Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC | ₹44.6 L Quoted ₹45.3 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹46.3 LRejected-Finance | ₹46.3 L | L2 | Rejected-Finance Rejected due to Bidder quoted higher rate |
| 3 | L3₹47.6 LRejected-Finance | ₹47.6 L | L3 | Rejected-Finance Rejected due to Bidder quoted higher rate |
| 4 | L4₹49.0 LRejected-Finance | ₹49.0 L | L4 | Rejected-Finance Rejected due to Bidder quoted higher rate |
| 5 | L5₹50.1 LRejected-Finance | ₹50.1 L | L5 | Rejected-Finance Rejected due to Bidder quoted higher rate |
| Sl No | Description | Qty | Unit | M/S L G BUILDERS L3 | M/S L.N. TRADERS L4 | M/S T G ENTERPRISES L6 | M/S TSERING DHONDUP L2 | SHELLUNG CONSTRUCTION L7 | M/S L N BUILDERS L8 | M/S YESHI THINLEY L1 | M/S ACE BUILDERS L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. | 63 | Cum | 515.1 ₹32,451.30 | 530.55 ₹33,424.84 | 549.02 ₹34,588.02 | 510 ₹32,130 | 557.25 ₹35,106.84 | 572.85 ₹36,089.84 | 500 ₹31,500 | 551.78 ₹34,761.83 |
| 2.00 | Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. | 19.5 | Cum | 199.98 ₹3,899.61 | 207.98 ₹4,055.59 | 216.38 ₹4,219.34 | 198 ₹3,861 | 225.03 ₹4,388.11 | 223.68 ₹4,361.78 | 200 ₹3,900 | 211.1 ₹4,116.43 |
| 3.00 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed. | 43 | Cum | 441.05 ₹18,964.94 | 436.63 ₹18,775.29 | 427.95 ₹18,401.66 | 445.5 ₹19,156.50 | 423.67 ₹18,217.64 | 436.38 ₹18,764.17 | 450 ₹19,350 | 432.27 ₹18,587.53 |
| 4.00 | Dismantling of post or struts ( wood ,steel, RCC) any section including taking out embedded portion and making good disturbed surface.complete all as specified and directed by Engr-in-Charge. | 200 | RM | 52.82 ₹10,564.40 | 51.77 ₹10,353.11 | 49.72 ₹9,943.13 | 53.9 ₹10,780 | 48.72 ₹9,744.27 | 49.7 ₹9,939.15 | 55 ₹11,000 | 50.73 ₹10,146.05 |
| 5.00 | Taking down chowkets or frame with shutter (without taking off shutters from the frame) n.exe 1.5 sqm each. | 18 | Each | 438.2 ₹7,887.67 | 464.5 ₹8,360.93 | 521.91 ₹9,394.34 | 413.4 ₹7,441.20 | 553.22 ₹9,958 | 575.35 ₹10,356.32 | 390 ₹7,020 | 492.37 ₹8,862.59 |
| 6.00 | Taking down chowkhats or frame exc 1.5 sqmtr but n.exc 4 sq m(without taking off shutters from frames), complete all as specified and directed. | 8 | Each | 521.33 ₹4,170.65 | 542.18 ₹4,337.48 | 586.43 ₹4,691.41 | 501.28 ₹4,010.24 | 609.88 ₹4,879.07 | 646.48 ₹5,171.81 | 482 ₹3,856 | 563.87 ₹4,510.97 |
| 7.00 | Demolition of stone, brick/PCC block masonry work built in cement mortar complete all as directed. | 28.14 | Cum | 1,560.6 ₹43,915.28 | 1,591.81 ₹44,793.59 | 1,656.12 ₹46,603.25 | 1,530 ₹43,054.20 | 1,689.24 ₹47,535.32 | 1,706.14 ₹48,010.67 | 1,500 ₹42,210 | 1,623.65 ₹45,689.46 |
| 8.00 | Dismantling stone slabs and tiles laid bedded and pointed in any mortar of anydescription or thickness in floors, aprons etc. | 12.71 | Xsqm | 957.87 ₹12,173.62 | 967.45 ₹12,295.36 | 986.9 ₹12,542.49 | 948.39 ₹12,053.09 | 996.77 ₹12,667.92 | 1,066.54 ₹13,554.67 | 939 ₹11,933.75 | 977.13 ₹12,418.31 |
| 9.00 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed. | 12.66 | Cum | 1,411.35 ₹17,867.69 | 1,369.01 ₹17,331.66 | 1,288.1 ₹16,307.36 | 1,455 ₹18,420.30 | 1,249.46 ₹15,818.14 | 1,230.72 ₹15,580.87 | 1,500 ₹18,990 | 1,327.94 ₹16,811.71 |
| 10.00 | Dismantaling timber scantling 40 Sq cm as in unframed work and over in sec in any position | 1.42 | Cum | 1,056.44 ₹1,500.14 | 1,035.31 ₹1,470.14 | 994.31 ₹1,411.92 | 1,078 ₹1,530.76 | 974.43 ₹1,383.69 | 1,023.15 ₹1,452.87 | 1,100 ₹1,562 | 1,014.6 ₹1,440.74 |
Tender Value
₹45.3 L
EMD Value
₹91,000
Closing Date
20 Dec 2025, 6:00 pmClosed
Maj Rohit Gogoi
GE 859 EWS
ADDN ALTN OF 02 SINGLE OR LIVING ACCN AT 268 TRANSIT CAMP AND SPL REP OF BLDG NO TWG 360 OR LINE AT 384 ASC COY SUP UNDER GE 859 EWS
2025_MES_742074_1
8973/E8
Open Tender
Civil Works
Tawang
ADDN ALTN OF 02 SINGLE OR LIVING ACCN AT 268 TRANSIT CAMP AND SPL REP OF BLDG NO TWG 360 OR LINE AT 384 ASC COY SUP UNDER GE 859 EWS
7 documents required · 7 mandatory
₹500
Yes
GE 859 EWS
₹91,000
Yes
8 Apr 2026
29 Nov 2025
22 Dec 2025
29 Nov 2025
20 Dec 2025
13 Dec 2025
Excavating in trenches not exc 1.5m wide and n.exc 1.5 m in depth, for foundations, etc, or for shafts, wells, cesspits, manholes, pier holes, etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning filling in with approved excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
Dismantling of post or struts ( wood ,steel, RCC) any section including taking out embedded portion and making good disturbed surface.complete all as specified and directed by Engr-in-Charge.
Taking down chowkets or frame with shutter (without taking off shutters from the frame) n.exe 1.5 sqm each.
Taking down chowkhats or frame exc 1.5 sqmtr but n.exc 4 sq m(without taking off shutters from frames), complete all as specified and directed.
Demolition of stone, brick/PCC block masonry work built in cement mortar complete all as directed.
Dismantling stone slabs and tiles laid bedded and pointed in any mortar of anydescription or thickness in floors, aprons etc.
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) complete all as directed.
Dismantaling timber scantling 40 Sq cm as in unframed work and over in sec in any position
Dismantling wooden fillets, rails, posts, rafters,purlins, etc. under 40 sq. cm in section
Dismantling of wall and celling boards (fibre, pulp, insulation, etc) or insulation board/slabs/blankets. in any thickness incl cover fillets with nails.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified.
Dismantling plain or corrugated steel sheeting any thickness, complete all as specified and directed.
M&L for broken stone or boulder hardcore of gauge n exe 63mm deposited, spread and levelled in layers n exe 15cm thick, watered and rammed to a true surface.
Providing precast cement concrete solid building blocks or slabs 10cm thick (with plainor interlocking joints as directed) setting in mortar,complete, in walls type B1 1:2:4 (20mm graded aggregate) set in CM (1:6)
M&L for reinforced cement concrete (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc; basement slabs under reamed pillars and mass concrete complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately)
M&L for reinforced cement concrete (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately)
M&L for reinforced cement concrete (1:2:4) type B1 (nominal mix) using 20 mm graded stone aggregate as in column, pillars, piers, post and struts complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately)
M&L Cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L forPCC type B1, 1:2:4 (20mm graded agg) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones bed plastes,, kerbs not provided for in item No 4028 , water troughts and the like rounded or chamfered angles and throating complete all as specified and directed.
M&L for Pre-cast cement concrete 1:3:6 type C1 usnig 20mm graded crushed stone aggregate block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
M&L for Walling of random rubble uncoursed, well bonded bedded and solidly hearted built in CM 1:6 (below ground level) complete all as specified as directed.
M&L for formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beam; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to faces of sides and soffits of floor or roof beams, cantilevers, shelves including supports, overhangs, etc for rough finished flat surfaces of concrete complete all as specified and directed
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished square, rectangular or polygonal surfaces of concrete complete all as specified and directed
M&L for second class hard wood plain fillets, square, rectangular or triangular in section, wrought secured with nails of sectional area exc 3 Sqcm and n.exc 6 Sqcm
S&F Second class hard wood plain, solid, straight chowkhats and frame, wrought, framed rebated on the soild, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed
S&F 30mm thick 2nd class hard wood glazed and skelton window/door open rebated and prepaid to receive glass gauze etc, divided into squares (with sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR part-I, sec 8 clause 8.24 (a) all as specified and directed.
S/F 30 mm thick flush shutters,solid core construction with block board core and plywood face panel, commercial type on both sides, complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts 125 mm of extruded section and fixed
S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed
S&F 75 mm long butt hinges medium grade cold rollled mild steel and fixed
S&F 100 mm long aluminium handles cast type anodised
TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
TMT bars 8 to 10 mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastening (Beam, tee, angle, channel or flat sections) icluding distance pieces, cleats etc, complete all as specified & directed Fe-410w,(Gde-E-250) qtly
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specified.
M&L for 75 mm thick 1:3:6 type C2 ( using 40 mm graded stone aggregate) as plinth protection./paving/footpath.
M&L for 40mm thick PCC type B-1, 1:2:4 (20mm graded aggregate) as in floor, complete all as specified and directed.
M&L 3mm thick ordinary glass, pin head type and glazing with oil puty in square n exc 0.5 sqm in each pane, complete all as specified and directed.
Supply and Fix 4mm thick Plywood, grade BWR, type BB, fixed with nails to timber framework as in ceiling etc complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C2 40mm graded aggregate as in plinth protection/paving/footpath, flooring,finished even and smooth without using extra cement complete all as specified and directed.
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/ rectangular ) area of each tiles , exceeding 0.11 sqm but not exceeding 0.18 sqm ,in floor etc set and jointed inneat cement slurry and pointed inwhite or coloured cement to match and incuding 15 mm thick screed bed or bedding layer in CM 1: 6 complete all as specified and directed .
M&L for rendering 15 mm thick plaster on fair faces of brick/concrete surfaces in CM (1:4) on wall surface, finished even and smooth without using extra cement.
M&L for rendering 15 mm thick plaster on fair faces of brick/concrete surfaces in CM (1:6) on wall surface, finished even and smooth without using extra cement.
M&L for preparation of new plastered surfaces of wall and applying two coat of cement base paint complete all as specified and directed
M&L for preparation of new plastered/concrete surfaces of walls and applying two coats of oil bound distemper over one coat of primer, over 1mm thick birla white putty ( where as required ) white or tinted including necessary scaffolding etc complete all as specified and directed.
Supply only Integral water proofing compuond, complete all as specified and directed
S&F 200mm aluminium anodised tower bolts of extruded section fixed with screw, complete all as specified & directed.
S&F Mild steel work as in window guard bars complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for 3mm thick cover fillets of standard hard board 40mm wide fixing with screws complete all as specified and as directed
M&L for 4mm thick plywood, (3 Nos of ply) grade BWR, type BB, fixed with screws to timber framework in ceiling
M&L Machine cut kota stone slab flooring 20-25mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete in CM (1:6) screed bed or bedding layer of mortar 20mm thick for laying floor finishes complete all as directed.
M&L for prep of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed complete.
M&L for prep of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed complete all as specified and as directed
M&L for two coats of synthetic enamel paint over a coat of pink primer including prepration to new wooden surfaces exc.10cm in width or girth complete all as specified and directed.
M&L for preparation of new or preciously untreated steel surfaces of any description, not otherwise described over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide , zinc crome complete all as specified and directed.
M&L for preparation of new or preciously untreated steel surfaces of any description, not exc 10cm width or girth, when unconnected wiith other painting or when painted in a different tint and applying two coats of synthetic enamel paint over a coat of red oxide , zinc crome complete all as specified and directed.
M&L Second class hard wood clean swan timber framed work and fixed as in scantling.
S&F 30mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass,gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats
S/F 30 mm thick 2nd class hardwood plain framed panelled shutter (any number of pabels) with panels of timber flat on both sides (feather edged) or of veneered particle board medium density, wood particle board with commercial face veneers fitted to chowkats, , complete all as specified and directed.
Supply and fix Aluminium anodized barrel tower bolts of extruded section, 100 mm long, complete all as specified and directed.
Supply and fix mild steel butt hinges, medium weight, cold rolled 100 mm size , complete all as specified and directed.
Supply and fix Aluminium handles, cast type, anodized, 150 mm size , complete all as specified and directed.
S&F in rep GI wire cloth 0.56mm nominal dia wire and average width of aperture 1.18 mm and fixed with screws or GI staples complete.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete and making good disturbed surfaces of walls, floors, etc. all as directed.including taking down fittings such as switches, ceiling roses, regulators, sockets,lamp holders, ceiling fittings, bulk head fittings, tube light fittings etc
M/L for point wiring in casing capping with 1.5sq mm FRLS PVC insulated unsheathed single core multithreaded copper conductor cable 1100 volts grade incl 1.5 Sq mm PVC insulated unsheathed copper conductor cable as earth continuity conductor drown through in and incl casing capping with its accessories and PVC Boxes for fixing switches/sockets etc for the following.
All as per above item No-2 but One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size.
S&F Switch piano, flush type single pole, one way 5 Amp.
S&F Switch socket combination 2 in 1, 5 A flush type.
S&F ceiling rose surface bakelite 65mmx50mm 100watt three terminal.
S&F DWC Pipe 63/50mm size all as specified and directed by Engr-in-Charge.
All as per above item No-2 but One socket outlet 5/3 pin 6 AMPS controlled by one switch on independent board.
All as per item No 2 above but 3 pin socket out let 15/16 Amps on the independent Board all as spfd with single core unsheathed PVC insulated cable multistranded copper conductor of size 2.5 sq mm for phase & neutral & 2.5 sq mm
for earth continuity conductor.
S&F in replacement of LED Bulb 9 watt cat part no LED PLUS 9W B22 WW 2 STAR LAMP complete all as specified and as directed by engineer-in-charge.
S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 50 mm bore.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4.0 Core including taking down old one.
S&F in replacement of sheet metal enclosure distribution box 4 way TPN 415 volts with suitable size of rated bus bar double door complete including connecting up all as specified .
Supply and fixing in replacement of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing in replacement of LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
M & L in replacement of Lamp holder, PVC/Polycarbonate type with back plate suitable for battern fittings complete. all as specified and directed by as engineer-in-charge.
M & L Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type Universal.
Supply and fixing in replacement of MCB SP 5-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing in replacement of MCB SPN amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.
Supply and fixing in replacement of 415V 10KA 'C' curve miniature circuit breaker TPN 40 To 100 AMP poles and current carrying capacity in the DB complete with connection testing and commissioning all as directed and as specified.
Supply and laying or fixing or passing through pipeXLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 35 sqmm 3.5 core complete including taking out old unserviceable cable all as specified and directed by Engineer in charge.
S&F sheet metal enclosure double door for MCB DB single pole and neutral 8 way with 200 Amps rated bus bar 240 volts double door (Metallic) type including taking down old unserviceable MCB DB with MCBs.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground( earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in electrical plate No 3 of SSR Pt I including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC ( 1:2:4) type B-1 cover slab framed with 50X30X4 mm MS angle (reinforced with 6 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar) including providing charcoal or coke and magnesium sulphate in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect., GI earth wire protected by 40 mm bore (light grade) galvanized iron pipe and other end connected to the earth bar (test point) made of MS flat (400X32X6 mm) bend in ‘D’ shape and fixed to wall by means of fast nut or bolt grouted in to wall at 1 mtr from plinth height. 4sqmm PVC insulated (colour green) copper conductor single run as earth continuity conductor along with 15 mm PVC conduit grouted in wall or fixed on wall surface to be continued up to main switch board and fix with common earth dolly as directed by EIC . Disposal of soil to a distance not exceeding 50 mtr and necessary testing on completion complete including taking out old unserviceable earthing materials all as specified and as directed.
stage.html
html • 0.06 MB
technical_830968.pdf
techsummary_830968.pdf
finance_830968.pdf
BOQ Comparative Chart
xlsx
finsummary_830968.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TENDER8973.pdf
Tender Documents • 1.29 MB
BOQ_830968.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid