Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹42.4 L+₹2.5 L (6.31%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹43.5 L+₹3.6 L (9.09%)Rejected-Finance ROWRIAH CHARIALI JORHAT ASSAM PIN 785004 | JORHAT | JORHAT | ASSAM | 785004 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹44.1 L+₹4.3 L (10.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹47.4 L+₹7.6 L (19.0%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
3 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) JORHAT
JORHAT
SMART PERIODICAL SERVICES TO OTM AND MD ACCN OF DIAMOND JUBILEE COMPLEX, OMQ, 16 PSU AND MES INSTALLATION AT AF STN JORHAT UNDER GE (AF) JORHAT
2023_MES_618410_1
8565/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) JORHAT
9 documents required · 9 mandatory
₹500
GE (AF) JORHAT
₹80,000
16 Dec 2023
12 Sept 2023
5 Oct 2023
12 Sept 2023
3 Oct 2023
27 Sept 2023
Amount
Taking down cement plaster of any description on brick walls or on concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc. and removing same from the site(s) complete all as specified and as directed.
M&L for single component polymer modified repair mortar with compressive strength minimum 38 Mpa at 28 days (ASTM C 109.99) and tensile strength minimum 2.5 Mpa (ASTM C 307) upto 15mm in a single coat @ 34 Kg/sqm for 15mm thickness as per manufacturer instructions complete all as specified and as directed.
M&L for preparation of new plastered surface of wall and applying two coats of oil bound distemper using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. Note. Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system
M&L for waterproof cement based putty @ 1 Kg/Sqm (undiluted) of average thickness 1.0mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500 rpm, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 litres per minutes with a maximum pressure 3300 PSI. Step 3 : Allow 6-8 Hrs time to dry the putty surface.
M&L for applying one coat of oil bound distemper using airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed. NOTE:- Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
M&L for applying one coat of oil bound distemper over old surfaces using airless spray technology with max working pressure of 3300 PSi and capable of operating single spray gun with maximum material hose length of 30m with spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure over a coat of water based interior grade primer @ 0.8 litres (undiluted)/10 sqm in ratio 1:1 with water and paint usage and shall be done by certified painter of manufacturer and as mentioned in PS and accesories. Applying distemper should be able to spray in hard to reach areas and penitration of distemper on the surface complete all as specified and as directed. NOTE : Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer.
M&L for applying one coat of distempering over old surfaces with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of pproved manufacturer of required shade and colour complete as per manufacturer's specification complete over a coat of primer after complete all as specified and directed.
M&L for two coats of smooth interior acrylic emulsion with rich matt finish having VOC less than 50 grams/litres complying water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of 1 litres per minute (minimum) having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint and as per manufacturer instructions complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar (1:4) on walls finished fair and even complete all as specified directed.
M&L for 5mm thick rendering in cement mortar (1:3) on ceiling finished fair and even complete all as specified directed.
M&L for preparation new plastered surfaces and applying two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and as directed.
M&L for preparation new plastered surfaces on ceiling and applying three coats of white washing complete all as specified and directed.
M&L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifications, Anti Algal properties in two coats @ 1.79 litres (undiluted)/10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both the coats of paint completecomplete after complete removal of existing treatment all as directed.
M&L for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls by washing, rubbing down etc. and applying one coat of cement base paint all as specified and directed.
M&L for applying one coat of synthetic enamel paint (first grade quality) after preparation of old painted wood and wood based surface of any description not otherwise described over 10cm width or girth complete all as specified and directed
M&L for one coat of synthetic enamel paint (first grade quality) on old steel surfaces over 10cm width or girth not otherwise described after preparation of old steel surface complete all as specified and directed
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters, etc. including brooming and brushing by steel wire brush, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified and as directed
All as per Serial item No. 18 here-in-before but applying as on ceiling.
M&L for removing plant including roots by dismantling of brick work PCC/RCC including necessary saffolding any type in any location/position i.e. roof, parapet wall near pipes, etc. and applying acid after removing roots for preventing the regrowth and making good to disturbed portion using PCC (1:2:4) type B-0 (using 12.5mm stone aggregate) and 10mm thick plaster in cement mortar (1:3) of size of disturbed portion 150x150x 200mm complete all as specified and as directed.
M&L for writing letters of Figures (block, Roman, Italic or Indian) not exc. 30cm height complete all as specified and as directed. Note : The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
AJOY DUTTA CHOWDHURY AND CO
KAY CEE CO. INDIA
Chief Builders &Consultants
A K DUTTA CHOWDHURY AND CO
A M CHOUDHURY AND CO
M/S GOPAL ROY AND CO
M/S DHAR AND DHAR
Bidder Name
KAY CEE CO. INDIA
A K DUTTA CHOWDHURY AND CO
A M CHOUDHURY AND CO
AJOY DUTTA CHOWDHURY AND CO
M/S GOPAL ROY AND CO
PEE BEE INDIA
M/S DHAR AND DHAR
Chief Builders &Consultants
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .