Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹31.4 L+₹3.1 L (10.9%)Rejected-AOC | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹32.5 L+₹4.2 L (14.8%)Rejected-AOC | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹33.8 L+₹5.5 L (19.3%)Rejected-AOC | L4 | Rejected-AOC Quoted L4 |
Tender Value
₹43.2 L
EMD Value
₹86,400
Closing Date
3 Mar 2022, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
SPECIAL REPAIR TO AIRMEN MESS AND BILLETS AT AF STN HIGHGROUND
2022_MES_505676_1
GE(AF)/CHD/T-54/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Highground
All as per NIT and Tender document
9 documents required · 9 mandatory
₹500
GE (AF) Chandigarh
₹86,400
Yes
27 Apr 2022
3 Feb 2022
5 Mar 2022
3 Feb 2022
3 Mar 2022
17 Feb 2022
3 Feb 2022 - 9 Feb 2022
Amount
Demolition of un reinforced cement concrete of any description or as roof padding and coping concrete with app membrane/ rendering on parapet wall /roof treatment and in any position not otherwise specifically provided for and remove all the debris out of MoD land complete all as specified and as directed
Dismantling bricks tiles or concrete tiles single layer on roofs and removal, complete all as specified.
Demolition of mud phuska on roofs any thickness including mud plastering (whether full thickness removed or only a part thereof) and removal to a distance exceeding 100 metre, complete all as specified
Taking down existing mud plaster /tarfelt including roof treatment bedding on brick or stone surfaces , etc. including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and as directed.
Material & labour roughening of surfaces of old concrete floor/slab by wire brushing, sweeping, cleaning and washing down to remove all loose dust etc, and brushing neat cement slurry @ 3.00 kg/Square Metre on floor/roof surface, complete all as specified.
Material & labour plain cement concrete (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in padding to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified.
M & L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) mixed with 3% of WPC and finishing the surface even and fair without using extra cement complete all as specified.
Material and labour, cleaning the new or old pastered or concrete surfaces and water proofing treatment of roof horizontal surfaces consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) A layer of minimum 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed. (c) Finally finished with a coat of bitumastic aluminium paint over the membrane.
Material and labour, cleaning the new or old pastered or concrete surfaces and water proofing treatment on vertical surfaces of roof consisting as under including taking down old membrane( as in verticla surfaces ):- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) A layer of minimum 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed. (c) Finally finished with a coat of bitumastic aluminium paint over the membrane.
Material & labour, 40 mm thick brick tiles laid on roof and including 15 mm thick screed bed in CM (1:6) and jointed grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement over and complete all as specified and directed.
Material & labour, 40 mm thick brick tiles(old retreived servicable tiles) laid on roof and including 15 mm thick screed bed in CM (1:6) and jointed grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement over and complete all as specified and directed. Note : The cost of cleaning and washing of brick tiles obtained from Ser no 2 for re use shall be deemed to be included in the unit rate quoted by the tenderer.
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls, 110mm single socketed
S/F PVC (SWR) bend 110 mm
Disconnecting existing water tanks of capacity exceeding 250 litres but not exceeding 500 litres, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting, if required, reconnecting and refixing in position (cleaning, repairing etc to be measured separately) complete.
Disconnecting existing water tanks of capacity exceeding 500 litres but not exceeding 1000 litres, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting, if required, reconnecting and refixing in position (cleaning, repairing etc to be measured separately) complete.
Disconnecting existing water tanks of capacity exceeding 1000 litres but not exceeding 2000 litres, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting, if required, reconnecting and refixing in position (cleaning, repairing etc to be measured separately) complete.
Dismantling water tanks of capacity exceeding 250litres but not exceeding 500litres complete.
S&FRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity, hoisted and fixed in position including connecting up pipes complete.
Dismantling water tanks of capacity exceeding 500 litres but not exceeding 1000 litres complete.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity, hoisted and fixed in position including connecting to pipes complete.
S&F in repairs ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, ISI marked (Minimum weight 210 gms), screwed & suitable for iron pipe 20 mm bore, complete all as specified.
S&F in repairs 20mm Gun metal,globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete
Demolition of un reinforced cement concrete of any description or as roof padding and coping concrete with app membrane roof treatment and in any position not otherwise specifically provided for and remove all the debris out of MoD land complete all as specified and as directed
Demolition of lime concrete/ lean concrete/ brick bats from floor/sunken portion exc. 15 cm thickness (above ground level), including removal of rubbish outside MoD land, complete all as specified.
Demolition of brick work built in cement mortar incl cleaning for re use etc all as directed
Material & labour roughening/preparing of surfaces of old/new concrete floor/slab/wall by wire brushing, sweeping, cleaning and washing down to remove all loose dust etc, and brushing neat cement slurry @ 3.00 kg/Square Metre on floor/roof surface, complete all as specified.
M&L for water proofing treatment to sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make as approved in Technical Instruction 5/ 2003:- (a) 15 mm thick plaster (1:4) in cement sand mortar with integral water proofing compound 2 % by weight of cement on floor and wall, finishing the surfaces even and smooth without using extra cement. The surface shall then be cured and allowed to dry. (Note: Supply only water proofing compound shall be measured and paid separately). (b) First layer of slurry of cement @ 0.488 Kg/Sq.m mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sq.m. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @ 0.242 Kg/Sq.m mixed with Acrylic based polymer modified cementitious composite compound @ 0.126 Kg/Sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
M&L for lean concrete (1:5:10), type E-2, using 40 mm brick coarse aggregate, as in sunken portion/sub base, complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick, PCC (1:2:4), type B-0 (12.5mm graded crushed stone aggregate) as in flooring finished even & rough to receive the bedding mortar, complete all as specified.
Supply only integral water proofing compound, complete all as specified.
S&F steel water tubes, 40 mm bore, medium grade, galvanized, as in spout for sunken floor, fixed in wall, inside end fixed with wire netting and external beveled edge at 45 degree, complete all as specified and directed by Engineer - in -Charge.
M&L for brick work with sub class 'B' brick straiight orcurved on plan exceeding 6m mean radius as in half brick thick wall in CM(1:4) all as directed.
M&L for brick work with sub class 'B' brick (except bricks) straiight or curved on plan exceeding 6m mean radius as in half brick thick wall in CM(1:4) all as directed. Note:- Serviceable bricks retrieved from demolition here-in-before shall be used after proper washing.
M&L for brick work with sub ckass 'B' brick straiight or curved on plan exceeding 6m mean radius in CM(1:6) as in full brick walling using old size brick all as directed.
M&L for rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4), and finish the surface even and fair, complete all as specified. Note : The rate quoted by the Contractor is deemed to be included necessary scafolding and form works up to 5 mtr height.
M&L for preparation and applying three coats of white wash on new plastered surface of wall
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L for Non - skid Coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm joint free as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor etc laid over and including 15mm thick screed bed in CM 1:6 set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete.
M&L for galzed ceramic coloued tiles in verticle surfaces 450x350x7mm thick over and including 10mm thick cement plaster in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid,bedded and pointed in cement mortar, complete all as specified and directed
M&L for machine cut Kota stone slab, 15mm to 20 mm thick as in flooring, laid over and including cement screed bed 15mm thick in cement mortar (1:6), and jointed with grey cement slurry mixed with pigment to match the shade of the slab including, rubbing and polishing (granite finish polish) complete, all as specified & directed.
M & L for Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite 20 mm thick complete, all as specified & directed.
Rounding to edges of stone slabs18 to 20mm thick as in in steps, jambs, pillars, cokking plateforms and likes complete all as specified
Taking down chowkhats or frames with shutters without taking off shutters from the frames, area not exc. 1.5 Sqm each and removing from the site including cutting holes in brick walls built in cement mortar depth ecx half brick but n exc one brick for taking out hold fasts and making good dismantled portion in CM 1:3 or in PCC 1:2:4 type B-1 after inserting new hold fast/chowkats , complete all as specified and directed.
Supply and fixed Factory made PVC door frame of size 50mm X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube. Fixing in opening as per specification and all as per drawing complete all as specified
S&F factory made solid PVC moulded door shutter 28 to 30mm thick (stiles), with 2,4, or 6 panel design with 2mm thick moulded prelam PVC Sheet on front face and 2mm thick plain colour PVC sheet on back face fixed to frame at site as per specification & drawings.
S&F 150 mm aluminium anodised, barrel tower bolts of extruded section.
S&F 125mm extruded aluminium alloy handles, fabricated type, anodised.
S&F 100mm alumimum butt hinges, fabricated type
Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling, floor etc., including removal from site, complete all as specified.
Taking up or down 20 mm bore steel tubing with connections or fittings from wall, ceiling, floor etc., including removal from site, complete all as specified.
Cutting chases, pinning in brick wall , making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth for 15 to 50mm GI/PVC pipes.
S&F Steel water tubes, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, of 15mm dia complete all as specified and directed
S&F Steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, complete all as specified.
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, of 20mm dia complete all as specified and directed
S & F in repairs bib taps, cast copper alloy, chromium plated, fancy type, screwed down, with crutch or butterfly handle, screwed for 15 mm bore iron pipe or for brass ferrule and complete all as specified.
S & F in repairs stop valves,/Angle velve cast copper alloy, chromium plated, fancy type,screwed down, with crutch or butterfly handle, screwed for 15 mm bore iron pipe or for brass ferrule and fixed in repairs, complete all as specified.
S & F in repairs pillar taps, 15 mm dia bore cast copper alloy chromium plated fancy type, with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs, complete all as specified.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm
S&F Vitreous china wash basin of size (550 x 400 mm), white, flat back, supporting on and including suitable angle iron bracket, including 32mm dia CP brass coupling, along with PVC waste pipe complete, including connection to pipe etc, with and including 15mm dia 450mm long PVC connection pipe with steel check nut (exluding taps) including & pinning in ends of brackets and taking down and removal of old wash hand basin , complete all as specified.(Make CERA, cat no S20401102) or equivelant)
S&F in repair Vitreous China squatting pan, `Orrisa' pattern, size 580 x440 mm white, with integral foot rests (excluding flushing cistern and flush pipe but including CI P/S trap) set and jointed including embedding in concrete complete all as specified.(Make-CERA, Cat no S3010105) or equivelant
S&F in repairs vitreous china wash down water closet (pedestal pattern) , of colour snow white, of size 570x460x380mm and including plastic seat cover of same colour, (Make CERA, Cat No 1050106 Strap) or equivalent complete all as specified and as directed
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 Ltr capacity, low level, white, with inlet,ball valve, float and handle including brackets, low level fluslhing cistern (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever, if any and fixing complete (Make - CERA, Cat No B1020102 cistern) or equivelant)
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in trenches or in floors, 75mm bore. including taking down old pipes and ncluding necessary excavation, return filling and demolition of PCC etc if required complete all as specified and directed
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors, of 110 mm bore including taking down old pipes and ncluding necessary excavation and demolition of PCC etc if required complete all as specified and directed
S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down old pipes and ncluding necessary excavation, return filling and demolition of PCC etc if required complete all as specified and directed
S&F PVC (SWR) vent cowl 75mm bore
S&F PVC (SWR) floor trap plain 75mm with grating including jointing with solvent cement
Supply only Nitozinic anti corrosion primer of M/S FOSROC or equivelent as aprroved by GE complete all as specified and directed
S&F 100x100mm Salt-glazed stoneware gully traps, square or round mouthed, type `P' complete all as specified and directed
M&L for 75mm bore Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4)
Supply & fixing grating doom 125 mm dia of PTMT (medium weight 40 gms) complete
S&F 15mm dia chromium plated Health flaucet alongwith 1m flexible pipe complete
S & F in repairs Vitreous china urinal, half stall type, flat back, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, grating and union for discharge pipe, CP Urinal spreader, CP screws etc complete all as specified and as directed.
S&F Vitreous china wash basin of size (630 x 450 mm), white, flat back, supporting on and including suitable angle iron bracket, including 32mm dia CP brass coupling, along with PVC waste pipe complete, including connection to pipe etc, with and including 15mm dia 450mm long PVC connection pipe with steel check nut (exluding taps) including & pinning in ends of brackets and taking down and removal of old wash hand basin , complete all as specified.(Make CERA, or equivelant)
Taking down and refixing existing servicable Vitreous china urinal, half stall type, flat back, white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, grating and union for discharge pipe, CP Urinal spreader, CP screws etc complete all as specified and as directed. of any discription complete and refixing the samesingat
S/F in repairs Concussive push button taps of cast copper alloy, screwed for iron pipe 15 mm bore complete.
SS & F in repairs sop valves/Angle cock, cast copper alloy, screwed down, with crutch or butterfly handle, screwed for 15 mm bore iron pipe or for brass ferrule and fixed in repairs, complete all as specified.
S & F in repairs stop valves, cast copper alloy, fancy type chromium plated with long shank and cup (Concealed type), screwed down, with crutch or butterfly handle, screwed for 15 mm bore iron pipe or for brass ferrule a, complete all as specified.
S & F in repairs Flush pipe of PVC 32 mm dia suitable for urninal/WHB
S&F Brass chromium plated shower rose 125mm size, with Arm swivel joints, including fixing to steel pipe or union complete all as specified and directed
S&F High density polyethylene pipes (HDPE) 40 mm bore of pressure rating 6 Kgf/Sqcm, fixed complete to walls,ceiling or in floors etc with necessary fittings such socket, L Bow, Tee, Reducer etc complete.
S&F Brass chromium plated bottle trap for wash basins with inlet and outlet, screwed for pipe or connections including necessary packing, union and cap, 32mm bore complete.
S & F Shelf of PTMT fixed with and incl chromium plated brass screws and wooden /plastic cleats (Min wt 300gms) complete
S & F in Brass Chromium Plated Tubular Towel Rail, 20mm dia, D Type, 600 mm long between flanges complete all as specified and as directed.
S & F f Steel window with side hung shutters Factory made including box type hinges with steel handle and steel peg stay complete with glazing bars devetailed or welded.complete all as specified and directed.
S & F Steel window with side hung shutters Factory made including box type hinges with steel handle and steel peg stay complete w/o glazing bars devetailed or welded complete all as specified and directed.
S & F Steel ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pulley wheel, complete all as specified and directed.
Galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples
Sheet glass ordinary quality and glazingwith oil puttyin square n.exc 0.50 sqm in each pane in 3 mm thickness
M&L preparing new steel surfaces and applying two coats of synthetic enamel paint over one coat of redoxide primer area Exc 10 cm width or girth
Preparation of old painted wall surfaces after removal of existing treatment completely and applying two coats of oil bound distemper over a coat of primer complete.
M & L for applying two coats of synthetic enamel paint on wooden surfaces over 10cm width or girth including preparation old surfaces complete all as specified
M & L for applying two coats of synthetic enamel paint on steel surfaces over 10cm width or girth including preparation old surfaces
Taking down cement plaster on brick or concrete surfaces of wall/ceiling and likes including racking out joints, hacking for keys scrubbing down with water etc any description , complete all as specified and directed. Note : The rate quoted by the Contractor is deemed to be included necessary scafolding and form works up to 8mtr height.
M & L for rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified.
M & L for rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) mixed with 3% of WPC finished even and fair without using extra cement , including necessary scafolding and form works, upto first floor complete all as specified complete all as specified.(Note : WPC shall be measured and paid seperately)
M & L for Rendering 10 mm thick in cement mortar (1:3) mixed with 3% WPC as on concrete surfaces (such as Top & side of chhaja,facia,sofit/ceiling etc) finished even and smooth without using extra cement, complete all as specified.(Note : WPC shall be measured and paid seperately)
M&L for preparation and applying two coats of distemper oil emulsiion over a priming coat to distempring over new plastered surface of wall
M&L for preparation and applying two coat of distemper oil emulsiion over a old treated plastered surface of wall
M&L for preparation and applying two coats of cement base paint over new plastered surface of wall/ceiling
All as per item No.103 here-in-before but on ceiling
M&L for preparation and applying two coats of cement base paint over old treated plastered surface of wall
Demolition of Reinforcement cement concrete of any description and in any position not otherwise specially provided for as in isolated wall/windows, chhaja, facia,Balconies, precast cover slab etc complete all as specified
M&L for RCC (1:1.5:3) type A1, using 20mm graded crushed stone aggregate as in Chhaja, fins, louvers, roof projection, beam and lintel after removing of loose concrete and preparation of surface by application of derusting chemical such as Dr Fixit rust remover or equivelent and welding additional main bars/distribution bars, if found necessary by inserting to adequate depth in beam by drilling, priming reinforcement bars old/new with a coat of anti corrossion Nitozinic primer of M/S FOSROC, including necessary scafolding and form works, upto first/ floor complete all as specified . Note : 1. Rate include for necessary scafolding. 2. Reinforcement will be ,measured & paid separately. 3.Nitozinic primer will be measures and paid separately
M&L for RCC (1:1.5:3) type A1, using 20mm graded crushed stone aggregate as in Chhaja, fins, louvers, roof projection, beam and lintel after removing of loose concrete and preparation of surface by application of derusting chemical such as Dr Fixit rust remover or equivelent and welding additional main bars/distribution bars, if found necessary by inserting to adequate depth in beam by drilling, priming reinforcement bars old/new with a coat of anti corrossion Nitozinic primer of M/S FOSROC, including necessary scafolding and form works, upto second floor complete all as specified . Note : 1. Rate include for necessary scafolding. 2. Reinforcement will be ,measured & paid separately. 3.Nitozinic primer will be measures and paid separately
M&L TMT steel bars, 8mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.90mm dia complete as in reinforcement to concrete all as specified and as directed.
Taking down carefully with battens/ PVC surface/ concealed conduit unserviceable copper/ aluminium point wiring (light, fan, socket) complete including fittings such as switches, ceiling roses, pendants, socket etc. and removing unserviceable material from site and making good disturbed surfaces of walls, floors etc. complete all as specified and directed.
Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in and including 20mm dia nonmetallic rigid PVC conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. NOTE: (a).The quoted rates includes the cutting chasis for conduit and sunken boxes.
All as per item No.111 here-in-before but point wiring for one 5Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 111 here-in-before but point wiring for one 5Amps socket outlet point on d same board controlled by one single pole, one way switch complete all as specified.
All as per item No. 111 here-in-before but point wiring using 2.5 sqmm as main wire & 1.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No.111 here-in-before but point wiring using 4sqmm as main wire & 2.5Sqmm as continous earth wire, for one 15Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
S & F Switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified.
S & F Switch piano, flush type, single pole, one way, 15 Amp 230volts complete all as specified.
S & F Socket outlet multipurpose 3 pin, 5 Amp and 2 pin 5 Amp, flush type, complete all as specified.
S & F Socket outlet multipurpose 3 pin 5 Amp & 15 Amp, flush type, complete all as specified.
S & F Ceiling rose, two to three terminals, PVC/ isolated body, complete all as specified.
Supply and fixing Sheet metal enclosure (DB) single phase & neutral, double door 2 way, 240 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete all as specified and directed including taking down old DB complete
S & F MCB 32/ 40 Amp, 230 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete including taking down old MCB all as specified.
S & F MCB 6 to 32/40 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete including taking down old MCB all as specified.
M & L sub main wiring with 4runs of 6 sqmm PVC insulated unsheathed 1100 volt grade multistranded copper conductor including PVC conduit suitable size and provision of 2x4sqmm PVC insulated unsheathed single core copper conductor as earth continuity , connected to earth dolly inclusive of all accessories complete including taking down old submain wiring all as specified.
M & L Sub main wiring with two single core 4 Sq.mm (nominal area) PVC insulated and unsheathed cables with stranded copper FR conductor in PVC conduit including one run of continuous PVC insulated FR copper stranded cable of wiring size 2.5 Sq.mm for earth continuity , connected to earth dolly inclusive of all accessories complete including taking dwon old submain wiring all as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 3mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI wire 4mm dia by means of bolts, nuts, check-nuts and washers of galvanized iron and of earth wire protected by galvanized iron pipe light grade 15mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 5 of SSR-2009 (Part-I).
Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking dwon old light fittings complete
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep heavy duty ®with, blades, and frame and louvers
Supply and fixing Sheet metal distribution board TPN, with double door,8 way, 415 volt with 200 Amps rated bus bar & IP 54 protection, including taking out old unserviceable complete including taking down old DB all as specified and directed by Engineer-in-Charge.
Supply only MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs,including taking dwon old MCB complete all as specified.
Triple pole and earth encolsure with a three pin and earth plug with socket i complete with one triple pole MCB TP 32A including taking down old DB
Note:- Amount of credit of Rs.47098.00 for retrieved materials is mentioned in Schedule of Credit Page No 120 of tender documents in pdf form which will be deducted offline while acceptance of tender.
R K Enterprises
N.N.CONSTRUCTION
KG BUILDERS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .