Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 177 GAUTAM BUDH NAGAR SECTOR 66 GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Rejected-Technical | Rejected-Technical NOT QUALIFY |
Tender Value
₹27.7 L
EMD Value
₹27,730
Closing Date
5 Nov 2024, 12:00 pmClosed
SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
2 WORK IN HEAD STRENGTHENING OF 33 KV LINE DPR SL NO 1 2 UNDER EUDD 7 NOIDA
2024_PVVNL_968042_1
27/EUDC-I/2024-25/NOIDA (WORKS)
Open Tender
Electrical Works
Item Rate
IN AREA OF EUDSD-II/XIII, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EE, EUDD-VII, NOIDA
₹27,730
11 Nov 2024
24 Oct 2024
5 Nov 2024
24 Oct 2024
5 Nov 2024
24 Oct 2024
Amount
Cartage of following material from ESC Noida/Sahibabad/ Ghaziabad /Any other ESC of Meerut Discom to JE Store and from JE store to various points site of work including loading and unloading at both ends : -
33 KV XLPE Cable 3x300 Sq.mm.
11 KV XLPE Cable 3x185 Sq.mm.
O/D cable jointing Kit suitable for 33 KV 3x300 Sq.mm. XLPE cable
O/D cable jointing Kit suitable for 11 KV 3x185 Sq.mm. XLPE cable
S/T cable jointing Kit suitable for 11 KV 3x185 Sq.mm. XLPE cable
ACSR Dog Conductor
33 KV Line Isolator
Polymeric 11 KV Pin Insulator.
11 KV Disc Insulator T&C Type 4500KG.
33 KV Line Isolator Structure.
ST Pole 11 Mtr. long
MS Angle Iron 65x65x6mm, 4300 mm cable holding.
Top Channel 125x65x6mm, 3200 mm.
Top Channel 100x50x2040 mm.
Dropper Channel 100x50x2000 mm.
Disc Insulator 70KN (B&S Type) 7000 Kg.
Disc. Fitting Dog/Racoon 7000 Kg.
Polymeric 33 KV Pin Insulator.
Stay Set complete.
Earthing complete.
Providing & Fixing of following material of standard make / best quality for complete the work as per site requirement by the contractor at his own cost : -
Earth wire clamp with nut & bolt.
Clamp with nut & bolts.
PG Clamp
Stone pad 300x300x75mm.
Number plate
Danger board with clamp
G.I. pipe 6" Dia 3 Mtrs. Long.
Aluminium Paint
Barbed Wire
Concreting of support.
Cable RCC / Stone Route Marker yellow colour with proper marking.
Bolt, Nut and Washer.
Red Oxide Paint.
O/D cable jointing Kit of Raychem/ 3M/ Denson/PVVNL approved make suitable for 33 KV 3x300 sq.mm. XLPE cable
O/D cable jointing Kit of Raychem/ 3M/ Denson/PVVNL approved make suitable for 11 KV 3x185 sq.mm. XLPE cable
S/T cable jointing Kit of Raychem/ 3M/ Denson/PVVNL approved make suitable for 11 KV 3x185 sq.mm. XLPE cable
Holding clamp with nut & bolt.
Fixing of following material as per site requirement complete in all respects : -
O/D cable jointing Kit suitable for 33 KV 3x300 Sq.mm. XLPE cable
O/D cable jointing Kit suitable for 11 KV 3x185 Sq.mm. XLPE cable
S/T cable jointing Kit suitable for 11 KV 3x185 Sq.mm. XLPE cable
33 KV Line Isolator
33 KV Line Isolator Structure.
The Excavation of foundation pit in CC road/ mix soil/ normal soil/ soft & hard rack by using heavy duty compressor and its back filling and leveling etc. The size of the pit will be 600x600x1800 mm for each pole and having a depth of 1/6 of the full length of the support.
Fabrication & fixing of MS channel / Angle as per site requirement complete in all respects.
Erection of Double pole structure on 11 Mtr. long ST Pole for 33 KV line including fixing of all accessories of 33KV line as per RESPO schedule Complete in all respects.
Grouting of each pole (In ratio of 1:4:8 in Cement, sand and Brick Ballast) in size 450mmx450mmx1800 mm as per RESPO schedule Complete in all respects.
Construction of Plinth in size 450x450x300 mm of each (0.880 Cu.m) pole above the ground level (In ratio of 1:3:6 in Cement, sand and Brick Ballast) as per RESPO schedule Complete in all respects.
Grouting & concreting of stay rod 1800x16 mm & Fixing, Tighting & nozzling of stay wire 5 kg with the pole of required tension with clamps, bolt & nut.
Excavation of earth and driving of M.S. earthing rod of size 20x2500 mm in earth and jointing through G.I wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts etc. as per RESPO schedule Complete in all respects.
Drilling of dia 160 mm by trenchless (HDD method) by horizontal boring machine at a depth of 1.5 mtrs below the ground level for S/C laying of 33 KV / 11 KV cable complete in all respects.
Providing of 06 Mtr long pieces of HDPE pipe PN 6, PE 80, 6 inch Dia (PVVNL approved) after inspection of competent committee at manufacturing site of the items with actual guarantee period.
Laying and interconnecting of above 06 Mtr long pieces of HDPE pipe PN 4, PE 63, 6 inch Dia (PVVNL approved) in trench for S/C laying of 33 KV / 11 KV cable complete in all respects..
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop.
Providing of HDPE Socket suitable for HDPE pipe 6 inch dia.
Fixing of above HDPE Socket 33 KV / 11 KV XLPE Cable and 6inch dia pipe.
Road Restoration charges as per authority norms for hot mixed pakka road / CC road / kaccha road / mix soil/ normal soil/ soft & hard rack after cable laying as it is when start of work.
Laying and pulling of 33 KV / 11 KV XLPE Cable through HDPE pipe complete in all respects.
Laying of 33 KV XLPE Cable 3x300 (700 Mtrs.) / 11 KV XLPE Cable 3x185 Sq.mm. (600 Mtrs.) at D/P & in loop & riser complete in all respects.
Hi port test for 33 KV 3x300 sq.mm XLPE cable.
Hoisting of 33 KV 3x300 sq mmXLPE cable on double pole structure through GI pipe 6 inch dia 3 mtr long fixed on pole structure including its jumpering complete with clamps, bolts and nuts.
Jumpering by ACSR Dog Conductor complete in all respects.
ARMAMENT SECURITY SERVICES
RAKSHA POWER INFRATECH
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .