21 Dec 2021
22 Nov 2021
180 days
Amount
Supply of swaged / stepped type steel tubular pole of 8 m long (410‐SP‐11) conformed to IS : 2713-1980. The length of bottom section shall be 4.5 mtr, middle section shall be 1.75 mtr & top of 1.75 mtr. The bottom section of the pole shall be 114.3 x 4.50mm dia, middle section of the pole shall be 88.9 x 4.50 mm dia & the top portion shall be 76.1 x 3.25 dia, sheet of 3.65 mm thick . 1.5 mtr. long MS bracket made out of 40 mm dia MS pipe shall be fixed on top of the pole for fixing light fiottings. The MS mounting bracket shall be fixed on top of the pole weight approx 83 Kg N.B- Certificate of Pole from manufacturer should be produce at the time of delivery
a) Single Arm
b) Dauble Arm( 90 deg/180deg)
Supply delivery & fitting fixing of Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set. M.No-BRP410 LED 094 CW HE MR FG S2 PSU GR
Supply and delivery of 6 sq.mm. 4 core PVC insulated XLPE Ar. AL conductor cable, As Per IS-7098 (Part 1) 2011 with Up To Date Amendment
Earth work in excavation of foundation trenches or drain in all sorts of soil ( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
a) Erection of Single tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
b) Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 250 x 250 x 100mm
Supply and inter connection of power line from light fixture to jointing box by the 1.5 sq mm x 2 nos pvc insulated HRFR 1.1 kv grade copper flaxible cable
Supply and fitting fixing of 20mm dia GI pipeMedium quality (Non TATA) from muffing to Joint box
Supply and delivery at site of 25mm Ф G.I pipe Medium quality (Non TATA) for laying Cable ( Road corossing)
a) Laying through Underground Trech Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
b) Laying on Wall / surface with Saddles / clamps Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F M S saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
a) Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 4 core 6 sqmm cable
b) Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : i) 4 core 6 sqmm cable
Painting of Steel Tubular Pole of lengths and no. of coats of paint,as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole
i) One coat of red lead/Zinc chromate priming
ii) 1st coat of synthetic enamel paint over the primer
ii) 2nd coat of synthetic enamel paint over the 1st coat
Excavation of soil for installation of Earth Electrode and filling & ramming. i) For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
a) Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. i) 63Amp 4 pole
b) Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection A) 40 A (TPN)
c) Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmentt 4 way Enclosure (DHDLVDRWAOFO04)
Comissionig the all intallation up to satisfaction of E.I.C
Add: 12% GST
Add: 1% Cess
RAJIB COMPANY
ABHIJIT MUKHERJEE
M/S NABIN GOPAL SENGUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .