| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹39.0 L+₹43,337 (1.12%)Rejected-Finance VIVEKANANDA PALLY NEAR MARUTI TEA FACTORY P O BAGDGORA DIST DARJEELING | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹39.5 L+₹97,438 (2.53%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹39.5 L+₹98,128 (2.55%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹39.7 L+₹1.1 L (2.88%)Rejected-Finance 16 APC SARANI WARD NO 30 DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 WB | SILIGURI | DARJEELING | WEST BENGAL | 734004 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
20 Jul 2024, 6:00 pmClosed
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
REPAIR AND MAINT TO ISOLATION TRANSFORMERS, VOLTAGE STABILIZERS, OH LINES, PAINTING OF STEEL POLES, EXTERNAL ELECTRIFICATION, LT NETWORK INCLUDING REPAIR/ REPLACEMENT OF LT/UG CABLE, LT PANEL SWITCH GEAR AND ALLIED WORK AT 46 WEU, 273 SU AND 20 WING
2024_MES_662765_1
8580/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF Bagdogra
As per NIT
10 documents required · 10 mandatory
₹500
GE AF Bagdogra
₹72,000
Yes
24 Sept 2024
29 Jun 2024
22 Jul 2024
29 Jun 2024
20 Jul 2024
13 Jul 2024
Amount
M&L for online dehydration, filtration and cleaning of transformer oil, isolation transformer/ Servo voltage stabilizer etc at different locations by suitable dehydration plant testing of oil sample before and after dehydration for each transformer/equipment and results of transformer insulation oil minimum upto 11 KV with 2.5mm gap, recorded jointly by contractor and Engineer-in-Charge complete including all necessary tools, plants, transportation etc all as specified and directed by Engineer-in-Charge. Note:- (i) Oil for topping up/fresh fill shall be measured and paid separately under relevant item. (ii) Certificate for oil testing result before and after filtration shall be submitted to Engr-in-Charge.
M&L for topping up oil level with and including new insulating oil confirming to IS-335 including all necessary tools, plants, transportation etc complete all as specified and directed. Note:- (i) Certificate from manufacturer for oil testing result shall be submitted to Engr-in-Charge immediately after topping up.
M&L for preparation of surface for steel pole painting of any size by scrapping damaged paint and painting with two coats of silver aluminium paint and writing pole No with black paint on yellow circuit the bottom of pole to be painted with yellow and black paint as per the existing complete all as specified and directed.
All as per item No 3.00 above, but 2 pole structure complete with all structural steel.
All as per item No 3.00 here-in-before, but 4 pole structure complete with all structural steel.
M&L for restringing of ACSR conductor and removing unwanted sagging including trimming of tree branches 1.5 mtr clearance form OH conductor. One span between two poles is considered as one job complete all as specified and directed.
M&L for preparation of surface for Isolation transformer/ Servo Stabilizers of any type or capacity, painting by scrapping damaged paint and painting with two coats of suitable paint as per existing one and writing MES/MS No. with white paint on black circuit complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling isolation transformer/ Servo voltage stabilizer for repairs of any make of single phase upto capacity of 5 KVA, including transportation to workshop by removing coils, laminations, tank cleaning, reassembling of core and winding, with old serviceable parts and rewinded coils and other new parts in replacement of damaged parts, including brazing, soldering sleeveing and insulating etc as required and oven drying of core assembly complete all as specified and directed. Note:- 1 Replacement of unserviceable nuts/ bolts/ washer to be done within the quoted rate. 2 Other spares as required shall be measured and paid separately under relevant items.
All as per item No. 8.00 above, but three phase 5 to 20 KVA.
All as per item No. 8.00 here-in-before, but three phase 25 to 75 KVA.
All as per item No. 8.00 here-in-before, but three phase 100 to 200 KVA.
All as per item No. 8.00 here-in-before, but three phase but above 200KVA to 630 KVA.
Supply only in repair, under voltage, over voltage and surge protection display (display only) kit at out put section complete suitable for isolation transformer/ Servo voltage stabilizer of any make and capacity upto 20 KVA complete all as specified and directed. Make: Siemens/ L&T or other equivalent & approved make.
All as per item No.13.00 above, but capacity above from 20 KVA and upto 200 KVA.
Dismantling only in repair of under voltage, over voltage and surge protection kit complete of VCT D2 din rail mounting variant with digital display, auto/manual reset (timing and monitoring relay) complete protection kit suitable for isolation transformer/ Servo voltage stabilizer of any make and upto 20 KVA capacity complete all as specified and directed.
All as per item No 15.00 above, but from 25KVA to 50 KVA.
All as per item No 15.00 here-in-before, but from above 50KVA to 75 KVA.
All as per item No 15.00 here-in-before, but from 100KVA / 125 KVA.
All as per item No 15.00 here-in-before, but from 200KVA / 315 KVA.
All as per item No 15.00 here-in-before, but 315KVA / 630 KVA.
Dismantling and fixing after minor repairing and maintenance of Servo control board and performing suitable repairing and servicing at site, testing the same after required servicing complete for single phase Servo Stabilizers complete all as specified and directed.
All as per item No. 21.00 above, but for three phase servo stabilizers.
Supply only in repair, servo control card suitable for servo voltage stabilizer of any make and single phase complete all as specified and directed.
All as per Item No. 23.00 above, but for three phase.
Supply only in repair, servo motor starting torque of 3Kg/cm complete with necessary fixing arrangements complete all as specified and directed. Make - L&T/Siemens/HPL
All as per Item No. 25.00 above, but for 10 Kg/cm.
All as per Item No. 25.00 here-in-before, but for 20 Kg/cm.
Supply only in repair, limit switch suitable for isolation transformer/ Servo voltage stabilizer of any make and capacity complete all as specified and directed.
Supply only in repair, carbon brush suitable for servo voltage stabilizer of any make and capacity complete all as specified and directed.
Supply only in repair, manual change over switch, single phase MCB change over type suitable for servo stabilizer and isolation transformer upto 10 KVA capacity complete all as specified and directed. Make: Indo Asian /Siemens/L&T/Havells.
All as item No 30.00 above, but auto change over. Make: Indo Asian /Siemens/L&T/Havells.
Supply only in repair, manual change over switch, three phase MCB change over type suitable for servo stabilizer and isolation transformer of upto 10 KVA to 50 KVA capacity complete all as specified and directed. Make: Indo Asian /Siemens/L&T/Havells.
All as item No 32.00 above, but from 75 KVA to 100 KVA capacity.
All as item No 32.00 here-in-before, but from 125 KVA to 200 KVA capacity.
All as item No 32.00 here-in-before, but from 315KVA to 630 KVA capacity.
Supply only of isolation transformer over load control card with out cut off relay suitable for any three phase isolation transformer complete all as specified and directed.
Supply only in repair, DT Switch suitable for isolation transformer of any make and capacity as per site requirement complete all as specified and directed.
Supply only in repair, DT Switch suitable for servo voltage stabilizer of any make and capacity as per site requirement complete all as specified and directed.
Supply only in repair, new copper coil of short circuit/ over heated winding isolation transformer and servo voltage stabilizer of any make and upto 10 KVA capacity with matching gauge and turns of super enamelled copper winding wire complete with leathered paper, glass sleeves, varnishing, baking etc complete all as specified and directed.
All as per item No. 40.00 above, but capacity above 10 KVA and upto 630 KVA.
Supply only in repair, digital type voltmeter, 0-500 Volt, complete with necessary fixing complete all as specified and directed. Make: L&T /HPL/Siemens/Legrand.
Supply only in repair, ammeter 0-250 Amps, digital type, with CT operated complete with necessary fixing complete all as specified and directed. Make: L&T/HPL /Siemens/Legrand.
S&F in repair, 4 pole power contactors 32 Amp, conforms to IS/IEC 60947-4-1 and IEC 69947-4-1 complete all as specified and directed. Make: L&T, Model : MCX-03, Cat No. CS97011 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 44.00 above, but 4 pole power contactors 40 Amps. Make: L&T, Model : MCX-04, Cat No. CS97012 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 44.00 here-in-before, but 4 pole power contactors 80 Amps. Make: L&T, Model : MCX-13, Cat No. CS97015 or equivalent in C&S/ Havells/Siemens as approved.
S&F in repair, 4 pole power contactor, 160 Amp, conforms to IS/IEC 60947-4-1 and IEC 69947-4-1, with Aux contact 2 NO + 2 NC in existing panel complete all as specified and directed. Make: L&T, Model : MCX-32, Cat No. CS97020 or equivalent in C&S/ Havells/ Siemens as approved.
All as per item No. 47.00 above, but 4 pole power contactors 360 Amps. Make: L&T, Model : MCX-42, Cat No. CS97024 or equivalent in C&S/ Havells/Siemens as approved.
S&F in repair, front mounting add-on Aux Contact Block, 2 NO + 2NC for 4 pole power contactors MNX or MCX type of capacity 16 to 130 Amps, conforms to IS/IEC 60947-4-1 and IEC 69947-4-1 complete all as specified and directed. Make: L&T, Cat No. CS94114 or equivalent in C&S/ Havells/Siemens as approved.
S&F in repair, disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green 'two-in-series' assembly for tension with tension clamps for conductors complete all as specified and directed.
S&F in repair, shackle type, porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 75mm height, 90mm dia complete all as specified and directed.
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for taking out pipe line etc for repairs/ laying cables etc and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removal of excavated material [soil] to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for clean dry sand in trenches/ducts for cushioning to cable complete all as specified and directed. Note: Punned thickness shall be measured.
Supply and laying bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and directed.
Supply, laying, testing & commissioning in trenches after removing old cable and fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 120 Sqmm, 3.5 Core with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc complete all as specified and directed. Make: KEI/MESCAB/Havells/Gloster/ Polycab as of approved make.
All as per ser item No. 58.00 above, but 95 Sqmm, 3.5 Core.
All as per ser item No. 58.00 here-in-before, but 70 Sqmm, 3.5 Core.
All as per ser item No. 58.00 here-in-before, but 50 Sqmm, 3.5 Core.
All as per ser item No. 58.00 here-in-before, but 35 Sqmm, 3.5 Core.
All as per ser item No. 58.00 here-in-before, but 25 Sqmm, 3.5 Core.
All as per ser item No. 58.00 here-in-before, but 16 Sqmm, 4 Core
All as per ser item No. 58.00 here-in-before, but 10 Sqmm, 2 Core.
Supply and laying in repair, Tubes, 'light grade', galvanised iron, 50 mm bore laid in trenches for cable protection at road crossing etc including necessary making good or fixing on wall/ poles of any type, secured with clamps and required boring under road or hard surfaces complete with all fittings laid in trenches complete all as specified and directed.
Supply and laying in repair, Tubes, 'light grade', galvanised iron, 80 mm bore laid in trenches for cable protection at road crossing etc including necessary making good or fixing on wall/ poles of any type, secured with clamps and required boring under road or hard surfaces complete with all fittings laid in trenches complete all as specified and directed.
S&F in repair, PVC weather proof, hinged door, junction box with, 240V, Neutral link, three phase connector, with IP 66/67 protection suitable for outdoor installation on pole/wall surface and including with1 No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unserviceable junction box complete all as specified and directed. Make: Sintex Cat Part No. GSMB 2520, Hensel Cat Part No KF 2500H or equivalent of ISI Mark as approved.
M&L for preparation of surface for LT pole painting by scrapping damaged paint and painting with two coats of silver aluminium paint and writing pole No with black paint on yellow circuit each of 15 cm complete all as specified and directed.
M&L for cable jointing kit for LT straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm complete all as specified and directed.
All as per item No. 70.00 above, but for 3.5/ 4 core XLPE armoured aluminium conductor cable of size 25 to 50 sqmm.
All as per item No. 70.00 here-in-before, but for 4 core XLPE armoured aluminium conductor cable of size 10 to 16 sqmm.
M&L in repair, LT Panel outer door shall be made out of 3.15 mm thick CRCA Sheet factory fabricated lockable/ openable by keys or nuts locking system as per existing one. The degree of protection of outer door shall be IP-54 and painting the complete panel from out side as per the existing colour complete all as specified and as directed. Note: Measurement of door shall be taken before ordering to the supplier/ manufacturer and duly approved by Engr-in-Charge.
S&F in repair, digital type voltmeter 0-500 volt, three phase class 1.0 panel mounted 96 x 96 sqmm, flush mounted case complete with necessary fixing complete all as specified and directed. Make: HPL/Legrand/L&T/Schinder.
S&F in repair, ammeter 0-250 amps, digital type, three phase class 1.0 panel mounted 96 x 96 sqmm, flush mounted case with suitable size of CT complete with necessary fixing complete all as specified and directed. Make: HPL/Legrand/L&T/Schinder.
S&F in repair, LED indicator (colour red/ yellow/ blue/ white/ green) complete all as specified and directed.
S&F in existing panel for replacement of 4 pole on load changeover switch (I-O-II), for open execution of capacity 125 amps, complete with necessary fixing complete all as specified and directed. Make: Havells/Siemens/L&T/Indo Asian.
S&F in existing panel for replacement of 4 pole on load changeover switch (I-O-II), for open execution of capacity 200 amps, complete with necessary fixing complete all as specified and directed. Make: Havells/Siemens/L&T/Indo Asian.
M&L for taking out old unserviceable MCCB TPN/FP from existing feeder pillar/ LT panel board and supply and fixing MCCB TPN/FP 63 amps capacity, rup capacity 16 KA, 415 Volts, 50 Hz including necessary modification in panel board for incoming and outgoing cable connection with replacement of brunt lugs of suitable size for aluminium conductor cable, nuts bolts etc as per site requirement and as directed. Make: Havells/Siemens/L&T/Indo Asian.
All as per item No 79.00 above, but 100 amps capacity, 16 KA complete.
All as per item No 79.00 here-in-before, but 125 amps capacity,16 KA complete.
All as per item No 79.00 here-in-before, but 160 amps capacity, 36 KA complete.
All as per item No 79.00 here-in-before, but 200 amps capacity, 36 KA complete.
All as per item No 79.00 here-in-before, but 250 amps capacity, 36 KA complete.
All as per item No 79.00 here-in-before, but from 350 amps to 400 amps capacity, 36 KA complete.
M&L for pole earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the galvanised iron strip 25×4mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part-I 2009 and connection to earth test point all as specified and directed incl testing on completion”.
All as per item No. 86.00 above, but using 32 x 6 mm thick GI strip.
S&F in repair, galvanized iron strip of size 25 x 4 mm as earth continuity conductor buried in ground or fixed to wall/ floor/ ground provided with porcelain insulators space not less than 0.5 mtrs complete all as specified and directed.
All as item No 88.00 above, but galvanized iron strip of size 32 mm x 6 mm.
Taking out old unserviceable PCC pole 9 mtr long and supply and erection of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle complete all as specified and directed.
Demolition of PCC of any description above/below ground level exc. 15cm complete all as specified and directed.
M&L for plain cement concrete, (1:4:8), type D-2 (using 40mm graded stone aggregates) below GL as in foundation of pole etc complete all as specified and directed.
M&L for plain cement concrete, (1:3:6), type C1 (using 20mm stone aggregate) for coping for pole and stay in repairs complete all as specified and directed.
M&L for plain cement concrete, (1:3:6), type C2 (using 40mm stone aggregate) below GL as in foundation for stay assembly complete all as specified and directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
M/s Prakash Traders
UNISON CONSTRUCTION
RAMKRISHNA NARAYAN ROY & CO
SUNIL DAS AND CO
HALDER ENTERPRISERS
M/S MANAS MITRA
M/S P K ROY AND CO
M/s Chakraborty Enterprise
SHRI P P SHARMA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .