Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.0 CrAccepted-AOC | ₹6.0 Cr | 1 | Accepted-AOC Accept |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technical Bid Not Qualified |
| Sl No | Description | Qty | Unit | N RAJENDIRAN L1 |
|---|---|---|---|---|
| 1.00 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and M-Sand, silt or other loose soil, wet Sand,or silt not under water, light black cotton soil, Sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum | - | - | - |
| 1.10 | a) Footing | 2,471 | Cum | 246.5 ₹6,09,101.5 Lowest |
| 1.20 | b) Grade Beam | 776 | Cum | 102.5 ₹79,540 Lowest |
| 2.00 | Supplying and filling in foundation and basement with Stone Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification. | 182 | Cum | 545.5 ₹99,281 Lowest |
| 3.00 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification | 260.71 | cum | 5,700 ₹14,86,047 Lowest |
| 4.00 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) | 1,419 | Sqm | 494 ₹7,00,986 Lowest |
| 5.00 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) | - | - | - |
| 5.10 | For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. | 809 | Sqm | 1,227.5 ₹9,93,047.5 Lowest |
| 5.20 | For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. | 1,296.92 | Sqm | 1,023 ₹13,26,749.16 Lowest |
| 5.30 | Vertical Shuttering | 2,571 | Sqm | 505.8 ₹13,00,411.8 Lowest |
Tender Value
₹7.3 Cr
EMD Value
₹7.3 L
Closing Date
6 Aug 2025, 3:00 pmClosed
EXECUTIVE OFFICER GUMMIDIPOONDI TOWN PANCHAYAT
1 METTU STREET EXECUTIVE OFFICER GUMMIDIPOONDI TOWN PANCHAYAT
Construction of New Bus Stand GNT Road SF No.173/1A1 in Pethikuppam Village Gummidipoondi Taluk
2025_DTP_584310_1
41/2025/A1
Open Tender
Civil Works
Works
90 days
KNMT FUND 2025-2026 New Bus Stand
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹7.3 L
Yes
16 Sept 2025
22 Jul 2025
6 Aug 2025
22 Jul 2025
6 Aug 2025
22 Jul 2025
Amount
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and M-Sand, silt or other loose soil, wet Sand,or silt not under water, light black cotton soil, Sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
a) Footing
b) Grade Beam
Supplying and filling in foundation and basement with Stone Dust in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
Vertical Shuttering
M-25 CONCRETE - Providing and laying in position, standarised design mix M-25 Grade using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350Kg/m3 and maximum water cement ratio of 0.55, including admixture(plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.70 cu.m.)940.50Kg of 20mm machine crushed stone jelly and with about (2.80 cu.m.)462.00Kg of 10-12mm machine crushed jelly and with about (4.25 cu.m.)701.25Kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever neccessary without clambing extra, etc. complete complying with standard specification and as directed by the departmental officers. the coarse and fine aggregates to be used should comply with the requierments of IS 383-2016. (No separate payment will be made by the department for the exces usage of materials as per design mix.)
Basement
Ground Floor
Providing and laying in position Standardised Concrete Mix M-30 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 400Kg/ cum and maximum water cement ratio of 0.45 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone sand (M- Sand) but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards.
Basement
Ground Floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification.
Basement
Ground floor
First Floor
Brick partition walls of 10.80cm thickness using II class table moulded bricks 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Sand ) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
Ground floor
Supplying and filling in foundation and basement withGood earth filling in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Special celing Plastering with cement mortar (1:3) 10mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309 Coloumn Plastering
Painting two coats with ready mixed Interior Plastic Emulsion Paint approved quality and colour with Primer for Plastic Emulsion Paint, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m S.No 358
Paving the floor with Vitrified Marbonite tiles of stain free nano polish approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three M-Sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Supplying and laying in flooring with fully polished Sinthetic Grey colour Granite stone of 20mm thick (average) of 4' X 2' in size laid over base layer of cementmortar 1:3 (one cement and three Plastering sand) - 20 mm thick and applying cement slurry &pointed with white cement and colour pigments to the colour of stones and polished neatly as directed by the deparmental officers
Paving the floor with design antiskirt ceramic tiles (colour and shade as directed) of size 305mm x 305 mm x 6mm in all floor aver a base layer of cement mortar 1:3 (one cement and three sand) 20 mm thick laid in situ and pointed with same coloured cement.
Dadooing walls with Glazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two M-Sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab, the proportion of brick jelly to lime being '32 to 12.5 well boated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete.-10 cum
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., co
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work
Supply and fixing of PVC Solid Doors using 19gauge 19mm MS Sq,tubes for styles and frames, 15mm MS Sq.tubes for to, Lock and bottom rails. The Steel Tubes shall be covered with 5mm thick Solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including furniture and fittings. The over all size of styles shall be 50mm X 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm X 30mm. The over all size of frames shall be 50mm X 45mm with suitable tabate for housing the shutter etc, complete as per standard specification.
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc.. ROLLING SHUTTERS (WITH ISI MONOGRAM) (PWD SOR M-0401)
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Supply and Installation of Single Glass partitionas partition with 45mm x 25mm with minimum 1.5 -2mm thickness Polished Aluminium partition systems using snap on option for installing 10mm Toughened glass from FFL to max 2400 mm. Only glass surface shall be measured and paid for this item. Aluminium profile frams to be used for all joints. Make of Partition Frames – Alloy / Hysis / Wall line or Equ. Make of Glass – Saint Gobain/Equ. (Quotation)
Earthling as per ISI Specification with an earth electrode of 2.1mt class 'B' GI pipe of Dia not less than 40mm and with 20mm Dia copper earth flat of size 125mm x50mmx6mm, with funnelling arrangement using charcoal, common salt, G.I.reducer, check nuts etc., and masonry workhand providing RCC cover slab 38mm thick for the Brick masonry including cost of steel and fabrication of reinforcement etc., complete in all respects as directed by the departmental officers. (SD 212)
Supply and run of 25 mm x 3 mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection. SD 72
Supplying and run off 8 SWG copper wire on walls or below ground level with necessary 'U' nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 370)
Supply and fixing of 7 segment 8 way 63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming MCB / Isolator and another separate 4 way provision for accommodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and separate provision for MCB / Isolators ( totally 24 nos.) for sub incomers in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. with the following in flush with wall with earth connection only.- SD 629
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for 5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38
Supply and run off 2 of 2.50sqm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continuous earth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departmental officers. (derived from SD 55)
Supply and run off 2 of 1.5 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 337)
Supplying and fixing 12" (30cm dia) light duty Exhaust fan including cost of all materials, labour, lead, lift, etc complete SD 114
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic regulator with 300mm down rod on the existing clamp (SD111)
supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. SD 441
Supply and fixng of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2feet using angle iron of size 1-1/2"x1-1/2"x1/4" rigidly fixed on wall covered with hylem sheet of size 2feet x 1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos. 63A fuse units (500V), 1No. neutra llink, copper earth flat of size 1"x1/4"with interconnection of EB meter to fuse units by 16Sq.mm PVC insulated copper wire with 1No 63Amp 30MA Four Pole RCD / RCCB (Higher End) with suitable necessary connection with earth connection complete SD 131)
Supply and Run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour. SD 359
Supply and Run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion with suitable colour. SD 357
Supply of 15 lpmx 125 m Head wet type 1 phase bore well submersible motor with pump set with out panel boards as per IS 8034 including cost of tranportation of materials etc,complete as per standared specification.
Supply and erection of 1 phases panel Board etc. complete as per standared specification.
Supply of 2.50 Sq.mm PVC insulated and sheathed 3 core flat type copper cable conforming to IS 694/1990 including all cost and conveyance of all materials etc complete. as per standard specifications.
Supply and fixing of 32Amps DP switch of 500V with metel clad with fuse and neutral (side Handle) on suitable TW Board with earth connection only.
Wiring with 2x2.5 sq. mm PVC unsheathed SC alu. Cable of 650V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with T.W.switch box with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for
Supply fixing of Power capacitor for Power factor improvement with oil filled with discharge resistence 3 phase 415 / 440 volt HZ conforming to ISS 2384 with ISI marking.
Supply and run of 2 of 4 sq.mm PVC insulated SC unsheathed CU.Conductor of 1100 V in 25 mm dia GI Pipe (Glass - B) suitably bent at ends with neccessory angle iron upright and end supports for mains.
Supply and run of 2 x 4 sq.mm PVC insulated SC unsheathed CU.Conductor of 1100 V on 7/20 GI bearer wire for Service Connection Mains.
Supply and fixing of single phase 15 Amps aerial fuse unit (500v) on suitable 100mm x 100mm TW concealed box with hylam sheet on the tapping pole with necessary clamps.
Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth ,valves erection clamps,pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter,Ammeter, three pilot(indicating)lamps capacitor single phasing preventor, water level guard and laying and jointing the caple and twin earthing as per IE rules extra complete and testing the pumpset and trail run for ten days.
Providing & fixing PVC RAIN WATER DOWN FALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes, Bemds, other clamps, screws nails etc., complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm](D)
Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitary fittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications.(D)
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading,unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc.,
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
25mm Gun metal Gate Valve
32mm Gun metal Gate Valve
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
SD Tap
Pillar Tap
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
25mm dia
32mm dia
Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements
Coupler
25mm Pipe
32mm Pipe
Elbow
25mm Pipe
32mm Pipe
25mm Pipe
32mm Pipe
25mm Pipe
32mm Pipe
End Cap
25mm Pipe
32mm Pipe
Reducer
25 mm x 20 mm
32 mm x 25 mm
Reducer Tee
25 mm x 20 mm
32 mm x 25 mm
Reducer Elbow
25 mm x 20 mm
32 mm x 25 mm
Jet Nipple
25mm Pipe
32mm Pipe
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthenware wash hand basin of size 550 x 400mm (with pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylon connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position C.P. Towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plug and C.P. Screws etc. complete complying with standard specification.
Supplying and fixing in position Indian make bewelled edge mirror of size 600 x 450mm quality including cost of Rawal plugs, brass screws. etc. complying with standard specification.
Supplying and fixing in position Indian Water Closet (Oriya type) of size 580 x 440mm White/Color glazed earthen ware of approved quality and brand with "P" or "S" trap conforming to BIS with Sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings.....
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Providing rain water harvesting using 3 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia to a depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects.
Investigation charges for Geophysical survey point.
Drilling of 6"Dia (150mm) vertical bore in any overburden soil and hard rock area to the required depth as may be directed by the departmental offiers / Hydrogeologist including drilling charges, cost of transportation of the rig and other supporting vechicles from one place to another place including cost of fuel charges and labour charges required and incidental charges for preliminary arrangements etc. complete as directed by the departmental officers.
Supply and erection of 150 CS PVC casing pipe as per IS 12818/2010 including cost and conveyance of pipe and labour charges for errecting in position, cutting threading and welding if necessary etc. complete as directed by the departmental officers
Supply and fixing of 32mm Heavy duty UPVC Pipe theraded pipe of approved quality including cost and conveyance etc., complete
Supplyof 32 mm GI pipe of B class of approved quality including all cost and conveyance etc, complete, as per standerd specifiacation.
Supply and fixing of G.I. pipes and Water supply specials etc., complete as per standard specification.
32mm Bore clamp
Bore Cover Plate
32mm GI Elbow
32mm GI Union
32mm NRV (brass)
32mm Gate valve
32mm GI coupling
32mm GI Adopter
32mm GI Tee
32 mm GI Nipple - 300mm
32mm GI Bend
20mm GI Bend
20mm GI Tee
20mm GI Elbow
20mm GI Nipple - 300mm
20mm GI Nipple - 150mm
Steel Push 50 x 32 mm
Ball valve
32mm CI flange set
32mm GI Dummy
32mm dia GI cutting
32mm dia GI pipe Threading
Laying and jointing of 32mm GI pipe in proper gradient and alignment inculding all labour charges cost and conveyance of all material to site etc complete
Providing and laying spreading and compacting graded stone aggregate to wet mix macadam (WMM) including premixing materikal in mix plant carriage to mixed material by tipper to site laying in uniform layers withpaver in sub base course well prepared surface and compacting with vibratory roller to acheive the desired complete as per clause 406 of MORTH specifiaction.
Supplying and laying Precast Designer Paver Block confirming to IS 1568-2006 specification manufacturing and laying standard of M40 grade 83mm thick (table clauses 5 and 9.14) suitable for bus terminals ,industrial complexes, road on expensive soils etc., including the cost of paver block of size 225mm x 12.50 mm x 83mm and conveyance of materials to work site mentioned in the tender schedule cost of loading and unloading handling during over Stone dust of 100mm thick (excluding the cost of M- Sand) conveyance paver block cutter to site and hire charges of vibrators and block cutter operator and labour for leveling the M- Sand to paver block etc., complete ISI 15658-2006.
Manufacturing, supplying and fixing in position plain cement concrete precast kerb slab of size 600mm x 600mm x 100mm in Cement Concrete 1:1.5:3 (One cement, Two M - sand and Four jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of slab etc., complete complying with standard specification and as directed
Providing of Granular Sub base using Grade I materials of table 400 -1 of Morth with minimum CBR 30 spreading in uniform layers with motor grader on prepared surface, mix in by palce method at OMC and compacting with Vibratory Roller to achieve the desired density including all labourcharges etc, complete as per technical specification and as directed by the departmental officers. Morth - Rev V No. 111,112,401,900
Providing and laying 50 mm compacted thick dense bituminous macadam using 0.24 cum of 26.5-13.2 mm graded metal and 0.25 cum of 13.2-2.36 mm graded metal and 0.23 cum of 2.36 mm & below metal with 53.20 kgs of 60/70 bitumen for premixing per 10 sqm including cost and conveyance of all materials to C M P site, heating the bitumen and agregates to required temperature and mixing them in required temperature in central hot mix plant 20- 30 tonnes capacity conveying the mix by tipper trucks to paver site,spreading the mix in required temperature for uniform thickness of 50mm with mechanical paver to the specified grades and cross sections and compaction by Vibratory roller to the required density etc.,including labour charges for loading bitumen in to bitumen tank and metal to feeder unit,labour for attending to paver site etc., including hire charges and fuel charges for 20-30t C M P with bitumen boiler,tipper trucks, paver finisher, vibratory rollers and all other tools and plants required,including all other incidental charges etc.,complete using C M P clause 505 of MORTH Rev-5 specifications.
Providing and laying Prime coat of 7 kgs/10 sqm over the WMM surface treated with primer using 7 kgs of bituminous Emulsion (SS) for 10square meter area including cost of bituminous binder, including labour charges for applying the required quantity of bituminous binder as Prime coat manually etc., complete as per 502 of MORTH Rev-5 Specifications
Providing and laying tack coat of 2.5 kgs/10 sqm over the WMM surface treated with binder using 2.5 kgs of bituminous Emulsion (RS) for 10square meter area including cost of bituminous binder, including labour charges for applying the required quantity of bituminous binder as tack coat manually etc., complete as per 503 of MORTH Rev-5 Specifications
Providing and laying Bituminous concrete to 30mm / 40mm thick using 0.13 cum of 19.00-9.50 mm graded metal and 0.17 cum of 9.50-2.36 mm graded metal and 0.26 cum of 2.36 mm & below metal with 45.27 kgs of 60/70 bitumen & 5.03Kg of Plastic waste (Total-50.30 kg) and for premixing per 10 sqm including cost and conveyance of all materials to C M P site, heating the bitumen and agregates to required temperature and mixing them in required temperature in central hot mix plant 20- 30 tonnes capacity conveying the mix by tipper trucks to paver site, spreading the mix in required temperature for uniform thickness of 40mm / 30mm with mechanical paver to the specified grades and cross sections and compaction by Vibratory roller to the required density etc., including labour charges for loading bitumen in to bitumen tank and metal to feeder unit,labour for attending to paver site etc., including hire charges and fuel charges for 20-30t C M P with bitumen boiler,tipper trucks, paver finisher, Vibratory rollers and all other tools and plants required,including all other incidental charges etc.,complete using C M P clause 507 of MORTH Rev-5 specifications.
CCTV Facility
ARMOURED LAN & CCTV CABLE CAT 6 (PWD SOR pg 222)
Supply and laying of OFC Cable
POE Switch for Camera -8 Port (PWD SOR pg no 222)
Hard Disk for NVR 6 TB (PWD SOR pg no 223)
Network Video record for CCTV 8 Channel-1 SATA 1 No hard disk (PWD SOR pr 222)
CCTV Camera
Rack with Accessories 6 U rack (PWD SOR page no 224)
I/O socket RJ 45 (PWD SOR pg no 154)
I/O socket RJ 11 (PWD SOR pg no 154)
29" LED TV
Supply and fixing of water CO2 stored pressure type 9litres capapcity fire extinguishers as per new IS 15863 complete with control valve, gun meta cap, pressure guage, operation sticker, discharge hose, wall mounting bucket , safety clip, etc., as directed by departmental officers (SOR pg 127)
4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle (SOR Pg No142)
First Aid Box complete with all First Aid Medicines (SOR Pg No207)
Supply and fixing of 30W LED Outdoor street light fitting (Philips/Havells) complete.
Supplying and fixing GI Steel tubular pole for street light of 6 Meter length Single brakcet pole with base plate including cost of material, labour, lead, lift etc.,
Supply and run of 4 core 16 Sq.mm PVC Armoured cable of 1100 V grade with ISI mark.(SD 181)
4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of outgoings ways - 12 PWD SOR Pg.no.199
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with doubledoor (metal) 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall andmaking good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISImark (like standard make) (SD514)
Highmast (16 Metre) with 8 Nos. 150W LED Fitting
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
NIT.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .