Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC GATE NO 454 01 TAPKIR NAGAR PUNE NASIK HIGHWAY NEAR GANDHARV NAGARI MOSHI PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹30.2 L+₹73,410 (2.49%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹36.3 L+₹6.8 L (23.1%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
8 Nov 2023, 6:00 pmClosed
CWE KHADKI
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR/RE-WIRING AND REPLACEMENT OF INTERNAL WIRING FITTING AND FIXTURES, FLAME PROOF LIGHT, CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN AND GEYSERS FOR CQA(A), PTL, SQAE AND NAI UNDER AGE E/M -II IN GE (CENTRAL) KHADKI
2023_MES_622713_1
CWE/KKE/TOKEN-25 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KHADKI
AS PER TENDER
6 documents required · 6 mandatory
₹1,000
Yes
GE CENTRAL KHADKI
₹90,000
Yes
22 Jan 2024
11 Oct 2023
16 Nov 2023
11 Oct 2023
8 Nov 2023
26 Oct 2023
12 Oct 2023 - 18 Oct 2023
Amount
Taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing material to store for keeping in safe custody or for taking credit ( credit for above items should be made as per condition seperately) and making good disturbed surface of walls, floors etc complete all as per the existing finish.
M&L for point wiring for point wiring for light/fan/exhaust fan point controlled by one switch in casing & caping of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge .
All as per Srl item No 2 above but point wiring for bell/buzzer point controlled by one bell push.
All as per Srl item No 2 above but point wiring for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per Srl item No 2 above but point wiring for 5 pin switch socket outlet 5 Amps on same board controlled by one switch.
M&L for point wiring for light/fan/exhaust fan point controlled by one switch in PVC conduit of suitable size but not less than 20mm including all fittings such as elbow, bends, junction boxes, saddles, etc. on surface with and including ISI marked two runs of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 sqmm nominal cross sectional area, 1100 volts grade and including one run of 1.5 sqmm (green colour) ISI marked PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire to be terminated in and incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover for one light point or one fan point controlled by one switch including making good the disturbed wall and painting the same with matching to existing wall all as specified and directed by Engineer in charge.
All as per Srl item No 6 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per Srl item No 6 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch.
M&L for point wiring for one light/ fan/ bell point controlled by one switch in steel conduit with all steel enamelled fittings such as elbow bends, junction boxes, supporting clamps for proper hanging arragements made out from 20x1mm flat aluminium patti including nuts, bolts and bending to shape etc. of appropriate size but not less than 20mm on surface with two run of PVC insulated unsheathed multistranded copper conductor cable (FRLSH) 1.5 Sqmm nominal cross sectional area 1100 volts grade and including one run of 1.5 sqmm (green colour) PVC insulated unsheathed multistranded (FRLSH) copper conductor cable as earth wire incl. suitable size sunken type Galvanised pressed sheet steel 1.6 mm thick terminal box of suitable size with 3 mm thick laminated hylum sheet for mounting switches, sockets etc. and making good the disturbed wall and painting the same with matching colour of the existing wall, for light/fan/exhaust fan point controlled by one switch complete all as specified and directed by Engr-in-Charge
All as per Srl item No 9 above but 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per Srl item No 9 above but 5 pin switch socket outlet 5 Amps on same board controlled by one switch.
M&L for point wiring for point wiring for light/fan/exhaust fan point controlled by one switch complete with 1.5 sq.mm single core PVC insulated, unsheathed multistranded copper conductor FRLSH cable 1100 Volts grade drawn through and including DLP mini trunking but shall be increased as per actual site requirement , ISI marked including accessories like bends, tees, junction boxes fixed concealed/ recessed in wall or ceiling including 1.5 sq.mm PVC insulated but unsheathed multistranded copper conductor FRLSH cable as earth continuity wire including modular metal flush box with white/coloured top cover plate and frame of required modules for mounting of modular switches, sockets,bell push and fan regulators complete including dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and as directed.
All as per Srl item No 12 above but point wiring for 5 pin switch socket outlet 5 Amps on independent board controlled by one switch.
All as per Srl item No 12 above but point wiring for 5 pin switch socket outlet 5 Amps on same board controlled by one switch.
M&L for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch point wiring complete as specified with 1100 V grade 4 Sqmm single core PVC insulated unsheathed multistranded copper conductor cable FR grade, conforming to relevant IS drawn through and including PVC casing and caping with all accessories fixed on surfaces of wall, ceiling, incl PVC rectangular block of suitable size for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover including 4 Sqmm single core PVC insulated and unsheathed copper conductor cable FR grade as earth continuity wire connected to common earth and earth dolly including testing complete all as specified and directed by Engr-in-Charge .
All as per Srl item No 15 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in steel conduit.
All as per Srl item No 15 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in PVC conduit.
All as per Srl item No 15 above but for for one 6 pin switch socket outlet 15 Amps/AC Point on independent board controlled by one switch in DLP Mini Trunking.
S&F for switch piano flush type single pole, one way 5 Amp.
S&F for switch flush type, 5 Amps, Bell push , flush type , 230 volts AC circuit complete all as specified & directed
S&F for switch socket combination 2 in 1, 5 pin, 5 Amp flush type universal.
S&F for switch socket combination 2 in 1, 3 pin, 5 & 15 Amp flush type universal.
S&F for ceiling rose PVC/polycarbonate, isolated body, three terminals, complete all as specified & directed .
S&F for in replacement Stepped type electronic fan regulator flush type suitable for ceiling fans, prewired 230 volts AC 50Hz supply 100Watt complete all as specified & directed.
S&F for bell Ding Dong AC, 230 volts, single pole.
Dismantling and Taking out old unserviceable copper/aluminium sub main wiring/Unarmoured cable (used as Sub main wiring) from any height of any Size and Core with all connecting accessories incld. conduit or casing caping and incld. making good to the disturbed wall and painting the same with matching paint as of existing wall including material all as specified and directed by Engineer in charge.
M&L for Sub main wiring at any height with 2 single core PVC insulated, multi stranded copper conductor cable (FRLSH), unsheathed, 2.5 sqmm, 1100 volt grade conforming to IS drawn through and including New 20 mm PVC conduit and including one single core PVC insulated multi stranded unsheathed copper conductor cable, 2.5 sqmm,, FRLSH green in colour as continuous earth wire including all accessories and fixing arrengements, supporting clamps, bends, sockets and connecting items etc. all as specified and directed.
All as per Srl item No 27 above but for casing & capping
Material and labour for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 4.0 Sqmm, 1100 volts grade, drawn through and including New PVC conduit 20 mm dia including connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 4.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
All as per Srl item No 29 above but for casing & capping
M&L for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type, 6.0 Sqmm, 1100 volts grade, drawn through and including including New PVC conduit 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type, 6.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
All as per Srl item No 31 above but for casing & capping
M&L for Sub main wiring at any height and surface with and including two single core PVC insulated multi stranded copper conductor cable, conforming to IS, FRLSH type,10.0 Sqmm, 1100 volts grade, drawn through and including including New PVC conduit 20 mm dia connected accessories and one single core PVC insulated multi stranded unsheathed copper conductor cable, FRLSH type,10.0 sqmm, 1100 Volts grade,,green in colour as earth contuinity wire all as specified and directed by Engineer in charge.
All as per Srl item No 33 above but for casing & capping
Dismantling and drawing out old unserviceable Sub Main Aluminium/copper wiring from Existing Steel/PVC Conduit of any size and any type from any height with all connecting accessaries (excluding conduit or casing caping) and making good the disturbed wall and painting the same with matching to existing wall including material all as specified and directed by Engineer in charge.
M&L Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 1.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 1.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed.
M&L Sub main wiring at any height including using two single core PVC insulated copper conductor cable (FRLSH) of size 2.5 sqmm 1100 volt grade conforming to IS drawn through existing Steel/ PVC conduit including 2.5 sqmm. PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed.
M&L for Sub main wiring at any height with four single core PVC insulated copper conductor cable (FRLSH) of size 6 sqmm 1100 volt grade conforming to IS drawn through Existing Steel / PVC conduit including two single core 6.0 sqmm PVC multi stranded copper conductor cable (FRLSH) green in colour for continuous earthing all as specified and directed. (Note for item No 36 to 38) - (a). Two/Four runs of wiring cable and One/two runs of earth continuity wire shall be measured as one length.
Disconnecting and taking down old distribution Box with MCB/fuse grip TPN/SPN DB 2 Way to 12 Way old type DB including taking out all cable connections of any description and in any position and making good the disturbed surface of walls, to match with the existing surfaces complete all as specified and directed by Engineer in charge.
S&F, connecting & testing of VTPN DB of 12 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damage like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed . Note : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 8 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed Note : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing of VTPN DB of 4 way suitable for MCCB up to 160A as a incomer & SP / TP MCB as a outgoings with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 36kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed of Make Legrand Cat.No. 5077 45 or equivalent in Schneider- Acti-9/ L&T-Exora. Note : MCCB , MCB will be measured and paid separately under relevant item of this schedule.
S&F, connecting & testing SPN DBs of 8 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed
S&F, connecting & testing SPN DBs of 12 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed.
S&F, connecting & testing SPN DBs of 4 way for using MCBs / MCB isolators suitable for single pole and neutral, with IP 43 -IK09 as conforming to IEC 61439-3 & made of high quality CRCA sheet shall have integrated door earthing system, shall have reversible door facility, ergonomic design with rounded corners to protect against damages like bending, peeling of paint hence preventing rusting. DB shall be with Insulated Busbar with withstand capacity of 10kA, shrouded neutral bar, Door earthing, corner Safe. wiresets, shrouded Neutral bar, earth bar & wire ties, all as specified & directed
S&F, Thermal magnetic adjustable MCCB 160 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and directed.
S&F, Thermal magnetic adjustable MCCB 100 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and directed.
S&F, Thermal magnetic adjustable MCCB 63 Amps 4 pole with breaking capacity 16 KA & shall be Ics=Icu 100%, complete all as specified and directed.
S&F MCB 40 to 63 Amps, TPN "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed.
S&F MCB 40 to 63 Amps, TP "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed..
S&F MCB 6 to 32 Amps, single pole and neutral, "C" curve 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly complete all as specified and directed.
S&F MCB 6 to 32 Amps, single pole, 10 kA breaking capacity with integrated label holder, sliding bottom clamp, color coded On/Off indication on dolly, complete all as specified and directed..
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven single phase including MCB 'C' series SP 20 Amps and supplied with neutral links complete all as specified and directed.
Supply, fixing, connecting and testing in replacement Industrial Earth Plug & socket with sheet metal enclosure of IP44 rating electric driven three phase including MCB 'C' series TP 20 Amps and supplied with neutral links complete all as specified and directed.
Dismantling and Taking down unserviceable any light fitting from any location/height after disconnecting of electrical connection complete including all connected accessories all as directed by Engr-in-Charge.
S&F, LED tube light fitting suitable for and including 1x20 W 4 feet long tube with polycarbonate diffuser complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F CRCA housing box LED Type luminiare suitable for and including 2x20 W 4 feet long complete including tube rod & connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, LED Inverter Batten suitable for and including 20 W 4 feet long tube with back up time of 3 hrs complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 36W 2X2 LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 36W 2X2 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 18W 1X1 LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 18W 1X1 LED Surface mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 12W LED Round recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 40W,1ft x 4 ft LED recessed mounting light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 1X16W, 4 ft LED Flame proof light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 1X18W,4 Feet LED Ceiling suspended light fitting complete including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size & all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 20W Single End LED Tube rod including connecting up in existing fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F, 20W Double End LED Tube rod including connecting up in existing normal/flameproof fitting & make batten functional complete with all accessories for fixing on steel trusses / false / normal ceiling all as specified & directed.
S&F lamp holder, PVC/Polycarbonate type with black plate suitable for batten fittings etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and testing complete all as directed by Engr-in-charge.
S&F LED 18W Bulb complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Taking down and servicing of ceiling fan 1200/1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt/ washer, rubber real bush, canopy and reassembling the fan complete and hanging on its original/ new position as directed by Engr-in-charge.Note: MS nut bolts with spilt pin, Ball bearing and Gun metal bush will be paid and measured seperately.
Supply only MS Nut bolts with split pin as per sample and as directed by Engineer-in-Charge.
Supply only Ball bearing suitable size of ceiling fan and exhaust-fan of any type and size .
Supply only gun metal bush suitable for ceiling fan and exhaust fan any type and size including removing old one. Note : Item No. 71 to 74 will be fixed under Item No 75
M&L opening the body cover of fan any type and make and cutting the existing worn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and backing complete including the soldering new lead of copper wire testing complete including transportation to work shop and back all as directed for Ceiling fans 1200/1400 mm sweep Note : a) Contractor have to make the arrangement for testing of Rewinded fan upto 24hrs at Complaint cell of AGE E/M-II (C) Kirkee and in case of failure to above said testing a penalty of Rs 200/- per fan is deducted from contractors due and rewinding of same once again is bonded. b) Fan should be return to MES yard after rewinding within 10 day from the date of issue otherwise a penalty of RS 10/- per day per fan is deducted from contractor due.
All as per Item No 75 but exhaust fan Upto 300 to 350mm sweep
All as per Item No 75 but Wall mounted fan 400mm sweep
M&L flexible wire of size 23/0.0076 for ceiling fan connection including taking down the old unserviceable wire complete all as specified & directed by Eng-in-charge.
M&L for Preparation of old painted surface of ceiling fan and applying one coat of synthetic enamel paint with spraying paint on machine including making MES number on body of the fan including taking down and refixing and connection and testing complete all as specified & directed by Engr-in- charge.
S&F in replacement fan capacitor 2.5 mfd 240 V AC supply.
All as per item No 80 above but 4 mfd.
S&F exhaust fan louvers suitable upto 300 mm inplace of taking out old one louvers/grills/jalli including necessary grouting nuts and bolts holding for louvers from outside of building.
S&F insulated enclosure 2 pole suitable for SPN MCB including taking out old one. Note : MCB shall be measured and paid separately.
S&F LED Driver for ffittings 10W/ 20W.
Taking down carefully storage type water heater (Geyser) after disconnecting inlet/outlet/vent pipes, electric/earth connections etc cleaning of the body inlet/outlet/vent pipes stop cocks non return valves etc leakage arresting of inner copper/steel tank by weilding/brazing etc reassembling the geyser by replacing gaskets worn out nuts washetrs etc refixing the same in position by replacing mounting bolts and nuts reconnecting all inlet/outlet/vent pipes electric/earth connections and carrying oout testing for proper functioning oall as directed by Engineer-in-Charge for geyser of capacity 25 Ltr capacity. Note : Non return valve stop cock, PVC/Copper connections cable glass wood thermostat etc shall be measured separately.
All as per Item No 85 but 50 ltr capacity
Supply and replace heating element of storage type water heater sof compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer-in-Charge of capacity ISI Marked for 1.5 Kilo Watt Capacity
All as per Item No 87 above but 2.0 Kilo watt capacity
S&F thermostat suitable for 25/50 litre capacity storage type water heater including removal of old unserviceable ones as directed by Engineer-in-Charge.
S&F non return valve (gun metal) of size 15mm including removal of old ones for suitable to 15mm bore
All as per Item No 90 above but suitable to 20mm bore
S&F fusible plug suitable for 25/50 litre capacity storage type water heater including provn of necessary GI fittings removal of existing valves.
S&F CPVC SDR 11 fittings union of size 16 mm dia bore including taking down old u/s GI union
S&F indicator lamp assembly complete for water heater (geyser) suitable to work on AC 230 V supply and to match the existing size any type including disconnecting and removal of old ones.
Preparation of old painted surface of 50/25 liters storage type water heater and applying two coats of white synthetic enamel paint of approved make as directed.
S&F of CPVC pipes of 16mm bore SDR 11 and plain CPVC SDR 11 fittings on wall/ ceilings or laying on floors complete all as Specified
All as per item no 96 as above but for 20 mm bore
S&F modular switch one way 6 Amp 1 module.
S&F modular white cover plate with frame ,3 module.
S&F modular white cover plate with frame ,6 module.
S&F modular white cover plate with frame ,8 module.
S&F metal flush box 3 module.
S&F metal flush box 6 module.
S&F metal flush box 8 module.
S&F modular switch one way 16 Amp 1 module.
S&F modular socket , 6 A -2/3 pin combined 2 module.
S&F modular socket , 15 A -2/3 pin combined 2 module.
S&F modular fan step regulator 120 W-2 module
S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with and including one single pole MCB 20 Amps, 240 Volts complete.
M&L for earthing complete with 17.2 mm Copper bonded Earthing rod including Short circuit testing of minimum 40 KA at CPRI/NABL, 3 mtr long and having copper bonding thickness will be minimum 250 microns and copper bonded terminal size 130x50x5 mm terminal to connect earthing strip with 14 mm holes for nut bolts, buried directly and vertically in ground with top edge at 30 cm below ground level after making bore hole of 100 mm dia and 3.5 mtr deep using suitable mechanical drilling machine (for drilling near the specified bldg) connected with galvanized steel earthing lead of 32x6 mm strip with minimum two Nos of GI nut bolts and connected to test point from earthing pit. Area between pipe and copper rod filled with Dry type chemical powder.The electrode pipes should be filled with 2x 25 kg bags of carbide based BFC earthing compound of product code BFC25SILVR. The resistance of the compound should be less than 0.1 Oms . The compound should be highly conductive, hygroscopic, non magnetic, non corrosive in nature and have best moisture retaining qualities with ph value between 7-9. Connected to the earthing test point, Special high grade polymer compound Round earth pit with pit cover, including necessary returning filling & removal of extra soil , to achieved earth resistance value less than 1 Oms including testing complete all as specified Make U-Protect or equivalent NOTE: IF the desired result not obtained after testing the contractor should do re-eathing without any extra cost.
Om Construction
PAMS ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .